PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Films”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Thin casein films as prepared by spin-coating: influence of film thickness and of pH.

Casein films were successfully prepared with the spin-coating technique of aqueous casein solutions on base-treated glass surfaces. The film structure is investigated in real space with optical microscopy and atomic force microscopy and for the first time in reciprocal space with grazing incidence small-angle X-ray scattering (GISAXS). The size of the substructures detected in the film increases with pH from 170 nm (pH 5.1) up to 490 nm (pH 9.4). Dynamic light scattering experiments reveal that the average diameters of casein micelles in solution exhibit the same quantitative increase. This result suggests that the substructures detected in the bulklike films with GISAXS reflect intact casein micelles. However, with thin homogeneous casein films, the micelle size diminishes with decreasing film thickness. This indicates that the moderate pressures introduced by spin-coating force the micelles to rearrange into a more compact structure.

Caseins↗

Arabinoxylan-lipid-based edible films and coatings. 3. Influence of drying temperature on film structure and functional properties.

This work is a contribution to better knowledge of the influence of the structure of films obtained from emulsions based on arabinoxylans, hydrogenated palm kernel oil, and emulsifiers on their functional properties. The sucrose esters (emulsifiers) have a great effect on the stabilization of the emulsified film structure containing arabinoxylans and hydrogenated palm kernel oil. The structure and stability of the emulsion during drying strongly affect barrier and mechanical properties of films. The higher are creaming and coalescence phenomena in films, the lower is the water vapor permeability. Emulsion destabilization is favored by high drying temperature and tends to give films having a "bilayer-like" structure, which tends to improve the functional properties of arabinoxylans-based edible films.

Chemical Phenomena↗

Determination of anisotropic optical constants and surface coverage of molecular films using polarized visible ATR spectroscopy. Application to adsorbed cytochrome c films.

This article describes a method to determine the anisotropic optical constants and surface coverage of molecular films using polarized attenuated total reflectance (ATR) absorbance measurements. We have extended the transfer-matrix formalism to describe birefringent and dichroic films in ATR geometries and have combined it with an iterative numerical procedure to determine the anisotropic values of both the real (n) and imaginary (k) parts of the complex refractive index of the film under investigation. Anisotropic values of the imaginary part of the refractive index (k) allow for the determination of the surface coverage and one order parameter of the film. To illustrate this approach, we have used cytochrome c (cyt c) protein films adsorbed to glass and indium tin oxide (ITO) surfaces. Experimental results show that cyt c films on these surfaces, which were formed under identical conditions, have significant differences in their surface coverages (11.2 +/- 0.4 pmol/cm(2) on glass and 21.7 +/- 0.9 pmol/cm(2) on ITO); however, their order parameters are similar (0.30 +/- 0.02 on glass and 0.36 +/- 0.04 on ITO).

Adsorption↗

Moisture absorption and absorption kinetics in polyelectrolyte films: influence of film thickness.

Specular X-ray reflectivity (XR) and quartz crystal microbalance (QCM) measurements were used to determine the absorption of water into thin poly(4-ammonium styrenesulfonic acid) films from saturated vapor at 25 degrees C. The effect of film thickness on the absorption kinetics and overall absorption was investigated in the range of thickness from (3 to 200) nm. The equilibrium swelling of all the films irrespective of film thickness was (0.57+/-0.03) volume fraction. Although the equilibrium absorption is independent ofthickness, the absorption rate substantially decreases for film thickness < 100 nm. For the thinnest film (3 nm), there is a 5 orders of magnitude decrease in the diffusion coefficient for water.

Journal Article↗

Electron beam irradiation of poly(vinyl methyl ether) films: 1. Synthesis and film topography.

Temperature-sensitive hydrogel layers on silicon (Si) substrates were synthesized by electron beam irradiation of spin-coated poly(vinyl methyl ether) (PVME) films. The influences of the used solvent, the polymer concentration, and the spinning velocity on the homogeneity and the thickness of the PVME film were investigated. In the range of concentration c(p) = 1-15 wt% PVME in ethanol solution, homogeneous films with a thickness between d = 50 nm and 1.7 mum were obtained. The films were cross-linked by electron beam irradiation under inert atmosphere and analyzed by sol-gel-analysis. The results were compared with bulkgels formed by electron beam irradiation of PVME in the dry state. The film topography was analyzed by high-resolution field emission scanning electron microscopy and atomic force microscopy. An islandlike structure in the dry, swollen, and shrunken state of the hydrogel films was observed.

Journal Article↗

Photoactive additives for cross-linking polymer films: Inhibition of dewetting in thin polymer films.

In this report, we describe a versatile photochemical method for cross-linking polymer films and demonstrate that this method can be used to inhibit thin polymer films from dewetting. A bifunctional photoactive molecule featuring two benzophenone chromophores capable of abstracting hydrogen atoms from various donors, including C-H groups, is mixed into PS films. Upon exposure to UV light, the bis-benzophenone molecule cross-links the chains presumably by hydrogen abstraction followed by radical recombination. Photoinduced cross-linking is characterized by infrared spectroscopy and gel permeation chromatography. Optical and atomic force microscopy images show that photocrosslinked polystyrene (PS) thin films resist dewetting when heated above the glass transition temperature or exposed to solvent vapor. PS films are inhibited from dewetting on both solid and liquid substrates. The effectiveness of the method to inhibit dewetting is studied as a function of the ratio of cross-linker to macromolecule, duration of exposure to UV light, film thickness, the driving force for dewetting, and the thermodynamic nature of the substrate.

Cross-Linking Reagents↗

Adhesion of particulate specimens to support films for electron microscopy: a model system for assessing the surface properties of support films, and its application to chromatin particles.

Silica microspheres bearing a known surface charge were used to test the adhesive properties of support films and support film treatments commonly used in the electron microscopy of particulate specimens. Adhesion was strongly correlated with surface charge, negatively charged microspheres binding well only to positively charged support films and vice versa in solutions of low ionic strength. This charge dependency could be overcome by increasing the ionic strength to about 100 mmol with monovalent cations; under these conditions, it was not necessary to provide an oppositely charged film surface to obtain adhesion. Chromatin particles (nucleosomes) which have a net negative charge, behaved very much like the negatively charged silica with respect to adhesion, confirming that the microspheres provided an accurate indication of support film surface properties. The chromatin particles showed dramatic structural changes under conditions when adhesion was either poor, or very strong, indicating the need for careful selection of binding conditions for delicate biological specimens. A new and simple method for pretreating carbon films to improve adhesion was developed, and a preliminary account of this technique is presented.

Carbon↗

Phantom evaluation of the effect of film processing on mammographic screen-film combinations.

Mammographic image quality should be optimal for diagnosis, and the film contrast can be manipulated by altering development parameters. In this study phantom test objects were radiographed and processed for a given range of developer temperatures and times for four film-screen systems. Radiologists scored the phantom test objects on the resultant films to evaluate the effect on diagnosis of varying image contrast. While for three film-screen systems processing led to appreciable contrast differences, for only one film system did maximum contrast correspond with optimal phantom test object scoring. The inability to show an effect on diagnosis in all cases is possibly due to the variation in radiologist responses found in this study and in normal clinical circumstances. Other technical factors such as changes in film fog, grain and mottle may contribute to the study findings.

Mammography↗

Theory of elastic wave propagation in anisotropic film on anisotropic substrate: TiN film on single-crystal Si.

The delta-function representation of the elastodynamic Green's function is used to derive an expression for the elastic wave forms on the surface of an anisotropic thin film on an anisotropic substrate due to a point or a line source located at the surface of the film. The dispersion relation for surface acoustic waves (SAWs) is obtained from the poles of the Green's function. A computationally efficient algorithm is formulated to obtain the elastic constants and the density of the film from the SAW dispersion data. The theory is used to analyze measured SAW dispersion relations in a titanium nitride film on silicon. The analysis yields values of the elastic constants and the density of the film. Excellent agreement is obtained between the theoretical and experimental dispersion results. Calculated wave forms for the surface wave due to a pulsed line source on the surface of the film are reported.

Journal Article↗

A novel approach in the assessment of polymeric film formation and film adhesion on different pharmaceutical solid substrates.

The purpose of this study was to evaluate the nature of film formation on tablets with different compositions, using confocal laser scanning microscopy (CLSM), and to measure film adhesion via the application of a novel "magnet probe test." Three excipients, microcrystalline cellulose (MCC), spray-dried lactose monohydrate, and dibasic calcium phosphate dihydrate, were individually blended with 0.5% magnesium stearate, as a lubricant, and 2.5% tetracycline HCl, as a fluorescent marker, and were compressed using a Carver press. Tablets were coated with a solution consisting of 7% hydroxypropyl methylcellulose (HPMC) phthalate (HP-55), and 0.5% cetyl alcohol in acetone and isopropanol (11:9). The nature of polymer interaction with the tablets and coating was evaluated using CLSM and a designed magnet probe test. CLSM images clearly showed coating efficiency, thickness, and uniformity of film formation, and the extent of drug migration into the film at the coating interfaces of tablets. Among the excipients, MCC demonstrated the best interface for both film formation and uniformity in thickness relative to lactose monohydrate and dibasic calcium phosphate dihydrate. The detachment force of the coating layers from the tablet surfaces, as measured with the developed magnet probe test, was in the order of MCC>lactose monohydrate>dibasic calcium phosphate dihydrate. It was also shown that the designed magnet probe test provides reliable and reproducible results when used for measurement of film adhesion and bonding strength.

Adhesiveness↗

Convenient procedures for human hair protein films and properties of alkaline phosphatase incorporated in the film.

We have developed a novel method of extracting proteins from human hair in the absence of detergent called the "Shindai Method". Using the protein solution consisting of hard alpha-keratins and matrix proteins prepared by this method, we developed two procedures for preparing hair protein films. The protein solution was mixed with trichloroacetic acid (TCA), perchloric acid (PCA) or guanidine-HCl (GHA), and then exposed in distilled water. Light brown aggregates immediately formed (Pre-cast method). The other method is based on the same characteristics of the hair proteins to form protein aggregates. The protein was directly exposed to the solution containing TCA, PCA, GHA, HCl, H(2)SO(4) or acetate buffer (Post-cast method). The maximum yield was greater than 70%. These protein films were water-insoluble and mainly made up of alpha-keratins. Scanning electron micrographs showed that the fine surface of the protein films was composed of particles, filaments, and porous structures and the constitution was dependent on the preparation procedure used. When porcine intestine alkaline phosphatase (ALP) was mixed with the hair protein solution in a Post-cast method using acetate buffer (pH 5), ALP was incorporated into the alpha-keratin films. The activity retained in the protein film was approximately 8% of the original level. The biochemical properties of the ALP activity in the film were similar to those of the native enzyme.

Alkaline Phosphatase↗

Substrate temperature effect on the refractive index and a two-step film method to detect small inhomogeneities in optical films.

Nb2O5 films were deposited by a reactive magnetron sputtering technique. The average refractive index was found to increase with the rise of substrate temperature. Modulated interference transmittance spectra were observed in the two-step films, which were prepared by stopping the deposition process in the middle of the designed sputtering time, and then, after a full cooling down to room temperature, starting the same deposition process again to complete the whole preparation of the films. A linearly graded-index model was used to explain the interference behavior. It was proved that the two-step film method was sensitive to the small inhomogeneity in the films. We also suggest that the inhomogeneity of sputtered films can be minimized by controlling the substrate temperature at a constant value.

Journal Article↗

[Photoluminescence from Er-doped silicon-rich silicon oxide film and Er-doped silicon-rich silicon nitride film and its annealing behavior].

Room temperature photoluminescence (PL) with a peak at 1.54 microns was observed from silicon oxide, silicon-rich silicon oxide, silicon nitride and silicon-rich silicon nitride films, all doped with Er and grown by the magnetron sputtering technique. To determine the optimum annealing temperature for the 1.54 microns PL, these films were annealed in the range of 600-1,100 degrees C with an interval of 100 degrees C. Among these four types of films annealed at an identical temperature, the intensity of 1.54 microns PL peak of the Er-doped silicon-rich silicon oxide film was always the strongest one, which arrived at a maximum in 800 degrees C annealing. A 1.38 microns PL band was also observed in each of these four types of films, and which in the silicon-rich silicon oxide or silicon-rich silicon nitride films was found to be correlated with the 1.54 microns PL band in intensity.

Chemical Phenomena↗

An evaluation of Ektaspeed Plus film versus Ultraspeed film for endodontic working length determination.

Thirteen teeth in human cadaver sections were accessed and #15 K-files were placed at various lengths in one root canal of each tooth. Using a positioner to ensure duplicate views, radiographs were taken with both Ultraspeed and Ektaspeed Plus X-ray film. Each of the 26 radiographs was coded and then placed in random order. Six endodontic specialists measured the distance from the file tip to the radiographic apex on each film. The results were analyzed by analysis of variance and Cronbach's generalizability theory. It was found that 94% of the variance in measurements was due to differences among the viewers, whereas 5% was due to a combination of viewers and tooth. Only 1% was due to differences between the two types of film. It was concluded that Ektaspeed Plus film may be used for working length radiographs because it requires only approximately 50% of the radiation needed for Ultraspeed film.

Analysis of Variance↗

Clinical assessment of dry laser-processed film versus traditional wet-processed film with computed tomography, magnetic resonance imaging, and ultrasound.

RATIONALE AND OBJECTIVES: To compare image quality and diagnostic performance (by using receiver operating characteristic techniques) for laser imaging film from two systems: a traditional wet system that uses chemical processing and a new dry system that is wet-chemistry-free. METHODS: For three separate studies (computed tomography, magnetic resonance imaging, and ultrasound), identical images for 40 cases were printed on both the wet and dry imaging systems. Ten radiologists participated in each study, giving a decision confidence rating for lesion present or absent and evaluating image quality. RESULTS: In all three studies, there were no statistically significant differences in diagnostic performance when reading images that had been wet processed versus those that had been dry processed. Image quality was comparable for wet-and dry-processed films for all three modalities. CONCLUSION: Dry laser processing produces high-quality radiologic films that are comparable to those currently produced by using wet laser processing. Dry-processed film represents a useful alternative to wet-processed film.

Lasers↗

Assessment of radiographic screen-film systems: a comparison between the use of a microdensitometer and a drum film digitiser.

A high-end drum film digitiser (Tango, Germany) and a calibrated linear microdensitometer developed by PTB were used to assess the modulation transfer function (MTF) and the noise power spectra (NPS) of 3 mammographic screen film systems at optical density levels of 0.8, 1.5 and 2.5. The use of a drum scanner to assess MTF and NPS data appears to be adequate but requires an appropriate characterisation of the scanner to verify its internal noise level and its MTF. It is further necessary to calibrate the scanner output in terms of visual diffuse optical densities. Processing of two-dimensional digital data of grating images need to be more strictly defined for accurate MTF measurements of screen-film systems. Nevertheless, even now it seems to be feasible to use commercially available high-end and well calibrated scanners to assess screen film systems. This is especially important for quality assurance purposes because important parameters of screen film systems such like MTF and NPS can now be determined without using sophisticated microdensitometers which are not commercially available.

Calibration↗

A comparison of two different T-grain films in rare-earth screens with a standard film-screen combination for intravenous pyelography and bone examinations.

T-grain film is claimed to give significantly improved image quality, allowing the use of faster screens without loss of quality and thus reducing radiation dose. We tested this claim for two systems. In each case comparison was made with our usual screen-film combination, Agfa Curix RP1 film with Kodak Xomatic Regular screens (a nominally 200 speed system). The systems tested were Kodak TMatG in Kodak Lanex Medium screens (300 speed) and Agfa STG in Kodak Lanex Regular screens (400 speed). The Agfa STG-Lanex Regular system performed less well than the standard system for intravenous pyelograms (IVPs), bones and soft-tissue detail. Its speed advantage was not apparent below 70 kV. The Kodak TMatG-Lanex Medium system was better than the standard system for IVPs but not as good for bones. It gave virtually no speed advantage below 90 kV. Kodak T-grain film in a medium-speed, rare-earth screen was found to be better than the standard system for IVPs. Agfa T-grain film in a fast rare-earth screen was unsatisfactory for IVPs. Neither combination was as good as the standard system for bones.

Bone and Bones↗

Comparison of an asymmetric screen-film combination with a conventional screen-film combination for chest radiography in 51 patients.

Comparison is made between a new asymmetric screen-film combination and a conventional screen-film combination for use in chest radiography. Seven anatomical features were assessed by three consultant radiologists in each of 51 film pairs. A preference was indicated if one system better demonstrated a particular feature. Alternatively, no preference was indicated if the feature was equally demonstrated by both systems or not demonstrated at all. Any pathology incidentally noted which remained unchanged between the two films was localized to lung, mediastinum or bone and marked in the same way. The asymmetric high contrast system scored higher than the conventional system for demonstration of anatomy in both mediastinum and lungs, but no difference emerged between the two systems in the demonstration of pathology. The asymmetric screen-film system showed improved mediastinal and, to a lesser degree, improved lung detail. Further assessment in necessary to define any associated improvement in diagnostic yield.

Decision Making↗