PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Recall rate”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Estimating the validity of the guilty knowledge test from simulated experiments: the external validity of mock crime studies.

This experiment was designed to examine the external validity of the standard mock-crime procedure used extensively to evaluate the validity of polygraph tests. The authors manipulated the type of mock-crime procedure (standard vs. a more realistic version) and the time of test (immediate vs. delayed) and examined their effects on the validity of the Guilty Knowledge Test (GKT) and the recall rate of the relevant items. The results indicated that only the type of mock-crime affected the 2 outcome variables. The realistic procedure was associated with a lower recall rate and weaker detection efficiency than the standard procedure. However, these effects were mediated by the type of GKT questions used. Practical implications of these results are discussed.

Adult↗

Neonatal screening for congenital hypothyroidism and phenylketonuria at Siriraj Hospital, Mahidol University, Bangkok, Thailand--a pilot study.

A newborn screening program for congenital hypothyroidism (CH) and phenylketonuria (PKU), a pilot study, was initiated at the Medical Genetics Unit, Department of Pediatrics, Siriraj Hospital Faculty of Medicine, Mahidol University in Bangkok, Thailand from January 1994 to December 1998, using dried blood spots (DBS). A total of 18,739 infants (out of 85,150 livebirths) were screened (22 % coverage). Three cases of congenital hypothyroidism (CH) were identified (incidence of 1: 6,246, livebirths), by enzyme linked immunosorbent (ELISA) and fluoroimmunoassays using a cut-off level of TSH >20 microlU/ml: the recall rate of 0.24%. The screening for PKU was done by fluorometric (Guthrie) and enzyme linked immunosorbent (ELISA) methods; using cut-off levels of phenylalanine > 4 mg/dl and > 3.6 mg/dl respectively, with a recall rate of 0.13%. There was no PKU found. Our study, a voluntary program, emphasizes the importance of parental education and consent; specimen collection and handling; appropriate follow-up and referral to specialists for treatment and counseling. Routine newborn screening for CH and PKU is being established to ascertain the maximum coverage, using recommendations and guidelines from this pilot study.

Congenital Hypothyroidism↗

Studies on congenital hypothyroidism and results of three and half years of compulsory screening program in Slovak Socialist Republic.

In the introduction the results of previous retrospective study (1975-79) including 312,259 newborns and of preliminary screening program including 31,780 newborns are briefly summarized. After January 1st, 1985 a compulsory screening of congenital hypothyroidism (CH) was started in the whole territory of Slovakia using the estimation of thyroxine in dry blood spot obtained from a heel prick on 5th day after birth. In suspected cases a complete clinical and laboratory examination was made including TSH estimation by RIA and after January 1st, 1988 by IRMA. The organization of screening program is described in detail. During three and half year period 286,469 newborns were examined which represented almost 100 percent of all newborns. A total of 44 cases of CH was found out of them 13 cases of athyreosis, 3 cases of ectopic thyroid and 28 cases of dyshormonogenesis (among them 5 cases with goiter and 23 cases without goiter). The average incidence of CH was 1:6874. Until January 1st, 1988 (when only T4 estimation was used as a first step) the recall rate was 2.32% and the treatment was started before 25th day after birth, while after the use of TSH by IRMA from dry blood spot in suspected cases (i.e. after January 1st, 1988) the recall rate decreased to 0.82% and the treatment was started before 14th day of life. In addition, the data on 39 cases of TBG deficiency and on regional differences in their incidence are reported. Some remarkable differences in the incidence of total CH and of its individual variants between West, Central and East Slovakia with different historical, cultural, economical and genetical background as well as in some ethnic groups (Gypsies) are also presented.

Congenital Hypothyroidism↗

Controversies in mammography.

Concerns about screening mammography include questions of efficacy, high recall rates, false positives, and age at which to institute annual screening. Annual screening mammography can decrease breast cancer mortality by 45% in women over fifty and 23% in women between forty and fifty years of age. Patient recall rates and accuracy of interpretation vary among radiologists. Suggestions for improving accuracy of mammographic interpretation include continuing education with emphasis on quality of interpretation, computer-assisted detection, double reading, increased volume per reader, and performance-related skills testing. Having fewer radiologists reading more mammograms may result in decreased patient access to mammography services. Poor reimbursement for mammography and high prevalence of breast cancer-related litigation are disincentives for radiologists to provide mammography services; these issues must be addressed to ensure patient access to mammography. The public must be educated so that reasonable expectations on the benefits and limitations of mammography will develop.

Breast Neoplasms↗

Five-year thyrotropin screening for congenital hypothyroidism in Ramathibodi Hospital.

OBJECTIVES: To detect newborns with congenital hypothyroidism (CH) and to treat the affected infants as early as possible. STUDY DESIGN: Cord blood thyrotropin (TSH) screening for CH in Ramathibodi Hospital began in 1993. From October 1993 to December 1998, 35,390 neonates were screened. The infants with elevated TSH level of greater than 30 mU/L were recalled for verification of CH. Confirmation tests included total thyroxine, free thyroxine and TSH level. Thyroid scan and uptake were performed in some affected infants. RESULTS: Twelve infants with CH were detected resulting in an incidence of one in 2,949 live-births. All affected infants were asymptomatic at birth. Of 12 infants with CH, one premature neonate had a delayed TSH elevation and was diagnosed as having primary hypothyroidism at 2 months of age. The recall rate for validation of CH based on a cut-off value at serum TSH level of greater than 30 mU/L is 1.1 per cent. If the cut-off value of serum TSH level was raised to greater than 40 mU/L, the recall rate would decrease to 0.43 per cent. None of the affected infants had cord blood TSH level of less than 50 mU/L except one premature patient. Therefore, beginning in January 1997, the cut-off value of TSH was raised to 40 mU/L or greater. Pitfalls in this program include incomplete blood-specimen collection and incomplete follow-up. To strengthen the program, improvements were made in the follow-up system from 1996 onward. Therefore, the coverage for blood-specimen collection progressively increased from 84 per cent in 1994 to 96 per cent in 1998. Simultaneously, the patients' return after recalls also increased from 38 per cent to 100 per cent. CONCLUSIONS: The incidence of CH in Ramathibodi Hospital is approximately 1:3,000 live-births. The optimal cord blood TSH level for recall is 40 mU/L or greater. The intensification of follow-up strategy resulted in better response to recall and earlier treatment in the affected infants.

Congenital Hypothyroidism↗

Comparison of standard reading and computer aided detection (CAD) on a national proficiency test of screening mammography.

OBJECTIVE: To evaluate the role of computer aided detection (CAD) in improving the interpretation of screening mammograms MATERIAL AND METHODS: Ten radiologists underwent a proficiency test of screening mammography first by conventional reading and then with the help of CAD. Radiologists were blinded to test results for the whole study duration. Results of conventional and CAD reading were compared in terms of sensitivity and recall rate. Double reading was simulated combining conventional readings of four expert radiologists and compared with CAD reading. RESULTS: Considering all ten readings, cancer was identified in 146 or 153 of 170 cases (85.8 vs. 90.0%; chi(2)=0.99, df=1, P=0.31) and recalls were 106 or 152 of 1330 cases (7.9 vs. 11.4%; chi(2)=8.69, df=1, P=0.003) at conventional or CAD reading, respectively. CAD reading was essentially the same (sensitivity 97.0 vs. 96.0%; chi(2)=7.1, df=1, P=0.93; recall rate 10.7 vs. 10.6%; chi(2)=1.5, df=1, P=0.96) as compared with simulated conventional double reading. CONCLUSION: CAD reading seems to improve the sensitivity of conventional reading while reducing specificity, both effects being of limited size. CAD reading had almost the same performance of simulated conventional double reading, suggesting a possible use of CAD which needs to be confirmed by further studies inclusive of cost-effective analysis.

Breast Neoplasms↗

UKCCCR multicentre randomised controlled trial of one and two view mammography in breast cancer screening.

OBJECTIVE: To compare one view (oblique) and two view (oblique and craniocaudal) mammography in breast cancer screening. DESIGN: Randomised controlled trial. SETTING: Nine breast screening centres in England. SUBJECTS: 40,163 women aged 50-64 attending their first breast screening examination. INTERVENTIONS: Women were randomised to have one view mammography, two view mammography, or two view mammography in which one view was read by one reader and both views were read by another. MAIN OUTCOME MEASURES: Prevalence of cancer detected, recall rates, cost per cancer detected, and marginal cost per extra cancer detected. RESULTS: Two view mammography detected 24% more women with breast cancer (95% confidence interval 16% to 31%) than one view mammography. Prevalence of detected cancer was 6.84 with two view mammography and 5.52 per 1000 women with one view. The proportion of women recalled for assessment was 15% lower (95% confidence interval 6% to 23%) with two view (6.97%) than with one view (8.16%) mammography. The cost of two view screening was higher (26.46 pounds compared with 22.00 pounds per examination) but the average cost per cancer detected was similar (5330 pounds compared with 5310 pounds) and the marginal cost per extra cancer detected with two views was similar to the average cost (5400 pounds). CONCLUSION: Two view mammography is medically more effective than one view; it detects more cancers and reduces recall rates; it is also similarly cost effective financially.

Breast Neoplasms↗

Free thyroxine as a supplement to thyrotropin in cord screening for hypothyroidism.

The low specificity of cord serum T4 levels for detecting hypothyroidism, the need to reduce recall rates and the availability of a reliable and quick assay system led to this study designed to determine the advantages of using cord serum free thyroxine levels over total thyroxine levels as a supplement to cord thyroid stimulating hormone (TSH) determination. Sixty-eight out of 75 newborns with a cord TSH > 23 mU/l had both free thyroxine (fT4) and T4 levels measured in the cord serum. All were recalled within the first month of life for reevaluation of their thyroid status. In the majority of cases (46), the fT4 and T4 values corresponded. Hypothyroidism was diagnosed in eight cases; both fT4 and T4 were below the mean in five cases and above the mean in one case; only T4 was below the mean in one and in the remaining one, only fT4 was below the mean. Recall rates were 0.9% with TSH alone and 0.7% when either a fT4 or T4 level that was less than 1 sd above the mean was used as a supplement to TSH. In this cohort, using the fT4 levels instead of the T4 levels brought no change to the specificity or the sensitivity of the screening. The diagnostic sensitivity would have dropped from 100% to 75% if either T4 or fT4 values below the mean were used as a cut-off point for recall.

Congenital Hypothyroidism↗

[Neonatal screening for congenital hypothyroidism].

In Austria, neonatal screening for congenital hypothyreosis has been introduced since 1976 as a part of the national screening program for inborn errors of metabolism. Capillary blood spots are collected on filter paper from all newborns on day 3 to 5 and are subsequently investigated with a delayed fluorescence-immunoassay (DELFIA) for the determination of TSH. Since 1992 we have detected 105 patients with congenital hypothyreosis among 365,120 newborns. The recall rate of the primary TSH screening is about 0.35%. Only primary (thyroidal) hypothyreosis, but not secondary and tertiary (pituitary and hypothalamic) types of hypothyreosis are detected by the primary TSH newborn screening. As TSH is physiologically high during the first 2 days of life, the trend to early hospital discharge will result in a significant increase of the recall rate in future.

Adolescent↗

Neonatal screening for congenital hypothyroidism in West Black Sea area, Turkey.

The aim of this study was to investigate the incidence of congenital hypothyroidism (CH) in the West Black Sea Area, a mild-to-moderate iodine deficient area in Turkey. Neonatal screening for CH was performed using blood specimens collected onto filter paper. Thyrotropin [thyroid-stimulating hormone (TSH)] was measured by radioimmunoassay, and a value >20 microU/ml was considered as cut-off point for re-examining. Venous serum was obtained to measure TSH, thyroxin (T4), free T4 (FT4) and thyroglobulin (TG). To determine the iodine status of the study area, median urinary iodine was measured in 212 randomly selected neonates and their mothers. A total of 18606 neonates were screened from three cities (Bolu, Düzce, and Zonguldak) between 2000 and 2002. With a cut-off point of TSH value >20 microU/ml, the recall rate was found 1.6%. Eight cases of CH were diagnosed (incidence 1/2326). There were three cases of transient hypothyroidism, with an incidence of 1/6202. Twenty-six percent of the TSH values was greater than 5 microU/ml. Median urinary iodine concentrations in neonates and their mothers were 85 microg/l and 40 microg/l, respectively. The incidences of CH, transient hypothyroidism and the recall rate were higher in our study area than many countries in Europe. The study area has been affected by mild-to-moderate iodine deficiency. Neonatal screening for CH should be introduced in Turkey without delay. A national comprehensive infantile hypothyroidism and iodine prophylaxis policies should be developed.

Child, Preschool↗

Proficiency test for screening mammography: results for 117 volunteer Italian radiologists.

OBJECTIVE: To analyse the performance of a large sample of Italian radiologists undergoing a proficiency test for screening mammography. DESIGN: Evaluation of performance indicators according to reference standards determined by a panel of experts (sensitivity (reference standard > or = 80%), recall rate (reference standard < or = 15%)). SETTING: 117 Italian radiologists of varying experience (years of practice 0.5-18, average 5.9; mammograms read 500-51,000, average 13,000), all currently reporting clinical mammography and planning to take part in screening in the near future. RESULTS: Eighty four of 117 (72%) radiologists reached the standard for sensitivity, 88 (75%) reached the standard for recall rate, and only 59 (50%) reached both standards and passed the proficiency test. The probability of passing the test was significantly correlated with mammographic practice (p = 0.015), mammograms read (p = 0.024), and mammograms read/year (p = 0.043). DISCUSSION: The performance of a large sample of Italian radiologists currently reporting clinical mammography was disappointing, indicating the need for proper training of at least 50% of the tested subjects. When implementing organised screening the health authority should set up a proper process for training and accrediting radiologists, and a proficiency test should be part of such a process.

Chi-Square Distribution↗

A blind review and an informed review of interval breast cancer cases in the Limburg screening programme, the Netherlands.

OBJECTIVE: To investigate the proportion of interval breast cancers that could have been detected at the previous screening examination, and to gain more insight into the characteristics of these tumours. SETTING: Breast cancer screening programme in mid- and southern Limburg, the Netherlands. METHOD: Firstly, previous screening mammograms of 92 interval cancer cases were blindly reread by the radiologists from two different units as part of their daily screening workload. Secondly, a separate informed review was conducted, in which all of the cases (except for two) were subclassified into four categories: screening error; minimal signs; radiologically occult both at previous screening and at diagnosis; or radiologically occult at previous screening. Trends in recall rates and false and true positive rates were calculated to study potential changes during and after the blind review. RESULTS: In the blind review, 15% of the interval cancers were detected in both rereadings and 21% in one rereading. In the informed review, 25% were classified as a screening error and 24% as minimal signs present; 74% of the cases classified as a screening error had been recalled at least once in the blind review. Recall rates and false positive rates in daily screening practice increased significantly during and after the study period. CONCLUSIONS: About one third of the interval cancers could have been detected in the previous screening round. In order to diminish the number of avoidable interval cancers, review and classification of interval cancers is an important tool for continuing the education of screening radiologists. Therefore, further development of review training procedures is necessary.

Aged↗

Comparison of two commercial systems for computer-assisted detection (CAD) as an aid to interpreting screening mammograms.

PURPOSE: To compare the diagnostic accuracy of two commercial CAD systems (CADx and R2) and their impact as an aid to conventional reading of screening mammograms. MATERIALS AND METHODS: The image set considered consisted of 120 mammograms, 89 confirmed negative and 31 with subsequent interval cancers (11 classified as false negatives (FN), 20 as "minimal signs" (MS)). The set was digitised and processed with CAD, and printouts obtained of the mammograms with indications of the areas warranting review. Six expert radiologists read the mammograms three times, once using conventional reading and twice using CAD reading with CADx and R2, respectively. The two CAD systems were compared in terms of diagnostic accuracy of the marks and the impact of CAD reading compared to conventional reading and to the use of independent second reading simulated by combining pairs of single conventional readings. RESULTS: R2 highlighted more calcifications (218 vs 132, +65%) and CADx highlighted more masses (208 vs 105, +98%). CADx and R2 marked 15 and 17 out of 31 cancers, respectively (sensitivity 48.3% vs 54.8%, chi squared=6.4, p=0.79), 10 and 6 out of 11 FN (90.9% vs 54.5%, chi squared=2.0, p=0.15), respectively, and 5 and 11 out of 20 MS (25.0% vs 55.0%, chi squared=2.6, p=0.10), respectively. As for specificity, the false positive markings for masses were on average (per case) 1.60 for CADx and 0.75 for R2, those for calcifications were 1.08 for CADx and 1.77 for R2 and the total false positive markings were 2.68 for CADx and 2.52 for R2. CADx and R2 marked 73 and 63 of 89 negative controls (specificity = 0.18 vs 0.29, chi squared=2.52, p=0.11), respectively. All the radiologists showed greater sensitivity with CAD reading compared to conventional reading. On average, sensitivity with conventional reading was 58.6% (109/186), as against 70.9% (132/186) for CADx or R2 (chi squared=5.71, p=0.016). Sensitivity for FN cases was 71.2% (47/66) with conventional reading, 84.8% (56/66) with CADx (chi squared=2.82, p=0.09) and 80.3% (53/66) for R2 (chi squared=1.03, p=0.30) (CADx vs R2, chi squared=0.21, p=0.64). Sensitivity for MS cases was 51.6% (62/120) for conventional reading, 63.3% (76/120) for CADx (chi squared=2.88, p=0.08) and 65.8% (79/120) for R2 (chi squared=4.40, p=0.03) (CADx vs R2, chi squared=0.07, p=0.78). The recall rates were 18.1% (97/534) for conventional reading, 29.7% (159/534) for CADx (chi squared=5.72, p=0.01) and 24.3% (130/534) for R2 (chi squared=10.11, p=10-5) (CADx vs R2, chi squared=3.71, p=0.05). Double reading was significantly more sensitive than conventional reading (chi squared=29.6, p=10-6), CADx (chi squared=5.33, p=0.02) and R2 (chi squared=5.33, p=0.02). The recall rate for double reading was significantly higher than for conventional reading (chi squared=21.5, p=10-6) whereas no significant difference was detected when compared to CADx (chi squared=0.16, p=0.68) or R2 (chi squared=3.4, p=0.06). CONCLUSIONS: Despite using different algorithms, the two CAD systems exhibit comparable levels of diagnostic accuracy and a similar positive impact on sensitivity when used as an aid to conventional reading. Single reading with either CAD system is as specific but not as sensitive to double independent reading: its use as an alternative to double reading cannot be recommended and should be investigated further by means of controlled prospective studies.

False Negative Reactions↗

Recall and detection rates in screening mammography.

BACKGROUND: The authors investigated the correlation between recall and detection rates in a group of 10 radiologists who had read a high volume of screening mammograms in an academic institution. METHODS: Practice-related and outcome-related databases of verified cases were used to compute recall rates and tumor detection rates for a group of 10 Mammography Quality Standard Act (MQSA)-certified radiologists who interpreted a total of 98,668 screening mammograms during the years 2000, 2001, and 2002. The relation between recall and detection rates for these individuals was investigated using parametric Pearson (r) and nonparametric Spearman (rho) correlation coefficients. The effect of the volume of mammograms interpreted by individual radiologists was assessed using partial correlations controlling for total reading volumes. RESULTS: A wide variability of recall rates (range, 7.7-17.2%) and detection rates (range, 2.6-5.4 per 1000 mammograms) was observed in the current study. A statistically significant correlation (P < 0.05) between recall and detection rates was observed in this group of 10 experienced radiologists. The results remained significant (P < 0.05) after accounting for the volume of mammograms interpreted by each radiologist. CONCLUSIONS: Optimal performance in screening mammography should be evaluated quantitatively. The general pressure to reduce recall rates through "practice guidelines" to below a fixed level for all radiologists should be assessed carefully.

Breast Neoplasms↗

Follow-up of newborns with low thyroxine and nonelevated thyroid-stimulating hormone-screening concentrations: results of the 20-year experience in the Northwest Regional Newborn Screening Program.

OBJECTIVES: To determine the type and frequency of thyroid disorders detected in infants with low thyroxine (T4) and nonelevated thyroid-stimulating hormone (TSH) screening test results in the Northwest Regional Newborn Screening Program (NWRNSP) over the 20-year period from May 1975 to May 1995 and to determine the effect of follow-up of these infants on the overall recall rate. STUDY DESIGN: The NWRNSP requests a serum specimen in infants with an absolute T4 level < 38.6 nmol/L (< 3 mg/dl) and in infants with two filter paper T4 concentrations less than the 3%, regardless of the TSH concentration. We conducted a retrospective analysis of infants who were followed up because of low T4 and nonelevated TSH concentrations on newborn screening. To determine the effect of follow-up of infants with low T4 levels, nonelevated TSH concentrations on the recall rate, we selected 1 year (1994) for review. Serum sample requests were evaluated to determine the reason for the request. RESULTS: Over this 20-year period, the NWRNSP detected 450 infants with primary hypothyroidism among 1,747,805 infants screened (1:3,884). Of these, 416 were detected on the basis of low T4 levels and nonelevated TSH screening test results, whereas an additional 34 infants with primary hypothyroidism and 29 infants with hypopituitary hypothyroidism were detected as a result of follow-up of low T4 levels and nonelevated TSH screening test results. This included 25 infants with delayed TSH rise (1:67,226), 9 infants with mild hypothyroidism (TSH levels < 25 mU/L) (1:194,212), 29 infants with hypopituitary hypothyroidism (1:60,269), and 434 infants with T4-binding globulin deficiency (1:4,027). Excluding those with T4-binding globulin deficiency, the false-positive rate was 43.5:1. This compares with an overall false-positive rate of 12:1 for our screening program. CONCLUSION: Follow-up of infants with low T4 and nonelevated TSH concentration on screening led to the detection of 63 additional infants with hypothyroidism, for an overall frequency of 1:27,743. We believe this yield justifies continued follow-up of infants with low T4 levels, nonelevated (TSH) screening test results in our program.

False Positive Reactions↗

Mammographers' perception of women's breast cancer risk.

OBJECTIVE: To understand mammographers' perception of individual women's breast cancer risk. MATERIALS AND METHODS: Radiologists interpreting screening mammography examinations completed a mailed survey consisting of questions pertaining to demographic and clinical practice characteristics, as well as 2 vignettes describing different risk profiles of women. Respondents were asked to estimate the probability of a breast cancer diagnosis in the next 5 years for each vignette. Vignette responses were plotted against mean recall rates in actual clinical practice. RESULTS: The survey was returned by 77% of eligible radiologists. Ninety-three percent of radiologists overestimated risk in the vignette involving a 70-year-old woman; 96% overestimated risk in the vignette involving a 41-year-old woman. Radiologists who more accurately estimated breast cancer risk were younger, worked full-time, were affiliated with an academic medical center, had fellowship training, had fewer than 10 years experience interpreting mammograms, and worked more than 40% of the time in breast imaging. However, only age was statistically significant. No association was found between radiologists' risk estimate and their recall rate. CONCLUSION: U.S. radiologists have a heightened perception of breast cancer risk.

Adult↗

Mammography screening: an incremental cost effectiveness analysis of double versus single reading of mammograms.

OBJECTIVE: To compare mammography reading by one radiologist with independent reading by two radiologists. DESIGN: An observational non-randomised trial at St Margaret's Hospital, Epping. SUBJECTS: 33 734 consecutive attenders for breast screening in the main trial and a sample of 132 attenders for assessment who provided data on private costs. INTERVENTIONS: Three reporting policies were compared: single reading, consensus double reading, and non-consensus double reading. MAIN OUTCOME MEASURES: Numbers of cancers detected, recall rates, screening and assessment costs, and cost effectiveness ratios. RESULTS: A policy of double reading followed by consensus detected an additional nine cancers per 10 000 women screened (95% confidence interval 5 to 13) compared with single reading. A non-consensus double reading policy detected an additional 10 cancers per 10 000 women screened (95% confidence interval 6 to 14). The difference in numbers of cancers detected between the consensus and non-consensus double reading policies was not significant (95% confidence interval -0.2 to 2.2). The proportion of women recalled for assessment after consensus double reading was significantly lower than after single reading (difference 2.7%; 95% confidence interval 2.4% to 3.0%). The recall rate with the non-consensus policy was significantly higher than with single reading (difference 3.0%; 2.5% to 3.5%). Consensus double reading cost less than single reading (saving 4853 pounds per 10 000 women screened). Non-consensus double reading cost more than single reading (difference 19 259 pounds per 10 000 women screened). CONCLUSIONS: In the screening unit studied a consensus double reading policy was more effective and less costly than a single reading policy.

Breast Neoplasms↗

Neonatal screening program for congenital adrenal hyperplasia: adjustments to the recall protocol.

OBJECTIVE: To evaluate the influence of gestational age (GA) and birth weight (BW) on 17 alpha-OH-progesterone (17-OHP) levels with respect to their impact on the recall rate of neonatal screening programs for congenital adrenal hyperplasia (CAH). PATIENTS AND METHODS: In June 1997 we began a pilot screening program for CAH measuring 17-OHP using a fluoroimmunoassay method (DELFIA) on dried blood spots. Until September 1999, 24,153 babies were screened. Among them, we analyzed the levels of 17-OHP in 1,313 samples from healthy preterm babies (23-36 weeks) and 1,500 term babies (>37 weeks), grouped according to GA and BW. All preterm babies underwent another sampling in their 2nd week of life. RESULTS: 5 CAHs were detected. The 30-nmol/l cutoff limit for 17-OHP in blood corresponded to the calculated 99th percentile in term newborns, while in preterm babies higher levels were found. GA and BW correlated inversely with 17-OHP levels. CONCLUSION: GA and BW were useful tools to adjust cutoff levels, obtaining a significant reduction in follow-up testing and psychological stress for families. The high false-positive recall rate in preterm babies can be substantially lowered with adjusted GA and/or BW criteria.

17-alpha-Hydroxyprogesterone↗