PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ORTHODONTIC APPLIANCES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

[Examination of the effects of various orthodontic appliances on periodontal tissues].

This study has been planned to examine the effects of various orthodontic appliances on periodontal tissues and the effect of motivation from the point of oral hygiene during the usage period of these appliances. 45 individuals; 15 of them using removable appliances, 15 of them using fixed-DBS appliances and 15 of the patients treating with fixed-multiband technics, have been used. In the beginning; the pocket depths, gingival and plaque indices of all cases have been reported and then they were motivated for their oral hygiene. The measurements were repeated for each of the motivated cases after 1 month. Statistically significant difference was found only in pocket depth between the 3 groups. There were statistically significant differences in pocket depth, gingival and plaque indices values in each of the groups before and after motivation.

Female↗

Pain control during fixed orthodontic appliance therapy.

The control of pain during orthodontic treatment is of great interest to both clinicians and patients. However, there has been limited research into the control of this pain, and there is no standard of care for controlling this discomfort. This prospective study determines the pain sequelae in fixed orthodontic treatment and evaluates comparatively the analgesic effects of nonsteroidal anti-inflammatory drugs for the control of this pain. One hundred and fifty orthodontic patients who were to have teeth bonded in at least one arch were randomly assigned to one of six groups: (1) placebo/placebo, (2) ibuprofen/ibuprofen, (3) flurbiprofen/flurbiprofen, (4) acetaminophen/acetaminophen, (5) naproxen sodium/naproxen sodium, and (6) aspirin/aspirin. The pain evaluations were made during chewing, biting, fitting the front teeth, and fitting the back teeth using a 100-mm visual analogue scale (VAS) for seven days. All the analgesics succeeded in decreasing the pain levels compared with the placebo group. However, naproxen sodium and aspirin groups showed the lowest pain values, and the acetaminophen group showed VAS results similar to those of the two analgesics.

Acetaminophen↗

An evaluation of beta titanium alloys for use in orthodontic appliances.

A beta titanium alloy was evaluated for use in orthodontic appliances. Standard mechanical tests and aspecially designed spring test were used. Two particular thermo-mechanical treatments resulted in titanium springs with 1.8 times the extension of comparable stainless steel springs, and a 2.2 fold reduction in force per unit displacement.

Dental Alloys↗

Fatigue resistance of removable orthodontic appliance reinforced with glass fibre weave.

The aim of this study was to measure the fatigue resistance of fibre-reinforced composite (FRC) reinforced polymeric parts of a removable orthodontic appliance beside the clasp. The effect of quantity and position of FRC-reinforcement were investigated. In addition, the influence of water storage on the fatigue properties was determined. The test specimens for eight groups (n=6) were manufactured from autopolymerizing acrylic resin. Polymethylmethacrylate pre-impregnated woven glass fibre was used as reinforcement of acrylic resin specimens at the region of steel wire clasp. The test specimens of the control group were not reinforced. In the second group, the test specimens were reinforced with one fibre layer (thickness: 0.06 mm) on the tension side, and in the third and fourth group with two fibre layers. Fatigue resistance was measured by applying repeated bending force to the clasp. The highest fatigue resistance values were achieved when the test specimens were fibre-reinforced with two fibre layers. The lowest fatigue resistance values resulted when the test specimens were not reinforced (P=0.046, anova). Water storage had a tendency to decrease the fatigue resistance in all fibre reinforced test specimen groups. The results suggest that use of the woven polymer pre-impregnated glass FRC-reinforcement increases the fracture resistance of orthodontic appliance made of acrylic polymer.

Absorption↗

Effect of a hydrophobic tooth coating on gingival health, mutans streptococci, and enamel demineralization in adolescents with fixed orthodontic appliances.

The effect of an anti-adhesive enamel coating on plaque accumulation, gingival health, and enamel demineralization was evaluated in 39 adolescents undergoing treatment with fixed orthodontic appliances using a prospective split-mouth design. Immediately after bracket insertion, the polymer was randomly applied after enamel etching to the buccal surfaces of the teeth in the left or right upper quadrant, leaving the opposite quadrant as an untreated control (218 test and 216 control teeth). Reapplications were carried out every 3rd month during the course or the study. The following data were collected at baseline and at designated follow-ups: visible plaque index, total viable counts and proportion of mutans streptococci in plaque samples, gingival bleeding index, and amount of gingival crevicular fluid. The incidence of enamel demineralization adjacent to the appliances was scored clinically at the termination of the orthodontic treatment. The observation time ranged from 6-24 months, during which the participants used fluoride rinses and toothpaste daily. A slightly impaired gingival health and increased levels or mutans streptococci compared with baseline was disclosed during the treatment. Five subjects showed enamel demineralization on a total of 30 teeth at the time of de-bonding. The results indicated no statistically significant differences between the enamel-coated and untreated teeth with regard to the studied variables at any follow-up. In conclusion, the present findings did not support a clinically beneficial effect of the polymeric tooth coating in a low-caries group of adolescents treated with fixed orthodontic appliances.

Acrylates↗

Two-couple orthodontic appliance systems: activations in the transverse dimension.

Partially bracketed arch wires can be activated in the transverse dimension to produce first-order rotations of the molars and constriction or expansion of intermolar width. A 2 x 6 arch wire is ideal for such activations because of the minimal side effects to the anterior teeth. As with other two-couple orthodontic appliance systems, symmetrical V-bends, asymmetrical V-bends and step bends are used to generate moments of the couples whose associated equilibrium forces can be used to produce desired tooth movement.

Cuspid↗

Activation time and material stiffness of sequential removable orthodontic appliances. Part 1: Ability to complete treatment.

Recent advances in technology have led to the availability of sequential removable orthodontic appliances (aligners) to move teeth in a stepwise fashion (Invisalign, Align Technology, Santa Clara, Calif). This study was undertaken to compare 2 distinctly different materials (hard and soft) and 2 activation frequencies (1 week and 2 weeks) for this technique. Fifty-one subjects, stratified by peer assessment rating (PAR) and need for extractions, were randomly assigned to a hard or a soft plastic appliance, and a 1-week or 2-week activation time. The primary endpoint was the completion of the initially prescribed series of aligners. Changing aligners every other week was more likely to lead to completion of the initial series of aligners than changing aligners weekly (37% vs 21%). No substantial difference in the completion rate was observed for the soft versus the hard appliance (27% vs. 32%). The completion rate was highest (46%) among patients with PAR scores less than 15 and no planned extractions, and lowest (0%) among subjects who had 2 or more premolars extracted. All who completed their initial series of aligners required an additional series of aligners or fixed appliances to achieve the original treatment goals. This exploratory study suggests that subjects with a 2-week activation regimen, no extractions, and a low PAR score are more likely to complete their initial series of aligners.

Activator Appliances↗

Cephalometric appraisal of patients treated with fixed lingual orthodontic appliances: historic review and analysis of cases.

In the first part of this article, a retrospective look was taken of evolvement and progression in design of the lingual fixed orthodontic appliance. The second part is a retrospective study of treated lingual cases. By the use of standardized cephalometric radiographs, selected treatment parameters were analyzed:--namely, bite opening, changes in mandibular position, inclination, torque and intrusion of incisors, and soft-tissue effects. For the clinician who uses this treatment modality, the most significant effects are the bite opening, intrusion of the mandibular incisors (particularly in extraction cases), and limited reduction of lower lip protrusion. The mandibular plane angle and torque and inclination of incisors did not follow a consistent and predictable pattern. On the basis of the study's findings, it is suggested that lingual fixed appliance therapy is a useful supplement to our treatment modalities; good results are both realistic and possible.

Cephalometry↗

Variations in bracket placement in the preadjusted orthodontic appliance.

This study was conducted to determine the accuracy of bracket placement with the direct bonded technique. Ten orthodontic faculty members bonded a preadjusted orthodontic appliance on models of five cases of malocclusion in a simulated clinical situation (mannequin). A total of 50 sets of models served as the population of the study. Photographs of the models were measured to determine vertical and angular discrepancies in position between adjacent bracket pairs from a constructed reference line. Variations are evaluated with respect to the classification of malocclusion, specific tooth type, and intra/inter operator differences. A mean of 0.34 mm for the vertical discrepancies and a mean of 5.54 degrees for the angular discrepancies are found in placement of the orthodontic brackets.

Analysis of Variance↗

A study of forces originating from orthodontic appliances for splinting of teeth.

Management of dental trauma in children sometimes requires the use of a dental splint. This can be constructed with composite materials, kevlar, fiberglass, wire and composite or orthodontic wires and brackets. However, there have been no studies of the control of dental movement when orthodontic materials are used for a dental splint. The purpose of this study was to determine the forces exerted by an orthodontic appliance used as a dental splint. To measure such forces, a transducer with a detection of 0.01 N (+/- 5%) was inserted into a maxillary dental arch model. The results showed that the orthodontic wire was rarely passive and the forces developed ranged from 0 to 27 x 10(-2) N. The force developed was independent of the length of the dental splint (p < 0.05) and wire size (p < 0.05). The mean force developed by nickel-titanium wires (14.27 x 10(-2) N) was significantly greater (p < 0.05) than the mean force developed by stainless steel and cobalt-chromium wires. Moreover, the mean force developed by rectangular wires (12.07 x 10(-2) N) was significantly greater (p < 0.05) than the mean force developed by square and round wires. The results suggested that stainless steel or cobalt-chromium, square or round wires should be used for construction of a dental splint.

Analysis of Variance↗

Airborne particles produced during enamel cleanup after removal of orthodontic appliances.

Airborne particles can be produced during enamel cleanup after the removal of fixed orthodontic appliances. Particles with an aerodynamic diameter of less than 2.5 microm, known as PM2.5, can reach the alveoli of the lungs. The aim of this experiment was to qualitatively determine whether such particles are produced during enamel cleanup at the end of orthodontic treatment. Particles were collected and examined under a scanning electron microscope. Aerodynamic diameters of the particles ranged from approximately 2 to 30 microm. X-ray analysis confirmed not only the presence of components of the adhesives being removed, but also tungsten from the bur and tooth enamel. In conclusion, inhalable particles can be produced during enamel cleanup at the completion of orthodontic treatment. Further investigation is required to determine the clinical significance of such particles, how their production can be minimized, and whether even smaller, fine or ultrafine, particles are produced.

Aerosols↗