PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Biodegradable Delivery Systems”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Effects of a new dexamethasone-delivery system (Surodex) on experimental intraocular inflammation models.

BACKGROUND: To investigate the effects of a new biodegradable dexamethasone drug delivery system, Surodex, in two experimental intraocular inflammation models; endotoxin-induced uveitis (EIU) and experimental autoimmune uveoretinitis (EAU). METHODS: Surodex was inserted into the right anterior chambers (ACs) of rats. In the EIU experiment, protein concentration, cell infiltration, and myeloperoxidase (MPO) activity in the aqueous humor were measured 24 h after injection. Eyes were evaluated histopathologically. In the EAU experiment, firstly, Surodex was administered at various days after immunization. Then, Surodex was administered on day 9 and eyes were evaluated histopathologically. Intraocular cytokine levels (IFN-gamma and IL-4) were investigated. RESULTS: In the EIU experiments, eyes with Surodex exhibited significantly reduced inflammation compared with contralateral controls. Protein concentrations, cell infiltrations, as well as MPO activity were reduced. In the EAU experiments, all rats with Surodex given on days 0 or 7 showed no or significantly reduced inflammation in both eyes. Rats treated on day 12 developed reduced inflammation only in the treated eyes. IFN-gamma levels were significantly lower in the eyes with Surodex, whereas IL-4 was not detectable. CONCLUSIONS: This new, biodegradable corticosteroid drug-delivery system is highly effective in suppressing intraocular inflammation, and should be a useful tool to manage uveitis in humans.

Animals↗

Biomaterials for drug delivery systems.

Drug delivery systems have unusual materials requirements which derive mainly from their therapeutic role: to administer drugs over prolonged periods of time at rates that are independent of patient-to-patient variables. The chemical nature of the surfaces of such devices may stimulate biorejection processes which can be enhanced or suppressed by the simultaneous presence of the drug that is being administered. Selection of materials for such systems is further complicated by the need for compatibility with the drug contained within the system. A review of selected drug delivery systems is presented. This leads to a definition of the technologies required to develop successfully such systems as well as to categorize the classes of drug delivery systems available to the therapist. A summary of the applications of drug delivery systems will also be presented. There are five major challenges to the biomaterials scientist: (1) how to minimize the influence on delivery rate of the transient biological response that accompanies implantation of any object; (2) how to select a composition, size, shape, and flexibility that optimizes biocompatibility; (3) how to make an intravascular delivery system that will retain long-term functionality; (4) how to make a percutaneous lead for those delivery systems that cannot be implanted but which must retain functionality for extended periods; and (5) how to make biosensors of adequate compatibility and stability to use with the ultimate drug delivery system-a system that operates with feedback control.

Biocompatible Materials↗

Biodegradable alginate microspheres as a delivery system for naked DNA.

Sodium alginate is a naturally occurring polysaccharide that can easily be polymerized into a solid matrix to form microspheres. These biodegradable microspheres were used to encapsulate plasmid DNA containing the bacterial beta-galactosidase (LacZ) gene under the control of either the cytomegalovirus (CMV) immediate-early promoter or the Rous sarcoma virus (RSV) early promoter. Mice inoculated orally with microspheres containing plasmid DNA expressed LacZ in the intestine, spleen and liver. Inoculation of mice with microspheres containing both the plasmid DNA and bovine adenovirus type 3 (BAd3) resulted in a significant increase in LacZ expression compared to those inoculated with microspheres containing only the plasmid DNA. Our results suggest that adenoviruses are capable of augumenting transgene expression by plasmid DNA both in vitro and in vivo.

3T3 Cells↗

Pharmacokinetic study of fibrin clot-ciprofloxacin complex: an in vitro and in vivo experimental investigation.

We prepared a composite of fibrin clot and ciprofloxacin for use as a biodegradable antibiotic delivery system with sustained effect for the treatment of chronic osteomyelitis. In vitro, ten experiments were performed in which 10 mg of ciprofloxacin were incorporated into 4 ml of fibrin clot. The clots were preserved in nutrient broth and incubated at 37 degrees C for a total of 60 days. Every 24 h a broth specimen was obtained, and the ciprofloxacin concentration was determined by microbiological assay. The maximum level of antibiotic was noted on the first day (49.9 +/- 5.1 mg/l). The ciprofloxacin-fibrin clot complexes usually disintegrated after 60 days. In vivo, the fibrin-ciprofloxacin clots were made as previously described. The composite was implanted in the medullary canal of rabbit tibiae, and the antibiotic concentration was measured in bone, muscle, skin and serum. In all tissues around the implant, the concentration of antibiotic exceeded the minimum inhibitory concentration against the common causative organisms of osteomyelitis for 10 days. The implant caused no systemic side-effects, and it is likely to prove clinically useful as a drug delivery system for treating chronic osteomyelitis.

Animals↗

Effect of additives on encapsulation efficiency, stability and bioactivity of entrapped lysozyme from biodegradable polymer particles.

Low encapsulation efficiency, incomplete and erratic release profiles are the most common features of controlled released protein delivery systems employing biodegradable polymers. In the present study, lysozyme as a model protein was encapsulated in biodegradable microspheres using solvent evaporation method and the effect of amphiphilic stabilizer, a basic salt and a lyoprotectant on microparticle formulation was evaluated. Incorporation rat serum albumin (RSA) in the internal aqueous phase during emulsion increased the encapsulation efficiency of lysozyme and maintained the bioactivity. Use of NaHCO3 improved the encapsulation efficiency of lysozyme from 15-94%, but at the cost of reduced in vitro release characteristics. Incorporation of both RSA and NaHCO3 improved the bioactivity of lysozyme and decreased burst release of the protein from the polymer particle, but reduced the encapsulation efficiency from 90-70%. Addition of sucrose in the internal aqueous phase lowered the encapsulation efficiency which was restored by its addition in the external aqueous phase. Maintenance of internal aqueous phase pH close to the iso-electric point of the protein and osmotic balance between the internal aqueous phase and the external aqueous phase during solvent evaporation method helped in better encapsulation of the protein drug. In vitro release of the lysozyme correlated with the effect of different excipients on entrapment in polymer matrix. Entrapment efficiency as high as 76%, low burst effect and high bioactivity of the entrapped lysozyme was observed from the polymer particles. Use of RSA, sucrose and NaHCO3 helped in a co-operative way towards the formulation of particles entrapping bioactive lysozyme.

Absorption↗

A novel in situ forming drug delivery system for controlled parenteral drug delivery.

The objective of this study was to investigate the in vitro drug (diltiazem hydrochloride and buserelin acetate) release from different in situ forming biodegradable drug delivery systems, namely polymer solutions (in situ implants) and in situ microparticle (ISM) systems. The drug release from ISM systems [poly(d,l-lactide) (PLA) or poly(d,l-lactide-co-glycolide) (PLGA)-solution dispersed into an external oil phase] was investigated as a function of the type of solvent and polymer, polymer concentration and internal polymer phase:external oil phase ratio and was compared to the drug release from in situ implant systems and microparticles prepared by conventional methods (solvent evaporation or film grinding). Upon contact with the release medium, the internal polymer phase of the ISM system solidified and formed microparticles. The initial drug release from ISM systems decreased with increasing polymer concentration and decreasing polymer phase:external oil phase ratio. The type of biocompatible solvent also affected the drug release. It decreased in the rank order DMSO>NMP>2-pyrrolidone. In contrast to the release of the low molecular weight diltiazem hydrochloride, the peptide release (buserelin acetate) was strongly dependent on the polymer degradation/erosion. One advantage of the ISM system when compared to in situ implant systems was the significantly reduced burst effect because of the presence of an external oil phase. ISM systems resulted in drug release profiles comparable to the drug release of microparticles prepared by the solvent evaporation method. Therefore, the ISM systems are an attractive alternative to existing complicated microencapsulation methods.

Buserelin↗

Gelatin nanoparticles produced by a simple W/O emulsion as delivery system for methotrexate.

Biodegradable hydrophilic gelatin nanoparticles, containing different initial amounts of methotrexate (MTX), were prepared using a simple solvent evaporation technique based on a single water-in-oil emulsion and stabilized by the use of glutaraldehyde as cross-linking agent. The effects of several parameters on particle size, drug encapsulation efficiency and drug release were investigated. Size and shape of the nanoparticles were examined by scanning electron microscopy. The release of MTX was monitored in vitro and the mechanism of release was studied. Particles with a mean diameter of 100-200 nm were produced, which were able to release MTX following a diffusion-controlled mechanism of release. It was observed that the initial amount of MTX used for sample loading did not have any effect on the pattern of release, while it affected the amount of drug entrapped into the nanoparticles and also both the release rate and the total amount of drug released.

Journal Article↗

Starch-based biodegradable hydrogels with potential biomedical applications as drug delivery systems.

The design and preparation of novel biodegradable hydrogels developed by the free radical polymerization of acrylamide and acrylic acid, and some formulations with bis-acrylamide, in the presence of a corn starch/ethylene-co-vinyl alcohol copolymer blend (SEVA-C), is reported. The redox system benzoyl peroxide (BPO) and 4-dimethylaminobenzyl alcohol (DMOH) initiated the polymerization at room temperature. Xerogels were characterized by 1H NMR and FTIR spectroscopies. Swelling studies were performed as a function of pH in different buffer solutions determining the water-transport mechanism that governs the swelling behaviour. Degradation studies of the hydrogels were performed in simulated physiological solutions for time up to 90 days, determining the respective weight loss, and analyzing the solution residue by 1H NMR. The mechanical properties of the xerogels were characterized by tensile and compressive tests, as well as by dynamo-mechanical analysis (DMA). Dynamo-mechanical parameters are also reported for hydrated samples.

Aniline Compounds↗

In vivo release of norethindrone coupled to a biodegradable poly(alpha-amino acid) drug delivery system.

The in vivo release of norethindrone from a biodegradable steroid-polymer conjugate was studied in rats. The drug-polymer conjugate, consisting of [3H]norethindrone coupled via a 17-carbonate bond to poly-N5-(3-hydroxypropyl)-L-glutamine was administered to female rats by subcutaneous injection. The in vivo release of steroid, determined by measuring the daily radioactivity output in urine and feces, was fairly constant though it showed a gradual decrease during the 9-month study period. The data indicate that this biodegradable norethindrone-polymer conjugate is a potential candidate for the controlled delivery of norethindrone to effect long-term contraception.

Animals↗

Cyanoacrylate adhesive provides efficient local drug delivery.

Biodegradable drug delivery systems have advanced treatment of a wide spectrum of musculoskeletal problems. However, their lack of availability and cost can restrict use. To find an easily available and inexpensive biodegradable implant, we tested a widely used tissue adhesive, n-butyl-2-cyanoacrylate, as a drug-trapping material. We tested vancomycin with commercially available absorbable gelatin-sponge pieces as the scaffold. We evaluated the in vitro and in vivo drug release profiles and in vivo inflammatory response. A mouse muscle pouch model was used for in vivo evaluations. The released vancomycin level was measured by fluorescence polarization immunoassay technique, and a leukocyte count-based grading system was used to evaluate inflammatory response. Our findings suggest the proposed implant provides effective drug release for as much as 42 days in vitro and 14 days in vivo. The presence of n-butyl-2-cyanoacrylate led to a local inflammatory response which decreased after 3 weeks in the group with less adhesive. These results showed that n-butyl-2-cyanoacrylate could efficiently trap and slowly release a drug when used in the structure of a biodegradable local drug delivery device.

Absorbable Implants↗

Characterization of polymeric poly(epsilon-caprolactone) injectable implant delivery system for the controlled delivery of contraceptive steroids.

Contraceptive steroids levonorgestrel (LNG) and ethinyl estradiol (EE) have been encapsulated with poly(epsilon-caprolactone) (PCL) microspheres using a w / o /w double emulsion method. The microspheres prepared were smooth and spherical, with a mean size from 8-25 microm. In vitro release profiles of microspheres showed a trend of increasing initially at the first week, and thereafter the release was sustained. At the end of the seventh week LNG/EE from 1:5 and 1:10 PCL microspheres were 60 and 48%, 52 and 46%, respectively. An in vitro degradation study shows that at the 20th week the microspheres maintained the surface integrity. The PCL microspheres showed a triphasic in vivo release profile with an initial burst effect due to the release of the steroid adsorbed on the microsphere surface, a second sustained release phase due to the steroid diffusion through the pores or channels formed in the polymer matrix, and third phase due to polymer bioerodible. Histological examination of PCL microspheres injected intramuscularly into thigh muscle of a rat showed a minimal inflammatory reaction demonstrating that contraceptive steroid-loaded microspheres were biocompatible. The level of inflammatory cytokines determined by immunostaining for IL-1alpha, the tissue response to formulations at the first week was considered mild, whereas at the end of the 20th week the inflammatory response ceased. Thus, this study helped us to evaluate the feasibility of using these microspheres as a long-acting biodegradable drug delivery system for contraceptive steroids.

Animals↗

Mathematical modeling of bioerodible, polymeric drug delivery systems.

The aim of this article is to give an introduction into mathematical modeling approaches of bioerodible controlled drug delivery systems and to present the most important erosion theories reported in the literature. First, important parameters such as degradation and erosion are defined and physicochemical methods for their investigation are briefly presented. Then, phenomenological empirical models as well as models based on diffusion and chemical reaction theory are discussed. Due to the significant chemical and physicochemical differences among individual bioerodible polymers used for controlled drug delivery systems, various mathematical models have been developed to describe the chemical reactions and physical mass transport processes involved in erosion-controlled drug release. Various examples of practical applications of these models to experimental drug release data are given. For those involved in the design and development of biodegradable drug delivery systems this will help to choose the appropriate mathematical model for a specific drug release problem. Important selection criteria such as the desired predictive power and precision, but also the effort required to apply a model to a particular system will be discussed. Furthermore, before models can be used for drug release predictions certain parameters such as drug dissolution or polymer degradation rate constants, have to be known. The number of parameters to be determined significantly differs between the models. The practical benefit of carefully choosing the right model is that effects of composition and device geometry on the drug release kinetics can be predicted which can reduce laborious formulation studies to a minimum.

Drug Delivery Systems↗

Long-term release of fluocinolone acetonide using biodegradable fumarate-based polymers.

Intraocular drug delivery systems made from biodegradable polymers hold great potential to effectively treat chronic diseases of the posterior segment of the eye. This study is based on the hypothesis that crosslinked poly(propylene fumarate) (PPF)-based matrices are suitable long-term delivery devices for the sustained release of the anti-inflammatory drug fluocinolone acetonide (FA) due to their hydrophobicity and network density. FA-loaded rods of 10 mm length and 0.6 mm diameter were fabricated by photo-crosslinking PPF with N-vinyl pyrrolidone (NVP). The released amounts of FA and NVP were determined by HPLC analysis. The effects of drug loading and the ratio of PPF to NVP on the release kinetics were investigated using a 2(3-1) factorial design. Overall, FA release was sustained in vitro over almost 400 days by all tested formulations. Low burst release was followed by a dual modality release controlled by diffusion and bulk erosion with release rates up to 1.7 microg/day. The extent of the burst effect and the release kinetics were controlled by the drug loading and the matrix composition. Matrix water content and degradation were determined gravimetrically. Micro-computed tomography was used to image structural and dimensional changes of the devices. The results show that photo-crosslinked PPF-based matrices are promising long-term delivery devices for intraocular drug delivery.

Chemistry, Pharmaceutical↗

Lanthanide bearing microparticulate systems for multi-modality imaging and targeted therapy of cancer.

The rapid developments of high-resolution imaging techniques are offering unique possibilities for the guidance and follow up of recently developed sophisticated anticancer therapies. Advanced biodegradable drug delivery systems, e.g. based on liposomes and polymeric nanoparticles or microparticles, are very effective tools to carry these anticancer agents to their site of action. Elements from the group of lanthanides have very interesting physical characteristics for imaging applications and are the ideal candidates to be co-loaded either in their non-radioactive or radioactive form into these advanced drug delivery systems because of the following reasons: Firstly, they can be used both as magnetic resonance imaging (MRI) and computed tomography (CT) contrast agents and for single photon emission computed tomography (SPECT). Secondly, they can be used for radionuclide therapies which, importantly, can be monitored with SPECT, CT, and MRI. Thirdly, they have a relatively low toxicity, especially when they are complexed to ligands. This review gives a survey of the currently developed lanthanide-loaded microparticulate systems that are under investigation for cancer imaging and/or cancer therapy.

Animals↗

Nanoparticle formulation enhances the delivery and activity of a vascular endothelial growth factor antisense oligonucleotide in human retinal pigment epithelial cells.

The objective of this study was to investigate the delivery and activity of a vascular endothelial growth factor (VEGF) antisense oligonucleotide in a human retinal pigment epithelial cell line (ARPE-19) using a biodegradable nanoparticulate delivery system. A 19-mer antisense phosphorothioate oligonucleotide (PS-ODN) complementary to bases 6-24 relative to the translational start site of the VEGF mRNA, a sense PS-ODN and a mismatch PS-ODN were examined for the inhibition of secretion and mRNA expression of VEGF using an enzyme-linked immunosorbent assay and reverse transcription-polymerase chain reaction, respectively. Nanoparticles of the antisense oligonucleotides were formulated using a poly(lactide-co-glycolide) (50:50) copolymer using a double emulsion solvent evaporation method. After preparing nanoparticles, drug loading, encapsulation efficiency and particle size were determined. The cells were exposed to either plain solution of oligonucleotide or nanoparticles of oligonucleotide from Day 3 through Day 6. Alternatively, the cells were incubated with PS-ODNs and lipofectin for 4 h on Day 4. In all studies, VEGF secretion and mRNA expression were determined on Day 6. The particle size, drug loading and encapsulation efficiency were 252 nm, 5.5% and 16.5%, respectively. The antisense PS-ODN inhibited VEGF mRNA and protein secretion when delivered using nanoparticles or lipofectin but not in its free form. This was consistent with the ability of nanoparticles and lipofectin to elevate the cellular uptake of the oligonucleotide by 4-fold and 13-fold, respectively. Neither mismatch nor sense oligonucleotides inhibited VEGF secretion. In conclusion, biodegradable nanoparticles enhance cellular delivery of a VEGF antisense oligonucleotide and inhibit VEGF secretion and mRNA expression in a human retinal pigment epithelial cell line.

Drug Delivery Systems↗