PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “METHYLPARABEN”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Prediction of preservative sensitization potential using surface marker CD86 and/or CD54 expression on human cell line, THP-1.

Preservatives are important components in many products, but have a history of purported allergy. Several assays [e.g., guinea pig maximization test (GPMT), local lymph node assay (LLNA)] are used to evaluate allergy potential of preservatives. We recently developed the human Cell Line Activation Test (h-CLAT), an in vitro skin sensitization test using human THP-1 cells. This test evaluates the augmentation of CD86 and CD54 expression, which are key events in the sensitization process, as an indicator of allergy following treatment with test chemical. Earlier, we found that a sub-toxic concentration was needed for the up-regulation of surface marker expression. In this study, we further evaluate the capability of h-CLAT to predict allergy potential using eight preservatives. Cytotoxicity was determined using propidium iodide with flow cytometry analysis and five doses that produce a 95, 85, 75, 65, and 50% cell viability were selected. If a material did not have any cytotoxicity at the highest technical dose (HTD), five doses are set using serial 1.3 dilutions of the HTD. The test materials used were six known allergic preservatives (e.g., methylchloroisothiazolinone/methylisothiazolinone, formaldehyde), and two non-allergic preservatives (methylparaben and 4-hydroxybenzoic acid). All allergic preservatives augmented CD86 and/or CD54 expression, indicating h-CLAT correctly identified the allergens. No augmentation was observed with the non-allergic preservatives; also correctly identified by h-CLAT. In addition, we report two threshold concentrations that may be used to categorize skin sensitization potency like the LLNA estimated concentration that yield a three-fold stimulation (EC3) value. These corresponding values are the estimated concentration which gives a relative fluorescence intensity (RFI) = 150 for CD86 and an RFI = 200 for CD54. These data suggest that h-CLAT, using THP-1 cells, may be able to predict the allergy potential of preservatives and possibility classify the potency of an allergen.

Allergens↗

In vitro spermicidal activity of parabens against human spermatozoa.

Potent in vitro spermicidal activity of parabens against human spermatozoa was demonstrated in this study. The "pass" point concentration of the four parabens--methylparaben, ethylparaben, propylparaben, and butylparaben, at which all spermatozoa were immobilized and no immobilized spermatozoon revived after 30 min incubation in phosphate buffered glucose solution, was 6, 8, 3, and 1 mg/ml, respectively, as tested by Harris' method. These parabens are used as food and pharmaceutic preservatives; less toxicity and side effects were expected for the development of parabens as vaginal contraceptive agents.

Dose-Response Relationship, Drug↗

An unusual skin reaction following local anesthetic injection. Review of the literature and report of four cases.

Four cases of an unusual skin eruption related to mandibular block injection are presented. The authors suggest an immunologic basis for the reaction, probably to the methylparaben preseravtive, and discuss a possible pathogenic mechanism. The medical-dental literature concerning untoward reactions to lidocaine is reviewed; particular attention is given alleged allergic reactions.

Arthus Reaction↗

The toxicological implications of the interaction of butylated hydroxytoluene with other antioxidants and phenolic chemicals.

Butylated hydroxyanisole (BHA) enhanced both the in vitro peroxidase-catalysed covalent binding of butylated hydroxytoluene (BHT) to microsomal protein and the formation of BHT-quinone methide. Eugenol, methylparaben, vanillin, guaiacol, ferulic acid and several other phenolic compounds commonly used in food and cosmetic products also enhanced the metabolic activation of BHT. BHA was the most effective compound tested. Microsomes from lung, bladder, kidney medulla and small intestine of various animal species, including man, were also able to support this interaction of BHA and BHT using either hydrogen peroxide or arachidonic acid as the substrate. These in vitro observations were extended to an in vivo mouse lung model. Subcutaneous injections of BHA significantly enhanced the lung/body weight ratio of mice given intraperitoneal injections of subthreshold doses of BHT. The toxicological implications of the interactions of BHT with other antioxidants and phenolic chemicals and their potential relevance to human risk are discussed.

Animals↗

Determination in plasma of angiotensin-converting enzyme inhibitor by inhibitor-binding assay.

A method of determining a new angiotensin-converting enzyme inhibitor (CS-622) and its active metabolite (RS-5139) in plasma by inhibitor-binding assay has been developed using high-performance liquid chromatography. The assay is based on the principle that the amount of inhibitor bound to the enzyme is inversely related to the amount of hippuric acid liberated on hydrolysis from the artificial substrate (hippuryl-L-histidyl-L-leucine). Plasma was heated at 60 degrees C for 15 min, to inactivate endogenous enzyme, and preincubated with rabbit-lung angiotensin-converting enzyme at 37 degrees C for 3 min. The artificial substrate (5.75 mg/ml in pH 8.3 phosphate buffer containing sodium chloride) was added to the resulting solution, and the mixture was incubated for 30 min. The reaction was terminated by the addition of 2 M hydrochloric acid. The hippuric acid liberated on hydrolysis was extracted with ethyl acetate and determined by reversed-phase chromatography using methylparaben as an internal standard. The total concentration of the inhibitor and its metabolite were determined by this method after de-esterification by rat-plasma esterase. The standard curve was obtained by the regression analysis of log concentration against logit response. The within-day and day-to-day precision were satisfactory. The proposed method is simple, rapid and sensitive enough to determine angiotensin-converting enzyme inhibitor in plasma.

Angiotensin-Converting Enzyme Inhibitors↗

Effects-directed analysis of organic toxicants in wastewater effluent from Zagreb, Croatia.

The organic toxicants present in the effluent of the main sewer of the city of Zagreb, Croatia were isolated and identified through the use of effects-directed characterisation techniques. At the time of investigation, the wastewater effluent received no treatment and was comprised of a mixture of effluent from domestic and industrial sources. The organic load of the wastewater was isolated by solid phase extraction and toxicity profiles obtained using reverse-phase HPLC. All procedures were evaluated through the analysis of a series of reference compounds of widely differing polarity. Toxicity profiles for EROD activity (CYP1A induction), vitellogenin induction (estrogenic activity), cytotoxicity (membrane stability and metabolic inhibition) were obtained using a rainbow trout (Oncorhynchus mykiss) primary hepatocyte bioassay. The suite of bioassays showed biological responses after exposure to the raw extracts for all the endpoints tested. However, a combination of mixture toxicity and cytotoxicity in the complex raw extract had some masking effect on the sub-lethal responses of vitellogenin and EROD induction. Bioassay testing of the fine fractions obtained by HPLC produced a range of endpoint-specific toxicity profiles for each sample. A number of compounds were identified by the use of GC-MS and LC-MS/MS as responsible for the observed effects. The steroid estrogens 17 beta-estradiol and estriol were identified by LC-MS/MS as estrogen receptor agonists in two of the estrogenic fractions. In addition, GC-MS analysis identified different alkylphenols, benzophenone and methylparaben which also contributed to the estrogenic activity of the sample. Polycyclic aromatic hydrocarbons (PAHs), alkyl substituted PAHs, nitro-polycyclic aromatic compounds (nitro-PACs), carbazoles and alkyl substituted carbazoles and other known CYP1A inducers were identified by GC-MS analysis as responsible for some of the observed EROD activity. Some active compounds remain unidentified.

Animals↗

Comparison of equations describing band broadening in high-performance liquid chromatography.

Several models are well established that describe band broadening in gas and liquid chromatography, including those due to Van Deemter and Knox. Comparison of competing models is complicated if raw data are noisy or if the equations to be fitted to data contain many adjustable parameters. This paper describes a comparison of fitting the Van Deemter, Knox and other equations to low noise data gathered during the separation of propyl- and methylparaben by HPLC. Equations are compared using established statistical methods, including analysis of residuals, inference of parameter estimates and Akaikes Information Criterion for model identification. This work indicates that equations that account for non-linear band broadening at elevated mobile phase velocities are more successful at describing the relationship between height equivalent to a theoretical plate, H, and the velocity of the mobile phase, u.

Chromatography, High Pressure Liquid↗

Non-particulate (continuous bed or monolithic) acrylate-based capillary columns for reversed-phase liquid chromatography and electrochromatography.

Three approaches are described to synthesize acrylic non-particulate beds (also called continuous beds or monoliths) in aqueous polymerization media for reversed-phase capillary liquid chromatography/electrochromatography. In the first, hexyl acrylate comonomer was dissolved together with water soluble polar comonomers using a non-ionic detergent. In the second, a new alkyl ammonium salt comonomer, (3-allylamino-2-hydroxypropyl)dodecyldimethylammonium chloride was used, which is water soluble and has detergent properties itself. The alkyl group of this comonomer provides hydrophobicity while the ionic groups generate electroosmosis in the non-particulate bed. In the third approach, the alkyl comonomer was used as a detergent to dissolve another hydrophobic comonomer in an aqueous polymerization medium. All three approaches were evaluated with respect to hydrophobicity, efficiency and electroosmotic properties of the beds. Hydrophobicity expressed as methylene group selectivity for the three types of the beds in 50% methanol mobile phase was 1.86, 1.16 and 1.78, electroosmotic mobility -5.14 x 10(-5), 6.89 x 10(-5) and 6.37 x 10(-5) cm2 V(-1) s(-1) and efficiency for the retained compound (methylparabene) 67,000, 93,000 and 110,000 plates m(-1) correspondingly. The columns were tested using pressure driven capillary chromatography and capillary electrochromatography. The influence of polymerization temperature on hydrodynamic permeability, separation impedance and inverse size exclusion porosimetry characteristics were used to evaluate the separation columns. The increase of the polymerization temperature resulted higher permeability of the bed, separation impedance and lower polymeric skeleton porosity. Further characterisation was provided by examining the separation efficiency observed for a series of benzoic acid esters and alkyl parabens.

Chromatography, Gel↗

A comparison of performance of various analytical columns in pharmaceutical analysis: conventional C18 and high throughput C18 zorbax columns.

New improved types of analytical columns Zorbax Eclipse XDB-C18 (75 mm x 4.6 mm i.d., 3.5 microm) and Zorbax Eclipse XDB-C18 (50 mm x 4.6 mm i.d., 1.8 microm) have been tested for determination of estradiol (active substance), methylparaben, propylparaben (preservatives) and estrone (degradation product) and compared with the conventional C18 columns (250 mm x 3.0 mm i.d., 5.0 microm). The Zorbax columns differ with their particle size, column length and ODS (octadecylsilica) type as well. Higher flow-rates (up to about 2.5 ml min(-1)) could be applied regardless to back-pressure. The analysis - previously done at 40 degrees C - could be performed even at ambient temperature. Analytical run was shortened to 3.5 min (from 12 min used for the conventional C18 column) with the same or better retention characteristics. System suitability data for all Zorbax columns show the advantages of these columns for the practical use in routine quality control of pharmaceuticals, particularly from the point of view of speed of analysis and solvent consumption.

Chromatography, Liquid↗

Simultaneous analysis of antioxidants and preservatives in cosmetics by supercritical fluid extraction combined with liquid chromatography-mass spectrometry.

This study evaluated supercritical fluid extraction (SFE) combined with liquid chromatography-mass spectrometry (LC-MS) to determine trace preservatives and antioxidants including methylparaben (MP), ethylparaben (EP), propylparaben (PP), butylparaben (BP), butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT), alpha-tocopherol (alpha-t) and alpha-tocopherol acetate (alpha-ta) in cosmetic products. A supercritical fluid extraction procedure was used to isolate four paraben preservatives and four antioxidants from the cosmetic matrix before quantitative analysis. The optimum extraction condition was performed with static extraction for 5 min, then dynamic extraction for 20 min by using carbon dioxide supercritical fluid at 14,000 kPa and 65 degrees C. Methanol was used as collection solvent and the sea sand was chosen as a filling material. The analytes were separated on a C18 reversed-phase column using methanol-water as mobile phase and quantified by measuring its mass spectrometry. The linearity range is from 10 to 20,000 ng/g with RSD values below 18%. Detection limits are achieved at the level of 4.7-142 ng/g. It was successfully applied to the determination of paraben preservatives and antioxidants in cosmetics without tedious pretreatment.

Antioxidants↗

High performance liquid chromatographic determination of oxeladin citrate and oxybutynin hydrochloride and their degradation products.

Two high performance liquid chromatographic (HPLC) methods are presented for the determination of oxeladin citrate (OL) and oxybutynin hydrochloride (OB) and their degradation products. The first method was based on HPLC separation of OL from its degradation product using a Nucleosil C(18) column with a mobile phase consisting of acetonitrile -0.1% phosphoric acid (60:40 v/v). The second method was based on HPLC separation of OB from its degradation product using a VP-ODS C(18) column with a mobile phase consisting of acetonitrile/0.01 M potassium dihydrogen phosphate/diethylamine (60:40:0.2). Quantitation was achieved with UV detection at 220 nm based on peak area. The two HPLC methods were applied for the determination of OL or OB, their degradation products, methylparaben and propylparaben in pharmaceutical preparations. The proposed methods were used to investigate the kinetics of acidic and alkaline degradation processes of OL and OB at different temperatures and the apparent pseudofirst-order rate constant, half-life and activation energy were calculated. The pH-rate profiles of degradation of OL and OB in Britton-Robinson buffer solutions within the pH range 2-12 were studied.

Chromatography, High Pressure Liquid↗

Determination of combined p-hydroxy benzoic acid preservatives in a liquid pharmaceutical formulation by HPLC.

This paper describes a reversed-phase high performance liquid chromatographic (RP-HPLC) assay method for the determination of combined p-hydroxy benzoic acid (ethylparaben (EP), methylparaben (MP) and propylparaben (PP)) preservatives in a liquid pharmaceutical formulation. The chromatographic separation was achieved with potassium phosphate buffer (pH 7.05)-methanol (47.5:52.5, v/v) as mobile phase, a Spherisorb C(18) column (250 mm x 4.6mm) and UV detection at 254 nm. The analysis time was <8 min. The method was validated with respect to linearity, precision, accuracy, selectivity, specificity and ruggedness. The calibration curves showed good linearity over the concentration range of 2-140 microg/ml. The correlation coefficient were >0.9999 in each case. The relative standard deviation (R.S.D.) values for intra- and inter-day precision studies were <1%. The procedure describe here is simple, selective and is suitable for routine quality control analysis and stability tests.

Chemistry, Pharmaceutical↗

Application and validation of chemometrics-assisted spectrophotometry and liquid chromatography for the simultaneous determination of six-component pharmaceuticals.

Three methods are developed for the simultaneous determination of theophylline anhydrous (TH), guaiphenesin (GP), diphenhydramine hydrochloride (DP), methylparaben (MP), propylparaben (PP) and sodium benzoate (BZ) in pharmaceutical syrup. The chromatographic method depends on a high performance liquid chromatographic separation on a reversed-phase C(18) column at ambient temperature with mobile phase consisting of 25 mM KH2PO4, pH 3.2-acetonitrile (60:40, v/v). Quantitation was achieved with UV detection at 222 nm based on peak area. The other two chemometric methods applied were partial least squares (PLS-1) and principal component regression (PCR). These approaches were successfully applied to quantify the six components in the studied mixture using information included in the UV absorption spectra of appropriate solutions in the wavelength range of 220-270 nm with Deltalambda=0.4 nm. The calibration PLS-1 and PCR models were evaluated by internal validation (prediction of compounds in its own designed training set of calibration), by cross-validation (obtaining statistical parameters that show the efficiency for a calibration fit model) and by external validation over synthetic and pharmaceutical preparation. The results of PLS-1 and PCR methods were compared with the HPLC method and a good agreement was found.

Antitussive Agents↗

HPLC determination of calcium pantothenate and two preservatives in topical cream.

A RP-HPLC method for simultaneous determination of calcium pantothenate and two preservatives methylparaben and propylparaben present in topical cream was developed. Different analytical columns with various stationary phases were tested. During method development, Supelco Discovery C18 column (125 mmx4.0 mm, 5 microm) and Zorbax SB-CN column (150 mmx4.6 mm, 5 microm) were tested. Both were not convenient for analytical separation because of the co-elution of calcium pantothenate with dead volume, and problems with the peak-shape of all components. Good separation was achieved using Zorbax TSM (250 mmx4.6 mm, 5 microm) and Hypersil ODS column (250 mmx4.6 mm, 5 microm), the latter was finally used for the analysis. The analysis time was 12 min, at flow rate 0.7 ml min-1. Chromatography was performed using binary mobile phase composed of methanol and phosphoric acid, pH 2.5, 65:35 (v/v). UV detection was accomplished at 214 nm. The method was validated according to ICH guideline recommendations. The method is suitable for practical routine analysis of commercially produced topical pharmaceutical preparations.

Administration, Topical↗

Expression profiling of estrogen-responsive genes in breast cancer cells treated with alkylphenols, chlorinated phenols, parabens, or bis- and benzoylphenols for evaluation of estrogenic activity.

We examined expression profiles of estrogen-responsive genes after treatment with alkylphenols (p-cresol (pC), 4-n-ethylphenol (4EP), 4-n-heptylphenol (4HP), 4-t-octylphenol (4OP) and nonylphenol (NP)), chlorinated phenols (4-chlorophenol (4CP), 4-chloro-3,5-dimethylphenol (CDP), 2,4-dichlorophenol (DCP) and pentachlorophenol (PCP)), parabens (methylparaben (MPB), ethylparaben (EPB) propylparaben (PPB) and butylparaben (BuPB)), or bis- and benzoylphenols (bisphenols A and B and p-hydroxybenzophenone (pHBP)) by means of a DNA microarray assay first to evaluate the estrogenic activity of these chemicals and then to understand the structural basis for the activity. By selecting a set of 120 genes showing greater statistical reliability for estrogen, a more reliable assay for each of the chemicals was achieved and, for the chemicals for which data were available, the results were consistent with those of previously reported estrogen receptor-binding and yeast two-hybrid assays except for chlorinated and few other phenols. Evaluation of the chemicals based on gene function indicated that the genes related to proliferation, transcription and transport were mostly up-regulated while significant numbers of genes related to enzymes and signaling were down-regulated. The genes related to transcription showed the highest degree of variation among the six functional categories (enzymes, signaling, proliferation, transcription, transport and others) for the chemicals with relatively high levels of estrogenic activity. These results indicate that the variations in chemicals and their biological effects can be monitored by the appropriate grouping of estrogen-responsive genes.

Breast Neoplasms↗

Phacoemulsification procedures performed with topical anesthesia.

Phacoemulsification procedures with topical anesthesia, performed with small corneal incisions and 4% lidocaine hydrochloride methylparaben-free eye drops, have very high patient satisfaction rates because patients do not experience intraoperative pain, do not require sutures or eye patches, and have immediate improvements in their vision. Phacoemulsification procedures with topical anesthesia are cost-effective for surgery departments because patients have shorter hospitalizations and require fewer chargeable items. The perioperative nursing role is essential to the success of phacoemulsification procedures with topical anesthesia.

Anesthesia, Local↗

Separation and determination of haloperidol, parabens and some of their degradation products by micellar electrokinetic chromatography.

A micellar solution containing phosphate buffer, anionic surfactant, and water-miscible organic solvent was employed as a migration solution for the separation and the quantification of eleven analytes by micellar electrokinetic chromatography (MEKC): the analytes examined were haloperidol, methylparaben, ethylparaben, n-propylparaben, iso-propylparaben, n-butylparaben, iso-butylparaben, sec-butylparaben, 4-(4-chlorophenyl)-4-hydroxypiperidine, 4-fluorobenzoic acid and 4-hydroxybenzoic acid. In order to provide good separation between micelle and haloperidol, which showed strongest interaction with the micelle among the analytes, surfactant concentrations and organic modifier percentages were studied with phosphate buffer at pH 7.0. All the analytes were successfully resolved when 10 mM sodium dodecylsulfate and 15% ethanol were contained in the migration solution; the time window was very wide in the range from 14.8 to 65.5 min. Optimized applied voltage at 30 kV and capillary temperature at 45 degrees C enable analyze all compounds in less than 17 min with the best resolution, the shorter migration time window, the highest precision and lowest detection limit.

Benzoates↗

Reversed-phase porous silica rods, an alternative approach to high-performance liquid chromatographic separation using the sequential injection chromatography technique.

A commercially available porous silica rod column was used as a separation tool for the sequential injection analysis (SIA). A porous solid monolithic column showed high performance at a low pressure, allowing sequential injection analysis to be used for the first time for separation in HPLC fashion. In this contribution, we tried to demonstrate a new separation concept with SIA manifold for the simultaneous determination of four different compounds (methylparaben (MP), propylparaben (PP), triamcinolone acetonide (TCA) and internal standard ketoprofen (KP)) in a pharmaceutical triamcinolon cream 0.1% formulation. A Chromolith Flash RP-18e, 25 mm x 4.6 mm column with a 10 mm pre-column (Merck, Germany) and a FIAlab 3000 system (USA) with an 8-port selection valve and 10 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-methanol-water (35:5:65, v/v/v) + 0.05% nonylamine, pH 2.5, flow rate 0.6 ml min(-1). The analysis time was <6 min. A novel sequential injection chromatography (SIC) technique with UV spectrophotometric detection was optimised and validated.

Chromatography, High Pressure Liquid↗