Rapid determination of the radiochemical purity of 99mTc-antimony trisulfide colloid prepared by standard and alternative heating methods.

UNLABELLED: The purpose of this study was to validate a rapid quality control method for the lymphoscintigraphic tracer 99mTc-antimony trisulfide colloid (99mTc-ATC). METHODS: ATC was labeled with 99mTc according to the manufacturer's instructions as well as by alternative heating conditions designed to provide a range of percentages of radiochemical purity (RCP): the tracer was prepared in a dry block heater with heating cavities of different sizes, the temperature of the heating block was varied from 70 degrees C to 115 degrees C, or the duration of heating was varied from 15 to 35 min. Anion-exchange minicolumns were trialled to separate any 99mTc-pertechnetate impurity from 99mTc-ATC with physiologic saline as the eluent. Quality control results were compared with the results from the manufacturer's recommended method, which uses an instant thin-layer chromatography (ITLC) strip with saline as the migrating solution. RESULTS: The quality control results obtained with a cartridge method in 2-3 min compared favorably with those obtained with the ITLC method with saline when the tracer was prepared by heating at 115 degrees C in a dry block heater for 35 min (RCPs, 99.4%+/-0.3% [mean+/-SD] and 99.2%+/-0.3%, respectively; n=25). The cartridge and ITLC quality control results also were in excellent agreement (correlation coefficient, 0.99) over a range of RCPs (80%-100%). An alternative anion-exchange cartridge that was tested in this study was not suitable for assaying the RCP of 99mTc-ATC because of the complete retention of 99mTc-pertechnetate on the sorbent. CONCLUSION: Compared with the established ITLC method, the cartridge quality control method tested in this study is rapid and provides a reliable assessment of the RCP of 99mTc-ATC. For the preparation of 99mTc-ATC, a dry block heater can be successfully substituted for a boiling water bath and is recommended for heating at high altitudes.

Antimony↗

In-vitro investigations evaluating the detection spectrum of cervical lymph nodes via handheld gamma probe.

BACKGROUND: Currently the significance of the sentinel node (SN) biopsy also for head and neck cancer is discussed intensively. Based on the complex anatomic structures of this region with a low distance between primary and sentinel node as well as approximately 300 lymph nodes an intensive discussion of the methodical basis of sentinel node detection seems to be essential. Thus it was the aim of the present study to examine the detection spectrum of a gamma probe for identification of cervical lymph nodes using an in vitro model to describe and objectify the particularities of measurement existing in the head and neck region. MATERIAL/METHODS: In an in vitro model the detection spectrum of a gamma probe is examined in 29 different series of measurements (variation of the specimen filled with 99m pertechnetat regarding activity, position, collimator distance, tissue sheath). RESULTS: The presented in vitro model reflects the clinical problem of narrow intranodal activity of neighbouring lymph nodes and reveals a direct relation between the number of radiation sources and their isolated evidence. Using muscle tissue with a thickness of 0.4 cm, two two-rowed radiation sources, the more powerful is placed 1.5 cm behind the other specimen, with a lateral difference of 3 cm, can be resolved only with a maximal detector distance of 1 cm. Not the difference of the tissue but the thickness of the tissue is decisive for detection. CONCLUSION: Especially for pharyngeal and laryngeal lymph nodes a transcutaneous measurement reflecting the exact localisation of hot nodes in the area of the deep jugular lymph nodes is not possible with increasing tissue thickness. The described results require a critical discussion of the different detection techniques varying among the different working groups of this field.

Gamma Rays↗

[Sentinel nodes in patients with breast cancer].

The aim of this paper is to debate, on the basis of medical literature review, the importance of detection the sentinel nodes in surgery of breast cancer. The beginning of the paper emphasized the problems of the sentinel nodes definition, and then we discuss the dates related to the history and the importance of the sentinel nodes knowledge that consist in the avoidance of axillary lymph nodes dissection in patients with breast cancer N-. Afterwards, we present the indications for detecting the sentinel nodes and the criterion to exclude from the detection of the sentinel nodes. As a part of the results of surgery sentinel nodes, we present dates about the techniques of detection the sentinel nodes, the place of injection of the radiopharmaceuticals, the size of the radiocolloid. Finally, we come up in the conclusion that the identification of the sentinel nodes is useful and possible for majority of the patients with breast cancer T1 or T2N0M0.

Axilla↗

Sequential 99mTc-hydrazinonicotinamide-annexin V imaging for predicting response to chemotherapy.

UNLABELLED: This study was undertaken to evaluate changes in relative (99m)Tc-hydrazinonicotinamide (HYNIC)-annexin V tumor uptake over time in patients undergoing chemotherapeutic treatment at baseline and at 5-7 h and 40-44 h after treatment initiation. Imaging results are related to clinical outcomes, as assessed with response evaluation criteria in solid tumors (RECIST). METHODS: We prospectively included 20 patients (11 men and 9 women; mean age, 59.8 y; range, 22-75 y) scheduled for chemotherapy (n = 19) or bisphosphonate treatment (n = 1). Curable disease was present in 5 patients. The other patients had metastatic disease and were treated in a palliative setting. Three of the 20 enrolled patients were excluded from analysis: 1 patient ultimately refused the proposed chemotherapy treatment; because of difficulties with the labeling procedure, 1 patient did not receive a pretreatment scan; and 1 patient presented with an allergic reaction (rash and nausea) to the (99m)Tc-HYNIC-annexin V formulation. The remaining 17 patients underwent 3 scintigraphic scans with (99m)Tc-HYNIC-annexin V: before treatment and 5-7 h and 40-44 h after treatment initiation. The tumor response was evaluated with RECIST and related to observed changes in the ratios of tumor activity to background activity for the largest known lesion; values exceeding 25% the baseline value on either the 5- to 7-h scan or the 40- to 44-h scan were considered significant. RESULTS: With the proposed sequential imaging protocol and a 25% change threshold, responders to treatment could be separated from nonresponders with a 94% accuracy (16/17 patients). CONCLUSION: Sequential (99m)Tc-HYNIC-annexin V imaging may allow for assessment of the response to chemotherapy within 3 d after treatment initiation.

Adult↗

[Changes in the wall motion of left ventricle in dipyridamole-induced ischemic cardiopathy studied by nuclear magnetic resonance. A comparison with myocardial scintigraphy with 99mTc MIBI].

To investigate whether magnetic resonance imaging (NMR) can detect alterations in LV contractility during myocardial ischemia, ten patients aged 32-72 with coronary artery disease underwent ECG gated NMR performed at 0.5 Tesla after intravenous infusion of high dose dipyridamole (DP) (0.7 mg/Kg) over 5 minutes. LV contraction in planes similar to echo short axis projection was imaged under condition, 3' and 15-20' after infusion of DP by fast multiphasic imaging (FMI), multiple angulated cine-NMR sequence with a temporal resolution of 50 m/sec. Entity and size of perfusion defects after DP were determined by Tc 99m MIBI myocardial scintigraphy. In all patients changes in LV contractility appeared at NMR in the same site of perfusion impairments revealed with MIBI. In 8 patients the alterations lasted even more than 20' after the first NMR scan. NMR provides the opportunity of performing long-lasting assessment of ventricular wall contractility and enables to exactly localize the site and extension of kinetic changes as well as their time of onset and time duration.

Contrast Media↗

[Results of myocardial scintigraphy in patients with left bundle-branch block using Tl-201 and Tc-99m-MIBI].

Tl-201 myocardial scintigrams in patients with left bundle-branch block (LBBB) are frequently non-diagnostic with respect to presence or absence of coronary artery disease (CAD). The new myocardial perfusion tracer Tc-99m-MIBI requires a different protocol due to its insignificant redistribution. Therefore, scintigraphic patterns in LBBB cannot be deduced from experiences with Tl-201. In a total of 132 patients with LBBB, 81 studies were carried out with Tl-201, another 81 studies with Tc-99m-MIBI. In 30 patients both radiopharmaceuticals were employed. 72% of the Tl-201 scintigraphies in constant LBBB resulted in a reversible septal deficit and 9% in a constant septal deficit. In contrast, 70% of the Tc-99m-MIBI scintigraphies resulted in a constant septal deficit and only 19% in a reversible septal deficit. Similar "discrepancies" were found in LBBB patients in whom CAD has been angiographically excluded (N = 17). All patients, however, with LAD or RCA stenoses and constant LBBB showed reversible septal deficits with either tracer, Tl-201 (N = 12) or Tc-99m-MIBI (N = 10). It is concluded: 1) that the majority of patients with LBBB has reduced septal perfusion, 2) that this reduction is typically stress-independent in absence of CAD, and 3) that this stress-independent perfusion deficit is, in general, only differentiated from stress-induced ischemia (in case of CAD) with using the Tc-99m-MIBI protocol.

Adult↗

99Tcm-exametazime-labelled leucocytes: effect of volume and concentration of exametazime on labelling efficiency, and clinical protocol for high efficiency multi-dose radiolabelling.

We have investigated the effect of volume and concentration of exametazime on the labelling efficiency of 99Tcm-exametazime-labelled leucocytes. The first study examined the effect of varying the volume of exametazine solution whilst the concentration remained constant. A vial of Ceretec (Amersham Ltd plc) was reconstituted with sodium chloride injection BP. Aliquots of 0.25-2.0 ml were removed, added to sodium pertechnetate injection BP and incubated with 2 x 10(7)-5 x 10(7) leucocytes from 25 ml blood. The labelling efficiency decreased from 65 +/- 10% S.D. (0.25 ml) to 45 +/- 8% (2.0 ml) (n = 4). In a second study different concentrations of exametazime solution were used whilst the volume remained constant. A vial of Ceretec was reconstituted with sodium chloride injection BP. Aliquots of 25-200 micrograms were removed, made up to a fixed volume of 0.6 ml, added to pertechnetate and incubated with the plug of leucocytes as before. The labelling efficiency decreased as the concentration of ligand decreased. Thus for 200 micrograms/0.6 ml the labelling efficiency was 64 +/- 5% and for 25 micrograms/0.6 ml the labelling efficiency was 43 +/- 18% (n = 4). Clinical studies were performed using 50 ml blood from patients with a wide range of inflammatory disorders including inflammatory bowel disease, abdominal abscess and vasculitis. The concentration of ligand used was 83 micrograms/0.25 ml. The labelling efficiency was found to be 82 +/- 7% (n = 36).

Butanones↗

[New techniques in nuclear cardiology: SPECT, PET and antimyosin].

Nuclear Cardiology offers non-invasive techniques of high reproducibility for cardiovascular assessment. These techniques have advanced enormously in the latest years. The advances in areas such as general technology and computer systems, medicine, immunology and research, allow us to obtain and interpret cardiac information with immediate or potential clinical applications unavailable few years ago. This paper describes 3 of these new techniques in nuclear cardiology: Single Photon Computed Tomography (SPECT); Positron Emission Tomography (PET) and; the use of an Antimyosin monoclonal antibody.

Antibodies, Monoclonal↗

[Evaluation of the results of the treatment of pseudarthroses of the forearm bones based on the analysis of the data of radionuclide studies].

The work is based on the analysis of the results of radionuclide examination and treatment of 14 patients with ununited tractures and pseudoarthroses of the forearm bones. Treatment was accomplished by means of external fixation apparatuses which in comparison with intramedullary and epiosseous osteosynthesis provide a better stability of the site of bone injury and create ortimal biomechanical conditions for consolidation of ununited fractures and pseudoarthroses of the forearm bones. Radionuclide examination was conducted before the treatment to determine the initial activity of reparative regeneration in the zone of the pseudoarthrosis and the adjacent healthy regions, 2-3 weeks after perosseous osteosynthesis when the bone fragments were reduced and the compression or distraction regimen was established, and before removal of the apparatus when consolidation of the pseudoarthrosis was demonstrated radiologically. This made it possible to control the activity of reparative regeneration during treatment and to introduce corrections, if necessary. The radionuclide method is preferable to the radiological method in the intermediate stages of treatment not only because of the lesser exposure of the patient to radiation but because of the higner informativeness.

Adolescent↗

Repeated 99mTc-Sestamibi studies for the evaluation of salvaged myocardium and of its relationship with postinfarction ischemia.

Pre- and post-treatment myocardial scans with 99mTc-Sestamibi demonstrated effective reperfusion after thrombolysis in a patient with acute myocardial infarction. Late follow-up images showed at rest a further noteworthy reduction of the uptake defect and that during exercise a large part of the salvaged territory became ischemic. This report demonstrates that a remarkable amount of myocardium in the posttreatment images was hibernated; furthermore, it was possible to visualize directly that the salvaged territory is the actual site of exercise induced postinfarction ischemia.

Heart↗

Three-dimensional motion and perfusion quantification in gated single-photon emission computed tomograms.

Methods for quantification and display of left ventricular (LV) functional parameters from gated single-photon emission computed tomographs are described. Using previously documented surface detection methods, we developed techniques for calculating global variables, such as volumes and areas, as well as local variables such as segmental motion and local perfusion from gated tomographic radionuclide ventriculograms (TRVG) and gated perfusion tomograms (sestamibi). We have developed three-dimensional displays to allow realistic visualizations of the results. The motion results have been validated using correlative magnetic resonance imaging (MRI) studies; motion calculated from user-traced MR images of the heart was compared to motion calculated from automatically detected surfaces in TRVG and sestamibi. The average motion error was calculated to be 0.67 mm in TRVG and -0.21 mm in sestamibi. Errors were largest in basal LV regions; we explain this phenomenon using simulations. Finally, we present additional examples of the analysis using studies obtained from normal volunteers and from subjects whose coronary artery anatomies were known.

Coronary Disease↗

[Comparison of 99mTc-hexakis 2-methoxy-2-isobutyl isonitrile and 201Tl SPECT imaging for evaluation of coronary artery disease].

To evaluate clinical value of 99mTc-hexakis 2-methoxy-2-isobutyl isonitrile (MIBI) imaging for assessing coronary artery disease (CAD), 99mTc-MIBI SPECT imaging at post-exercise and at rest was compared with 201Tl SPECT imaging at post-exercise and 3 hours redistribution in 27 patients suspected with CAD. The sensitivities for detecting CAD patients were 94% (17/18) by both studies. The specificities were 71% (5/7) by 99mTc-MIBI and 57% (4/7) by 201Tl (p = NS). The sensitivities for detecting stenosed coronary arteries (greater than or equal to 75% stenosis) were also similar between 99mTc-MIBI (78%) and 201Tl (74%) (p = NS). The similar specificity values were obtained by 99mTc-MIBI (84%) and by 201Tl (82%) (p = NS). The patterns of abnormality (normal, ischemia and scar) were similar between 99mTc-MIBI and 201Tl images in 22 of the 25 cases (88%) and 117 of the 125 segments (94%). However, these patterns were occasionally different particularly in patients who received PTCA or CABG. Thus, 99mTc-MIBI SPECT imaging seems to be as accurate as 201Tl SPECT imaging for the detecting and evaluating CAD.

Adult↗

[Clinical evaluation of 99mTc-hexakis 2-methoxy isobutyl isonitrile (MIBI): multicenter phase III clinical trial].

Multicenter Phase III clinical trial on a new myocardial imaging agent, 99mTc-hexakis 2-methoxy isobutyl isonitrile (99mTc-MIBI), was carried out in 464 patients with various cardiac disorders. Both planar and tomographic images provided high-quality regional myocardial perfusion images which correlated well with 201TlCl images. The positive ratios of myocardial infarction and angina pectoris by the agent were as high as that of 201TlCl. In addition, ventricular function and wall motion could be assessed with first-pass and ECG gated studies. There was no serious adverse reaction which were attributed to 99mTc-MIBI in any of patients studied. A transient metallic taste was observed immediately after the injection in approximately 64% of the patients. Based on its safety and efficacy, the clinical usefulness of 99mTc-MIBI was observed in 562 (93.1%) of 604 injections. In conclusion, 99mTc-MIBI was useful as a imaging agent of myocardial blood flow.

Adolescent↗