PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Particle Size”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Aerosol vaccination against Newcastle disease. I. Studies on particle size.

Studies revealed that the majority of particles emitted by three different aerosol generators were in the size ranges of 0.5-1 and 1-3 mum. In general, the smaller the aperture setting, the larger the total number of particles. The difference between the generators in number of particles emitted were not significant enough to produce appreciable difference in antibody titers obtained from vaccinated chickens. Antibody titers were higher in birds vaccinated with the LaSota strain of Newcastle disease virus than in birds vaccinated with the B-1 strain, although protection against challenge was approximately similar. Aerosol challenge was found as effective as intramuscular challenge.

Aerosols↗

Particle size of hydroxyapatite granules calcified from red algae affects the osteogenic potential of human mesenchymal stem cells in vitro.

Hydroxyapatite (HA) microparticles as a carrier in an injectable tissue-engineered bone filler are considered promising candidates for the treatment of small bone defects in the craniomaxillofacial region. HA granules calcified from red algae, varying in size, were evaluated in vitro for their suitability to be used as a carrier for human mesenchymal stem cells (hMSCs). Three groups of granules were produced in grain sizes of 10-100, 200-500 and 600-1,000 mum. After seeding and culturing hMSCs under osteogenic differentiation conditions onto HA particles for 3, 6 and 9 days, cellular proliferation (tetrazolium salt, XTT), alkaline phosphatase (ALP)-specific activity and total protein synthesis were investigated. The osteoblastic phenotype of the cells was evaluated by assaying the bone-specific genes osteocalcin, osteopontin and collagen type I. XTT assay revealed significantly higher (p < 0.01) proliferation of cells grown on the smallest grain size after 9 days of culture. Regarding ALP-specific activity, significantly higher levels of activity were detected in cells grown on the smallest grain size. Different grain sizes had no significant effects on the secretion of osteocalcin and osteopontin. Collagen type I production was significantly higher (p < 0.05) in cells grown on the biggest grain size in comparison with the two other grain sizes. These results show that the particle size of HA microparticles affects the osteogenic potential of cultured hMSCs and lead to the conclusion that particle size has differential effects on ALP-specific activity and collagen type I production.

Alkaline Phosphatase↗

Crystallization in Polyamide 6/Polysulfone Blends: Effect of Polysulfone Particle Size.

By reactive blending of polyamide 6 (PA) with polysulfone (PSU) using a gram-scale mixer (Mini-Max Molder), we prepared a series of PA/PSU (80/20 wt.ratio) with various diameters of PSU particles: 90 nm by using phthalic anhydride-terminated PSU (PSU-PhAH), 0.2 µm by carboxylic acid-grafted PSU (PSU-COOH), and 1.0 µm by nonreactive PSU (nf-PSU). Isothermal crystallization was carried out at 200 degreesC. Light scattering studies showed that spherulites in the blends can grow to more than 10 µm in diameter, as in the case of neat PA. It suggests that crystal growth in the radial direction can be achieved by circumventing the PSU obstacles; i.e., it does not matter how big or small they are in the range of 90 nm to 1 µm. The smaller the PSU particles, the slower was the overall rate of crystallization. The slower rate may be caused by the higher population of brush PA chains attached to PSU particles as block or graft chains, since the brushes may be hard to organize into crystal lamellae, compared with free chains. The blends showed rather broad wide-angle X-ray diffraction profiles. The smaller the PSU particles, the broader was the profile. The scattering from the particles themselves should appear only at extremely low angles (<0.1 degrees) and hardly affects the wide-angle X-ray profiles so that the results may imply that the presence of smaller PSU particles renders the less perfection of the PA crystal. This may be caused also by the higher population of brush chains. Note that the brush chains are formed only in the reactive systems and the population may be higher in the smaller particle systems. Even for the blend with smallest particle size, a small-angle X-ray scattering peak appeared at a magnitude of scattering vector of approximately 0.8 nm-1, suggesting the evolution of interlamellar spacing of 8.7 nm. However, the scattering profile was much broader than that of neat PA. It implies a less ordered lamellar stacking in the blend.

Journal Article↗

Formation of monodisperse polyacrylamide particles by radiation-induced dispersion polymerization: particle size and size distribution.

Polyacrylamide microparticles were directly produced by radiation-induced dispersion polymerization in aqueous alcohol media using poly(N-vinylpyrrolidone) as a steric stabilizer at room temperature. The hydrodynamic diameter of a polymer particle and its distribution were measured on a dynamic laser light-scattering spectrometer. This method takes advantages of the specialties of radiation induction, and highly uniform polymer microspheres were obtained with high conversion. The number of the particle produced in the early stage of the polymerization was found to be constant during the remainder of the polymerization. The effects of various polymerization parameters, such as absorbed dose rate, monomer concentration, stabilizer content, medium polarity, and polymerization temperature on the particle size and size distribution were systematically investigated.

Journal Article↗

Effect of particle size and lipid composition of bovine blood high density lipoprotein on its function as a carrier of beta-carotene.

As part of a study on the influence of dietary lipids on vitamin transport and metabolism in lactating cows, we have examined the beta-carotene content and other properties of fractions of the high-density lipoprotein (HDL, density 1.05-1.16 g/ml) of bovine blood. Our purpose was primarily to explain previous results indicating that feeding cows polyunsaturated lipids alters the properties of the HDL and increases the concentration of beta-carotene in the blood but not in the milk. Fractions of HDL of different particle size were prepared by gel-filtration chromatography and the particle diameters measured by electron microscopy. We found that large HDL particles contain more beta-carotene per unit weight than small particles. Furthermore the HDL from cows fed lipid-rich diets with a high proportion of linoleic-acid residues, which had been protected against microbial degradation in the rumen, had a high percentage of HDL particles with large diameters. The blood from these cows had a higher concentration of beta-carotene than before feeding polyunsaturated lipids, but their milk had a lower concentration. We suggest that HDL is the main store of beta-carotene in bovine blood. Moreover the concentration of beta-carotene in blood is increased by feeding polyunsaturated lipids largely because of the increase in the percentage of large HDL particles, which contain more beta-carotene. The effect on the concentration of beta-carotene in milk implies that the transfer mechanism is less efficient as a result of feeding polyunsaturated lipids. This lower efficiency may be due in part to the higher percentage of large HDL particles.

Animals↗

Electrospray encapsulation of water-soluble protein with polylactide. I. Effects of formulations and process on morphology and particle size.

Bovine serum albumin (BSA) was encapsulated with poly (lactide) (PLA) using an electrospray technique in which a sufficiently strong electric field was applied to overcome the surface tension of a droplet and to produce small particles. The influences of PLA solvent type, PLA solution concentrations; the viscosity, electrical conductivity and surface tension of PLA solutions and PLA/BSA emulsions; and the applied voltage and flow rate on the morphology and size of the BSA-loaded PLA particles were examined. 1,2-dichloroethane (DCE) was a better solvent for PLA than dichloromethane. Spherical electrosprayed particles, with smooth surfaces, were observed with both solvents. The electrical conductivity increased and particle size decreased when acetone was mixed with DCE as PLA solvent. However, the particles were no longer spherical. The size of the particles increased and shape became spherical as PLA concentration was increased from 1-3%. Increasing the concentration to 4% resulted in the formation of a mixture of beads and fibres. Particle size decreased as applied voltage was increased from 10-15 kV and increased as flow rate was increased from 0.5-3 ml h(-1).

Chemistry, Pharmaceutical↗

Repeptization Determined by Turbidity and Photon Correlation Spectroscopy Measurements: Particle Size Effects

The aggregation of four polystyrene latexes with similar surface charge and different diameter has been examined by small angle light scattering. The DLVO model including aggregation at the secondary minimum qualitatively agrees with the experimental dependence of colloidal stability on particle size. Repeptization experiments, where the flocs were redispersed by washing away the coagulating salt, were carried out using two different methods: dialysis-turbidity and dilution-photon correlation spectroscopy. It was found that for the larger latexes the aggregates fragment after dilution, while for the smaller latexes the aggregates do not fragment. These results correlate closely with the hypothesis that particles may be captured within the secondary minimum of the theoretical interaction energy curves. Copyright 1997 Academic Press. Copyright 1997Academic Press

Journal Article↗

Particle size and refractive index retrieval from the backscattering spectrum of white light using the Twomey iterative method: simulation and experiment.

The Twomey iterative method has been applied to the retrieval of hydrosol microphysical properties. In particular, we focused on the retrieval of single and multimode particle size distributions from both simulated and experimental backscattering spectra in the 400-800 nm wavelength range. Assuming a known refractive index, both single-mode and multimode distributions were successfully retrieved through the introduction of an initial distribution biased toward larger particles. The simulation results were experimentally verified with standard polystyrene particles suspended in water within the diameter range of 0.2-2 microm for both narrow and broad monomodal distributions as well as more complicated multimode distributions. Finally, the technique was extended to the retrieval of an unknown refractive index.

Journal Article↗

Asymptotic Particle Size Distributions Attained during Coagulation Processes.

The effects of the collision kernel on the self-preserving size distribution and on the gelation phenomenon of aerosol coagulation were investigated. An analytical solution for the asymptotic width of log-normally preserving size distribution during coagulation was obtained as a function of the degree of homogeneity using arbitrary shape of homogeneous collision kernels. From the solution obtained, it was shown that when the degree of homogeneity is larger than 1, self-preserving size distribution does not exist, and gelation occurs. A very accurate numerical coagulation simulation method, the sectional method, was also used for calculating the self-preserving particle size distribution for some specific classes of coagulation kernels and the results were compared with the analytical solution obtained by the log-normal method. Copyright 2001 Academic Press.

Journal Article↗

Experimental validation of a combined electromagnetic and thermal model for a microwave drying of capillary porous materials inside a rectangular wave guide (effects of irradiation time, particle sizes and initial moisture content).

In this paper, the experimental validation of a combined electromagnetic and thermal model for a microwave drying of capillary porous materials inside a rectangular wave guide is presented. The effects of the irradiation time, particle sizes and the variation of initial moisture content on the microwave drying kinetics are clarified in detail, considering the interference between incident and reflected waves in the capillary porous materials. The established model has allowed us to determine the space-time evolution of electric field, temperature and moisture content within capillary porous materials during microwave drying process.

Journal Article↗

Remote sensing of cirrus cloud optical thickness and effective particle size for the National Polar-orbiting Operational Environmental Satellite System Visible/Infrared Imager Radiometer Suite: sensitivity to instrument noise and uncertainties in environmental parameters.

We describe sensitivity studies on the remote sensing of cirrus cloud optical thickness and effective particle size using the National Polar-orbiting Operational Environmental Satellite System Visible/Infrared Imager Radiometer Suite 0.67-, 1.24-, 1.61-, and 2.25-microm reflectances and thermal IR 3.70- and 10.76-microm radiances. To investigate the accuracy and precision of the solar and IR retrieval methods subject to instrument noise and uncertainties in environmental parameters, we carried out signal-to-noise ratio tests as well as the error budget study, where we used the University of California at Los Angeles line-by-line equivalent radiative transfer model to generate radiance tables for synthetic retrievals. The methodology and results of these error analyses are discussed.

Journal Article↗

[Influence of auxiliary materials on the proportion of effective particle size of metered-dose suspension type aerosols].

The aim of the present study was to formulate suspension type inhalation aerosols by various types of auxiliary materials, and to select the formulation with the highest proportion of the effective particle size. The examined suspension type aerosol contained sodium cromoglycate as an active compound. For the stabilization of the suspension, the applied surface active ingredients were oleic acid and oleyl oleate, and dimethyl siloxane polymer was selected as hydrophobizing agent. Factorial design was used for the optimization of the experimental results. On the basis of our results, the correct types and amounts of auxiliary materials can be selected to obtain the therapeutically effective formulation.

Administration, Inhalation↗

Separation efficiency and particle size distribution in relation to manure type and storage conditions.

Mechanical separation of liquid animal manure can be an effective technique for production of a liquid and a nutrient-rich solid fraction. The efficiency of separators depends on the physical and chemical composition of the animal manure. Therefore, the particle size composition was measured for different types of manure before treatment with a decanting centrifuge and a screw press. Storage of pig manure reduces the total dry matter content, and the content of small particles (< 0.0016 mm) is reduced more than the content of large particles. In consequence, the proportion of large particles will increase, while the portion of small particles will decrease. The separation efficiency of the screw press was found to be low, as this separator only retains particles > 1 mm. The decanter centrifuge retained all the particles > 0.02 mm and was therefore much more efficient than the screw press. Separation efficiency was also found to be highly dependent on the type of manure used.

Agriculture↗

Fiber-like Gold Particles Prepared in Cationic Micelles by UV Irradiation: Effect of Alkyl Chain Length of Cationic Surfactant on Particle Size.

Fiber-like gold particles were prepared by irradiation of HAuCl(4) solutions at 253.7 nm in the presence of alkyltrimethylammonium chlorides (C(n)TAC: n=10, 12, 14, and 16). Fiber-like gold particles were obtained above a threshold concentration of C(n)TAC. The length of fiber-like gold particles increases with increasing alkyl chain length of C(n)TAC. Copyright 2001 Academic Press.

Journal Article↗

Acute pulmonary toxicity caused by exposure to colloidal silica: particle size dependent pathological changes in mice.

To compare the pulmonary toxicity between ultrafine colloidal silica particles (UFCSs) and fine colloidal silica particles (FCSs), mice were intratracheally instilled with 3 mg of 14 nm UFCSs and 230 nm FCSs and pathologically examined from 30 minutes to 24 hour postexposure. Histopathologically, lungs exposed to both sizes of particles showed bronchiolar degeneration and necrosis, neutrophilic inflammation in alveoli with alveolar type II cell swelling and particle-laden alveolar macrophage accumulation. UFCSs, however, induced extensive alveolar hemorrhage compared to FCSs from 30 minutes onwards. UFCSs also caused more severe bronchiolar epithelial cell necrosis and neutrophil influx in alveoli than FCSs at 12 and 24 hours postexposure. Laminin positive immunolabellings in basement membranes of bronchioles and alveoli of UFCSs treated animals was weaker than those of FCSs-treated animals in all observation times. Electron microscopy demonstrated UFCSs and FCSs on bronchiolar and alveolar wall surface as well as in the cytoplasm of alveolar epithelial cells, alveolar macrophages and neutrophils. Type I alveolar epithelial cell erosion with basement membrane damage in UFCSs treated animals was more severe than those in FCSs-treated animals. At 12 and 24 hours postexposure, bronchiolar epithelial cells in UFCSs-treated animals showed more intense vacuolation and necrosis compared to FCSs-treated animals. These findings suggest that UFCSs have greater ability to induce lung inflammation and tissue damages than FCSs.

Animals↗

Composite interfacial layers containing micro-size and nano-size particles.

Surface layers of micro- and nanoparticles at fluid/liquid interfaces in absence and presence of surfactants are of large importance in the process of re-discovering Pickering systems, i.e. emulsions and foams stabilized by particles. The surface pressure/area isotherms of such layers can provide information about the properties of the used particles (dimensions, interfacial contact angles), the structure of interfacial layers, the interactions between the particles as well as about relaxation processes within the layers. For a correct description of Pi-A isotherms of composite surface layers containing particles the significant difference in size of these particles to that of solvent and surfactant molecules should be taken into account. Corresponding equations can be derived on the basis of the two-dimensional solution theory. The gained equations provide satisfactory agreement with experimental data and predict realistic values for the area of particles at the interface. Also equations of state and of the dilational elasticity for composite surface layers containing particles can be obtained in the framework of the presented methodology.

Adsorption↗

Particle size characterization and the indoor-to-outdoor relationship of atmospheric aerosols in Helsinki.

OBJECTIVES: The influence of traffic and meteorological conditions on aerosol characteristics outdoors, the relationship between indoor and outdoor aerosol particles, and the pollutant transport indoors by means of a mechanical ventilation system were studied. METHODS: Indoor and outdoor concentrations of fine-particle numbers were measured during the summer (15 May--30 June 2000) in one office located in the basement of a building in Helsinki, Finland. The total number concentration was measured with a condensation particle counter, and the particle number size distribution (7-600 nm) was measured with a differential mobility particle sizer. The size distribution (0.3-25 microm) of the indoor particle numbers was periodically measured with a laser particle counter. RESULTS: Meteorological conditions, especially wind direction, had the greatest effect on the total number concentration and the size distribution of aerosol particles outdoors. The outdoor number concentration of ultrafine particles (diameter <100 nm) was strongly dependent on traffic density. The temporal variations in the indoor number concentration of ultrafine and fine particles (7-600 nm) closely followed the corresponding temporal variations outdoors. The building ventilation system was the main means of transporting aerosols indoors. The mean penetration factor was 0.41 (SD 0.11) for the nucleation mode (7-25 nm), 0.74 (SD 0.09) for the Aitken mode (25-100 nm), and 0.87 (SD 0.06) for the accumulation mode (100-600 nm). CONCLUSIONS: The ultrafine particles were bimodal with a nucleation mode (particle diameter <25 nm) and an Aitken mode (25 nm <particle diameter <100 nm). An accumulation mode was observed with a particle diameter larger than 100 nm. The patterns of fine-particulate air pollution inside an office can be largely estimated on the basis of the outdoor aerosol characterization and the mechanical ventilation system.

Air Pollutants↗