PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Automation, Laboratory”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

[The computer in a public health laboratory].

Author proposes discussing problems of computer's application into a laboratory of public health based on a long trial-run during which automation has been applied in every laboratory's field. There are also discussed milieu's and people's reactions.

Computers↗

The IPCS Collaborative Study on Neurobehavioral Screening Methods: III. Results of proficiency studies. Steering Group.

The goal of the IPCS Collaborative Study on Neurobehavioral Screening Methods was to determine the intra- and inter-laboratory reliability of a functional observational battery (FOB) and an automated assessment of motor activity in eight laboratories world-wide. The first phase of the Collaborative Study involved training the participants: evidence of training was then evaluated using positive-control compounds. The positive-control studies required the laboratories to identify, using the FOB, specific neurotoxic syndromes produced by acute exposure to p,p'-DDT, parathion, and by short-term repeated dosing with acrylamide. For the sake of expediency, only one dose of each chemical was used instead of collecting dose-response data. Motor activity test chambers were not of uniform design. The laboratories were therefore required to demonstrate adequate sensitivity by the ability to detect statistically-significant activity increases and decreases produced by triadimefon and chlorpromazine, respectively, following acute administration of a range of doses. The resulting FOB and motor activity data showed variability in the magnitude of effects obtained: some of these differences were attributed to miscommunications, difficulties with the techniques or protocol, or the limitations of having only one dose. All laboratories, however, successfully met the criteria set forth by the Study Steering Committee.

Animals↗

The IPCS Collaborative Study on Neurobehavioral Screening Methods: IV. Control data. Steering Group.

The goal of the International Programme on Chemical Safety (IPCS) Collaborative Study on Neurobehavioral Screening Methods was to determine the intra- and inter-laboratory reliability of a functional observational battery (FOB) and an automated assessment of motor activity in eight laboratories worldwide. The control data were crucial to the outcome of the studies in terms of sensitivity and reliability of the test measures, which in turn impact on the between-laboratory comparisons of chemical effects. In addition, analyses of control data can aid in determining endpoints that may require modification to improve their sensitivity and reliability. The control data from the eight laboratories were examined in terms of the following parameters: 1) control variability within studies for each laboratory; 2) within-laboratory replicability of control values across studies; 3) within-laboratory stability of control values over the course of testing for a given study; and 4) between-laboratory comparisons of parameters (1), (2), and (3). The analyses indicated considerable differences across endpoints, wherein some measures showed high variability and little replicability, while others were extremely reproducible. Generally, there were similar ranges of variability and replicability of control data across laboratories, although in some cases one or two laboratories were markedly different from the others. The physiological (weight, body temperature) and neuromuscular (grip strength, landing foot splay) endpoints exhibited the least variability, whereas the subjective assessments of reactivity varied the most. These data indicate a reasonable degree of comparability in the data generated in the participating laboratories.

Animals↗

The IPCS Collaborative Study on Neurobehavioral Screening Methods: V. Results of chemical testing. Steering Group.

The IPCS Collaborative Study on Neurobehavioral Screening Methods was undertaken to determine the intra- and inter-laboratory reliability of a functional observational battery (FOB) and an automated assessment of motor activity in eight laboratories world-wide. Following the training phase and the conduct of proficiency studies in all laboratories, participants proceeded to test the effects of seven chemicals in both single dose and four-week repeated dosing scenarios. The chemicals studied were acrylamide, bisacrylamide, p,p'-DDT, lead acetate, parathion, toluene, and triethyl tin. Participants received coded samples from a common source. In order to judge the general utility of these procedures in a diversity of testing situations, laboratories conducted the studies under their standard conditions, using their choice of rat strain and test equipment. Chemical does and time of peak effect for acute testing were determined by each laboratory: these parameters were quite similar for some chemicals, but varied greatly for others. The results of the chemical tests indicated that while there was some variability in the data on specific endpoints, all laboratories detected and characterized the effects of all but one of the known neurotoxicants. The one exception (toluene) was probably due to other factors (e.g., dose level, route of administration) rather than lack of sensitivity of the test methods. This study provides extensive data regarding the use of neurobehavioral screening methods over a range of laboratory conditions as well as the reliability, sensitivity, and robustness of the tests to detect neurotoxic potential of chemicals.

Animals↗

The IPCS Collaborative Study on Neurobehavioral Screening Methods: VI. Agreement and reliability of the data.

The IPCS Collaborative Study on Neurobehavioral Screening Methods was undertaken to determine the intra- and inter-laboratory reliability of a functional observational battery (FOB) and an automated assessment of motor activity in eight laboratories world-wide. The effects of seven chemicals (acrylamide, bis-acrylamide, p,p'-DDT, lead acetate, parathion, toluene, and triethyl tin) were studied during two dosing regimens: single-dose and four-week repeated dosing. All participating laboratories generally could detect and characterize the effects of known neurotoxicants, even though there were some differences in outcome on specific endpoints. The results were further evaluated to assess the agreement across laboratories in the dose-response data at the expected times of maximal effect (time of peak effect for the single-dose studies, and during or at the end of dosing for repeated-exposure studies). Percent agreement was calculated as the percentage of laboratories agreeing on an outcome (whether it be a significant dose effect or not). As an alternative approach, slopes of the dose-response functions were calculated, and reliability of those slope estimates across laboratories and chemicals was determined. Reliability was defined as the degree of agreement across laboratories (intraclass correlation coefficient) of the dose-response slopes within and between chemicals. These reliability estimates were calculated for each domain and for each endpoint. Relative reliability of the endpoints was evaluated, and hypotheses concerning the influence of outlying data were tested. The data clearly showed that reliability was not influenced by the objectivity or subjectivity of the test measure. Thus these data provide additional information regarding the reliability and robustness of the tests across the participating laboratories.

Animals↗

Automated serum protein electrophoresis by Capillarys.

Capillary zone electrophoresis (CZE) of serum proteins is increasingly gaining impact in clinical laboratories. In this report, we evaluate automated capillary zone electrophoresis by Capillarys (Sebia, France). Within-run and between-run imprecision for the five electrophoretic fractions was <2% and <6%, respectively. Data obtained with Capillarys correlated with results obtained with agarose gel electrophoresis and Paragon CZE 2000 (Beckman Coulter, USA). Analysis of serum obtained from patients with inflammation, nephrotic syndrome, bisalbuminemia, and alpha1-antitrypsin deficiency revealed that Capillarys was able to detect these abnormalities. Two hundred thirty eight samples were analyzed by agarose gel electrophoresis, Capillarys, capillary electrophoresis using Paragon CZE 2000 system, and immunofixation. Sample selection was based on the presence of a disturbed morphology (e.g., spike) of the protein profile or hypogammaglobulinemia on agarose gel electrophoresis and/or Capillarys. Immunofixation revealed the presence of a monoclonal protein, oligoclonal bands, polyclonal pattern, and a normal profile in, respectively, 89, 66, 19, and 64 samples. With Capillarys, Paragon, and agarose gel electrophoresis, a spike and/or disturbed morphology of the profile was found in 222, 182, and 180 samples, respectively. In these samples, immunofixation was negative in 73 (33%), 46 (25%), and 39 (22%) samples, respectively. These data indicate that Capillarys has a lower specificity than agarose gel electrophoresis and Paragon 2000. Of the 89 samples with a monoclonal protein, Capillarys, Paragon, and agarose gel electrophoresis failed to detect, respectively, three, three, and one monoclonal protein(s). Interferences by radio-opaque agents, complement degradation products, fibrinogen, and triglycerides are described. In conclusion, automated capillary zone electrophoresis with Capillarys provides for reproducible, rapid, and reliable serum electrophoresis.

Adult↗

Stability of common analytes in urine refrigerated for 24 h before automated analysis by test strips.

BACKGROUND: Central outpatient laboratories might find processing large numbers of urinary samples that arrive in the late afternoon inconvenient and refrigerate them overnight before testing. Furthermore, in certain settings clinics might have difficulty assuring that the urine arrives at the laboratory during the same day as the collection. Because the stability of urine samples for delayed automated dipstick analysis (Supertron) is unknown, after defining precision, we retested urines refrigerated for 24 h to determine stability. METHODS: Urinalysis was done twice on the same day and repeated after the sample was refrigerated for 24 h. Combur-10S (Roche Diagnostics) dipsticks were read automatically by a Supertron analyzer. Repeat tests on the same day were compared with tests after storage. RESULTS: Leukocyte esterase had high precision, but after storage approximately 25% of the positive samples were less reactive (P: <0.005). Precision of hemoglobin retests was also high but declined significantly after storage for 24 h. Urine protein values increased after storage. The precision and stability were excellent for nitrites, glucose, and ketones. CONCLUSIONS: The stability of the automated dipstick urinalysis varies with the substance tested. After refrigeration for 24 h, there is a risk of false-positive results for protein, false-negative results for leukocytes and erythrocytes, and little effect on glucose, nitrite, and ketone values.

Autoanalysis↗

Restructuring of international council for standardization in haematology (ICSH) in Asia.

Standardization and harmonization in Laboratory testing are a key issue in the midst of globalization era, because most of laboratory testing has been currently achieved with various kinds of automated systems. In the developed countries, automated systems with highly-regulated principles are commonly used in the routine laboratory. However, there are so many undeveloped and developing countries in Asia that diversity of testing levels can be observed in the area. Some laboratories use glass chamber method for blood cell counting, while other laboratory use semi-automated or fully automated analyzers for complete blood count. International standardization on Hematology is focused on the developed system but not for the developing system. Established standardized documents therefore whould not be unsuitable for Asian societies. In the context, International Council for Standardization in Hematology (ICSH) changed its rules to adjust our Asian Societies and ICSH started to restructure the body. International ICSH society is divided into 5 region sub-groups. Asian area is able to possess one new sub-society, ICSH-Asia. Its reconstruction work has been just started with Asain colleagues, and we are now extending the new societies to discuss Asian problems on the quality of hematology testing.

Asia↗

Automated carboxy-terminal sequence analysis of peptides and proteins using diphenyl phosphoroisothiocyanatidate.

Proteins and peptides can be sequenced from the carboxy-terminus with isothiocyanate reagents to produce amino acid thiohydantoin derivatives. Previous studies in our laboratory have focused on the automation of the thiocyanate chemistry using acetic anhydride and trimethylsilylisothiocyanate (TMS-ITC) to derivatize the C-terminal amino acid to a thiohydantoin and sodium trimethylsilanolate for specific hydrolysis of the derivatized C-terminal amino acid (Bailey, J.M., Shenoy, N.R., Ronk, M., & Shively, J.E., 1992, Protein Sci. 1, 68-80). A major limitation of this approach was the need to activate the C-terminus with acetic anhydride. We now describe the use of a new reagent, diphenyl phosphoroisothiocyanatidate (DPP-ITC) and pyridine, which combines the activation and derivatization steps to produce peptidylthiohydantoins. Previous work by Kenner et al. (Kenner, G.W., Khorana, H.G., & Stedman, R.J., 1953, Chem. Soc. J., 673-678) with this reagent demonstrated slow kinetics. Several days were required for complete reaction. We show here that the inclusion of pyridine was found to promote the formation of C-terminal thiohydantoins by DPP-ITC resulting in complete conversion of the C-terminal amino acid to a thiohydantoin in less than 1 h. Reagents such as imidazole, triazine, and tetrazole were also found to promote the reaction with DPP-ITC as effectively as pyridine. General base catalysts, such as triethylamine, do not promote the reaction, but are required to convert the C-terminal carboxylic acid to a salt prior to the reaction with DPP-ITC and pyridine. By introducing the DPP-ITC reagent and pyridine in separate steps in an automated sequencer, we observed improved sequencing yields for amino acids normally found difficult to derivatize with acetic anhydride/TMS-ITC. This was particularly true for aspartic acid, which now can be sequenced in yields comparable to most of the other amino acids. Automated programs are described for the C-terminal sequencing of peptides covalently attached to carboxylic acid-modified polyethylene and proteins (200 pmol to 5 nmol) noncovalently applied to Zitex (porous Teflon). The generality of our automated C-terminal sequencing methodology was examined by sequencing model peptides containing all 20 of the common amino acids. All of the amino acids tested were found to sequence in good yield except for proline, which was found not to be capable of derivatization. In spite of this limitation, the methodology should be a valuable tool for the C-terminal sequence analysis of peptides and proteins.(ABSTRACT TRUNCATED AT 400 WORDS)

Amino Acid Sequence↗

Determination of low molecular weight heparin in clinical laboratory.

The applicability was investigated of automated spectrophotometric heparin assays and three clotting assays for determination of two low molecular weight (LMW) heparin fractions: Org 10172 and DxN10 and two infractionated commercially available heparins. The relative activity of the two commercially available heparins was similar in the anti-Xa assay, in the anti-IIa assay and in 3 clotting assays. The LMW heparins showed markedly different relative activity in all 5 assays. The activities of those heparin preparations relative to the standard heparin were compared in the 5 assays, but standardization against a standard heparin preparation appeared impossible. Methods of heparin determination can be used to monitor treatment with a heparin preparation only if the same preparation is used as a reference substance.

Chondroitin Sulfates↗

Capillary electrophoresis as a clinical tool.

Clinical laboratories must produce accurate results for patients with a minimum turn-around time. Automated commercial capillary electrophoresis instrumentation has been available to the clinical laboratory for the past five years. Our laboratory has utilised capillary electrophoresis (CE) to automate serum protein electrophoresis. We have used the technique of CE to produce clinical results for nearly two years. CE methods are also available for the quantitation of haemoglobin variants, by both isoelectric focusing and free solution techniques. Micellar electrokinetic separations by CE have been developed for some specialised drug assays and for B-group vitamin analysis, while gel-filled capillaries have the capability to separate DNA fragments, such as PCR products. Isoenzyme analysis has shown possibilities by CE, but quantitative results are needed to be clinically useful. Analysis of amino acids for newborn screening programs and as an arterial clotting indicator are being developed. The next five years should see a proliferation of clinical laboratory methods using automated CE.

Blood Protein Electrophoresis↗

ACAPELLA-1K, a capillary-based submicroliter automated fluid handling system for genome analysis.

The Genomation Laboratory in the Electrical Engineering Department at the University of Washington has been developing an automated, high-throughput, submicroliter-scale fluid-handling system for use in molecular biology, especially as part of the Human Genome Project and other high-throughput DNA sequencing endeavors. Small glass capillaries enable the preparation, handling, and monitoring of 1-microliter reaction volumes. The Genomation Laboratory, with corporate partners Orca Photonic Systems, Inc. and Engineering Arts, has developed modules for aspiration, dispensing, mixing, transport, and rapid thermal processing of biological samples contained in glass capillaries. The ACAPELLA-1K is the first integration of these modules, designed to process 1000 samples in an eight-hour day. It has served as a test bed for the technologies as well as for performing biological experiments in conjunction with the University of Washington Genome Center. This system and related results are presented in this paper. A video of the system in operation is provided at. The Genomation Laboratory is presently developing the next-stage ACAPELLA-5K system based on the results of the ACAPELLA-1K system.

Automation↗

An automated method for studying drug effects on problem solving by small laboratory animals.

The design and construction details of a method for studying problem solving by small animals is described. The form of motivation is escape from water in a T-shaped apparatus, thus eliminating possible confounding effects involved when food or water intake is restricted below normal. The arm of the T in which escape is possible is alternated from trial to trial. Two levels of problem solving are evaluated: an animal can minimize escape time during a series of trials by alternating its responses, i.e., 100% reinforcement; alternatively, it may choose the same alley on each trial, which results in only 50% reinforcement. The time to make the decision and the total time are automatically recorded. We have demonstrated the sensitivity of the method to hypofunctioning of the cholinergic neurotransmitter system, an analogy to behavioral changes accompanying progressive degenerative dementia. Two effects of the hypocholinergic state were especially notable: animals in this state have significantly greater difficulty in shifting from the "primitive" position habit to the more complex alternation solution, and preliminary experiments suggest that certain pharmacological treatments may be effective in overcoming this deficiency.

Animals↗

Inappropriate platelet transfusion in a patient with ethylenediamine tetra- acetic acid (EDTA)--induced pseudothrombocytopenia.

Automated platelet counts in the laboratory may be fictitiously low at times and require manual confirmation. Ethylenediaminetetra-acetic acid (EDTA) in few patients and healthy individuals can induce platelet aggregation, giving rise to a spuriously low automated platelet count. This phenomenon which occurs due to the presence of IgG antibodies, if unrecognized, can result in incorrect diagnosis and consequent inappropriate treatment. We present a patient who received inappropriate platelet transfusion as a result of EDTA induced spurious thrombocytopenia.

Adult↗