PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Endoscopy, Digestive System”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Patency and complications of percutaneously inserted metallic stents in malignant biliary obstruction.

PURPOSE: The aim of this study was to analyze the patency of percutaneously inserted metallic stents in malignant biliary obstruction and to evaluate all the complications associated with the stents and the reinterventions needed. MATERIALS AND METHODS: Thirty-nine patients with 42 malignant strictures were treated percutaneously with 55 metallic self-expandable stents. Forty-eight were Wallstents and seven were Memotherm stents. Twenty-five strictures were hilar, 16 were in the common bile duct, and one was in the hepaticojejunal anastomosis. The patients were followed until death and the mean follow-up was 6.4 months. RESULTS: Stent insertion was successful in 97% of the patients. Thirty percent had early complications (<30 days), and as many as 66% had late complications, including stent occlusions, which were seen in 10 patients. The patency rates of patients with cholangio-carcinoma were significantly lower than those of the patients with other diagnoses. There was also a tendency toward obstruction with less dilation of the stents, Y, T or tandem-style stent placement, an increasing number of stents, longer strictures, and hilar strictures. Thirty-one percent of the patients alive after the first 30 days had late reinterventions. CONCLUSIONS: Although metallic stents offer an alternative in the palliation of malignant bile duct obstruction, there seem to be numerous early and late complications.

Aged↗

Propofol versus traditional sedative agents for gastrointestinal endoscopy: a meta-analysis.

BACKGROUND & AIMS: Even though propofol has better recovery profile than traditional agents, its use is limited because of the perception of increased complication rates. Because an adequately powered trial comparing risk of propofol with traditional agents is lacking, we performed a meta-analysis of the current literature. METHODS: We searched Medline (1966-October 2004), EMBASE (1980-October 2004), and Cochrane controlled trials registry. The following 4 cardiopulmonary complications were assessed: hypoxia, hypotension, arrhythmias, and apnea. Procedures were divided into 3 groups: esophagogastroduodenoscopy group, colonoscopy group, and endoscopic retrograde cholangiopancreatography/endoscopic ultrasonography group. Pooled odds ratios for complications were calculated for all the procedures combined and then separately for the 3 groups. Random effects models were used for 2-proportion comparisons. RESULTS: Of the 90 citations identified, 12 original studies qualified for this meta-analysis and included 1161 patients. Of these, 634 received propofol, and 527 received midazolam, meperidine, and/or fentanyl. Most of the included studies were randomized trials of moderate quality and nonsignificant heterogeneity (Cochran Q = 4.81, P = .90). Compared with traditional sedative agents, the pooled odds ratio with the use of propofol for developing hypoxia or hypotension for all the procedures combined was 0.74 (95% confidence interval [CI], 0.44-1.24); for EGD, 0.85 (95% CI, 0.33-2.17); for colonoscopy, 0.4 (95% CI, 0.2-0.79); and for ERCP/EUS, 1.07 (95% CI, 0.38-3.01). CONCLUSIONS: Propofol sedation during colonoscopy appears to have lower odds of cardiopulmonary complications compared with traditional agents, but for other procedures, the risk of complications is similar.

Apnea↗

The dyspeptic syndrome in migraine: morphofunctional evaluation on 53 patients.

The authors, in order to evaluate the important role of gastrointestinal dysfunction during the migraine attack, have studied 53 patients with migraine without aura during the asymptomatic stage between attacks. Patients were examined functionally with a pH meter test of the gastroesophageal tract over 24 hours and morphologically with esophagogastroduodenoscopy. The results of this study point out that in a high percentage of patients with migraine, both evaluations are normal. The authors suggest the possibility of detecting, even hypothetically, an alteration of the common neurotransmitter substrate in the origin of migraine attacks and accompanying symptoms.

Adult↗

Endosonography and endoscopic magnetic resonance imaging.

Endosonography is an important modality for the diagnosis and staging of oesophageal, gastric, colorectal and pancreatobiliary malignancy. It is also recognized as a reliable method for the evaluation of submucosal tumours of the gastrointestinal tract, for differentiating benign lesions from giant gastric folds, and for the localization of pancreatic endocrine tumours. The latest development, that of endosonographic fine-needle aspiration, provides for the cytological diagnosis of gastrointestinal tumours. This new technique may also be used for endoscopic therapy. High-frequency probes can be used to make a more accurate diagnosis of superficial carcinoma of the gastrointestinal tract, for three-dimensional imaging of gastrointestinal tumours and for intraductal ultrasonography of the bile duct and pancreatic duct. Endoscopic magnetic resonance imaging provides information not obtainable with endosonography or other modalities. It has high potential in the diagnosis and staging of gastrointestinal and pancreatobiliary tumours.

Biliary Tract Neoplasms↗

Endoscopic mucosal resection.

We are now finding more malignancies in their early stages than previously. Attempts to ablate these lesions are difficult and do not provide the histological information required to decide on further treatment. Surgery is difficult to justify, as only a minority of lesions are associated with lymph node metastases and lesions may not become clinically relevant within the lifetime of an elderly patient. Endoscopic mucosal resection allows cancers to be resected at minimal cost, morbidity and mortality. It is also the most reliable investigation when assessing lesions which are suspicious for containing early cancer. After endoscopic removal, histological assessment of depth of penetration and a search for invasion into lymphatics or venules allows the risk of microscopic lymph node metastases to be predicted. The risk of developing metastatic disease can then be balanced against the risks of surgery in view of the patient's age and health.

Biopsy↗

Technical modifications and strategies for stenting gastric outlet strictures using esophageal endoprostheses.

BACKGROUND AND STUDY AIMS: The outcome of stenting gastric outlet stricture is favorable compared with a bypass operation which has significant morbidity and mortality. In Japan, this procedure is particularly complicated by a lack of enteral stents. We report some technical stratagems for stent placement for gastric outlet strictures. PATIENTS AND METHODS: Between February 1993 and July 2001, 23 patients with gastric outlet strictures (14 men, nine women; mean age 72 years) underwent stent placement using an esophageal stent system. The Ultraflex or Z-stents were used in 18 or five patients, respectively. With the Ultraflex, we increased the length of the delivery system. Some patients underwent stent placement with the help of endoscopic assistance with a grasping forceps or a home-made sheath. RESULTS: The metal stent was successfully inserted in all patients. There were no complications during the procedure. Migration occurred in two out of five patients treated with the Z-stent, whereas there was no migration in patients treated with the Ultraflex stent. In two patients, curable pancreatitis was caused by pressure on the duodenal papilla. One of these patients also experienced bile stasis which required biliary decompression. There were three cases of obstruction, caused by tumor ingrowth (1), hyperplasia (1) and stent fracture (1); recanalization by an additional stent placement and/or cutting stent filaments was successful. All the patients died, with a median survival period of 52 days. There was no procedure-related mortality. CONCLUSIONS: With some technical modification, stent placement for gastric outlet stricture, even using an esophageal stent, is feasible. This procedure offers good palliation with no major complications.

Adult↗

Therapy of anastomotic leaks by means of covered self-expanding metallic stents after esophagogastrectomy.

BACKGROUND AND STUDY AIMS: The mortality rate for surgical revision of gastroesophageal anastomotic leakage after resection for cancer approximates 60 %. The efficacy of endoscopically placed covered metallic stents for treatment of gastroesophageal leakage was evaluated. PATIENTS AND METHODS: Between June 1996 and June 2002 we treated 21 patients with proven gastroesophageal leakage; 18 had anastomotic leakage and three patients had perforation for different reasons. The extent of the leaks ranged from one-quarter of the intestinal circumference to its complete dehiscence. The average time from surgery to detection of leakage was 6.1 days (range 3 - 15 days). Mortality, healing rate, length of hospital stay, and complications were assessed. RESULTS: The insertion of stents was performed endoscopically under radiological guidance without any complication in all patients. In 9.5 % (2/21) of patients complete sealing of the leak was not achieved. The mortality associated with anastomotic leakage was 23.8 % (5/21). In 80.1 % (17/21) patients complete healing of the leakage was achieved. The average hospital stay was 67 days (range 14 - 158 days). Of 23 stents, 13 (56.5 %) were removed, and three patients developed stenosis after removal. CONCLUSION: The treatment of gastroesophageal leakage with covered stents appears to reduce mortality and the complication rate associated with major leakage. Therefore this technique seems to be a reasonable alternative in the treatment of clinically relevant anastomotic leakage.

Adult↗

A randomized trial of unsedated transnasal small-caliber esophagogastroduodenoscopy (EGD) versus peroral small-caliber EGD versus conventional EGD.

BACKGROUND AND STUDY AIMS: Unsedated esophagogastroduodenoscopy (EGD) has advantages over sedated EGD - e. g., prevention of side effects related to sedation, less patient monitoring, and less expense. This study compared the feasibility and tolerance of transnasal small-caliber (TSC-EGD) and peroral small-caliber EGD (PSC-EGD) with conventional EGD (C-EGD). PATIENTS AND METHODS: A total of 150 patients referred for diagnostic EGD were randomly allocated to undergo either TSC-EGD, PSC-EGD, or C-EGD under local anesthesia if they agreed to receive sedation only on demand or in case of intolerance. Patients, endoscopists, and nurses completed questionnaires on the tolerability and quality of the examinations using a visual analogue scale (VAS), ranging from 1 (best/nonexistent) to 10 (worst/unbearable) after EGD. Small-caliber EGD and C-EGD were performed with 5.9-mm and 9.8-mm video endoscopes (Olympus), respectively. RESULTS: The patients' age, sex, experience with EGD, and anxiety before EGD did not differ significantly between the three groups, each consisting of 50 patients. TSC-EGD failed in four of the 50 patients (8 %) because of a narrow nasal tract; they underwent PSC-EGD. Complete examinations, including the second part of the duodenum and biopsy sampling, were possible in all patients. Patients examined with an ultrathin instrument required sedation significantly less often (TSC-EGD 6 %, PSC-EGD 18 %, C-EGD 44 %; P < 0.01) and consequently spent less time in the recovery room. TSC-EGD was initially more painful on insertion, but caused less gagging (P<0.01) than peroral EGD during the whole procedure. TSC-EGD caused mild epistaxis in one case. CONCLUSIONS: TSC-EGD was carried out safely and completely in 92 % of the patients. TSC-EGD and PSC-EGD were better tolerated and required sedation less often than conventional EGD. Transnasal diagnostic EGD appears to be a promising alternative to peroral EGD, as it is associated with less gagging and a high level of patient satisfaction.

Adult↗

Eyes wide shut.

Explore the source record for details and available documents.

Digestive System Neoplasms↗

PillCam ESO in esophageal studies: improved diagnostic yield of 14 frames per second (fps) compared with 4 fps.

BACKGROUND AND STUDY AIM: Capsule endoscopy, using the PillCam ESO and sending images at a rate of 4 frames per second (fps), has a high sensitivity and specificity in diagnosing gastroesophageal reflux disease (GERD) lesions. We tested a new device which produces images at a rate of 14 fps. The diagnostic performance and esophageal visualization of these two devices were compared. PATIENTS AND METHODS: 42 patients with GERD symptoms and eight patients with a history of Barrett's esophagus had an esophagogastroduodenoscopy (EGD). All patients underwent capsule endoscopy of the esophagus within 1 hour prior to EGD. The first 25 patients had a capsule endoscopy examination with the 4-fps device. The following 25 patients underwent capsule endoscopy under identical conditions but using the 14-fps device. The reader of the capsule endoscopy study was blinded to the EGD findings. A diagnosis of GERD or Barrett's esophagus was established with EGD. The findings at capsule endoscopy were compared with the EGD findings. We also examined how frequently the esophagus in its entirety was visualized by these two devices. RESULTS: The 4-fps device diagnosed 16/19 cases of esophageal erosions or ulcers (sensitivity 84 %) and 6/8 cases of Barrett's esophagus (sensitivity 75 %). The 14-fps capsule diagnosed 16/16 cases of esophageal ulcers or erosions and 7/7 cases of Barrett's esophagus (sensitivity 100 %). The total diagnostic miss rate in the 4-fps group was 5/27 (18 %) whereas the diagnostic miss rate in the 14-fps group was 0/23 (0 %) P < 0.02). The upper esophageal sphincter (UES) was clearly identified in 6/25 patients (24 %) in the 4-fps group and in 20/25 patients (80 %) in the 14-fps group ( P < 0.01). The entire esophagus was well visualized in 3/25 patients (12 %) by the 4-fps device and in 19/25 (76 %) by the 14-fps device ( P < 0.01). The superiority of the 14-fps PillCam ESO capsule is consistent with the data obtained from fluoroscopic studies of swallowed PillCam capsules, showing that capsule speed may reach 20 cm/s. For the 14-fps PillCam this means one image transmitted per 3-cm segment at maximal capsule speed, therefore still allowing for full visualization of the entire esophagus. CONCLUSIONS: Capsule endoscopy using the 14-fps PillCam ESO showed a greater sensitivity than that of the 4-fps device for identifying GERD. The 14-fps PillCam ESO was statistically superior to the 4-fps device in visualizing the opening of the UES and the entirety of the esophagus.

Endoscopes, Gastrointestinal↗

Outcome of capsule endoscopy in determining indication and route for push-and-pull enteroscopy.

BACKGROUND AND STUDY AIM: Video capsule endoscopy and push-and-pull enteroscopy (PPE), both allow a complete examination of the small bowel in patients with suspected intestinal disorders. Due to the invasiveness of PPE, indications should probably be selective. The aim of the present prospective study was to evaluate the outcome of an approach whereby capsule endoscopy was used to select patients in whom PPE was indicated. PATIENTS AND METHODS: 164 patients were included (90 men; age 54+/-18 years) with various indications for small-bowel investigation, such as obscure bleeding (n=88), suspected Crohn's (n=14) or celiac (n=12) disease, or known or strongly suspected localized diseases such as neoplasms (n = 18) for biopsy. Four patients with a suspected intestinal stenosis underwent PPE without prior capsule endoscopy. In the remaining 160 patients, who had a capsule endoscopy, PPE was selected if there were lesions requiring biopsy or angiodysplasias to be treated by argon plasma coagulation (APC). Regarding the insertion route, an anal PPE was indicated if the capsule transit time from ingestion to arrival at the lesion was >or= 75 % of the total time from ingestion to arrival at the cecum. After gut cleansing, PPE was performed with general anesthesia, and the small bowel was examined until the lesion was reached or the scope could not be advanced further. If the suspected lesion had not been reached, a second procedure was performed through the alternative route, under the same conditions. RESULTS: The diagnostic yield of capsule endoscopy was 75 %. According to the indications, 47 PPE procedures were performed in 42 patients, including 33 through the oral route, 4 through the anal route and 5 combined ones. Indications were: suspicion of intestinal tumor (n=13), celiac disease with chronic bleeding (n=4), suspicion of Crohn's disease (n=3), treatment of significant arteriovenous malformations (AVMs) (n=10), diffuse enteropathies (n=3), nonsteroidal anti-inflammatory drug (NSAID)-related conditions (n=2), and obscure digestive bleeding (n=3). Lesions detected by capsule endoscopy were reached by PPE in all but two cases. The positive predictive value (PPV) of capsule endoscopy to make a correct indication for PPE was 94.7 % and the negative predictive value (NPV) was 98.3 %. The PPV and NPV of a time index of > 0.75 to start via the anal route were 94.7 % and 96.7 %. No complications were observed and all patients were discharged the day after the procedure. Follow-up at 9 months showed that capsule endoscopy followed by PPE had positively influenced the management of 90.5 % of the patients. CONCLUSIONS: The use of capsule endoscopy as a filter for PPE results in effective management of patients with various intestinal diseases. Capsule endoscopy can also direct the choice of route of PPE; a time index of > 0.75 appears to reliably indicate an anal route so that a double procedure is required in only about 12 % of cases.

Adult↗

The accuracy of PillCam ESO capsule endoscopy versus conventional upper endoscopy for the diagnosis of esophageal varices: a prospective three-center pilot study.

BACKGROUND AND STUDY AIMS: Variceal bleeding is a major complication of cirrhosis, and is associated with a 20 % mortality at 6 weeks. Current international guidelines recommend that patients with cirrhosis are screened by conventional upper endoscopy (esophagogastroduodenoscopy, EGD) in order to detect esophageal varices. The recently developed PillCam ESO esophageal capsule endoscope has been shown to be an accurate diagnostic tool in the investigation of patients with gastroesophageal reflux and Barrett's esophagus. We compared the PillCam ESO capsule endoscope with EGD for the detection of esophagogastric varices and portal hypertensive gastropathy in patients with cirrhosis. PATIENTS AND METHODS: A pilot trial was conducted at three sites. Patients with cirrhosis who were undergoing clinically indicated EGD for screening or surveillance for esophageal varices underwent a PillCam ESO study followed by an EGD within 48 hours. Capsule videos were assessed by an investigator who was blinded to the patient's medical history and EGD findings. RESULTS: A total of 23 of the 32 enrolled patients were found to have esophageal varices at both EGD and PillCam ESO endoscopy. In one patient PillCam ESO detected small varices that were not seen at EGD. The overall concordance between PillCam ESO and EGD was 96.9 % for the diagnosis of esophageal varices and 90.6 % for the diagnosis of portal hypertensive gastropathy. There were no adverse events related to PillCam ESO endoscopy. CONCLUSIONS: In a high-prevalence population, PillCam ESO may represent an accurate noninvasive alternative to EGD for the detection of esophageal varices and portal hypertensive gastropathy. A large-scale trial is underway to validate and expand these findings.

Endoscopes, Gastrointestinal↗