PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Ejection fraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Variability of left ventricular ejection fraction and volumes with quantitative gated SPECT: influence of algorithm, pixel size and reconstruction parameters in small and normal-sized hearts.

PURPOSE: Several software packages are commercially available for quantification of left ventricular ejection fraction (LVEF) and volumes from myocardial gated single-photon emission computed tomography (SPECT), all of which display a high reproducibility. However, their accuracy has been questioned in patients with a small heart. This study aimed to evaluate the performances of different software and the influence of modifications in acquisition or reconstruction parameters on LVEF and volume measurements, depending on the heart size. METHODS: In 31 patients referred for gated SPECT, 64(2) and 128(2) matrix acquisitions were consecutively obtained. After reconstruction by filtered back-projection (Butterworth, 0.4, 0.5 or 0.6 cycles/cm cut-off, order 6), LVEF and volumes were computed with different software [three versions of Quantitative Gated SPECT (QGS), the Emory Cardiac Toolbox (ECT) and the Stanford University (SU-Segami) Medical School algorithm] and processing workstations. Depending upon their end-systolic volume (ESV), patients were classified into two groups: group I (ESV>30 ml, n=14) and group II (ESV<30 ml, n=17). Agreement between the different software packages and the influence of matrix size and sharpness of the filter on LVEF and volumes were evaluated in both groups. RESULTS: In group I, the correlation coefficients between the different methods ranged from 0.82 to 0.94 except for SU-Segami (r=0.77), and were slightly lower for volumes than for LVEF. Mean differences between the methods were not significant, except for ECT, with which LVEF values were systematically higher by more than 10%. Changes in matrix size had no significant influence on LVEF or volumes. On the other hand, a sharper filter was associated with significantly larger volume values though this did not usually result in significant changes in LVEF. In group II, many patients had an LVEF in the higher range. The correlation coefficients between the different methods ranged between 0.80 and 0.96 except for SU-Segami (r=0.49), and were slightly worse for volumes than for LVEF values. In contrast to group I, however, inter-method variability was quite large and most mean LVEF differences were significant. LVEF was systematically highest with ECT and lowest with SU-Segami. With QGS, changes in matrix size from 64(2) to 128(2) were associated with significantly larger volumes as well as lower LVEF values. Increasing the filter cut-off frequency had the same effect. With SU-Segami, a larger matrix was associated with larger end-diastolic volumes and smaller ESVs, resulting in a highly significant increase in LVEF. Increasing the filter sharpness, on the other hand, had no influence on LVEF though the measured volumes were significantly larger. CONCLUSION: In patients with a normal-sized heart, LVEF and volume estimates computed from different commercially available software packages for quantitative gated SPECT are well correlated. LVEF and volumes are only slightly sensitive to changes in matrix size. Smoothing, by contrast, is associated with significant changes in volumes but usually not in LVEF values. However, owing to the specific characteristics of each algorithm, software should not be interchanged for follow-up in an individual patient. In small hearts, on the other hand, both the used software and the matrix size or smoothing significantly influence the results of quantitative gated SPECT. LVEF values in the higher range are frequently observed with all the studied software except for SU-Segami. A larger matrix or a sharper filter could be suggested to enhance the accuracy of most commercial software, more particularly in patients with a small heart.

Algorithms↗

Elastic surface contour detection for the measurement of ejection fraction in myocardial perfusion SPET.

The aim of this study was to investigate the use of an automated three-dimensional myocardial contour detection method using elastic surfaces for the assessment of left ventricular ejection fraction (EF) from electrocardiographically (ECG) triggered myocardial perfusion single-photon emission tomography (SPET). The validity of this method was studied on the basis of both phantom measurements and patient studies. Phantom measurements were performed using an elastic phantom of the left ventricle simulating a beating heart, with a simulated EF ranging from 10% to 78%. The data from 27 patients who had undergone both ECG-triggered myocardial perfusion SPET and planar gated radionuclide ventriculography (RNV) were used to compare the EF derived from the SPET data with the automated contour detection method and the EF derived from the RNV data with standard analysis software. EF values as measured by RNV ranged from 11% to 68%. The overall accuracy of the automated contour detection method proved to be very high. In the phantom study the deviation of the measured EF from the reference values was less than 4% for all of the simulated EFs. The studies on the patient data yielded a correlation coefficient (Pearson) greater than 0.94 as compared with planar RNV. Intra- and inter-observer reproducibility was high, with correlation coefficients exceeding 0.97. It is concluded that the proposed method allows accurate, reproducible and fast measurement of the left ventricular EF on the basis of myocardial perfusion SPET.

Algorithms↗

Sensitivity and specificity of nuclear phase analysis versus ejection fraction in coronary artery disease.

Phase standard deviation (SD) and skew characteristics of the first Fourier harmonic of equilibrium radionuclide volume curves were examined and compared during rest and during supine bicycle exercise with ejection fraction (EF) changes and the development of ischemia in 17 control subjects and in 2 groups of patients (n = 57) with coronary artery disease (CAD). Group I comprised 37 patients with CAD; IA was a subgroup of 20 patients with previous myocardial infarction (MI) and IB a subgroup of 17 patients with CAD without MI (all with coronary stenosis greater than 75% diameter narrowing). Group II comprised 20 patients with CAD who had undergone coronary bypass surgery. In the Group I subjects, phase SD was the most sensitive indicator of CAD at rest (Group I, 56%; Group IA, 70%, and Group IB, 29%), and the EF was the most sensitive indicator at submaximal (Group I, 78%; Group IA, 86%, and Group IB, 64%) and maximal exercise (Group I, 70%; Group IA, 93%, and Group IB, 53%). When phase SD and skewness were combined with EF changes, little increase in sensitivity occurred in Group I (rest 61%, submaximal exercise 88% and maximal exercise 76%). The results from Group II subgroups were qualitatively similar to those observed with Group I subgroups. These data reveal a marginally improved sensitivity for detection of CAD during supine bicycle radionuclide ventriculography when phase measurements were added to changes in global EF values.

Adult↗

Effects on hemodynamics and left ventricular ejection fraction of intravenous bepridil for impaired left ventricular function secondary to coronary artery disease.

To define the hemodynamic effects of bepridil in patients with depressed left ventricular (LV) function, 22 patients with an LV ejection fraction (EF) of 0.45 or less were studied before and after 2 mg/kg (n = 11) and 4 mg/kg (n = 11) of intravenous bepridil. Maximal hemodynamic effects were evident between 15 and 30 minutes after drug infusion. After 2 mg/kg, heart rate decreased 9% (p less than 0.01), cardiac index 17% (p less than 0.01), LV dP/dt max 16% (p less than 0.01), stroke work index 14% (p less than 0.01) and mean aortic pressure 8% (difference not significant). Right atrial pressure increased 8% (not significant), pulmonary arterial wedge pressure 24% (p less than 0.01) and systemic vascular resistance 17% (p less than 0.01). After administering 4 mg/kg of bepridil the changes in heart rate, cardiac index, right atrial pressure, LV dP/dt max, mean aortic pressure and systemic vascular resistance were almost identical to those after the smaller dose. The larger dose produced a 40% (p less than 0.01) increase in pulmonary arterial wedge pressure and a 22% decrease in stroke work index (p less than 0.01), but only the change in wedge pressure was significantly greater (p less than 0.01) than that produced by the lower dose. Radionuclide-determined LVEF decreased 6% (p less than 0.05), from 0.33 +/- 0.14 after 2 mg/kg and 11% (p less than 0.05) from 0.27 +/- 0.11 after 4 mg/kg of bepridil. The data indicate that bepridil exerts significant negative inotropic and chronotropic effects in patients with impaired LV function.

Adult↗

Effect of tissue harmonic imaging and contrast upon between observer and test-retest reproducibility of left ventricular ejection fraction measurement in patients with heart failure.

AIMS: To investigate the effects of tissue harmonic imaging (THI) and contrast chamber opacification (LVO) upon measurement variability and reproducibility of echocardiographic left ventricular (LV) volume and ejection fraction (EF) measurements in patients with heart failure (HF). BACKGROUND: Echocardiography is often used in HF patients to determine LV volumes and EF. However, current echo methods are variable and may not be applicable for repeat testing in individual patients. THI and LVO have both been shown to improve endocardial visualisation, but it remains to be determined whether this results in better measurement reproducibility. METHODS: Thirty-one HF patients and 30 control subjects underwent echocardiography on two separate days. LV volumes were measured under four different imaging conditions: fundamental, THI, LVO and LVO with ECG-triggered Power Doppler. Chamber opacification, pulmonary transit time (PTT), endocardial enhancement, reproducibility and bias were assessed. RESULTS: Chamber opacification was inferior and the PTT longer in the HF patients. PTT was related to LV volumes, EF, jugular venous pressure and mitral filling pattern. THI improved endocardial visualisation, and although LVO improved endocardial visualisation in the controls, it offered no benefit over THI in the HF patients. LV volumes and EF were different for each method and THI was the least variable method for repeat measurements. CONCLUSIONS: THI improved endocardial visualisation and was the least variable of the techniques. LVO offered no further advantage in patients with HF and thus cannot be routinely advocated and since LV volumes and EF were different for each, these methods are neither comparable nor interchangeable for follow-up assessments.

Contrast Media↗

Correlation of resting first-pass left ventricular ejection fraction and resting myocardial infarct size.

This study determined the correlation between the extent of the resting perfusion defect by technetium-99m sestamibi tomographic imaging and the first-pass left ventricular (LV) ejection fraction (EF). A total of 1,955 patients underwent technetium-99m sestamibi tomographic imaging with measurement of first-pass resting LVEF. Twenty-five percent of patients had a prior history of myocardial infarction. First-pass LVEF was measured using a peripheral intravenous injection and a multicrystal gamma camera with standard software. Resting tomographic perfusion defect size (infarct size) was quantitated using previously published methods. Mean LVEF for the study group was 0.60 +/- 0.11. Mean LV infarct size was 5 +/- 11%. For the 1,265 patients (65% of the study group) with no measurable perfusion defect, the prevalence of a normal (> or = 0.50) LVEF was 96% (1,212 of 1,265 patients). For patients with a measurable defect (n = 690, 35%), the inverse linear correlation with LVEF was highly significant (r = -0.60, p <0.0001) but with wide confidence limits (SEE = 10 LVEF points), thereby limiting the predictive value in individual patients. Thus, in the absence of known cardiomyopathy, valvular heart disease, or left bundle branch block, patients without a quantifiable resting perfusion defect are highly likely to have a normal resting LVEF and may not require determination of LV function. For patients with resting perfusion defects, LVEF cannot be predicted with confidence and should therefore be measured.

Aged↗

Efficacy of high-intensity exercise training on left ventricular ejection fraction in men with coronary artery disease (the Training Level Comparison Study).

The purpose of this study was to compare high- versus low-intensity exercise training on the change in echocardiographic left ventricular ejection fraction (LVEF) from rest to peak exercise. Sedentary men with coronary artery disease, aged 30 to 70 years, were randomized to dynamic exercise training of either low intensity, 50% of maximal oxygen consumption, n = 89; or high intensity, 85% of maximal oxygen consumption, n = 111. No other interventions were imposed and patients were evaluated at 6 months and 1 year. Both exercise groups significantly increased exercise capacity without adverse events, but the increase was greater (p = 0.02) in the high-intensity exercise group. The mean exercise test rest-peak LVEF in the high-intensity group rose from 6.20% at baseline to 6.54% in 6 months and to 6.73% at 12 months, while the low-intensity group showed no improvement at 6 months and a decrease at 12 months. Multivariate analyses revealed that treatment group (high versus low intensity) significantly contributed to the change in rest-peak LVEF. When the exercise groups were subdivided by initial baseline LVEF < or = 50% versus > 50%, those with the higher LVEF in the high-intensity group showed a greater (p = 0.05) increase in the rest-peak LVEF from baseline to 1 year. Over a 1-year period, exercise capacity improved in both exercise-intensity groups, but more so in the high-intensity group, with no adverse events. The high-intensity group, compared with the low-intensity, showed more improvement in the rest-peak LVEF, especially in those with a higher LVEF at baseline.

Adult↗

Coronary artery bypass grafting in patients with an ejection fraction of twenty percent or less.

Over a 7-year period, 5.8% (n = 210) of patients who underwent coronary artery bypass grafting at our institution had severely impaired global left ventricular function with an ejection fraction of 20% or less. Mean age at operation was 66 years (+/- 0.7; standard error), and 76% of patients were male. Primary indications for operation were unstable angina (73 patients, 35%), return of symptoms with previous bypass grafting (41 patients, 20%), congestive heart failure with reversible ischemia (55 patients, 26%), and recurrent ventricular arrhythmias (41 patients, 20%). Overall, actuarial survival (n = 210) was 82%, 79%, and 73% at 1, 2, and 5 years. Risk of death was highest early after the operation, and then declined rapidly to a constant level. Patients who did not receive retrograde coronary sinus cardioplegia (p = 0.05), older patients (p = 0.004), and those with preoperative ventricular arrhythmias (p = 0.003) or renal failure (p < 0.0001) had an increased risk of death early after operation. Patients with congestive symptoms and those requiring extensive or redo bypass grafting (p = 0.02) were found to be at an increased risk of death throughout the follow-up period. When the number of distal anastomoses performed increased, survival was found to decrease (p < 0.003), and to a greater extent in women than in men (p = 0.02). Of the four primary indications for operation, unstable angina yielded the highest risk-adjusted survival. Successful results after surgical revascularization in patients with severe impairment of ventricular function can be achieved by careful patient selection and management.

Aged↗

Relationship between right ventricular ejection fraction and maximum exercise oxygen consumption: a methodological study in chronic heart failure patients.

BACKGROUND: Peak oxygen consumption at maximum exercise (peak VO(2)) predicts survival in chronic heart failure (CHF) patients. Right ventricular ejection fraction (RVEF) at rest has been reported to correlate with peak VO(2). We evaluated the strength and consistency of the association between peak VO(2) and RVEF measured by different radionuclide ventriculography (RNV) techniques in a prospective cohort study. METHODS AND RESULTS: In 58 consecutive CHF patients (mean age, 53 years; 39 patients with dilated cardiomyopathy; 48 men), upright symptom-limited bicycle ergometry was performed. During exercise, ventilatory and gas exchange data were recorded and peak VO(2) was calculated. RVEF was calculated by use of first-pass (FP) RNV with single and dual region of interest (ROI) acquisition and planar multigated acquisition (MUGA). Irrespective of the method used, RVEF showed no relevant correlation with the corresponding peak VO(2) value (r = 0.11 for FP single ROI, r = 0.06 for FP dual ROI, r = 0.16 for MUGA). Peak VO(2) or changes in peak VO(2) after 6 and 12 months of follow-up were not determined by RVEF measurements. CONCLUSION: In CHF patients no association was found between peak VO(2) at maximum exercise and RVEF at rest with different RNV techniques. Changes in exercise capacity are not reliably reflected by changes in RVEF measurements at rest.

Adult↗

Repeatability of treadmill exercise ejection fraction and wall motion using technetium 99m-labeled sestamibi first-pass radionuclide ventriculography.

BACKGROUND: Peak treadmill exercise radionuclide ventriculography (RVG) with technetium 99m has recently been validated for determination of left ventricular ejection fraction (LVEF). However, the repeatability of this technique for determination of both LVEF and regional wall motion has not been reported. METHODS AND RESULTS: Each of 27 clinically stable patients underwent two treadmill exercise RVG studies within 40 +/- 51 days. The level of exercise achieved in the two tests was similar (double product: 26,357 +/- 3877 vs 26,621 +/- 4287), and there was no change in clinical or treatment status between the studies. Acquisition and processing were accomplished with a mobile multicrystal camera and a new version of a commercial software (Scinticor SIM 400 V. 4.1 BETA, Milwaukee, Wis.) that uses two left ventricular regions of interest. The two tests were compared to assess agreement (repeatability) on both an automatically calculated LVEF and wall motion in five left ventricular segments (basal anterior, distal anterior, apical, distal inferior, and basal inferior), with a 3-point semiquantitative visual score. Intraobserver and interobserver agreements (reproducibility) also were assessed on quantitative exercise LVEF derived from the same RVG test from a separate group of 20 patients with a broad range of exercise LVEF. The first and second treadmill exercise LVEFs were highly correlated (r = 0.92, SEE = 3.96, y = 0.97x + 0.58; and r = 0.99, SEE = 1.32, y = 0.99x + 0.25, respectively). Results of segmental visual score agreement between the first and the second treadmill first-pass studies were as follows: overall, 86% (116/135, kappa = 0.74); basal anterior, 85% (23/27, kappa = 0.72); distal anterior, 85% (23/27, kappa = 0.84); apical, 93% (25/27, kappa = 0.85); distal inferior, 93% (25/27, kappa = 0.80); and basal inferior, 67% (18/27, kappa = 0.64). CONCLUSION: Treadmill exercise first-pass RVG is a highly repeatable and reproducible test for quantitative LVEF and visual regional wall motion analysis. Our results imply the procedure may be useful for serial follow-up of patients with coronary artery disease and for the evaluation of the efficacy of medical or interventional treatment.

Adult↗

Monitoring of left ventricular ejection fraction with a miniature, nonimaging nuclear detector: accuracy and reliability over time with special reference to blood labeling.

BACKGROUND: The purpose of this study was to determine the accuracy of determinations of left ventricular ejection fraction (LVEF) by a nonimaging miniature nuclear detector system (Cardioscint) and to evaluate the feasibility of long-term LVEF monitoring in patients admitted to the coronary care unit, with special reference to the blood-labeling technique. METHODS AND RESULTS: Cardioscint LVEF values were compared with measurements of LVEF by conventional gamma camera radionuclide ventriculography in 33 patients with a wide range of LVEF values. In 21 of the 33 patients, long-term monitoring was carried out for 1 to 4 hours (mean 186 minutes), with three different kits: one for in vivo and two for in vitro red blood cell labeling. The stability of the labeling was assessed by determination of the activity of blood samples taken during the first 24 hours after blood labeling. The agreement between Cardioscint LVEF and gamma camera LVEF was good with automatic background correction (r = 0.82; regression equation y = 1.04x + 3.88) but poor with manual background correction (r = 0.50; y = 0.88x - 0.55). The agreement was highest in patients without wall motion abnormalities. The long-term monitoring showed no difference between morning and afternoon Cardioscint LVEF values. Short-lasting fluctuations in LVEFs greater than 10 EF units were observed in the majority of the patients. After 24 hours, the mean reduction in the physical decay-corrected count rate of the blood samples was most pronounced for the two in vitro blood-labeling kits (57% +/- 9% and 41% +/- 3%) and less for the in vivo blood-labeling kit (32% +/- 26%). This "biologic decay" had a marked influence on the Cardioscint monitoring results, demanding frequent background correction. CONCLUSION: A fairly accurate estimate of LVEF can be obtained with the nonimaging Cardioscint system, and continuous bedside LVEF monitoring can proceed for hours with little inconvenience to the patients. Instability of the red blood cell labeling during long-term monitoring necessitates frequent background correction.

Erythrocytes↗

An enhanced method for left ventricular volume and ejection fraction by triggered harmonic contrast echocardiography.

To elucidate the validity and reproducibility of the use of intravenous echo-contrast agent in the evaluation of left ventricular (LV) performance, we measured LV volume and ejection fraction (EF) in 42 patients with triggered harmonic contrast imaging (THCI), compared with continuous harmonic imaging without contrast agent (CHI) and with cineventriculography (CVG). In 10 of 42 patients, THCI improved LV border delineation which could not be obtained even with CHI. LV end-diastolic, end-systolic volumes and EF by both CHI and THCI correlated well with those by CVG. Although LV volumes are underestimated, THCI lessened the mean differences to about in half, compared with CHI. The observer variabilities obtained using THCI were smaller than those by CHI. These results indicate the validity of LV enhancement and the measurement of EF using THCI. We suggest that this method noninvasively provides more accurate LV systolic function with the acceptable reproducibility.

Aged↗

Marked improvement in left ventricular ejection fraction during long-term beta-blockade in patients with chronic heart failure: clinical correlates and prognostic significance.

BACKGROUND: Some patients with heart failure (HF) may have a marked improvement in left ventricular ejection fraction (LVEF) after long-term beta-blockade. We compared the clinical characteristics and the prognosis of these patients with those of other patients. METHODS: One hundred seventy-one patients with chronic HF were assessed before and after 9 to 12 months of maintenance therapy with metoprolol or carvedilol. RESULTS: Thirty-eight patients (22%) showed an increase in their LVEF >or=15 units (from 20% +/- 8% to 43% +/- 10%). Compared with the other patients (LVEF change from 21% +/- 7% to 26% +/- 9%, P <.0001 for differences between groups), these patients also had a greater decline in the left ventricular end-diastolic volume (from 175 +/- 74 mL/m(2) to 113 +/- 36 mL/m(2)) and in the right atrial, mean pulmonary artery, and pulmonary wedge pressures, with a greater increase in the cardiac index, stroke volume index, stroke work index, and maximal functional capacity. Their long-term prognosis was excellent, with a 2-year cumulative survival rate of 95%, versus 81% for the other patients, and a hospitalization-free survival rate of 73%, versus 50% for the other patients (all P <.05). By means of multivariate analysis, only the nonischemic cause of HF and the mean arterial pressure at baseline were independently associated with an increase of >or=0.15 in LVEF. CONCLUSIONS: Patients who show a marked improvement in their LVEF after long-term beta-blockade have an excellent prognosis and have a high prevalence of nonischemic HF and a higher blood pressure at baseline.

Adrenergic beta-Antagonists↗

Assessment of left ventricular ejection fraction with quantitative gated SPECT: accuracy and correlation with first-pass radionuclide angiography.

BACKGROUND: Quantitative gated single photon emission computed tomography (SPECT [QGS]) software is widely used for the assessment of left ventricular ejection fraction (LVEF). Potentially confounding variables that may affect the accuracy of quantitative analysis of LVEF remain undefined. This study evaluated the accuracy of QGS as a means of determining LVEF in a wide range of LVEF values; evaluated the effect of extracardiac activity, count statistics, heart size, and perfusion defects on the accuracy of QGS LVEF; and compared QGS LVEF obtained at rest with that obtained after stress. METHODS AND RESULTS: QGS-derived LVEF was compared with rest first-pass radionuclide angiography (FPRNA) LVEF in 400 electrocardiographic-gated SPECT studies. The overall correlation between QGS and FPRNA LVEF was only fair (r = 0.66, SEE = 11.85%). In 35 of the patient studies (9%) with high extracardiac activity, the automated software failed, and no correlation was obtained. In the remaining 365 patient studies (91%), left ventricular contours were successfully identified. In these studies, correlation was better (r = 0.74, SEE = 9.77%). Agreement was better for images with high counts (r = 0.81, SEE = 8.66%) than for images with low counts (r = 0.61, SEE = 11.17%). Patient studies with abnormal LVEF had better correlation (r = 0.77, SEE = 6.4%) than studies with normal LVEF (r = 0.46, SEE = 10.2%). Agreement between QGS LVEF and FPRNA LVEF was better in hearts with large end diastolic volumes (>104 mL) than in hearts with small volumes. Overall, mean QGS LVEF was lower than mean FPRNA LVEF (54%+/-14% vs. 58%+/-14%, P<.0001). There was no difference between mean rest and stress QGS LVEF in the same patients, even in patients with stress-induced ischemia. CONCLUSIONS: QGS is a valuable method for assessing resting LVEF. However, QGS LVEF is often lower than FPRNA LVEF. Accuracy is affected by high extracardiac activity, low count density, and small size of the left ventricle.

Adult↗

Relationship between various parameters derived from 123I-labelled beta-methyl-branched fatty acid whole-body scintigraphy and left ventricular ejection fraction in patients with ischaemic heart disease.

Heart uptake and clearance of 123I-15-(p-iodophenyl)-3(R,S)-methyl- pentadecanoic acid (BMIPP) by whole-body scintigraphy in relation to left ventricular ejection fraction (LVEF) was evaluated in 34 patients with ischaemic heart disease. At 45 and 210 min after injection, anterior whole-body images were obtained. In each patient, multigated blood pool scintigraphy was also performed, and LVEF was calculated. The percentage heart uptake of BMIPP did not have a significant correlation with LVEF (R = -0.299, NS). In contrast, there was a positive correlation between LVEF measured by multigated blood pool scintigraphy and BMIPP count density of the heart (R = 0.467, P = 0.005). Myocardial BMIPP washout rate also positively correlated with LVEF (R = 0.472, P = 0.005). In addition to these observations, there was a positive correlation between the BMIPP count density of the heart and myocardial BMIPP washout rate (R = 0.0543, P = 0.001). Thus, the BMIPP count density of the heart and myocardial BMIPP washout rate derived from BMIPP whole-body scintigraphy directly correlated with LVEF. However, the correlations between these parameters and LVEF were not strong enough to allow left ventricular dysfunction to be assessed precisely.

Adult↗

A circulating myocardial depressant substance in humans with septic shock. Septic shock patients with a reduced ejection fraction have a circulating factor that depresses in vitro myocardial cell performance.

We have previously described a subpopulation of patients with septic shock who had a reversible depression of radionuclide-determined left ventricular ejection fraction (EF). To investigate the mechanism of this myocardial depression, an in vitro model of mammalian myocardial cell performance was established employing primary spontaneously beating rat myocardial cells. The contraction of a single cardiac cell was quantitated by recording the changes in area occupied by the cell during contraction and relaxation. In 20 septic shock patients during the acute phase, the mean left ventricular EF was decreased (mean = 0.33, normal mean = 0.50), and serum obtained during this acute phase induced a mean (+/- standard error of the mean) 33 +/- 4% decrease in extent and 25 +/- 4% decrease in velocity of myocardial cell shortening during contraction (P less than 0.001). In contrast, serum obtained from 11 of these same patients before shock (n = 2) or after recovery (n = 9) of the left ventricular EF (mean = 0.50) showed a return toward normal in extent and velocity of shortening (P less than 0.001). Sera from 17 critically ill nonseptic patients, from 10 patients with structural heart disease as a cause for a depressed EF, and from 12 healthy laboratory personnel, induced no significant changes in in vitro myocardial cell performance. In 20 patients during the acute phase of septic shock, the decreased EF in vivo demonstrated a significant correlation (r = +0.52, P less than 0.01) with a decrease in the extent of myocardial cell shortening in vitro. The quantitative and temporal correlation between the decreased left ventricular EF and this serum myocardial depressant substance argues for a pathophysiologic role for this depressant substance in producing the reversible cardiomyopathy seen during septic shock in humans.

Adolescent↗

Prone versus supine patient positioning during gated 99mTc-sestamibi SPECT: effect on left ventricular volumes, ejection fraction, and heart rate.

UNLABELLED: Gated myocardial perfusion SPECT allows assessment of left ventricular end-diastolic volume (EDV), left ventricular end-systolic volume (ESV), left ventricular stroke volume (SV), and left ventricular ejection fraction (LVEF). Acquiring images with the patient both prone and supine is an approved method of identifying and reducing artifacts. Yet prone positioning alters physiologic conditions. This study investigated how prone versus supine patient positioning during gated SPECT affects EDV, ESV, SV, LVEF, and heart rate. METHODS: Forty-eight patients scheduled for routine myocardial perfusion imaging were examined with gated (99m)Tc-sestamibi SPECT (at rest) while positioned prone and supine (consecutively, in random order). All parameters for both acquisitions were calculated using the commercially available QGS algorithm. RESULTS: Whereas EDV and SV were significantly lower (P < 0.0004) for prone acquisitions (EDV, 110.5 +/- 39.1 mL; SV, 55.9 +/- 13.3 mL) than for supine acquisitions (EDV, 116.9 +/- 36.2 mL; SV, 61.0 +/- 14.5 mL), ESV and LVEF did not differ significantly. Heart rate was significantly higher (P < 0.0001) during prone acquisitions (69.1 +/- 10.5 min(-1)) than during supine acquisitions (66.5 +/- 10.0 min(-1)). CONCLUSION: The observed position-dependent effect on EDV, SV, and heart rate might be explained by decreased arterial filling and increased sympathetic nerve activity. Hence, supine reference data should not be used to classify the results of prone acquisitions.

Adult↗

Left ventricular volume and ejection fraction determination by cross-sectional echocardiography in patients with coronary artery disease: a prospective study.

In a prospective study the accuracy of cross-sectional echocardiography for determination of left ventricular (LV) volume and ejection fraction (EF) was analyzed in 53 patients with coronary artery disease and compared to that of cineangiocardiography (angio). From the apex of the heart phased-array wide-angle (84 degrees) electronic echocardiograms were received in the RAO-equivalent view. Angios were obtained in a 30 degree RAO view. Using Simpson's rule, end-diastolic (EDV) and end-systolic (ESV) LV volumes were calculated and the EF derived. Left ventricular long axis was transected in eight segments, yielding seven diameters. In 50 of the 53 patients cross-sectional echocardiograms could be recorded. The correlation between cineangiocardiography and cross-sectional echocardiography for EDV was highly significant: r = 0.936, y = 0.667x + 27.1, standard error of estimate (syx) +/- 22.2 ml; for ESV: r = 0.970, y = 0.699x + 14.7, syx +/- 14.5 ml; for stroke volume: r = 0.721, y = 0.503x + 11.3, syx +/- 15.3 ml; for EF: r = 0.909, y = 0.740x + 11.3, syx +/- 6.0%. Angio mean long axis was 10.2 +/- 1.2 cm, cross-sectional echocardiographic long axis 8.7 +/- 1.3 cm. Mean LV diameter determined by cineangiocardiography was longer than when determined by cross-sectional echocardiography. The mean difference reached 2.0 cm in the middle of the LV. Our prospective comparative study revealed that LV volumes and EF were underestimated by cross-sectional echocardiography compared to cineangiocardiography because of a methodological systematic error caused by a tangential cut of the heart. In the RAO-equivalent view the "true" long axis was missed. The high corrleation coefficients, however, indicate that the "true" LV volume and EF can be calculated from the given regression equation. Serial measurements should be legitimated.

Angiocardiography↗