Purification and characterization of a biosurfactant produced by Pseudomonas sp. G11 by asymmetrical flow field-flow fractionation (AsFlFFF).

Three hundred and thirty two bacterial colonies were isolated from soil contaminated by an oil spill. All the bacteria were cultured in a liquid medium individually, and the surface tensions of the media were compared. The bacterium whose culture medium had the lowest surface tension was identified as Pseudomonas sp. G11. A biosurfactant was produced by cultivation of the Pseudomonas sp. G11 in the LB media. For extraction of the biosurfactant, two solvent systems were used (n-hexane and a 2:1 (v/v) mixture of chloroform/MeOH), and the results were compared. Various experimental conditions (solvent composition, flow rate, etc.) were tested to optimize the analysis of the biosurfactant by asymmetrical flow field-flow fractionation (AsFlFFF). The biosurfactant was successfully separated from the culture medium by AsFlFFF when pure water was used as the carrier. From the retention data, the hydrodynamic diameter (dH) and molecular weight (M) of the biosurfactant were determined by AsFlFFF. The molecular weight was determined by using pullulans as the calibration standards. The dH and M were 49 nm and 2.3 x 10(5) Da when extracted with n-hexane, and 39 nm and 1.13 x 10(5) Da when extracted with the 2:1 mixture of chloroform/MeOH, respectively.

Calibration↗

Sedimentation Field-Flow Fractionation of Nonspherical Particles

Sedimentation field-flow fractionation (SdFFF) has proved to be a very powerful technique for the particle size analysis of submicrometer hydrosols. Recently reports have been published on the analysis of coagulated latex samples via SdFFF. In these investigations the coagulated particles do not behave as predicted by SdFFF theory but elute from the SdFFF channel more rapidly than expected. This behavior has been ascribed to the effect of particle shape on retention. In this investigation samples of monodisperse polystyrene latices were coagulated under shear to yield particles which were all alike in shape (rod-like). Analyzing these samples via SdFFF indicated that retention is determined by the maximum dimension of the particle rather than by any average size. For highly retained particles there was an additional effect acting to shorten the expected retention time due to the tumbling motion of the rod-like particles in the shear flow through the SdFFF channel.

Journal Article↗

A microfabricated thermal field-flow fractionation system.

A microscale thermal field-flow fractionation (micro-TFFF) system has been designed, fabricated, and characterized. Motivation for miniaturization of TFFF systems was established by examining the geometrical scaling of the fundamental TFFF theory. Miniaturization of conventional macroscale TFFF systems was made possible through utilization of micromachining technologies. Fabrication of the micro-TFFF system was discussed in detail. The micro-TFFF system was characterized for plate height versus flow rate, single-component polystyrene retention, and multicomponent polystyrene separations. Retention, thermal diffusion coefficients, and maximum diameter-based selectivity values were extracted from separation data and found comparable with macroscale TFFF system results. Retention values ranged from 0.33 to 0.46. Thermal diffusion coefficients were between 3.0 x 10(-8) and 5.4 x 10(-8) cm2/s x K. The maximum diameter-based selectivity was 1.40.

Journal Article↗

Characterization of a microscale cyclical electrical field flow fractionation system.

A microscale cyclical electrical field flow fractionation (CyElFFF) channel is characterized with regard to the effect of various operating parameters and comparison made to recent theoretical developments. Challenges associated with various operating conditions are reported along with some of the optimized operating parameters. The effect of retention wall choice, an offset voltage, relaxation steps, and flow rates, along with the basic operating parameters of voltage, frequency, and electrophoretic mobility are reported. Retention of polystyrene nanoparticle standards is accomplished and the first separations using this technique in a microscale system are also demonstrated. Relaxation steps and offset voltages are found to be effective in eliminating early peaks and in improving plate heights. Plate heights were also found to decrease with increasing flow rates, which is the opposite of the behavior seen in most existing chromatographic systems. The experimental results are compared to the analytical and empirical models of CyElFFF and found to be compatible. Suggestions are made for improving the separation and analysis methods used with CyElFFF.

Journal Article↗

Improved accuracy in the determination of field-flow fractionation elution volumes.

Conventional operation of field-flow fractionation (FFF) systems involves carrying out the analysis at a constant flow of carrier; the flow is temporarily interrupted after injection of a sample in order to permit its equilibration under the applied field. Retention is calculated as the ratio of elution times for a non-retained species and the sample of interest, respectively. Such time-based retentions are only valid if the flow-rate is precisely known at all times during the run. The peristaltic pumps often used with FFF equipment are shown to have an output which varies unpredictably in time. Furthermore, initiation of flow after relaxation is shown to result in significant periods of transient behaviour while the system adjusts to the operating pressure. These and other variations in flow-rate can be eliminated as sources of error by basing the retention measurement on effluent weight, rather than on time. For this purpose, an electronic balance is interfaced with the system's computer, so that detector response/effluent weight data pairs are continuously monitored during the course of the FFF analysis.

Chemical Fractionation↗

Characterization of natural organic matter fractions separated by ultrafiltration using flow field-flow fractionation.

Natural organic matter (NOM) from two sites in South Australia were separated by Amicon YM and YC ultrafiltration (UF) membranes into five nominal fractions (<0.5, 0.5-3, 3-10, 10-30 and >30 kDa). These nominal fractions were then characterized for size and molecular weight (MW) distributions using flow field-flow fractionation. The results show that separation by UF did not produce fractions with the expected MW and size. Electrophoretic mobility measurements of the NOM fractions adsorbed to colloidal goethite showed no significant difference between the fractions. However solid-state (13)C NMR of the NOM fractions showed that the separation was influenced by molecular structure as well as molecular size. The results suggest that great caution needs to be exercised when interpreting molecular size and speciation results for humic substances obtained by membrane UF.

Adsorption↗

Separation of polystyrene microbeads using dielectrophoretic/gravitational field-flow-fractionation.

The characterization of a dielectrophoretic/gravitational field-flow-fractionation (DEP/G-FFF) system using model polystyrene (PS) microbeads is presented. Separations of PS beads of different surface functionalization (COOH and none) and different sizes (6, 10, and 15 microm in diameter) are demonstrated. To investigate the factors influencing separation performance, particle elution times were determined as a function of particle suspension conductivity, fluid flow rate, and applied field frequency and voltage. Experimental data were analyzed using a previously reported theoretical model and good agreement between theory and experiment was found. It was shown that separation of PS beads was based on the differences in their effective dielectric properties. Particles possessing different dielectric properties were positioned at different heights in a fluid-flow profile in a thin chamber by the balance of DEP and gravitational forces, transported at different velocities under the influence of the fluid flow, and thereby separated. To explore hydrodynamic (HD) lift effects, velocities of PS beads were determined as a function of fluid flow rate in the separation chamber when no DEP field was applied. In this case, particle equilibrium height positions were governed solely by the balance of HD lift and gravitational forces. It was concluded that under the experimental conditions reported here, the DEP force was the dominant factor in controlling particle equilibrium height and that HD lift force played little role in DEP/G-FFF operation. Finally, the influence of various experimental parameters on separation performance was discussed for the optimization of DEP/G-FFF.

Electrophoresis↗

Reduction of end effect-induced zone broadening in field-flow fractionation channels.

A channel configuration for the elimination of end effects in field-flow fractionation (FFF) channels is simulated and demonstrated for a microfabricated FFF system. In field-flow fractionation, the carrier liquid and sample particles are transferred from a point injection to the full breadth of the rectangular channel using a triangular end piece at the inlet. The nonuniformity in streamline length generated by this end piece results in an increased instrument-related plate height. An additional contribution from the end piece at the outlet of the channel further increases the total band broadening. This paper presents a novel approach to minimize end-effect contributions to plate height by fabricating microstructures in the channel end sections to redistribute the flow streams and force streamline lengths to be more uniform. Numerical analysis of the flow profile and sample dispersion (including spreading of particles due to diffusion and advection) is carried out to investigate the optimized microstructure column size, shape, and placement in the end pieces. The configuration obtained from the numerical simulation results is used to design a prototype device. Experimental measurement of the plate heights for this prototype with an on-chip impedance-based detector shows marked improvement in performance due to the presence of the microstructures in comparison to conventional FFF channel geometry with an average 50% reduction in plate height. The redesigned inlet triangle results in a uniform transition of the point-injected sample into a thin and straight band across the width of the channel at the start of the rectangular section of the fractionation channel.

Fractionation, Field Flow↗

A critical review of analytical ultracentrifugation and field flow fractionation methods for measuring protein aggregation.

Analytical ultracentrifugation (AUC) and field flow fractionation (FFF) are 2 important biophysical methods for measuring protein aggregates. Both methods can separate protein monomer from its aggregate forms under a broad range of solution conditions. Recent advances in instrumentation and data analysis, particularly in the field of analytical ultracentrifugation technology, have significantly improved the capability and sensitivity of these biophysical methods for detecting protein aggregates. These advances have resulted in an increased use of these methods in the biopharmaceutical industry for characterization of therapeutic proteins. However, despite their many advantages over conventional methods, the difficulty in the use of the instrumentation and the complexity of data analysis process, have often hampered the widespread use and proper interpretation of data. This article reviews the recent progress in both technologies, and a few case studies are also presented to discuss their advantages and limitations.

Biological Products↗

Adsorption behavior of milk proteins on polystyrene latex. A study based on sedimentation field-flow fractionation and dynamic light scattering.

Sedimentation field-flow fractionation (SdFFF) has been used to characterize the adsorption of the proteins beta-casein (BCN) or beta-lactoglobulin (BLG) on colloidal polystyrene latices; this system was used to model hydrophobic interactions between the proteins and the surfaces of fat droplets in protein-stabilized emulsions. It was found that the SdFFF technique could determine directly the surface concentrations of BCN and BLG irreversibly adsorbed to the latex surface, provided care was taken to maintain the ionic strength of the carrier at a level which suppressed particle-wall repulsion in the separation channel. The measured surface concentrations were similar for the two proteins (about 1 mg/m2), and this was verified by quantitative amino acid analysis. These concentrations were smaller than those found in depletion studies (3 and 4 mg/m2 respectively for BCN and BLG), in which loosely associated protein may have been included in the determinations. The thickness of the adsorbed layers was determined in situ by dynamic light scattering and was found to differ significantly for the two proteins (up to 15 nm for BCN vs. 2-3 nm for BLG). The implication of these findings in terms of different surface arrangements of the two proteins is discussed.

Calorimetry↗

Cortical cell elution by sedimentation field-flow fractionation.

As a cell sorter, Sedimentation field-flow fractionation (SdFFF) can be defined as an effective tool for cell separation and purification, respecting integrity and viability as well as providing enhanced recovery and purified sterile fraction collection. The complex cell suspension containing both neurons and glial cells of all types, obtained from cerebral cortices of 17-day-old rat fetuses, is routinely used as a model of primary neuronal culture. Using SdFFF, this complex cell mixture was eluted in sterile fractions which were collected and cultured. SdFFF cell elution was conducted under strictly defined conditions: rapid cell elution, high recovery (negligible cell trapping), short- and long-term cell viability, sterile collection. After immunological cellular type characterization (neurons and glial cells) of cultured cells, our results demonstrated the effectiveness of SdFFF to provide, in less than 6 min, viable and enriched neurons which can be cultured for further investigations.

Animals↗

Validation procedures of sedimentation field-flow fractionation techniques for biological applications.

Sedimentation field-flow fractionation (SdFFF) offers great potential for the separation of submicrometer and micrometer-sized species. The availability of commercial instrumentation and the versatility of this method originated its success. At this stage of development, SdFFF techniques are mature enough for use in analytical research, development and even routine work. However, prior to their use, these techniques like any other methodologies, have to be validated. As the application of SdFFF techniques to cell separation is being constantly developed, we have investigated separation performance according to validation rules classically defined for separation methods (chromatography) in the case of cellular materials.

Blood Specimen Collection↗

Effect of carrier ionic strength in microscale cyclical electrical field-flow fractionation.

Recent work with cyclical electrical field-flow fractionation systems has shown promise for the technique as a separation and analysis tool, but little is understood about how the carrier composition in the system affects its capabilities. The electrical properties of microscale CyElFFF systems change when the carrier ionic conditions are altered, and it is well known that the effects of increasing ionic strength carriers on retention in normal ElFFF systems are severe. Specifically, retention levels fall significantly. Accordingly, this work seeks to understand the effect that increasing carrier ionic strength in CyElFFF has on nanoparticle retention in the channels. The retention of polystyrene particles in the CyElFFF microsystem is reported at various ionic strengths of ammonium carbonate and at a variety of pH levels. The experiments are compared to the theory of CyElFFF available in the literature. The results indicate that the ionic strength of the carrier has a significant impact on retention and that high ionic strength carrier solutions lead to poor performance of the CyElFFF system. These results have significant impact on the possible uses of the technique and its applications, especially in the biomedical arena.

Journal Article↗

Kinetic study of cell proliferation of Saccharomyces cerevisiae strains by sedimentation/steric field flow fractionation in situ.

The technique of Sedimentation/Steric Field Flow Fractionation (Sd/StFFF) is applied to the kinetic study of cells proliferation of Saccharomyces cerevisiae strains. The experimental parameter varied is the time from the preparation of the yeast sample dispersion in the culture medium. The determination of the size and mass distributions of the yeast cells is combined with the growth of the yeast cells and their life cycle. The experimental results are compared with those obtained by scanning electron microscopy (SEM) and those found in the literature. Useful conclusions concerning the budding and the fission of these yeast cells were extracted.

Algorithms↗

Measurements of size distribution and density of a pharmaceutical fat emulsion, using field-programmed sedimentation field-flow fractionation (SdFFF).

PURPOSE: The main goal was to establish that sedimentation field-flow fractionation (SdFFF), operated with power based field programming, is effective in the characterization of a commercial emulsion, Medialipide. This emulsion is used clinically for total parenteral nutrition and it is consisted of a mixture of long-chain triglycerides (LCT, soybean oil) with medium-chain triglycerides (MCT) emulsified by phospholipids. METHODS: Different field programming methods were used in the analysis to establish the limits of applicability of the technique. RESULTS: Identical size distribution profiles were obtained under various conditions of the analysis. The density of the droplets was determined by collecting fractions from the SdFFF eluting bands, and analyzing them by photon correlation spectroscopy. The value of density of the oil droplets was changed in the SdFFF data, until best agreement with the PCS values was achieved. The value of density corresponding to the best agreement was considered as the oil density, and it was closed to the weighted average value between soybean and MCT oils. CONCLUSIONS: Field programming extends the capabilities of sedimentation field-flow fractionation in handling and characterizing complex and delicate samples as Medialipide.

Centrifugation↗

Miniature field-flow fractionation system for analysis of blood cells.

Field-flow fractionation is an analytical tool that has been historically used to separate species, ranging from molecules to particles or cells several micrometers in size. This technology can effect separation by size, density, charge, or other physical properties, depending on the configuration of the field-flow system. We have developed a miniature field-flow system to analyze cell populations in a small, 125-microns-deep channel 19 cm long. Gravity is used as the primary field to effect separation, and cell analysis is performed in < 20 min. Erythrocytes elute as a single peak when diluted blood is fractionated in this system. Analysis of blood samples from several donors (normal controls and patients with sickle cell anemia) yields erythrocyte peaks with slightly different mobilities (elution times). Peak mobility does not directly correlate with mean cell volume or other standard erythrocyte parameters. Cell density appears to be a key factor in determining cell mobility with this system.

Cell Separation↗

Continuous two-dimensional field-flow fractionation: a novel technique for continuous separation and collection of macromolecules and particles.

Instrumental techniques to analyse macromolecular and particulate materials have undergone rapid development in response to the need for high resolution, precise identification and characterization, and enrichment and collection for further analysis. Continuous two-dimensional field-flow fractionation (2D-FFF), which is described in this article, is a novel technique for separation and collection of macromolecules and particles. 2D-FFF is based on the conventional field-flow fractionation principle but with carrier flow in two-dimensions. This overview discusses the principle of the technique, describes the instrumentation and suggests potential applications and further extensions. An overview of the basic field-flow fractionation principle is presented.

Chemical Fractionation↗

Improved performance of gravitational field-flow fractionation for screening wine-making yeast varieties.

Performance of gravitational field-flow fractionation (GFFF) is improved here with respect to the ability to fractionate and distinguish different varieties of wine-making yeast from Saccharomyces cerevisiae. A new GFFF channel with non-polar walls has been employed to enhance fractionation selectivity and reproducibility. Since GFFF retention depends from first principles on particle size, Coulter counter measurements were performed in order to compare size distribution profiles with GFFF profiles. From such a comparison, GFFF was shown to be able to reveal differences in yeast cells other than size. This could make use of GFFF for screening different varieties of wine-making yeast towards future quality assessment procedures based on a possible correlation between yeast cell morphology indexes and quality indexes.