At least 1,063 records · Page 59Linked to original sources

Lower limb vein enlargement and spontaneous blood flow echogenicity are normal sonographic findings during pregnancy.

PURPOSE: We studied pregnancy-induced changes in lower limb venous function. METHODS: We used plethysmography and sonography to assess the changes in venous wall distensibility, saphenous vein diameters, and spontaneous blood flow echogenicity in the common femoral veins in 190 consecutive women during and after uncomplicated pregnancies (total of 409 examinations). RESULTS: The percentage of women with clinical symptoms and signs of venous insufficiency increased significantly during pregnancy. The mean diameters of the great and small saphenous veins also increased significantly, while occlusive venous plethysmography showed a decrease in parameters indicating vein distensibility. Spontaneous blood flow echogenicity in the common femoral veins was clearly visible or marked in 6% of cases during the first trimester of pregnancy, 63% during the second trimester, and 96% during the third trimester, versus 6% after delivery (p < 0.0001). The mean hematocrit decreased and the mean fibrinogen concentration increased during pregnancy. CONCLUSIONS: The increase in lower limb venous pressure seen during pregnancy leads to venous overdistention and worsens blood stasis. Decreased venous flow velocity and rheological alterations result in increased red cell aggregation, giving rise to spontaneous blood flow echogenicity. Spontaneous blood flow echogenicity is therefore a normal finding during pregnancy and should not be mistaken for venous thrombosis.

Adult↗

Thrombin-antithrombin complex and the prothrombin fragment in arterial and venous blood of patients with peripheral arterial disease.

BACKGROUND: Thrombin generation has recently been recognized as an important factor in the development of arterial occlusive disease in all vascular provinces. Several reports concerning markers of thrombin generation have been published with however, conflicting results. It has been demonstrated in vitro that accelerated blood flow velocity causes increased thrombin generation via higher shear rates. In recent articles TAT and F1 + F2 concentrations are reported significantly higher in arterial than in venous blood. A correlation with the severity of atherosclerosis or specially with the stage of PAD was expected. In the present investigation we additionally collected blood from the femoral vein. PATIENTS AND METHODS: In 11 patients with Fontaine stages IIb to IV and two healthy subjects TAT and F1 + F2 concentrations were determined in blood samples from the femoral artery, the femoral vein (diseased leg) and cubital vein. In all cases and at all puncture sites exactly the same atraumatic technique of venipuncture was used. RESULTS: The concentrations of TAT and F1 + F2 were significantly elevated in patients with PAD. There was no significant difference between the concentrations of TAT and F1 + F2 in arterial (femoral artery) and venous (femoral vein and cubital vein) blood. CONCLUSION: The results from previous investigations have been confirmed only partially. Differences in the puncture techniques to collect arterial or venous blood result in an increased scattering of the data and a systematic error.

Adult↗

[Leiomyosarcoma in the area of the pelvic vein].

A 37-year-old patient presented with relapsing edema of the left leg lasting for 3 months. The radiological investigations indicated a thrombotic occlusion of the pelvic veins. Surgery revealed a neoplastic growth within the common femoral vein. Histology corresponded to a leiomyosarcoma of the venous wall with intraluminal growth and no indication for penetration of the wall and invasion of the surrounding tissue. In a second operation the tumor-bearing parts of the profound and superficial femoral vein and the external iliac vein were removed. A postoperative infection with involvement of the superficial femoral artery necessitated resection of the artery and replacement by a bypass. Three months after the intervention the patients fares well. The swelling tendency of the left leg is minimal. A local recurrence of the tumor could not be detected so far. Chemotherapy was refused by the patient.

Adult↗

Thrombolytic and pharmacokinetic properties of chimeric tissue-type and urokinase-type plasminogen activators.

BACKGROUND: Chimeric molecules comprising the A-chain of tissue-type plasminogen activator (t-PA) and the catalytic domain of urokinase-type plasminogen activator (u-PA) have intact enzymatic characteristics of u-PA, partial fibrin-binding properties of t-PA, and thrombolytic properties in animal models comparable with but not superior to those of single-chain u-PA (scu-PA). Deletion of the finger and growth factor domains (t-PA-delta FE/scu-PA-e) in such chimeras further reduces their affinity for fibrin. METHODS AND RESULTS: A detailed investigation of the thrombolytic potency and the pharmacokinetics of t-PA and u-PA chimeras was performed in quantitative animal models for thrombolysis. In hamsters with pulmonary embolism, in rabbits with jugular vein thrombosis, and in baboons with femoral vein thrombosis, the thrombolytic potency (percent lysis per milligram of compound administered per kilogram of body weight) of t-PA-delta FE/scu-PA-e was significantly higher than that of recombinant scu-PA (rscu-PA, Saruplase) as shown by a maximal rate of 720 +/- 170% versus 45 +/- 5% lysis per milligram of compound per kilogram of body weight (mean +/- SEM, p less than 0.01) in hamsters, 210 +/- 18% versus 49 +/- 3% lysis per milligram of compound per kilogram of body weight (mean +/- SEM, p less than 0.01) in rabbits, and 310 +/- 73% versus 90 +/- 0.3% lysis per milligram of compound per kilogram of body weight (p less than 0.01) in baboons. However, the specific thrombolytic activity (percent lysis per microgram per milliliter steady-state plasma antigen level) of t-PA-delta FE/scu-PA-e was not significantly different from that of rscu-PA in hamsters (210 +/- 57% versus 160 +/- 27% lysis per microgram per milliliter antigen level) and was lower than that of rscu-PA in rabbits (37 +/- 4% versus 130 +/- 5% lysis per microgram per milliliter antigen level; p less than 0.01). In dogs with a combined femoral vein blood clot and a platelet-rich femoral arterial eversion graft thrombosis, 0.25 mg/kg body wt bolus injections of t-PA-delta FE/scu-PA-e produced significantly more venous clot lysis (90 +/- 5%, n = 10) than 0.25 mg/kg rscu-PA (26 +/- 3%, n = 10) (p less than 0.001) and, at the arterial side, more frequent (10 of 10 dogs versus three of 10 dogs) and more persistent (six of 10 dogs versus none of 10 dogs) recanalization (p = 0.002). After bolus injection in hamsters, rabbits, or baboons, t-PA-delta FE/scu-PA-e had a fourfold to sixfold longer initial half-life than rscu-PA and a slower plasma clearance of sixfold in hamsters, 10-fold in rabbits, and more than 10-fold in baboons. CONCLUSIONS: These results indicate that t-PA-delta FE/scu-PA-e has a markedly enhanced thrombolytic potency toward venous and arterial thrombi caused by a delayed in vivo clearance with relatively maintained specific thrombolytic activity. These properties suggest that the chimera may be clinically useful for thrombolytic therapy by bolus administration in patients with thromboembolic disease.

Animals↗

New experimental flap model in the rat: free flow-through epigastric flap.

This study describes a free flow-through flap model in the rat for use in the evaluation of the physiologic and hemodynamic characteristics of this type of flap in clinical practice. The rat is a preferred animal model because it is inexpensive, readily available, and reliable. There is no free flow-through flap model available for laboratory animals, although this model gained popularity in clinical use recently. Twenty Wistar rats weighing 200-250 g were used in our experiment. In 5 rats, the vascular anatomy of the groin and proximal thigh region was determined by anatomic dissection. The experimental design consisted of two groups. In the experimental group (N = 5), a flow-through epigastric skin flap was harvested based on the femoral artery, preparing both its proximal and distal stumps. The flap was transferred to the contralateral groin, and end-to-end vascular anastomosis was performed between a proximal and distal stump of the femoral arteries of the flap and recipient site. The proximal stump of the femoral vein of the flap was anastomosed to the femoral vein of the recipient site. The control group was divided into two subgroups. In all control group rats (N = 10), the flap was harvested in the same manner, and transferred to the contralateral groin, but standard free-flap procedure with one artery and one vein anastomosis was performed in 5 rats (conventional free-flap subgroup), and anastomosis was not performed between the flap and the recipient site in the remaining 5 rats (graft subgroup). Survival of the flap was evaluated on postoperative day 7 by direct observation, and microangiography was performed to delineate the vascularity of the flow-through flap. The results showed that all flaps survived in the experimental group and the conventional free-flap subgroup of the control group, whereas in the graft subgroup, all flaps underwent total necrosis. The authors conclude that the flow-through epigastric flap for the rat is a simple and reliable model for future physiologic and pharmacologic studies.

Anastomosis, Surgical↗

Total hip replacement and deep vein thrombosis. A venographic and necropsy study.

Bilateral venography was performed between 12 and 15 days after total hip replacement in 745 consecutive patients, all of whom had heparin prophylaxis. Of these, 81 patients (10.8%) showed evidence of recent deep vein thrombosis: 23 (3%) distal, 44 (5.9%) isolated proximal, five (0.7%) both proximal and distal, and nine (1.2%) extensive thrombosis from calf to thigh. Compared with previous reports heparin appeared to have reduced the number of distal and contralateral thromboses, but was far less effective in reducing proximal femoral thrombosis. In a cadaver study, the femoral veins were inspected during simulated total hip replacement by either an anterior or a posterior approach. In every case the femoral vein became kinked or folded in the thigh position imposed during the preparation of the femur. Local damage appears to be an important factor in proximal thrombosis; care at operation could help to minimise trauma to the femoral veins and reduce the number of such cases.

Femoral Artery↗

Physiologic variations in lower extremity venous valvular function.

We conducted this study to investigate the physiologic variations in venous valvular function and calf muscle pump function that occur in normal limbs after prolonged stationary standing. Twenty-two limbs from 11 healthy volunteers were studied after a brief period of activity and after 4 to 6 hours of stationary standing. Vein diameter, peak reflux flow velocity (PRFV), and valve closure time (VCT) were measured with duplex scanning in the standing position in the common femoral vein (CFV), superficial femoral vein (SFV), popliteal vein (POP), proximal greater saphenous vein (GSV), and greater saphenous vein at the knee (kGSV). Pneumatic rapid inflation-deflation cuffs were used to elicit reflux. Vein cross-sectional area (VA) and peak reflux volume (PRVol) were calculated. Venous volume (VV), venous filling index (VFI), ejection fraction (EF), residual volume fraction (RVF), and outflow fraction (OF) were measured with air plethysmography in all limbs. After stationary standing, there was no significant change or trend toward an increase in diameter or VA in any of the deep veins and there was no change in the PRFV or VCT. In the proximal GSV there was a significant increase in diameter (p = 0.0001) and VCT (p = 0.048) without a change in PRFV. No significant changes were noted in the kGSV. In the GSV the PRFV was significantly lower (p < 0.05) and the VCT significantly shorter (p < 0.05) compared with the SFV and POP but values were no different from those in the CFV. The PRFV was significantly higher in the SFV (p < 0.0001) and the POP (p < 0.002) compared with that in the CFV.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

The role of methylmethacrylate monomer in the formation and haemodynamic outcome of pulmonary fat emboli.

We examined the roles of methylmethacrylate (MMA) monomer and cementing technique in the formation, and haemodynamic outcome, of pulmonary fat emboli. The preparation of the femoral canal and the cementing technique were studied in four groups of adult dogs as follows: control (no preparation); lavage; cement pressurisation; and cement pressurisation after lavage. We measured the intramedullary pressure, pulmonary artery pressure (PAP), pulmonary capillary wedge pressure and bilateral femoral vein levels of triglyceride, cholesterol and MMA monomer at rest and after reaming, lavage, and cementing. Femoral vein triglyceride and cholesterol levels did not vary significantly from resting levels despite significant elevations in intramedullary pressure with reaming, lavage and cementing (p = 0.001). PAP was seen to rise significantly with reaming (p = 0.0038), lavage (p = 0.0031), cementing (p = 0.0024) and cementing after lavage (p = 0.0028) while the pulmonary capillary wedge pressure remained unchanged. MMA monomer was detected in femoral vein samples when cement pressurisation was used. Intramedullary lavage before cementing had no significant effect on the MMA level. Haemodynamic evidence of pulmonary embolism was noted with reaming and intramedullary canal preparation, irrespective of the presence of MMA monomer. We found no relationship between MMA monomer level and intramedullary pressure, PAP or pulmonary capillary wedge pressure. Our findings suggest that the presence of MMA monomer in femoral venous blood has no effect on the formation of fat emboli or their pulmonary haemodynamic outcome during cemented hip arthroplasty.

Animals↗

Pre- vs postoperative pharmacologic inhibition of platelets: effect on intimal hyperplasia in canine autogenous vein grafts.

Several clinical studies have shown that pharmacologic inhibition of platelets can increase the patency of vascular grafts, but only if platelet-inhibition is initiated before surgery. This study was performed to compare the efficacy of pre- vs postoperative platelet-inhibition on the development of intimal hyperplasia in canine autogenous vein grafts. Reversed femoral veins were used to bypass the ligated femoral arteries in 15 dogs. End-to-side anastomoses were constructed. Eleven dogs were treated with aspirin (325 mg QD) and dipyridamole (25 mg BID). In six dogs treatment was begun 48 hours preoperatively and continued for 3 months. In five other dogs treatment was begun 48 hours after surgery and was continued for 3 months. In 4 control dogs no antiplatelet treatment was given. Excision of the vein grafts 3 months after surgery disclosed reduced intimal hyperplasia (p < 0.05) in the grafts excised from all of the treated animals as compared with those obtained from the control animals. However, there was no difference in intimal hyperplasia observed in the dogs treated both pre- and postoperatively (11 grafts) as compared with those treated only postoperatively (9 grafts). These data demonstrate that it is not necessary to begin antiplatelet therapy preoperatively in order to inhibit intimal hyperplasia. They also suggest that preoperative antiplatelet therapy may improve early graft patency by directly preventing thrombosis, not by inhibiting the development of intimal hyperplasia.

Analysis of Variance↗

Increased spillover of norepinephrine to the portal vein during CO-pneumoperitoneum in pigs.

BACKGROUND: Elevated intra abdominal pressure (IAP) during CO2-insufflation has been associated with increased catecholamine concentrations in plasma. We have previously indicated that this may be due to a regional increased spillover from the abdominal region. In this experimental study we investigated catecholamine spillover from the drainage area of the portal vein during CO2-pneumoperitoneum. METHODS: Eight pigs under general anesthesia were investigated before and after CO2-pneumoperitoneum with an IAP of 15 mmHg. Regional spillover of catecholamines was determined by measuring plasma catecholamine concentrations and flow simultaneously. Plasma concentrations of catecholamines were measured from the portal and femoral veins, the pulmonary and carotid arteries. Flow data were collected with laser-Doppler transit time flow probes around the portal and femoral veins. Cardiac output was measured by the thermo-dilution technique. Estimated spillover was calculated by the veno-arterial difference multiplied by flow. RESULTS: We found a significant increase in estimated spillover of norepinephrine from the drainage area of the portal vein from 10 (-1.2, 78) ng x min(-1) to 27 (1.8, 475) ng x min(-1)[median (range)] (P = 0.05), but no change in estimated spillover of norepinephrine from the drainage area of the femoral vein. Plasma concentrations of norepinephrine increased in central venous and arterial blood. There was no significant change in epinephrine concentrations in arterial blood. CONCLUSION: Estimated norepinephrine spillover from the drainage area of the portal vein increased during CO2-pneumoperitoneum in pigs. This may indicate that the increased norepinephrine concentrations found in arterial plasma reflects a local activation of sympathetic nerves in the region of the portal drainage area.

Animals↗

Effect of blood access on the platelets of azotemic patients initiating dialysis therapy.

The effect of blood access on platelets and clotting factors was investigated in 46 azotemic patients. Arteriovenous fistula was used in 10 patients (AVF group), and polyurethane double-lumen catheters were inserted through the subclavian vein in 6 patients (PUS group) or through the femoral vein in 15 patients (PUF group). Indwelling urokinase-immobilized single-lumen catheters and double-lumen catheters were placed in the femoral vein of 5 patients (UKS group) and 10 patients (UKD group), respectively. Blood cell counts, beta-thromboglobulin (beta-TG), platelet factor 4 (PF4), prothrombin time, and activated partial thromboplastin time were measured before insertion while catheters were indwelling and after catheters were pulled out. Although the platelet count decreased to 83% of the initial value during indwelling in the PUF group and 89% in the PUS group, it did not decrease in the AVF, UKS, and UKD groups. There were no differences between the PUF and PUS groups nor between the UKS and UKD groups. Plasma beta-TG increased in the PUF and UKD groups with indwelling catheters but did not change with the AVF. From these results, we conclude that the AVF did not activate platelets, the urokinase-immobilized catheter activated platelets, and the polyurethane catheter activated and decreased platelets. This might be due to the different surface properties of each blood access. Thus, the urokinase-immobilized catheter seems to be more favorable than the polyurethane catheter for emergency blood access.

Arteriovenous Shunt, Surgical↗

Generalized changes in venous distensibility in postthrombotic patients.

INTRODUCTION: In situ biomechanical properties of peripheral large veins were compared between asymptomatic young patients who had previously unilateral femoro-popliteal deep venous thrombosis (DVT) and age-matched, healthy controls; the aim of this study was to assess local or generalized alterations of venous wall biomechanics in postthrombotic patients. PATIENTS AND METHODS: Inner diameters of both common femoral veins, right axillary vein, and right internal jugular veins were measured in two directions by ultrasonography. Venous pressure was altered by posture changes (standing and lying) and by application of graded and controlled Valsalva. Ten postthrombotic young patients without any symptoms and 11 age-matched control subjects were included. RESULTS: In postthrombotic patients, both the affected and unaffected common femoral vein diameters and capacities were larger at low transmural pressures than those for the control group, but they demonstrated significantly less distensibility when higher pressures were applied. Similarly, in the internal jugular vein, capacity without Valsalva was significantly higher in postthrombotic patients and distensibility was reduced (statistically significant in the erect position). Pressure-induced changes in axillary vein diameter were negligible. CONCLUSIONS: In situ diameter and capacity changes, and in situ distensibility of the femoral veins on both sides (i.e., the side of previous thrombosis as well as the disease-free side) and of the jugular veins are reduced in the young DVT patients compared to veins of the age-matched, healthy controls. The pathophysiological mechanism of generalized venous wall changes in these young DVT patients remains unknown.

Adolescent↗

[Doppler ultrasound diagnosis of lower extremity deep vein insufficiency: Valsalva maneuver or pneumatic cuff?].

PURPOSE: To compare the efficacy of Valsalva maneuver and pneumatic compression techniques in detecting lower extremity deep venous and saphenofemoral insufficiency. MATERIALS AND METHODS: Eighty-one extremities evaluated in 43 patients who had undergone Doppler ultrasound examination of the lower extremity venous system were included in the study. Valsalva maneuver and pneumatic cuff techniques were used to elicit reflux in the standing position. Reflux was investigated with spectral Doppler in the superficial femoral vein, popliteal vein, the proximal segment of the great saphenous vein close to its junction with the femoral vein and in its caudal segment at the medial aspect of the knee. The same measurements were repeated after rapid deflation of the pneumatic cuff, which was applied to the calf and was initially inflated to 200 mmHg. Retrograde flow exceeding 1000 msec was regarded as insufficiency. The results of the two techniques at each venous segment were compared with the McNemar test. RESULTS: Deep venous and/or saphenofemoral insufficiency were detected in 61 of the 81 extremities. The cuff deflation technique was superior at the popliteal vein and caudal segment of the great saphenous vein. The Valsalva maneuver was superior at the superficial femoral vein. The statistical results did not change when the McNemar test was repeated for reflux exceeding 2000 msec. CONCLUSION: Combined application of Valsalva maneuver and pneumatic cuff techniques will lead to more accurate evaluation and increased detection of lower extremity venous insufficiency.

Adolescent↗

Venous circulation in the maternal lower limb: a Doppler study with the Valsalva maneuver.

In order to evaluate the normal physiology of the maternal venous circulation, Doppler examinations of the venous system in the right inferior extremity and suprainguinal part of the common femoral vein were carried out in 38 healthy pregnant women, in 12 non-pregnant controls and in 16 women at early puerperium. Examinations were carried out when the mother was lying in a left semi-recumbent supine position. Blood flow velocities in the suprainguinal femoral and deep femoral veins decreased significantly in the first trimester and were almost normalized by the third postpartum day. Continuous forward venous flow with respiratory fluctuation was maintained in the femoral veins over the whole gestational period. The response to the Valsalva maneuver was similar in the pregnant and non-pregnant women. Our findings provide evidence that the venous valvular system and wall distensibility in the femoral area and the inferior extremity are in vivo not greatly changed in pregnancy. A more important reason for decreased velocities is probably the pregnancy-associated decrease of the arterial input to this area.

Adult↗

Bedside intravascular ultrasound-guided vena cava filter placement.

OBJECTIVE: Several reports have demonstrated the efficacy of inferior vena cava filter (IVCF) placement with intravascular ultrasound guidance (IVUS). The majority of these procedures,however, have been done in concert with contrast venography and/or fluoroscopic guidance. The purpose of this report was to evaluate the potential for bedside IVCF placement with "real-time" IVUS guidance only. DESIGN OF STUDY: In a phase I trial, 10 patients underwent IVUS interrogation of the IVC for diameter measurements and localization of the renal veins. Contrast venography verified the IVUS findings prior to filter deployment. In a phase II trial, another 35 patients underwent intensive care unit bedside placement of an IVC filter with only "real time" IVUS guidance using a double puncture technique in the same femoral vein. All patients underwent color-flow ultrasonography of the femoral veins after filter placement to rule out post procedure femoral vein thrombosis and plain radiographs of the abdomen to identify filter location. RESULTS: In the phase I trial, all filters were placed within 15 mm of the most inferior renal vein identified by IVUS. There were no complications, and successful filter placement was verified by contrast venography. In phase II, 33 IVCFs were placed without complications at approximately the L2 level by plain radiograph. One patient had an IVCF deployed in the common iliac vein, which necessitated placement of an uneventful second IVCF at the infrarenal location by IVUS. This same patient had a femoral deep venous thrombosis identified by postoperative duplex ultrasonography. A second patient had IVC thrombus identified by IVUS, and placement was performed with contrast venography in the fluoroscopy suite. IVC measurements ranged from 18-28 mm in diameter. CONCLUSIONS: IVUS accurately measures the IVC diameter and localizes the renal veins, allowing for exact placement of IVCFs. IVUS further avoids the need for contrast agents and for transport of critically ill patients. Bedside insertion of an IVcF with IVUS guidance is simple, safe, and accurate. Further assessment of this technique is warranted.

Female↗

Effect of sampling site on early kinetics of blood radioiodide and pertechnetate.

Radioiodide (I) and radiopertechnetate (TcO4) were sampled simultaneously from left ventricle, right atrium, and femoral vein early after intravenous injection to pentobarbital sodium-anesthetized cats. Concentrations of both tracers in femoral vein blood was lower than in left ventricular (arterial) blood, with rapid narrowing of the differences over 20 min and gradual approach to steady state. Right atrial blood concentrations were intermediate. When these data were fitted to three-compartment mamillary models, representing blood and tissue pools, compartment size and kinetics differed according to which sampling site was taken as representative of each cat's blood. We have developed a model incorporating subcompartmentalization of the blood with an exchange compartment connecting to the pulmonary circulation as well as compartments exchanging with peripheral sites. With the use of this model, all data sets fitted well. The pulmonary exchange compartment and a large rapid exchange compartment in the femoral vein drainage areas are essential to reconciling the differences among sampling sites.