PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “DENTURE BASES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Bonding acrylic teeth to acrylic resin denture bases: a review.

Partial or complete dentures are more commonly constructed for the elderly group of the population. Teeth debonding from the dentures can be frustrating to the patients as well as the dentist. Research has been carried out and is continuing to study the issue of bonding acrylic teeth to the denture base resin. The present review takes into account the majority of research papers published in the last five decades for determining the bond strength. Selection of more compatible combinations of denture base resins and acrylic teeth may reduce the number of prosthesis fractures and the resultant repairs.

Acrylic Resins↗

Effects of polishing techniques on the surface roughness of acrylic denture base resins.

STATEMENT OF PROBLEM: Rough surfaces of denture bases promote adhesion of microorganisms and plaque formation. It is therefore important to know how different polishing systems affect surface roughness of denture base acrylic resins. PURPOSE: The objective of this study was to compare the effects of 4 chairside polishing kits and 2 conventional laboratory techniques used for polishing 3 different acrylic denture base resins. MATERIAL AND METHODS: Using contact profilometric measurement, the surface texture of 54 specimens (15x30x3 mm) per acrylic material (autopolymerized ProBase Cold, heat-polymerized ProBase Hot, and injection heat-polymerized SR Ivocap plus) was studied before and after cutting with a tungsten carbide bur, and during and after chairside polishing with 4 polishing kits (Exa Technique, Acrylic Polisher HP blue, AcryPoint, Becht Polishing Cream), and after conventional polishing with 2 polishing systems (Universal Polishing Paste for Resins and Metals, Lesk Polishing Liquid). There were 9 specimens for each acrylic resin material and polishing method combination. Conventional lathe polishing with polishing paste served as the control. Mean average surface roughness (Ra) values of each specimen group were analyzed using a 2-way analysis of variance, the Scheffé post-hoc test, and paired t test (alpha=.05) with the Bonferroni adjustment. After testing the polished acrylic resin surfaces were evaluated under a scanning electron microscope. RESULTS: The highest mean average surface roughness (Ra=2.86+/-0.8 microm to 3.99+/-1.31 microm) was measured for surfaces finished with a tungsten carbide bur. The lowest surface roughness values (Ra=0.02+/-0.01 microm) were determined for acrylic resin specimens polished with a lathe and polishing paste. The Ra values of resin specimens after polishing with chairside silicone polishing kits ranged from 0.05+/-0.0 microm to 0.35+/-0.05 microm. Mean average Ra values of specimens polished with a polishing cream alone (Ra=1.01+/-0.17 microm to 1.68+/-0.47 microm) were significantly higher (P<.05) than those obtained with other polishing systems tested, which was confirmed by scanning electron microscope images of acrylic resin surfaces. Significant differences in mean average surface roughness were found between autopolymerizing and injected heat-polymerizing resin specimens. In addition, scanning electron microscopy revealed increased porosity of autopolymerizing resin specimens. CONCLUSIONS: Conventional laboratory polishing was found to produce the smoothest surface of denture base acrylic resin. Chairside silicone polishing kits produced a significantly smoother surface of acrylic resin than specimens polished with a tungsten carbide bur. The presence of large pores was characteristic for the autopolymerizing resin material.

Acrylic Resins↗

[Studies on the thinning of the upper acrylic resin complete denture with the reinforced palate. (Part 1). Thinning of the resin denture base with the standard shape (author's transl)].

The acrylic denture bases are most commonly used as compared with metallic denture bases at present. For this reason, it is due to many excellent properties, for example, simple processing, easy repair, cheapness and so on. But an inherent disadvantage is liability of an acrylic denture base to make thick so as to maintain stiffness and strength and it makes patients uncomfortable. Therefore, the purpose of this paper is to make the palatal region of the upper complete denture thin with about 0.7 mm in thickness, and to keep the same mechanical properties as the normal resin dentures using the composites materials with carbon cloth. Tensils test of the plate test-piece and uniform bending test of the upper complete denture with steel wings were respectively performed. The results obtained in this investigation are as follows: 1) The acrylic composites reinforced with carbon cloth have shown the superior mechanical properties to be compared with the acrylic resin to be generally used. 2) The thickness of the reinforced thin denture is decreased to 0.7 mm (its thickness is 60% of the normal thickness of the one), nevertheless, the stiffness and strength are increased with the using of the composite materials. 3) The region of highest surface tensile stress in the denture was on the polished surface of the palatal aspect of the denture in the area immediately behind the anteriors, but at this region, the strain of the reinforced thin denture base decreased its strain 10% in comparison with the non-reinforced normal thick one.

Acrylic Resins↗

[Notch effect on the fatigue strength of the denture base resin. (Part 3). Effect of reinforcement for composite material with notch (author's transl)].

The denture base which is made from the acrylic resin often occurs the fracture during function, and it is known that this fracture is mainly occured by the fatigue fracture, which is happened by the crack growth from the location of high stress. Until now, the author discussed on the fatigue properties about the specimens with semi-circular notch as the model of the remaining natural teeth, but these results are not easily applied to the design of denture base because the shape of denture base, considering its function and esthetics, is not changed. So, for the improvement of the strength of denture base, the denture base might be used the reinforcement. And, used as a trial the organic fiber as reinforcement, and their effects were investigated from the sides of the bending moment at fracture and the strain distribution occurs the fracture at the posterios palatal area, and its strength is improved 190%. And the fracture of the complete denture happens in general at the location between two central incisors, therefore this problem should be considered as the notched effect. So, reinforcing the lingual part of maxillary anterior teeth using the organic fiber, its strength is improved 53% comparing with the general complete denture. Therefore, the effects of reinforcement were enough appeared, and the improvement of the strength of denture base is very expected in dental use.

Composite Resins↗

Construction of denture bases from pour resins.

Satisfactory dentures can be produced from pour resins at a considerable saving of processing time. The problems of porosity, voids, and heavy anterior tooth contact resulting from shrinkage of the resin during curing present difficulties which must be understood to be compensated for. The use of alginate and a recently introduced modified gypsum product as investing media, as well as centrifugation of the pour resin into the flask, offer no significant advantages over the originally introduced procedure. Further critical research will conceivably improve the pour resins and the corresponding processing techniques to the point that they can challenge heat-curing resins for the largest percentage of denture bases.

Alginates↗

Strength of relined denture base polymers subjected to long-term water immersion.

PURPOSE: This study was undertaken to characterize the long-term equilibrium flexural strength at proportional limit (FSp) of 4 denture reline polymers processed onto 4 denture base polymers. MATERIALS AND METHODS: A 3-point flexural test was applied on rectangular specimens of each denture base polymer-denture reline polymer. Each specimen was immersed in water for 4 months prior to and 4 months after reline. RESULTS: Significant differences existed among the relined specimens because of the denture base polymer variable, the denture reline polymer variable, and their interaction (P < 0.05). The descending order in FSp according to the denture base polymer, arranged in terms of statistical significance was: Acron approximately Acron MC > Triad > Palapress Vario, where approximately denotes no significant difference between Acron and Acron MC. The descending order in FSp according to the denture reline polymer, arranged in terms of statistical significance was: Triad > Rebaron > Rebaron LC > Tokuso Rebase. Significant difference existed among all of the denture reline polymers. CONCLUSION: The present study showed that the long-term equilibrium strengths of 4 denture reline polymers processed onto 4 denture base polymers were different. The strength of the relined specimen of a denture base is dependent on the strength of the denture base polymer and that of the reline polymer.

Acrylic Resins↗

[The effect of woven glass fiber reinforced composites on the transverse strength of three denture base resins].

PURPOSE: This study evaluated the effect of woven glass fiber reinforced composite (FRC) on transverse strength of denture base materials. METHODS: Three denture base resins (heat-activated resin, autopolymerizing resin and microwave-activated resin) and FRC (Vectris Frame, Ivoclar-Vivadent) were selected for the study. The FRC was light-cured and sandwiched in the middle of denture base resin and then the specimen was polymerized according to manufacturers' instructions in a gypsum mold with a cavity of 65 mm x 10 mm x 2.5 mm. Each specimen was immersed in 37 degrees C distilled water for 50 hours. The control group was without FRC. Ten specimens were fabricated for each group. The transverse strength test was performed on a universal testing machine at a crosshead speed of 5 mm/min. RESULTS: The transverse strengths of all denture base resins reinforced with FRC were significantly higher than that of denture base resin bulk. CONCLUSIONS: Within the limitation of the current study, the FRC has an effect upon reinforcement of denture base resin.

English Abstract↗

The effect of aesthetic fibres on the strength of acrylic resin denture base material.

Aesthetic fibres are added to denture base polymers to simulate the natural appearance. The aim of this study was to measure the effect of aesthetic fibres on the low strain rate transverse bend strength and the high strain rate impact strength of an acrylic resin denture base material. Varying amounts of 2 and 4 mm Viscose Rayon aesthetic fibres, ranging from 0.1 to 3%, were incorporated into the polymer to evaluate their effect on these strength properties. The results showed that the fibres had minimal physical effect and that bonding of the fibres to the denture base polymer is not uniform or complete.

Analysis of Variance↗

Influence of loading positions of mandibular unilateral distal extension removable partial dentures on movements of abutment tooth and denture base.

PURPOSE: The aim of our study was to explore the effects of different loading positions on the movements of the abutment tooth and denture base of removable partial denture with unilaterally designed framework (RPD-U). MATERIALS AND METHODS: The experiment was carried out with a simulation model of a mandible without left molars. The movements of abutment tooth and denture base of the unilateral and bilateral designs were due to 30N vertical load on 12 loading positions determined with a strain gauge circuitry. The effects of loading positions on the movements of the abutment tooth and denture base were compared between two designs. RESULTS: During the loading on buccal, lingual positions, and the most disto-central position the movements of the abutment tooth and denture base of the unilateral design were significantly greater than those of the bilateral design (P < 0.01). During the loading on the three mesio-central positions the movements of the abutment tooth and denture base were equal between designs, and were significantly lower than during the loading on the other positions (P < 0.01). CONCLUSION: Ending the denture teeth at the mesial cusp of second molar and positioning the occlusal contacts over the ridge crest adequately stabilize the abutment tooth and denture base of RPD-U.

Acrylic Resins↗

Leaching from denture base materials in vitro.

Specimens made from denture base materials were leached in Ringer solution and in ethanol. The specimens comprised a heat-cured product processed in two different ways and two cold-cured materials. The organic compounds leaching from the specimens to the solutions were separated, identified, and quantified by a combined gas-chromatography and gas-chromatography/mass-spectrometry technique. Additives and degradation products, possibly made by free radical reactions, were released from the denture base materials. In Ringer solution only phthalates could be quantified. In ethanol solvent, biphenyl, dibutyl phthalate, dicyclohexyl phthalate, phenyl benzoate, and phenyl salicylate were quantified. In addition, copper was found in the ethanol solvent from one of the denture base materials. The amount of leachable organic compounds varies among different materials. Processing temperature influences the initial amount of leachable compounds.

Benzoates↗

Effect of adhesive primer developed exclusively for heat-curing resin on adhesive strength between plastic artificial tooth and acrylic denture base resin.

Despite progress in the development of denture base resin and artificial tooth materials, dental clinics are still plagued with artificial teeth falling off the denture base--due to poor bond strength--after denture delivery. Against this background, this study sought to examine the effect and durability of an adhesive primer developed exclusively for heat-curing resin on the adhesive strength of heat-curing denture base acrylic resin to plastic artificial tooth. Test specimens were divided into four groups according to the treatment method of the artificial tooth's test bonding surface: air abrasion, adhesive primer application, adhesive primer application after air abrasion, and pretreatment only (control). After heat curing of acrylic resin onto the bonding surface, shear test was performed for two storage periods: 24-hour versus 100-day water storage. From the results obtained, it was revealed that the evaluated adhesive primer was significantly effective in increasing adhesive strength between artificial tooth and acrylic resin, although specimens were stored in water for 100 days.

Acrylic Resins↗

Reinforcement of poly(methyl methacrylate) denture base with glass flake.

OBJECTIVES: Since the introduction of poly(methyl methacrylate) as a denture base material, it has suffered from having relatively poor mechanical properties. Many methods of improving its strength and toughness have been investigated. Most of these have not been adopted due to: increased cost, the need for specialist processing equipment or increased laboratory time due to more complicated procedures. Glass flake has been used as a reinforcing agent in many industrial polymers, but is as yet untested with denture base acrylic materials. The aim of this study is to evaluate the effect of adding glass flake to denture base acrylic powder on the fracture toughness of the set material. METHODS: Glass flake was added in 5, 10 or 20% w/w to Trevalon denture base powder. The material was mixed, flasked, packed and processed in a manner typical for a denture base material. Fracture toughness was determined using a double torsion test technique. RESULTS: The addition of glass flake gave up to a 69% increase in fracture toughness compared to plain Trevalon material. The addition of 5% glass flake lead to an improvement in fracture toughness that was statistically significant compared to both plain Trevalon and the 10 and 20% groups. SIGNIFICANCE: The significant improvement in fracture toughness of a denture base acrylic material using glass flake is an extremely promising result. Other mechanical properties will require testing before glass flake can be recommended as a reinforcing agent for denture base acrylic materials.

Dental Materials↗

Denture base resins: comparison study of color stability.

Several denture base resins have been recently introduced that provide easier or faster processing. Although these materials have adequate strength properties, the color stability is also of interest. This study evaluated the color stability of five denture base acrylic resins and one denture base repair resin. The samples were subjected to conditions of accelerated aging to test color stability. Five samples of each material were processed and aged for 100 and 300 hours. The color stability was quantitatively measured using the Minolta Chroma Meter II. Color measurements were made before weathering and at 100 and 300 hours the color difference delta E was calculated for all samples. At 300 hours the color change of the materials was significantly different at p less than 0.01. It was found that: (1) the color of Lucitone Hy-pro and Acron was least affected by conditions of accelerated aging; (2) Triad, Accelar 20, and Perm demonstrated noticeable color changes; and (3) Compak-20 had an appreciable color change and was the least color-stable of the materials tested.

Acrylic Resins↗

The effect of diabetes mellitus on histopathological changes in the tissues under denture base and without mechanical pressure.

Histopathological changes in the tissues under a denture base were studied with respect to the difference between diabetic and normal rats. Diabetes mellitus was induced in Wistar rats by streptozotocin. The experimental denture base was designed to make contact with the palatal mucosa without any continuous nor masticatory pressure. Histopathological observation periods were 1, 2, 4, 8, 12 and 20 weeks after the insertion of the denture base. Histopathological examination revealed that only the transient slight proliferative reaction observed in mucosal epithelium under a denture base in normal non-diabetic rats, was lessened by induced diabetes mellitus. Moreover, covering the palatal mucosa with a denture base without any continuous nor masticatory pressure and with the maintenance of mucosal cleanliness under it and of the denture itself, did not cause any inflammatory change or bone resorption in the tissues under the base.

Acrylic Resins↗