PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Removable”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Esthetic considerations in the construction of a removable partial denture.

In the construction of a removable partial denture, the patient's interest frequently lies in the improvement of his or her esthetic appearance. This desire can be underestimated by the scientifically trained dentist, resulting in a disappointed patient. The perimeters of potential esthetic improvement might be influenced by the limitations of each individual case. However, appropriate care in the selection, arrangement, and position of teeth can overcome some of the limitations. This article describes the benefits of a well-planned, systematic approach to selection of the framework design, porcelain shade, and tooth mold as well as the base finish, and it illustrates, with specific examples, how to achieve the maximum esthetics in removable partial denture prosthodontics.

Acrylic Resins↗

Clinical evaluation of removable partial denture rest seat adaptation.

The clinical relationship between the removable partial denture cast occlusal rest and the corresponding rest seat was examined. Under the conditions of the study, it was found that rests of mandibular Class I and II removable partial dentures fit significantly better than those of mandibular Class III and IV prostheses. No significant difference was noted between similar types of maxillary removable partial dentures in this regard. In evaluating the fit of specific portions of the occlusal rest, it was found that the marginal ridge zone was more closely adapted to the rest seat than other zones for all types of removable partial dentures. However, contact, as defined in this analysis, was found to exist on a random basis in all four quadrants of the occlusal rests evaluated. In spite of this fact, one fifth of the occlusal rests did not contact the opposing rest seat at any point. Improved fit with length of service was not substantiated by a cross-sectional analysis. Suggestions were made to assist the clinician in achieving a better fit between the framework and dentition in removable partial dentures.

Dental Abutments↗

In vitro investigation of the wear of resin composite materials and cast direct retainers during removable partial denture placement and removal.

The purpose of this study was to determine whether wear of two resin composite materials and contacting I-bar clasp tips would occur within a simulated RPD placement and removal period of 2 years. The data were compared to enamel with contacting I-bars. Cast I-bar clasps were passed over each specimen in the resin composite and tooth experimental groups (n = 10). Computer digitized image analysis of SEM photomicrographs of the specimens provided data for analysis of wear. Results indicated a statistical difference in the amount of mean wear between the two resin composites and between the I-bar groups. The results from this study suggest that the selection of a resin composite for use as a RPD retentive undercut must be carefully undertaken to avoid excessive wear and loss of retention.

Analysis of Variance↗

The swing-lock denture: its use in conventional removable partial denture prosthodontics.

This article describes the uses of the swing-lock retained removable partial denture in partially dentate patients where the potential for achievable retention with a conventionally designed removable partial denture is less than adequate. The article presents two case reports detailing effective use of the swing-lock concept in removable partial denture design and it is hoped that this article will increase the awareness of practitioners to the use of this prosthesis type when planning removable partial dentures.

Aged↗

The tooth-removable partial denture interface.

During the metal finishing phase of removable partial denture construction, metal is removed from all aspects of the casting. The amount removed from areas designed to contact prepared surfaces of abutments is critical to the resulting fit of the partial. Castings were evaluated before and during finishing procedures to measure metal loss at the tooth-removable partial denture interface. Finishing and fitting techniques for controlling the loss of metal are presented.

Calibration↗

Removable partial denture design in Alberta dental practices.

Studies published in the dental literature have found, all too frequently, that dentists do not pay adequate attention to the design of cast removable partial denture frameworks. This study investigated removable partial denture design in Alberta dental practices. The authors considered various issues related to surveying, partial denture design, and provider education, as well as the possible collaboration of clinical dentistry with denturism in removable partial denture treatment. Although the study found that a significant proportion of Alberta's dentists get involved in designing the cast framework, relatively few undertake surveying. Instead, surveying tends to be deferred to dental technicians. As was the case in other studies, no clear reason for this trend emerged, and it appeared to be unrelated to remuneration or time utilization issues. Responding dentists perceived that their undergraduate education was adequate for providing removable partial denture care. The study also identified a need for small, hands-on continuing education courses. About half of the respondents indicated that it is appropriate for dentists to collaborate with denturists on complete denture care. However, very few respondents considered it appropriate to refer to, or collaborate with, denturists in removable partial denture care.

Alberta↗

Complications and failures in removable partial dentures: a clinical evaluation.

The design of removable partial dentures (RPDs) is an important factor for good prognostication. The purpose of this study was to clarify the effectiveness of denture designs and to clarify the component that had high rates of failure and complications. A total of 91 RPDs, worn by 65 patients for 2-10 years, were assessed. Removable partial dentures were classified into four groups: telescopic dentures (TDs), ordinary clasp dentures (ODs), modified clasp dentures (MDs) and combination dentures (CDs). The failure rates of abutment teeth were the highest and those of retainers were the second highest. The failure rates of connectors were generally low, but they increased suddenly after 6 years. Complication and failure rates of denture bases and artificial teeth were generally low. Complication and failure rates of TDs were high at abutment teeth and low level at retainers. Complication and failure rates of ODs were high at retainers.

Adult↗

Influence of clasp design of distal extension removable partial dentures on the periodontium of the abutment teeth.

Three removable partial denture designs were investigated to determine the effect of minor connector configuration on the periodontal health of abutment teeth. Twenty-five patients wore three different removable partial dentures for 19 weeks each. The first removable partial denture placed a tilting force on the abutment teeth; the second was stress-releasing; and the third collected the least amount of plaque. Plaque accumulation, the condition of the periodontium, migration of the abutment teeth, deformation of the clasp arms, retention of the prosthesis, and patient preferences were assessed. The results demonstrated that the partial denture retentive design did not affect plaque formation. The prosthesis designed to place a tilting force on the abutment teeth appeared to cause the least mobility and migration of the abutments and had the greatest acceptance by the patients.

Dental Abutments↗

A survey of dentitions and removable partial dentures constructed for patients in North America.

The prevalence of removable partial dentures in North America is not known. This study was designed to collect information about (1) the indications for, (2) the teeth to be replaced with, and (3) the type of major connectors used in removable partial dentures. Five commercial dental laboratories situated in different regions of North America were selected to give as wide as possible a view of the production of removable partial dentures. Each laboratory was asked to provide details of 300 consecutive removable partial dentures. Photographs (35 mm) of master casts and processed partial dentures were obtained for more than 1300 patients. The color slides were analyzed and the remaining teeth and types of dentures were recorded. The dentures were classified as follows: cast frame denture, acrylic resin denture with or without some wrought metal, and acrylic resin denture with some cast units. The major connectors were classified as one of seven alternatives in the maxillae, and as one of six alternatives in the mandible.

Canada↗

Evaluation of articulation of Turkish phonemes after removable partial denture application.

In this study, the adaptation of patients to removable partial dentures was evaluated related to articulation of Turkish phonemes. Articulation of /t,d.n,l,r/, /g,k/, /b,p,m/ and /s,z,ş,v,f,y,j,h,c/ phonemes were evaluated by three speech pathologists, on records taken from 15 patients before the insertion of a removable partial denture, just after insertion, and one week later. The test consisted of evaluation of phoneme articulation of independent syllables in terms of distortion, omission, substitution, mass effect, hypernasality and hyponasality. Data were evaluated with Cochrane Q. McNemar and Kruskal-Wallis tests. The results showed that for some phonemes, problems in articulation occurred after the insertion of a removable partial denture while for others a significant amelioration was observed after the insertion of a removable partial denture. In general, problems in articulation of evaluated phonemes were resolved after one week of use.

Adult↗

A clinical study of the periodontal status of abutment teeth supporting swinglock removable partial dentures--a pilot study.

Eleven patients wearing mandibular swinglock bilateral distal extension removable partial dentures opposing maxillary complete dentures were studied for a period up to 2 years. They had moderate to advanced periodontal disease with retrograde mobility patterns. Periodontal therapy, as well as treatment of dental carious lesions, was completed before fabrication of the prosthesis. Recordings of the gingival status, pocket depth, plaque score, tooth mobility, and dental caries were made at the time of the placement of the prosthesis and thereafter at 6-month intervals. Final results were obtained at the end of 2 years in six patients (group A) and at 1 1/2 years in five patients (group B). Our findings show that both groups had a statistically significant increase in gingival inflammation. However, no differences in degree of inflammation were observed between the two groups with regard to the status of gingival tissues that were covered and uncovered by the components of the swinglock removable partial denture. Also, no statistically significant differences in pocket depths and plaque scores were found between the time of placement of the swinglock removable partial denture and the final recall visit. Of the 61 abutment teeth, 85.2% had no significant change in mobility, 11.5% showed a substantial decrease in mobility, and 3.3% showed a considerable increase in mobility. The patients were able to successfully wear the swinglock removable partial denture without clinically significant changes in the supporting structures of the abutment teeth. This report is part of an ongoing study to determine the efficacy of swinglock removable partial dentures.

Adult↗

Repair of a removable partial denture using gold occlusals.

Limited interarch space causes maintenance problems with removable partial dentures. The problem of abrasion and breakage of acrylic resin teeth, the concomitant supraeruption of opposing natural teeth, and possible decrease of vertical dimension of occlusion can be prevented or minimized with cast-gold occlusals. Use of metal occlusals has been advocated on newly constructed removable partial dentures, but not on existing prostheses with severely worn or broken denture teeth. This article describes a repair procedure for a removable partial denture where minimal interarch distance resulted in wear and breakage of denture teeth. A thin, abraded denture tooth that had been repaired numerous times was prepared and covered with a cast gold restoration. The problem of abrasion and breakage of the acrylic resin tooth was solved and the service life of the prosthesis was extended.

Acrylic Resins↗

Clinical effect of removable partial denture prepared by Saddle-Lock hidden-clasp.

OBJECTIVE: To study the method for preparing removable partial denture using Saddle-Lock hidden-clasp and evaluate its clinical effect. METHOD: Casting process was adopted for the preparation of the clasp, which was fixed at the points on the mesial and distal surfaces of the abutment tooth. The clinical records of 305 patients treated with such removable partial dentures were reviewed. RESULTS: Within a follow-up period of 6 years, 295 of the 305 patients retained good abutment condition and were satisfied with the denture that was capable of easy wearing and removing. CONCLUSIONS: Removable partial denture made by Saddle-lock hidden-clasp exhibits good performance in fixation and stability. As an innovation of traditional design of partial denture clasp, it is simple to prepare and well received by the patients with good clinical effect.

Adult↗

The construction of crowns for removable partial denture abutment teeth.

The construction of crowns for teeth that will serve as abutment teeth for removable partial dentures is an important and technically demanding procedure. The preparation of the tooth itself must include provision for the components and path of placement of the removable partial denture and at the same time conform to all the parameters associated with proper tooth preparation. Some of the factors unique to surveyed crowns that must be considered include the position of the tooth in relation to the proposed occlusal plane with the removable partial denture, the type of facial and lingual tooth contours desired for the direct retainer, the size and suitability of existing restorations, and the proposed path of placement and removal of the removable partial denture relative to the orientation of the abutment tooth as well as to other adjacent teeth if the abutment also is to be used as a fixed partial denture retainer. The design requirements for the removable partial denture must be determined before treatment is initiated, to account for all of these factors.

Crowns↗

Periodontal problems associated with use of distal extension removable partial dentures--a matter of construction?

It is commonly assumed that a distal extension partial removable dentures rotates around the supporting rests when the saddle is occlusally loaded and that this rotation may expose the abutment teeth to a distal torque believed to be potentially harmful to their periodontal tissues. Attempts are therefore often made to counteract this effect through the denture construction. However, a review of relevant literature does not appear to substantiate an unqualified acceptance of the above mentioned assumptions, nor of the beneficial effect of special denture constructions designed to reduce the abutment loading. On the other hand, well controlled longitudinal studies seem to indicate that a favourable periodontal prognosis may be expected in such cases provided the following conditions are satisfied: Periodontal problems should be treated and an adequate oral hygiene established prior to the insertion of the denture; The periodontal health and oral hygiene should be maintained through regular recalls. During these recalls possible prosthodontic defects should be diagnosed and necessary measures implemented.

Animals↗