PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polymers”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Drug physical state and drug-polymer interaction on drug release from chitosan matrix films.

Four different grades of chitosan varying in molecular weight and degree of deacetylation were used to prepare chitosan films. Salicylic acid and theophylline were incorporated into cast chitosan films as model acidic and basic drugs, respectively. Crystalline characteristics, thermal behavior, drug-polymer interaction and drug release behaviors of the films were studied. The results of Fourier transform infrared and solid-state 13C NMR spectroscopy demonstrated the drug-polymer interaction between salicylic acid and chitosan, resulting in salicylate formation, whereas no drug-polymer interaction was observed in theophylline-loaded chitosan films. Most chitosan films loaded with either salicylic acid or theophylline exhibited a fast release pattern, whereas the high viscosity chitosan films incorporated with salicylic acid showed sustained release patterns in distilled water. The sustained release action of salicylic acid from the high viscosity chitosan films was due to the drug-polymer interaction. The mechanism of release was Fickian diffusion control with subsequent zero order release. It was suggested that the swelling property, dissolution characteristics of the polymer films, pK(a) of drugs and especially drug-polymer interaction were important factors governing drug release patterns from chitosan films.

Calorimetry, Differential Scanning↗

Polymer degradation and in vitro release of a model protein from poly(D,L-lactide-co-glycolide) nano- and microparticles.

The objective of the study was to investigate the effect of particle size of nano- and microparticles formulated from poly(D,L-lactide-co-glycolide) (50:50 PLGA) on polymer degradation and protein release. Since the surface area to volume ratio is inversely proportional to the particle size, it is hypothesized that the particle size would influence the polymer degradation as well as the release of the encapsulated protein. PLGA nano- and microparticles of approximate mean diameters of 0.1, 1 and 10 microm, containing bovine serum albumin as a model protein, were formulated using a multiple water-in-oil-in-water emulsion solvent evaporation technique. These particles were incubated at 37 degrees C in phosphate-buffered saline (pH 7.4, 154 mM) and the particles were characterized at various time points for molecular weight of polymer, surface-associated polyvinyl alcohol content (PVA), and the particle surface topology using scanning electron microscopy. The supernatants from the above study were analyzed for the released protein and PVA content. Polymer degradation was found to be biphasic in both nano- and microparticles, with an initial rapid degradation for 20-30 days followed by a slower degradation phase. The 0.1 microm diameter nanoparticles demonstrated relatively higher polymer degradation rate (P<0.05) during the initial phase as compared to the larger size microparticles (first order degradation rate constants of 0.028 day(-1), 0.011 day(-1) and 0.018 day(-1) for 0.1, 1 and 10 microm particles, respectively), however the degradation rates were almost similar (0.008 to 0.009 day(-1)) for all size particles during the later phase. All size particles maintained their structural integrity during the initial degradation phase; however, this was followed by pore formation, deformation and fusion of particles during the slow degradation phase. Protein release from 0.1 and 1 microm particles was greater than that from 10 microm size particles. In conclusion, the polymer degradation rates in vitro were not substantially different for different size particles despite a 10- and 100-fold greater surface area to volume ratio for 0.1 microm size nanoparticles as compared to 1 and 10 microm size microparticles, respectively. Relatively higher amounts of the surface-associated PVA found in the smaller-size nanoparticles (0.1 microm) as compared to the larger-size microparticles could explain some of the observed degradation results with different size particles.

Animals↗

Polymer water-soluble derivatives of polypeptide antibiotic, gramicidin-S based on reactive copolymers of N-(2-hydroxypropyl) methacrylamide.

Copolymers of N-(2-hydroxypropyl)methacrylamide with p-nitrophenyl esters of unsaturated phenoxyacetic acids and N-methacryloylglycylleucine and with acrylic acid were synthesized as polymer carriers for obtaining water-soluble polymer forms of an antibiotic gramicidin-S. The kinetics of the aminolysis of copolymers of N-(2-hydroxypropyl) methacrylamide (HPMA) which contain reactive p-nitrophenoxycarbonyl groups by gramicidin-S were investigated. It was established that aminolysis rate depends on the structure of the bridge group which binds p-nitrophenoxycarbonyl group to the main chain of the copolymer. On the basis of these copolymers of HPMA polymer amide and salt derivatives of gramicidin-S were obtained and their composition was determined. It was shown, that the antibacterial activity of these polymer derivatives of gramicidin-S depends on the bond type of the antibiotic with the polymer and attains a relatively high level for polymer salts of gramicidin-S.

Acrylates↗

Attachment of staphylococci to various synthetic polymers.

Attachment of staphylococci to different synthetic polymers used for medical purposes was studied in applying the bioluminescent technique. The number of attached bacterial cells was determined by measuring the light emission resulting from the reaction between firefly luciferase and ATP present in adhered staphylococcal cells. It was shown that staphylococci attach to synthetic polymers within a few minutes, although one hour incubation is required to reach a constant maximum value of attached cells. Ten different synthetic polymers and five Staphyloccocus epidermidis strains were investigated in our study. The relationship between surface properties of polymers and bacterial attachment was studied. Various physicochemical parameters of synthetic polymers and bacteria were determined (contact angle, surface tension). It was demonstrated that bacterial attachment decreases with decreasing contact angle and with increasing surface tension of synthetic materials. Modifications of surface charge and hydrophobicity of solid materials were also investigated. It could be proved that especially negatively charged and hydrophilic synthetic polymers show very decreased staphylococcal attachment.

Catheters, Indwelling↗

Polymer erosion in PLGA microparticles produced by phase separation method.

This article deals with polymer erosion in biodegradable microparticles produced using the phase separation method. Poly(lactic-co-glycolic acid) copolymers with different compositions and molecular weights were employed. The microparticles were stored in phosphate buffer for 6 months. The molecular weight of the polymers was determined by size exclusion chromatography, and the weight loss was monitored gravimetrically. No weight loss was measured in the first weeks, although the molecular weight decreased significantly already from the start. After a certain storage period which was found to be specific for the type of polymer, the weight of the microparticles decreased rapidly. The start of this weight loss occurred when the molecular weight of the polymer in the degrading microparticles reached a threshold of approximately 15,000. This critical molecular weight was found to be identical for all investigated polymers, i.e. it was independent of the initial molecular weight of the polymer and of the lactic-glycolic ratio.

Chromatography, Gel↗

Improved immune response from biodegradable polymer particles entrapping tetanus toxoid by use of different immunization protocol and adjuvants.

Poly lactide-co-glycolide (PLGA) and polylactide (PLA) particles entrapping immunoreactive tetanus toxoid (TT) were prepared using the solvent evaporation method. The effect of different formulation parameters such as polymer hydrophobicity, particle size and use of additional adjuvants on the generation of immune responses in experimental animals was evaluated. Immune responses from hydrophobic polymer particles were better than those from hydrophilic polymer. Immunization with physical mixtures of different size particles resulted in further improvement in anti-TT antibody titers in Wistar rats. Physical mixture of nano and microparticles resulted in early as well as high antibody titers in experimental animals. Immunization with polymer particles encapsulating stabilized TT elicited anti-TT antibody titers, which persisted for more than 5 months and were higher than those obtained with saline TT. However, antibody responses generated by single point immunization of either particles or physical mixture of particles were lower than the conventional two doses of alum-adsorbed TT. Immunization with nanoparticles along with alum resulted in very high and early immune response: high anti-TT antibody titers were detected as early as 15 days post-immunization. Use of a squalene emulsion along with the particles during immunization enhanced the level of anti-TT antibody titers considerably. Single point immunization with admixtures of PLA microparticles and alum resulted in antibody response very close to that achieved by two injections of alum-adsorbed TT; the antibody titers were more than 50 microg/ml over a period of 6 months. These results indicated that the judicious choice of polymer and particles size, protecting the immunoreactivity of the entrapped antigen and the appropriate design of immunization protocol along with suitable adjuvant can lead to the generation of long lasting immune response from single dose vaccine formulation using polymer particles.

Adjuvants, Immunologic↗

Critical properties of lactide-co-glycolide polymers for the use in microparticle preparation by the aerosol solvent extraction system.

The Aerosol Solvent Extraction System (ASES) process uses supercritical carbon dioxide for the production of microparticles. Since the critical temperature for this gas is at 304 K, polymers that are used in this process must fulfil certain requirements in crystallinity, and thermal behavior. This can be achieved by the use of blocked copolymers and thus the presence of semicrystalline microdomains in the polymers. However, changing the sequences of the comonomers dilactide and lactide often leads to polymers of low solubility due to long glycolide blocks. In this study, the critical properties of two blocked co-polymers were investigated, such as the blocked structure itself by (1)H-NMR and (13)C-NMR, the thermal behavior by differential scanning calorimetry (DSC), and the crystallinity by powder diffraction. The impact of these properties on microparticles formed by those polymers was also object of these studies. Additionally, two different model drugs, albumin and estriolm were embedded to investigate the impact of different polymer properties on drug content and release.

Aerosols↗

Physico-chemical characterization of interactions between erythromycin and various film polymers.

In this study the interactions between erythromycin and various polymers (Eudragit L100, shellac, polyvinyl acetate phthalate (PVAP), cellulose acetate phthalate (CAP), hydroxypropyl methylcellulose acetate phthalate (HPMCP), and hydroxypropyl methylcellulose (HPMC)) were investigated. The polymer films containing drugs were prepared and characterized by the use of infrared spectroscopy, powder X-ray diffraction analysis, thermal analysis, thin layer chromatography, and nuclear magnetic resonance (NMR) spectroscopy. Preliminary studies of pure drug powders recrystallized in various organic solvent systems suggested a mixture of amorphous and crystalline forms whereas those recrystallized in water and organic solvent-water mixture led to the dihydrate form. Erythromycin in drug-polymer mixtures exhibited molecular dispersions in all six polymers studied. The amine salt interaction between the carboxyl group of the acid polymers and N-atom of erythromycin was indicated by the NMR technique. The solid solution of erythromycin in all polymer films studied was physically stable under stress conditions (8 degrees C/3 days and 40 degrees C/3 days for six cycles).

Anti-Bacterial Agents↗

Preformulation studies and characterization of the physicochemical properties of amorphous polymers using artificial neural networks.

The utility of artificial neural networks (ANNs) as a preformulation tool to determine the physicochemical properties of amorphous polymers such as the hydration characteristics, glass transition temperatures and rheological properties was investigated. The neural network simulator, CAD/Chem, based on the delta back-propagation paradigm was used for this study. The ANNs software was trained with sets of experimental data consisting of different polymer blends with known water-uptake profiles, glass transition temperatures and viscosity values. A set of similar data, not initially exposed to the ANNs was used to validate the ability of the ANNs to recognize patterns. The results of this investigation indicate that the ANNs accurately predicted the water-uptake, glass transition temperatures and viscosities of different amorphous polymers and their physical blends with a low % error (0-8%) of prediction. The ANNs also showed good correlation between the water-uptake and changes in the glass transition temperatures of the polymers. This study demonstrated the potential of the ANNs as a preformulation tool to evaluate the characteristics of amorphous polymers. This is particularly relevant when designing sustained release formulations that require the use of a fast hydrating polymer matrix.

Alginates↗

Effect of pectinolytic enzymes on the theophylline release from pellets coated with water insoluble polymers containing pectin HM or calcium pectinate.

Theophylline pellets were coated with cellulosic (Aquacoat ECD 30, Surelease clear) or acrylic (Eudragit NE30D, RS30D) polymer aqueous dispersions, containing 10% (related to the insoluble polymer content) of pectin HM or calcium pectinate, using a Uni-Glatt fluidized-bed coating apparatus. When commercial pectinolytic enzymes were added to the dissolution media (0.05 M acetate - phosphate buffer, pH 6.0), the release of theophylline from the coated pellets was generally slower than that observed in the media without enzymes. The enzymatic slowing down of the drug release, depending on the type of the aqueous polymer dispersion used, is more important with mixed Eudragit NE/calcium pectinate coated pellets. The results obtained have been examined with regard to the validity of the approach based on the combination of pectins and the insoluble polymer aqueous dispersions intended for specific-delivery of drugs to the colon. The mechanism of the hydrophilic drug release from pellets coated with insoluble polymer aqueous dispersions containing an aqueous gel-forming polymer has been also discussed.

Absorption↗

The influence of polymer type, print donor and age on the quality of fingerprints developed on plastic substrates using vacuum metal deposition.

This study investigated fingerprint development on five different polymer substrates using vacuum metal deposition (VMD). The conditions required for optimum development are shown to depend on a number of factors. No one set of conditions will result in good development in all situations. Polymer type has been confirmed as a major factor in determining the types of development that will occur and the optimum VMD conditions required. For more consistently successful VMD development, polymer type should be determined before selecting conditions. While polymer type is a key factor in determining optimum development conditions, there may be variation of the optimum conditions within a polymer type, most likely due to the presence of additives in the plastic. The heaviness of a latent print, i.e. amount of residue that constitutes the print, also affects the VMD conditions required. The donor, manner of deposition, and age of a print affect the heaviness of the deposit. The heavier the print, the higher the gold count necessary for successful VMD development. The occurrence of 'empty prints' (i.e. zinc deposition on the general background but not on or between the print ridges) was found to be related to polymer type and print heaviness. Heavy prints on PVC and PET are the most likely to be 'empty' after VMD treatment. The development of empty prints may be due to the diffusion of print residue into the print valleys. Pre-treatment with cyanoacrylate fuming was also found to affect VMD development. In particular, it was shown that cyanoacrylate pre-treatment was beneficial for print development on PET and PVC. The results of this study were used to formulate guidelines for use as an aid by laboratories using VMD in casework.

Dermatoglyphics↗

Applicability of various amphiphilic polymers to the modification of protein release kinetics from biodegradable reservoir-type microspheres.

The effects of various amphiphilic polymers on the kinetics of protein release from reservoir-type microspheres, prepared by a solid-in-oil-in-water emulsion-solvent evaporation method, were investigated. Bovine serum albumin (BSA), as a model protein, was firstly micronized through co-lyophilization with amphiphilic polymers, such as poly (ethylene glycol) (PEG), polyvinylpyrrolidone (PVP), and pluronic F68. This process was based on the aqueous phase separation of protein and amphiphilic polymer induced by freezing-condensation. Mixing of poly(lactic-co-glycolic acid) (PLGA) and poly(lactic acid) (PLA) (at a ratio of 4:6) in a methylene chloride solution provided a'polymer-alloy' structure, where the preformed solid BSA microparticles were selectively distributed in the inner PLGA-rich phase. The reservoir-type microspheres obtained through this process showed high entrapment efficiencies (more than 85%) and reduced initial burst releases (less than 10%). Although PVP did not modify the BSA release profile, PEG and pluronic F68 enhanced the BSA release, with no increase of the initial burst effect, responding to their loading percentage: 3% loading of PEG or pluronic F68 resulted in typical zero-order release kinetics. The abilities of these amphiphilic polymers to modify the protein release profile could be predicted from their partitioning characteristics in the polymer-alloys and in the methylene chloride/water system.

Biodegradation, Environmental↗

Polymer complexes. XXXX. Supramolecular assembly on coordination models of mixed-valence-ligand poly[1-acrylamido-2-(2-pyridyl)ethane] complexes.

The build-up of polymer metallic supramolecules based on homopolymer (1-acrylamido-2-(2-pyridyl)ethane (AEPH)) and ruthenium, rhodium, palladium as well as platinum complexes has been pursued with great interest. The homopolymer shows three types of coordination behaviour. In the mixed valence paramagnetic trinuclear polymer complexes [(11)+(12)] in the paper and in mononuclear polymer complexes (1)-(5) it acts as a neutral bidentate ligand coordinating through the N-pyridine and NH-imino atoms, while in the mixed ligand diamagnetic poly-chelates, which are obtained from the reaction of AEPH with PdX2 and KPtCl4 in the presence of N-heterocyclic base consisting of polymer complexes (9)+(10), and in monouclear compounds (6)-(8), it behaves as a monobasic bidentate ligand coordinating through the same donor atoms. In mononuclear compounds (13)+(14) it acts as a monobasic and neutral bidentate ligand coordinating only through the same donor atoms. Monomeric distorted octahedral or trimeric chlorine-bridged, approximately octahedral structures are proposed for these polymer complexes. The poly-chelates are of 1:1, 1:2 and 3:2 (metal-homopolymer) stoichiometry and exhibit six coordination. The values of ligand field parameters were calculated. The homopolymer and their polymer complexes have been characterized physicochemically.

Chelating Agents↗

Gene delivery with in-situ crosslinking polymer networks generates long-term systemic protein expression.

Two polyethylene oxide-based delivery systems comprised of reacting PEG polymers were designed for the delivery of DNA expression vectors. The polymers are formulated with the DNA and injected into the muscle, wherein a crosslinked matrix forms in-situ. The matrix resembles a viscous solution (formulation A) or a gel (formulation B). The reacting PEG polymers do not interact with, but entrap the DNA. The formation of the matrix does not affect the supercoiling of the incorporated DNA. The polymers are biocompatible and biodegradable due to the presence of hydrolytically labile bonds in one of the components. Measurement of degradation in vivo suggests that a significant amount of the polymer disappears from the injected muscle by 28 days post injection. Administration to mice of SEAP plasmid DNA formulated with the PEG polymers results in SEAP expression. Expression levels are similar to those of unformulated DNA, but the duration of gene expression is significantly longer in immunocompetent animals receiving the formulated DNA. Significantly lower anti-SEAP IgG titers are elicited by network-formulated DNA relative to unformulated DNA, even though expression levels are comparable. The data suggests that the matrix extends duration of expression by reducing the anti-SEAP immune response so that these delivery systems may be useful for prolonged gene expression following a single intramuscular injection.

Alkaline Phosphatase↗

Effective capillary electrophoresis-based heteroduplex analysis through optimization of surface coating and polymer networks.

The efficacy of capillary electrophoresis for detecting DNA mutations via heteroduplex analysis (HDA) is dependent upon both the effective passivition of the capillary surface and the choice of the correct polymer network for sieving. Using HDA with laser-induced fluorescence detection of fluorescently labeled DNA fragments, an effective coating and optimal polymer matrix were sought. Optimized separation conditions were determined through the methodological evaluation of a number of different silanizing reagents, polymeric coatings, and polymer networks for resolving the PCR-amplified DNA fragments associated with five mutations (185delAG, 1294del40, 4446C > G, 5382insC, 5677insA) in the breast cancer susceptibility gene (BRCA1). For capillary coating, allyldimethylchlorosilane, 4-chlorobutyldimethylchlorosilane, (gamma-methacryloxypropyl)trimethoxysilane, chlorodimethyloctylsilane (OCT), and 7-octenyltrimethoxysilane were evaluated as silanizing reagents in combination with poly(vinylprrolidone) (PVP) and polyacrylamide (PA) as the polymeric coat. The HDA results were compared with those obtained using a commercial (FC) coated capillary. Of these, the OCT-PVP combination was found to be most effective. Using this modified capillary, HDA with polymer networks that included hydroxyethylcellulose (HEC), linear polyacrylamide, and PVP showed that a PVP-, PA-, or FC-coated capillary, in combination with HEC as the sieving polymer, could be used effectively to discriminate the mutations in less than 10 min. However, optimal performance was observed with the OCT-PVP-coated capillary and HEC as the polymer network.

DNA↗

Elastic effects of polymer coatings on surface acoustic waves.

Surface acoustic wave (SAW) devices are presently receiving careful scrutiny for applications in chemical sensing as well as in polymer characterization. Gas monitors based on SAW sensors have the potential for miniaturization and high sensitivity to a wide variety of substances. Polymer characterization is applicable to such diverse fields as protective coating design and decontamination of polymers. To better understand the physical mechanisms behind SAW response, the effects of the elastic properties in comparison to the mass loading of polymer coatings on SAW substrates were investigated. A theoretical basis for the effects of vapor-induced swelling or of thermal expansion was established. Compressive tension and its effect on SAW frequencies were found to be simple to describe, if there is no film slippage or polymer flow. The response of quartz substrate SAW crystals coated with polycarbonate and polyimide (glassy polymers) upon exposure to toluene and methanol was measured. Practical problems as to film uniformity, thickness measurement, and environmental control necessary in such measurements are described. Contrary to recent reports in the literature, no significant elastic tightening effect was observed with these vapor/polymer pairs.

Elasticity↗

Rational design of a polymer specific for microcystin-LR using a computational approach.

A computational approach for the design of a molecularly imprinted polymer (MIP) specific for Cyanobacterial toxin microcystin-LR is presented. By using molecular modeling software, a virtual library of functional monomers was designed and screened against the target toxin, employed as a template. The monomers giving the highest binding energy were selected and used in a simulated annealing (molecular dynamics) process to investigate their interaction with the template. The stoichiometric ratio observed from the simulated annealing study was used in MIP preparation for microcystin-LR. The monomers were copolymerized with a cross-linker in the presence of the template. A control (blank) polymer was prepared under the same conditions but in the absence of template. A competitive assay with microcystin-horseradish peroxidase conjugate was optimized and used to evaluate the affinity and cross-reactivity of the polymer. The performance of the artificial receptor was compared to the performance of monoclonal and polyclonal antibodies raised against the toxin. The results indicate that imprinted polymer has affinity and sensitivity comparable to those of polyclonal antibodies (the detection limit for microcystin-LR using the MIP-based assay was found to be 0.1 microg L-1), while superior chemical and thermal stabilities were obtained. Moreover, cross-reactivity to other toxin analogues was very low for the imprinted polymer, in contrast to the results achieved for antibodies. It is anticipated that the polymer designed could be used in assays, sensors, and solid-phase extraction.

Computer Simulation↗

Metal nanoparticle deposition for TOF-SIMS signal enhancement of polymers.

A novel technique for improved time-of-flight secondary ion mass spectra of polymer ions is presented. This technique is a simple preparatory method, which involves deposition of a submonolayer coverage of metal nanoparticles on the surface of a polymer sample enabling an overall increase in characteristic polymer ions. This procedure gives spectra with enhanced intensity, a larger number of characteristic polymer peaks, and peaks of higher mass. Both Au and Ag nanoparticles were employed to facilitate the ionization of the polymer characteristic secondary ions. Moreover, these experiments demonstrate that the nanoparticles allow localization of high-mass fragment ions during imaging experiments utilizing focused ion beams. In general, we show that the metal nanoparticle deposition method is effective for time-of-flight secondary ion mass spectrometry examination of polymers.

Gold↗