PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Porosity”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

The influence of porosity and pore size on the ultrasonic properties of bone investigated using a phantom material.

Ultrasonic propagation in bone has been investigated using the Leeds Ultrasonic Bone Phantom Material. Phantoms were produced with different porosities in the range of 45-83% and pore sizes of 1.3 and 0.6 mm. The phase velocity at 600 kHz was found to follow a second-order polynomial as a function of porosity. Phase velocity values between 1545 and 2211 m s-1 were measured and found to be largely independent of pore size for a given porosity. The slope of the phase velocity as a function of frequency (dispersion) decreases with increasing porosity. The values obtained from samples having different pore sizes were also similar. The attenuation coefficient and normalized broadband ultrasonic attenuation (nBUA) reached a maximum at about 50%. The normalized attenuation ranged from 6 to 25 dB cm-1 over the porosity range available and consistently showed higher values for the larger pore size. Similarly, the nBUA values were found to be between 14 and 53 dB MHz-1 cm-1, with the values for the larger pore size being roughly 10 dB MHz-1 cm-1 greater than those for the smaller pore size. These findings demonstrate that the Leeds phantom can be used to investigate the effect of structural changes in bone and to aid the understanding of quantitative ultrasound. The results support the assumption that the velocity in trabecular bone is not dependent on pore size but is influenced by the mechanical properties of the bone's constituents and the overall framework, whereas the attenuation and BUA are also influenced by structure.

Bone Density↗

On the optimisation of the bed porosity and the particle shape of ordered chromatographic separation media.

We report on a theoretical study wherein we considered a large number of ordered two-dimensional porous pillar arrays with different pillar shapes and widely varying external porosity and calculated the flow resistance and the band broadening (under retentive conditions) over the complete range of practical velocities using a commercial computational fluid dynamics software package. It is found that the performance of the small porosity systems is very sensitive to the exact pillar shape, whereas this difference gradually disappears with increasing porosity. The obtained separation impedances are very small in comparison to packed bed and monolithic columns and decrease with increasing porosity. If accounting for the current micromachining limitations, a proper selection of the exact shape and porosity even becomes more critical, and different design rules are obtained depending on whether porous or non-porous pillars are considered.

Chromatography, Liquid↗

Biological sealants and knitted Dacron: porosity and histological comparisons of vascular graft materials with and without collagen and fibrin glue pretreatments.

Woven Dacron used in extracardiac conduits tends to form a poorly adherent, obstructing layer of pseudointima. Knitted high-porosity conduits allow fibrous and vascular ingrowth and more secure anchoring of the pseudointima. However, at the time of insertion, the porosity rate must be sufficiently low to prevent excessive bleeding in the heparinized patient. Pretreatments with biological sealants are available to temporarily reduce the porosity of knitted Dacron at the time of implantation with subsequent resorption of the sealant. We compared in vitro water porosity rates of knitted Dacron pretreated with conventional techniques, fibrin glue, and collagen impregnation. Only the collagen-impregnated and fibrin glue-treated grafts decreased the porosity of knitted Dacron to an acceptable level. To assess the biocompatibility and resorption of biomaterials used in sealing conduits, pretreated Dacron was implanted subcutaneously in weaning rats. Foreign-body response of untreated Dacron was unchanged by conventional techniques. Fibrin glue also resulted in good capillary ingrowth as well as occasional punctate multifocal deposits of calcium phosphate. The collagen-impregnated grafts differed in the intensity of the inflammatory response and tissue adhesion, possibly related to the degree of collagen cross-linking. This may have important implications regarding structure of the pseudointima in vascular grafts sealed with these materials.

Biocompatible Materials↗

Fabrication of poly(phosphoester) nerve guides by immersion precipitation and the control of porosity.

Immersion precipitation was employed as a method for the fabrication of polymeric conduits from P(BHET-EOP/TC), a poly(phosphoester) with an ethylene terephthalate backbone, to be applied as guidance channels for nerve regeneration. Coatings of various porosities could be obtained by immersing mandrels coated with a solution of the polymer in chloroform into non-solvent immersion baths, followed by freeze or vacuum-drying. The porosity of the coatings decreased with an increase in polymer molecular weight, drying time before precipitation and concentration of polymer solution. The effects of these parameters can be rationalized by employing ternary phase diagrams, where porosity is directly related to the degree of phase separation available to the system before gelation occurs. To afford improved porosity control, a new system was developed which employed the contrasting phase-separation behavior of P(BHET-EOP/TC)/chloroform solution in methanol and water. As water is essentially a non-solvent for the polymer, the demixing boundary of the P(BHET-EOP/TC)-CHCl3-H2O system is located close to the polymer-solvent edge of the phase diagram, while that of the P(BHET-EOP/TC)-CHCl3-MeOH system is located further away. A mixture of methanol and water allows the demixing boundary to be shifted to intermediate coordinates. By immersing P(BHET-EOP/TC) coatings in immersion baths containing different ratios of water and methanol, then gradually titrating the bath with methanol to a concentration of 70% (v/v) methanol, surface porosities ranging from 2 to 58% could be achieved.

Biocompatible Materials↗

The non-linear relationship between BUA and porosity in cancellous bone.

There is growing interest in assessing the clinical value of ultrasound in the prediction and management of osteoporosis. However, the mechanism of ultrasound propagation in cancellous bone is not well understood. The Biot theory is one approach to modelling the interaction of sound waves with cancellous structure, and porosity is one of its input parameters. In this paper we report the relationship between broadband ultrasonic attenuation (BUA) corrected for specimen thickness (nBUA) and porosity in a porous Perspex cancellous bone mimic, a stereolithography cancellous bone mimic and in natural human and bovine tissue. nBUA and porosity have a non-linear parabolic relationship. The maximum nBUA value (nBUAmax) occurs at approximately 30% porosity in the Perspex mimic, approximately 70% in the stereolithography mimic and approximately 75% in natural cancellous bone. We discuss the effect of structure on the form of the nBUA-porosity relationship.

Animals↗

The influence of denier and porosity on performance of a warp-knit Dacron arterial prosthesis.

The study objective was to determine the optimal water porosity for a warp-knit, externally veloured Dacron arterial prosthesis. Preclotting efficiency, surgical handling characteristics, thrombogenicity, and 56-day healing in the descending thoracic aorta of mongrel dogs were measured for seven different arterial prostheses of the same basic design constructed to test the influence of decreased porosity produced by increased yarn denier at a constant needle density. The six prototypes tested were 160, 180, 200, 220, 240, and 280 denier. The 140 denier prosthesis (Bionit, C. R. Bard, Inc., Billerica, MA) served as the control. The water porosity of these prostheses varied from 2036 ml/cm2/min at 120 mmHg for the control to 286 for the 280 prototype. The preclotting efficiency increased with decreased water porosity and with increased outer-wall filamentousness. Desirability of surgical handling characteristics decreased with lowered water porosity, while the degree of outer-wall filamentousness had little influence. All the prostheses showed excellent through-wall healing at 56 days, including endothelialization. The 160 prototype represented an optimal blend of high preclotting efficiency, desirable surgical handling characteristics, and excellent 56-day healing. These studies are pertinent to the future development of porous, warp-knit Dacron arterial prostheses.

Animals↗

The measurement of the adhesion of film coatings to tablet surfaces: the effect of tablet porosity, surface roughness and film thickness.

The effect of tablet porosity, surface roughness and film thickness on the adhesion of hydroxypropyl methyl cellulose films to placebo tablet substrates have been studied using a specially designed tensile tester (Fisher & Rowe, 4976). There were direct relations between measured adhesion and tablet porosity and also surface roughness and tablet porosity. The effect of film thickness on the measured adhesion is complex with an initial decrease with thicknesses up to 35 micron and then a gradual increase with thicknesses up to 140 micron dut to differences in the strees distribution within the film during testing. A knowledge of these effects is necessary if results from various sources are to be compared. The findings illustrate the potential capability of the extrapolation of measured adhesion results to zero porosity and zero thickness values in order to obtain a measure of the true or intrinsic adhesion at any film/tablet interface without the confusing elements of tablet porosity, surface roughness and residual stresses in the film.

Adhesiveness↗

Determination of porosity variations in powder beds.

A gamma-ray attenuation technique for detecting local porosity variations in packings of pharmaceutical powders has been developed and assessed. It proved necessary to employ an empirical expression describing the attenuation coefficient of the model material, lactose, as a function of porosity. The precision of measurement of local porosity can be pre-selected due to the statistical basis of the method, and local porosity measurements with 95% confidence intervals of +/- 0.005 can readily be carried out. A method of producing grey-scale images of porosity distributions has been employed to enable the degree of inhomogeneity of a powder bed to be seen.

Gamma Rays↗

CT of the middiaphyseal femur: cortical bone mineral density and relation to porosity.

PURPOSE: To determine whether computed tomography (CT) can be used to quantify age- and site-related changes in cortical bone mineral density (cBMD) at the middiaphyseal femur and whether cBMD differences are related to intracortical porosity. MATERIALS AND METHODS: Cortical bone specimens from 163 femurs were studied with CT and microradiography. Femurs were from 77 males and 86 females in a white anthropologic collection covering a broad age spectrum. In each sample, the cBMD was measured in the entire cortical width and in periosteal, midcortical, and endosteal subregions of interest. Age- and site-related changes in cBMD were tested for significance by using a two-way analysis of variance for both sexes. By using linear regression, cBMD was compared with porosity in the entire cortical width and in each subregion. RESULTS: There were significant age-related differences in cBMD (P <.001 in females, P =.008 in males). In addition, cBMD values were significantly different between the three cortical subregions (P <.001 for both sexes), decreasing from the periosteum to the midcortex to the endosteum. The cBMD values were closely related to porosity, and porosity contributed to 71.6% of the variance in cBMD in the overall population. CONCLUSION: CT is effective in the measurement of age- and site-related changes in cBMD. Decreases in cBMD are closely correlated with increased cortical porosity.

Adolescent↗

Tooth colored dental restorative materials: porosities and surface topography in relation to bacterial adhesion.

The present investigation was carried out to determine whether differences in initial bacterial accumulation on dental restorations could be explained by differences in surface topography, particularly porosities, of the materials. A point counting method was used to determine the number and the size of the porosities in 15 materials. The results demonstrated great variation among the materials in the number of porosities. However, in vitro bacterial adhesion tests failed to show any relationship between porosities in the materials and the number of bacteria adhering to them. Nor were differences in surface topography, as measured profilometrically, associated with differences in bacterial adhesion. It is concluded that variations in surface topography including porosities do not suffice to explain differences in initial bacterial accumulation on silicate cements and composite dental restoratives.

Adhesiveness↗

[Improvement and application of digitized measure on shelterbelt porosity].

Based on the lots of investigation on farmland shelterbelts, we used digital camera to take pictures of shelterbelt and apply CIAS software to improve "digital image processing" for determining shelterbelt porosity so as to thoroughly analyze the rule of porosity in farmland shelterbelts. Compared with the old digital image processing, the improved method possesses high accuracy, and it is more economical and more convenient to apply. The relationship between porosity of shelterbelts (beta) and relative clear bole height (x) can be expressed as beta = 0.672x0.469 (r = 0.9851, r0.01 = 0.4073, 0 < or = beta < or = 1) in the leaf period; and beta = 1.0681x0.4304 (r = 0.9763, r0.01 = 0.4073, 0 < or = beta < or = 1) in the defoliation period. beta varies with the stand age (a), taking the form of parabola, which can be expressed as beta = 0.0009a2 - 0.0364a + 0.6828 (0 < or = beta < or = 1). Porosity at cross-section of shelterbelt can be used as an auxiliary index to evaluate the structure of belts. The calculation method of shelterbelt porosity of mixed shelterbelt can be expressed as beta = (beta 1n1 + beta 2n2)/(n1 + n2). Among the popular, willow and elm pure shelterbelts with same disposition, popular shelterbelt structure is the best, with beta PPP < beta SSS < beta UUU, while the triangle disposition is better than the rectangle one among the same tree species. UPPU and SPPS of mixed structure have the optimal effect in popular-willow-elm mixed shelterbelts.

Trees↗

Porosity--strength relationship in a Cu-rich spherical alloy amalgam.

Porosity and strength of spherical Cu-rich alloy amalgams were analyzed in the under-graduate materials laboratory. The minimum value for porosity was obtained for 46% initial Hg content, whereas the maximum strengths were obtained for 42% initial Hg. This result did not coincide with the data previously obtained for the conventional spherical alloy amalgam, in which the maximum strength and the minimum porosity were strictly associated with the optimum initial Hg content. Although no critical value for porosity could be definitely demonstrated by this effort, this result may be an indirect indication for 4.5 vol% porosity as the critical value.

Copper↗

Changes in vascular porosity and joint blood flow during development of collagen induced arthritis in the rat. Modulation by indomethacin and L-NAME.

OBJECTIVE: To investigate changes in regional blood flows (RBF) and vascular porosity during the early phase of the autologous collagen II induced arthritis model (CIA) in rats and the possible influence of indomethacin and nitric oxide (NO) synthase on these variables. METHODS: RBF was measured with the microsphere method and vascular porosity by determination of extravasation of radiolabeled albumin. RESULTS: Onset of arthritis was associated with a rapid increase in vascular porosity in the knee. In ankles and paws this increase was somewhat slower in onset, but progressed during the course of the study. Acute treatment with indomethacin reduced albumin extravasation in the knees, but had no effect in the ankles or paws. Similarly, chronic indomethacin treatment also had no effect on the arthritic score. Serum levels of nitrite/nitrate did not change markedly during the development of CIA, and NO synthase inhibition did not affect the vascular porosity. The changes in RBF were relatively modest. In most tissues the total RBF increased with increasing tissue weight. Pretreatment with indomethacin reduced RBF in the paws, but not in the periarticular tissue. CONCLUSION: The development of CIA is characterized by a marked rise in vascular porosity in affected joints, but the changes in RBF are much smaller and nonpersistent. The leakiness seems to be insensitive to the modulation of RBF and the responses in the knee show different characteristics compared to those in the ankle/paw.

Animals↗

Effect of porosity on small-diameter vascular graft healing.

Experimental studies have reported that complete healing of small-diameter expanded polytetrafluoroethylene (ePTFE) grafts occurs only if the porosity of the graft is increased, thereby allowing ingrowth of perigraft capillaries yielding endothelial cells. This study investigates the effects of varied graft porosity on the healing characteristics of 2-mm internal diameter (ID) ePTFE grafts interposed in the rabbit common carotid artery. Four groups were evaluated: Group A (n = 8) standard (30-microm pores) ePTFE grafts; Group B (n = 8) increased porosity (60-microm pores) ePTFE grafts; Group C (n = 8) standard ePTFE; and Group D (n = 8) 60-microm ePTFE external graft surface was externally coated with an impermeable layer of polyurethane. Patency was 100% for all groups at 8 weeks. At explantation, the neointima was composed of primarily modified smooth muscle cells. Endothelial cells were only identified at the perianastomotic region using the endothelial cell-specific antibody CD31. The impermeable external polyurethane coating of ePTFE grafts had no effect on neointima formation, regardless of porosity.

Animals↗

Effect of porosity reduction by compaction on compressive strength and microstructure of calcium phosphate cement.

Hydroxyapatite (HA) calcium phosphate cements (CPCs) are attractive materials for orthopedic applications because they can be molded into shape during implantation. However their low strength and brittle nature limits their potential applications to principally non-load-bearing applications. Little if any use has been made of the HA cement systems as manufacturing routes for preset HA bone grafts, which although not moldable pastes, are resorbable, unlike HA sintered ceramic. It is known that the strength of cements can be increased beyond that attainable from slurry systems by compaction, and this study investigates whether compaction significantly alters the specific surface area and pore-size distribution of CPC prepared according to the method of Brown and Chow. Compaction pressures of between 18 and 106 MPa were used to decrease the porosity from 50 to 31%, which resulted in an increase in the wet compressive strength from 4 to 37 MPa. The Weibull modulus was found to increase as porosity decreased; in addition the amount of porosity larger than the reactant particle size increased as porosity decreased. It is proposed that this was caused by a combination of voids created by the aqueous solvent used in fabrication and shrinkage that occurs on reaction. The specific surface area was unchanged by compaction.

Biocompatible Materials↗

Porcine bladder acellular matrix porosity: impact of hyaluronic acid and lyophilization.

Bladder acellular matrix (ACM) is being investigated as a urinary bladder replacement scaffold. We have demonstrated that ACM is porous and theorized that this contributes to ACM fibrosis and contracture over time in vivo and may preclude uptake and retention of molecules, which may aid cellular repopulation. We sought to determine if hyaluronic acid (HA) would decrease ACM porosity. Porcine ACM was lyophilized and rehydrated in HA (SIGMA) to form the hybrid HA-ACM construct. Three groups (n = 15/group: HA-ACM, ACM, and lyophilized/rehydrated ACM) were tested for porosity to a 10 cm column of distilled water, measuring the effluent hourly for 3 h. A porosity index was determined as the total effluent divided by time and area (cc/cm2 hr). Alcian blue staining and fluorophore-assisted carbohydrate electrophoresis qualitatively and quantitatively confirmed the uptake of HA. HA-ACM and lyophilized/rehydrated ACM were significantly less porous to water than untreated ACM [mean (+/-SE): 0.09 (+/-0.02), 0.74 (+/-0.4), and 9.8 (+/-1.6) cc/cm2 hr, respectively; Mann Whitney p < 0.0001 (HA) and p < 0.0001 (lyo)]. The difference between HA-ACM and lyophilized ACM was also statistically significant (p = 0.014). ACM hybridization with HA decreases ACM porosity, in part because of ACM lyophilization during the hybridization process. In future applications, HA may function as a carrier for smaller molecules such as growth factors, and as a bioactive molecule to improve wound healing and decrease fibrosis in tissue-engineered bladder constructs.

Animals↗

High-porosity expanded polytetrafluoroethylene grafts for thoracic vena cava replacement with or without an omentum wrap.

We previously reported that, in a short-term thoracic inferior vena cava (IVC) replacement, a high-porosity expanded polytetrafluoroethylene (ePTFE) graft (fibril length 60 microm) performed well without altering the short-term patency, and that the healing of the high-porosity ePTFE graft was accelerated by an omentum wrap. The purpose of this study was to examine the long-term performance of the high-porosity ePTFE graft with or without an omentum wrap. Eighteen grafts were placed as a thoracic IVC replacement in dogs. Nine of the grafts were wrapped in an omental pedicle flap while the other 9 were not. At 1 month and 6 months, the grafts were harvested and examined for a pathological analysis. During the observation period, one dog died of a viral infection, while the other 17 dogs survived. At 1 month and 6 months, the patency rates of the 17 grafts were 100% regardless of the presence or absence of an omentum wrap. The healing of the grafts without omentum wrap was incomplete 6 months after implantation; granulation tissue was present in the center of the pseudointima. The grafts healed completely by the addition of an omentum wrap. Our data suggest that, with an omentum wrap, the high-porosity ePTFE graft is fully expected to show a good long-term function.

Animals↗

An ionised/non-ionised dual porosity model of intervertebral disc tissue.

The volume of the intrafibrillar water space--i.e. the water contained inside the collagen fibres--is a key parameter that is relevant to concepts of connective tissue structure and function. Confined compression and swelling experiments on annulus fibrosus samples are interpreted in terms of a dual porosity model that distinguishes between a non-ionised intrafibrillar porosity and an ionised extrafibrillar porosity. Both porosities intercommunicate and are saturated with a monovalent ionic solution, i.c. NaCl. The extrafibrillar fixed charge density of the samples is assessed using radiotracer techniques and the collagen content is evaluated by measurement of hydroxyproline concentration. The interpretation of the experimental data yields values for the intrafibrillar water content, the average activity coefficient of the ions, the Donnan osmotic coefficient, the fraction of intrafibrillar water, the stress-free deformation state, and an effective stress-strain relationship as a function of the radial position in the disc. A linear fit between the second Piola-Kirchhoff effective stress and Green-Lagrange strain yielded an effective stiffness: H(e)=1.087 +/- 0.657 MPa. The average fraction of intrafibrillar water was 1.16 g/g collagen. The results were sensitive to changes in the activity and osmotic coefficients and the fraction of intrafibrillar water. The fixed charge density increased with distance from the outer edge of the annulus, whereas the hydroxyproline decreased.

Animals↗