PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ELECTROENCEPHALOGRAPHY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Full-band EEG (FbEEG): an emerging standard in electroencephalography.

While enormous resources have been recently invested into the development of a variety of neuroimaging techniques, the bandwidth of the clinical EEG, originally set by trivial technical limitations, has remained practically unaltered for over 50 years. An increasing amount of evidence shows that salient EEG signals are observed beyond the bandwidth of the routine clinical EEG, which is typically around 0.5-50 Hz. Physiological and pathological EEG activity ranges at least from 0.01 Hz to several hundred Hz, as demonstrated in recordings of spontaneous activity in the immature human brain, as well as during epileptic seizures, or various kinds of cognitive tasks and states in the adult brain. In the present paper, we will review several arguments leading to the conclusion that elimination of the lower (infraslow) or higher (ultrafast) bands of the EEG frequency spectrum in routine EEG leads to situations where salient and physiologically meaningful features of brain activity are ignored. Recording the full, physiologically relevant range of frequencies is readily attained with commercially available direct-current (DC) coupled amplifiers, which have a wide dynamic range and a high sampling rate. Such amplifiers, combined with appropriate DC-stable electrode-skin interface, provide a genuine full-band EEG (FbEEG). FbEEG is mandatory for a faithful, non-distorted and non-attenuated recording, and it does not have trade-offs that would favor any frequency band at the expense of another. With the currently available electrode, amplifier and data acquisition technology, FbEEG is likely to become the standard approach for a wide range of applications in both basic science and in the clinic.

Brain↗

Simultaneous multilobar electrocorticography (mEcoG) and scalp electroencephalography (scalp EEG) during intracranial vascular surgery: a new approach in neuromonitoring.

OBJECTIVE: Intraoperative neuromonitoring for intracranial vascular surgery is primarily aimed at detecting early ischemic changes to prevent subsequent infarction. Despite various neurophysiological approaches detection of early and focal ischemic changes remains difficult. This study explores the feasibility and sensitivity of intraoperative monitoring using surface EEG (scalp EEG) and multilobar Electrocorticography (mEcoG) recording during intracranial vascular procedures. METHODS: About 21 recordings were acquired in 20 patients undergoing craniotomies for intracranial aneurysms (17), superficial temporal-middle cerebral artery bypass (twice in the same patient) and arteriovenous malformation (2). The recording of scalp EEG (needle electrodes) and EcoG was performed (cupules electrodes) during all of the surgery. Signal was visually analyzed online and using spectral analysis software offline. RESULTS: Good recordings were obtained in all cases, without adding any procedural morbidity. The most common abnormalities on mEcoG were high frequency waves (23-37 Hz; HF-beta3), which appeared just after vascular occlusion and were occasionally followed by slow waves or burst suppression pattern. This focal pattern was seen in a majority of cases (20/21) on the mEcoG, but only in 4 out of 21 cases on the EEG. CONCLUSIONS: Multi-lobe (mEcoG) recording is feasible during craniotomies and detects earlier and more EEG pattern variation than surface EEG monitoring during intracranial vascular manipulations. The authors discuss the high sensitivity of this technique to ischemic changes. SIGNIFICANCE: By detecting earlier and more focal changes than scalp EEG, mEcoG may favor during surgery an increase in interactive strategies and reduction of deleterious event.

Adult↗

Prevention of ischemic neurologic injury with intraoperative monitoring of selected cardiovascular and cerebrovascular procedures: roles of electroencephalography, somatosensory evoked potentials, transcranial Doppler, and near-infrared spectroscopy.

All neuromonitoring techniques, although imperfect, provide useful information for monitoring cardiothoracic and carotid vascular operations. They may be viewed as providing complementary information, which may help surgical technique and, as a result, possibly improve clinical outcomes. As of this writing, the efficacy of TCD and NIRS monitoring during cardiothoracic and vascular surgery cannot be considered established. Well designed, prospective, adequately powered, double-blind, and randomized outcome studies are needed to determine the optimal neurologic monitoring modality (or modalities), in specific surgical settings.

Brain↗

Electroencephalography (EEG) and somatosensory evoked potentials (SEP) to prevent cerebral ischaemia in the operating room.

We review the principal aspects of EEG and SEP to detect and prevent cerebral ischaemia in the operating room during interventions at risk. EEG and SEP are variables that indirectly reflect cerebral blood flow (CBF) provided that anaesthetic regimen, body temperature, and arterial blood pressure of the patient are stable. When CBF decreases and reaches the functional threshold, slowing and/or attenuation of EEG occurs while the amplitude and the latency of cortical SEP are, respectively decreased and lengthened. Based on these changes, numerous criteria corresponding to critical thresholds have been defined. A decrease in EEG amplitude greater than 30% or EEG changes lasting more than 30 s have been considered as significant by clinicians. The main criteria resulting from computerized EEG analysis were a reduction in total power and/or in spectral edge frequency. Regarding SEP, a more than 50% decrease in N20 amplitude and/or a more than 1 ms increase in central conduction time were the most frequently used criteria. According to the bulk of literature, it may be concluded that processed EEG analysis is more sensitive than visual EEG analysis to detect cerebral ischaemia, and that SEP are not less sensitive than conventional EEG. Moreover, literature shows that SEP are as specific as computerized EEG analysis to disclose ischaemia during carotid endarterectomy.

Brain Ischemia↗

Electroencephalography effects to semantic and non-semantic mismatch in properties of visually presented single-characters: the N2b and the N400.

Event-related potential (ERP) correlates of semantic and non-semantic mismatch in the 200-400ms time interval were dissociated. Twelve subjects observed pairs of single letters and digits presented serially, and decided whether the colour (blue or red) or the category membership (letter or number) of the second item in a pair matched the first one. In both tasks mismatch elicited central N2b components (220ms peak latency in the colour matching task, and 280ms peak latency in the category matching task). Furthermore, in the category matching task a centro-parietal negativity (N400) emerged. The topography of the N2b effect was clearly distinct from that of the N400 effect. Analysis of event-related spectral perturbations confirmed that N400 time-range effects were specific to category matching. We conclude that while the N400 effect is a specific marker of semantic mismatch, the N2b effect is a general correlate of detecting mismatch between the representations of task-relevant features.

Adolescent↗

Speech comprehension assessed by electroencephalography: a new method using m-sequence modulation.

Electroencephalograms (EEGs) were recorded from eight Japanese speakers while they listened to Japanese and Spanish sentences (approximately 51s each). The sentences were modulated in amplitude by a binary m-sequence and played forward or backward. A circular cross-correlation function was computed between the EEG signals and the m-sequence and averaged across subjects. Independent component analysis of the averaged function revealed a component source response which was obtained only for the comprehensible Japanese and not for the incomprehensible sentences. The present study has thus shown that a 1-min long EEG signal is sufficient for the assessment of speech comprehension.

Acoustic Stimulation↗

Electroencephalography-correlated functional MR imaging studies of epileptic activity.

EEG-fMRI is capable of providing novel localizing information in a substantial proportion of patients with frequent epileptiform discharges, even at 1.5T, suggesting a potential clinical role. Increasing availability of equipment capable of providing good-quality intra-MR imaging EEG with relative ease should ensure a more widespread application of the technique in neurology and neuroscience. Early findings in epilepsy have raised a number of interesting issues related to the localization of the activations and the time course of the event-related response that require further investigation. These investigations will benefit from substantial increases in sensitivity resulting from recent and forthcoming technical developments. Validation of the findings will require comparison with invasive and postsurgical findings and further correlations with other measures of brain activity,which should also lead to an improved understanding of the underlying phenomena. To facilitate comparison of findings, improved reporting standards are needed-namely, illustration of activation maps using the glass-brain-more consistent threshold selection,and the listing of all activation clusters, including their volumes, maximum (or minimum) z scores, and peak signal change.

Brain↗

Magnetic resonance spectroscopy and electroencephalography in baclofen coma.

This report describes a 14-year-old female who presented with coma and seizures. Continuous electroencephalographic monitoring revealed suppression and semiperiodic sharp waves. Magnetic resonance spectroscopy performed 1 day after admission suggested a good outcome despite her clinical examination and electroencephalogram. She was subsequently found to have elevated serum baclofen levels after an intentional overdose. At the time of her discharge from the pediatric intensive care unit, she manifested no neurologic deficits, and on telephone follow-up 2 years after the ingestion the patient had no complaints of any cognitive problems or neurologic dysfunction.

Adolescent↗

An audit of electroencephalography requests: use and misuse.

OBJECTIVE: To investigate whether electroencephalogram (EEG) requests at St George's Hospital (SGH) are being made according to clinical guideline recommendations. METHODS: A retrospective audit at a regional neurology and neurosurgery referral centre, also serving a district population. All adult National Health Service patients undergoing standard EEG between 1st November 2003 and 31st January 2004, for whom the request originated within the hospital, were identified. Data was collected from each subject's case notes, request form and EEG report and compared to predetermined criteria. RESULTS: Fifty sets of notes from ninety patients meeting the inclusion criteria were available for review. Twenty-six percent of requests were considered 'inappropriate', with respect to clinical guidelines, of which 92% were for 'funny turns' where there appeared to be insufficient clinical evidence to justify the request. The EEG contributed to diagnosis or management in only 22% of cases, all of which had been appropriately requested. Neurologists/epileptologists appeared better than non-specialists in terms of appropriateness of referrals, though the numbers were too small to reach significance (p = 0.173, Fisher's exact). Forty-two percent of all patients, and less than 10% of outpatients, had their EEG within the guideline target wait of 4 weeks. CONCLUSIONS: Over a quarter of EEG referrals are not being made in accordance with guidelines, mainly because of the misconception that an EEG can confirm or exclude a diagnosis of epilepsy in patients with "funny turns". In addition, less than 10% of out patient requests are being met within 4 weeks. Strategies to maximise service utilisation are discussed.

Adult↗

Electroencephalography and subjective ratings of sleep deprivation.

BACKGROUND AND PURPOSE: Sleep-related vehicle accidents account for many injuries and fatalities each year on monotonous motorways and roads. To effectively prevent such incidents requires greater knowledge of the mechanisms and development of the effects of sleep deprivation. Ten volunteers participated in a laboratory study aimed to analyze the way changes in wakefulness were described in terms of EEG changes and subjective ratings. PATIENTS AND METHODS: For each subject, the study consisted of four testing sessions that varied in length on different days: one session each of 60, 90, and 120 min when sleep-deprived, and one session of 120 min when rested. Changes in wakefulness were analyzed using electroencephalographic recordings and ratings on two different scales, the Karolinska Sleepiness Scale (KSS) and the Category-Ratio Scale (CR-10). RESULTS: The results indicate quite conclusively that significant changes in the perception of sleepiness occur during the first 60-90 min of sedentary, monotonous work. Beyond this time period, subjective and physiological changes remained constant throughout the rest of the 120-min period. CONCLUSION: In general, the subjective rating scales highly and significantly correlated with theta activity in both tired and rested states and with alpha activity in the rested state. Similar results were seen using both subjective rating scales.

Adult↗

Prognostic value of electroencephalography in cardiac surgery.

One hundred seventeen patients undergoing cardiac operations over a two-year period were studied. Electroencephalograms were recorded preoperatively, in the recovery room (up to 12 hours following operation), 24 hours later, and further as required. Operative and anesthesia data were correlated with EEG findings. All patients had normal EEGs preoperatively. This unusual occurrence may largely reflect the absence of congenital heart disease and the small number of valvular lesions in our patients. Prognosis was not significantly influenced by age. Bypass time appeared directly related to outcome by group but not individually. Hypotension prior to pumping occurred most often and mean blood loss was greatest in the patients who had abnormal EEGs in the recovery room with progressively worsening patterns until death. In the recovery room many patients were awake, while others were either drowsy, lethargic, or asleep. Some were comatose. The level of consciousness was not as prognostic as was the EEG. The pattern of EEGs in the first few postoperative days is more important than any single record by itself. All those who showed progressive deterioration in the first two or three days died shortly thereafter.

Adolescent↗

Global, regional, and local measures of complexity of multichannel electroencephalography in acute, neuroleptic-naive, first-break schizophrenics.

BACKGROUND: Schizophrenic symptoms commonly are felt to indicate a loosened coordination, i.e. a decreased connectivity of brain processes. METHODS: To address this hypothesis directly, global and regional multichannel electroencephalographic (EEG) complexities (omega complexity and dimensional complexity) and single channel EEG dimensional complexities were calculated from 19-channel EEG data from 9 neuroleptic-naive, first-break, acute schizophrenics and 9 age- and sex-matched controls. Twenty artifact-free 2 second EEG epochs during resting with closed eyes were analyzed (2-30 Hz bandpass, average reference for global and regional complexities, local EEG gradient time series for single channels). RESULTS: Anterior regional Omega-Complexity was significantly increased in schizophrenics compared with controls (p < 0.001) and anterior regional Dimensional Complexity showed a trend for increase. Single channel Dimensional Complexity of local gradient waveshapes was prominently increased in the schizophrenics at the right precentral location (p = 0.003). CONCLUSIONS: The results indicate a loosened cooperativity or coordination (vice versa: an increased independence) of the active brain processes in the anterior brain regions of the schizophrenics.

Acute Disease↗

A quantified analysis of sleep electroencephalography in anorectic adolescents.

BACKGROUND: Previous studies on sleep characteristics in anorexia nervosa have led to controversial results. This may be due to either the heterogeneity of the samples studied or to an intrinsic inadequacy of the scoring criteria. To obtain a more detailed analysis we have investigated sleep characteristics in a group of adolescents affected by anorexia nervosa using spectral analysis techniques. METHODS: After a baseline night, the sleep-electroencephalograms of 10 adolescent anorectic girls (age +/- SD = 14 +/- 2 years) and 10 age-matched control subjects were recorded and processed by a fast Fourier transformation routine. RESULTS: Anorectics showed an increased number of awakenings and wakefulness after sleep onset and a reduction of sleep efficiency and slow-wave sleep. Spectral analysis results revealed a significant reduction in the power spectral values of slow-wave activity (SWA; 0.5-4.5 Hz) band in all NREM-REM cycles of sleep and in the undisturbed and stable stage 4. Moreover the anorectic group was characterized by a concentration of SWA in the first NREM-REM cycle with an abrupt decay in the second part of the night. A positive correlation (r2 = .58, p < .01) between body mass index and the amount of SWA was found. CONCLUSIONS: Sleep of anorectic patients seems to be characterized by a weakness of SWA producing mechanisms. The positive correlation between body mass index and the amount of SWA appears to be consistent with the neurobiological consequences of the malnutrition state.

Adolescent↗

Serotonin-dependent maintenance of spatial performance and electroencephalography activation after cholinergic blockade: effects of serotonergic receptor antagonists.

The interaction between acetylcholine (ACh) and serotonin (5-hydroxytryptamine, 5-HT) in the control of behavior such as spatial navigation has received considerable attention over the last years. Previous research indicates that while a selective reduction in cholinergic transmission often produces only mild impairments in spatial and other behavioral tests, additional serotonergic blockade results in the appearance of severe behavioral deficits. Consequently, it has been argued that 5-HT plays a role in the maintenance of behavioral capacities in the face of reduced cholinergic transmission. Here, we examined the effects of 5-HT depletion and receptor blockade, alone and in combination with cholinergic-muscarinic antagonism, on spatial navigation of rats in the Morris water maze. Further, electroencephalographic (EEG) recordings were taken to test the hypothesis that a loss of neocortical activation is related to the behavioral deficits apparent after cholinergic-serotonergic blockade. The muscarinic antagonist, scopolamine (1 mg/kg) produced a moderate impairment in navigational performance. The 5-HT depletor, p-chlorophenylalanine (PCPA; 500 mg kg(-1) day(-1)x2) did not impair performance when given alone but strongly potentiated the scopolamine-induced deficit and completely blocked the acquisition of an escape response in the water maze. This effect was mimicked by the non-selective serotonin(1-2) receptor antagonist, methiothepin (0.3 mg/kg), but not by the selective serotonin(1A) antagonist, WAY 100635 (0.1-0.5 mg/kg) or the serotonin(2) antagonist, ketanserin (2-4 mg/kg). None of the 5-HT antagonists impaired performance when given alone. Electrocorticographic recordings in rats treated with scopolamine and serotonergic receptor antagonists showed that during behavioral immobility, scopolamine (1 mg/kg) increased spectral power in all frequency bands between 0.5 and 20 Hz without significantly affecting cortical activity during movement. None of the 5-HT antagonists affected cortical activity when given alone. However, methiothepin, at the same dose that produced behavioral impairments, increased spectral power between 0.5 and 4 Hz and between 8 and 12 Hz during movement when co-administered with scopolamine. The results suggest that a concurrent blockade of multiple 5-HT receptors, but not selective blockade of serotonin(1A) or serotonin(2) receptors alone, mimics the ability of global 5-HT depletion to abolish behavioral capacities that are resistant to muscarinic receptor blockade. The behavioral deficits observed here are accompanied by a reduction in neocortical activation, suggesting that disturbances of processing in cortical networks can contribute to the behavioral disorganization apparent after cholinergic and serotonergic blockade. A focus on concurrent serotonergic-cholinergic deficits may provide a useful framework for the development of novel pharmacological treatments to counteract the behavioral disorganization and loss of EEG activation present in senile dementia and Alzheimer's disease.

Acetylcholine↗

Prognostic value of neonatal electroencephalography in premature newborns less than 33 weeks of gestational age.

In a prospective study of 417 premature neonates born before 33 weeks' gestational age, neonatal tracings were reviewed to evaluate the use of EEG in prognosis of neurological injuries. The population was divided into two groups: Group 1, infants who died before the age of 1, and Group 2, survivors in which two categories of motor development were considered. Category A, were abnormal, and Category B, were always normal. Positive rolandic sharp waves (PRSW), which reflect white matter injury, occurred equally in both groups, indicating a similar incidence of white matter damage in Groups 1 and 2. In Group 2, there was a significant correlation of PRSW with developmental motor sequelae (Category A). A frequency of PRSW above 2/min (suggesting more severe periventricular white matter injury) and seizures were significantly more prevalent in Group 1 than in Group 2 and in Category A of Group 2 than in Category B. Background abnormalities occurred equally in both subgroups of extremely premature infants (< or = 28 weeks' gestation) they were significantly more numerous in the subgroup of very premature infants (between 28 and 33 weeks' gestation) who died, than in the subgroup of very premature infants who survived. This study shows the potential utility of using neonatal EEG in association with transfontanellar ultrasonography in anticipating the neurological development of very (> 28 weeks' gestation) and extremely (< or = 28 weeks' gestation) premature newborns.

Asphyxia↗

Reproducibility and validity of electric source localisation with high-resolution electroencephalography.

The present study investigates the reproducibility and validity of the EEG source localisation of somatosensory evoked potentials (SEPs) using high-resolution EEG (61 scalp electrodes) and a source reconstruction on the basis of the individual brain morphology as obtained from magnetic resonance images (MRIs). The somatosensory evoked potentials (SEPs) to electrical stimulation of the right median nerve were repeatedly collected from the scalp of one healthy subject in 9 replications run on 9 different days. The source reconstruction for the 19 ms SEP component was performed by using a single moving dipole model as a source model. Two different head models were used: a spherical 3 shell model and a more realistically shaped 3 compartment model computed using the boundary element method (BEM). The source locations of the 19 ms SEP component were found to be highly reproducible using both head models: the mean standard deviation of the dipole locations was found to be 2.6 mm for the 3 shell model and 4 mm for the more realistically shaped head model. By projection into the individual MRI, the dipoles resulting from either head models were found to be located within the postcentral gyrus. The electric source locations were consistent with the maximum of the task-specific changes seen in a functional magnetic resonance imaging (fMRI) experiment when using the same somatosensory stimulation protocol.

Brain Mapping↗

The fundamental neural mechanisms of electroencephalography.

We are at an interesting time in the evolution of the EEG. Studies are opening the door to understanding the intrinsic neuronal properties and network operations responsible for the generation of EEG oscillations. I will review some of our knowledge regarding the physiology of the normal and abnormal EEG. Both epileptic and non-epileptic activity will be discussed. Less is known about the latter, because of difficulties in developing appropriate models. The major dichotomy for both types of EEG phenomenon will be focal and generalized (or widespread. Certain distinctive abnormal EEG patterns including burst suppression, periodic phenomena and intermittent rhythmic delta will also be addressed.

Animals↗