PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Refraction, Ocular”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Effects of apomorphine, a dopamine receptor agonist, on ocular refraction and axial elongation in a primate model of myopia.

The authors examined the effect of local administration of a dopamine receptor agonist on visual deprivation-induced excessive ocular growth and myopia. Eight rhesus monkeys were monocularly deprived of vision from birth with opaque contact lenses. Four of the monkeys received drops of 1% apomorphine HCl 2-3 times/day in the occluded eye; the four control monkeys received vehicle only. Axial lengths were determined by A-scan ultrasonography at birth and at 5-7 months of age. The authors assessed the axial elongation by comparing the postnatal growth in the axial dimension of the occluded eyes with the postnatal growth in nonoccluded eyes. In three of the four control monkeys, occlusion increased axial growth by an average of 1.3 mm. In contrast, they found that growth of the occluded and nonoccluded eyes of the apomorphine-treated monkeys was equivalent, except in one monkey whose nonoccluded eye did not develop normally and was anomalously small. At 6.5-9.5 months of age, three of four controls had myopic refractive errors (-3 to -7 diopters) in the occluded eyes; three of four of the apomorphine-treated monkeys had hyperopic refractive errors (+1-(+)3 diopters) in their occluded eyes. The occluded eye of the fourth monkey was only -0.5 diopters myopic. The findings suggest that apomorphine administration retards excessive axial elongation and the concomitant development of myopia associated with visual deprivation in primates.

Administration, Topical↗

[The characteristics of conducting aviation medical expertise and dynamic medical observation of flight personnel with differing ocular refraction].

The principal techniques are systematized and implemented in examination of the visual analyser's functions in the professional aircrew. New techniques such as, for instance, visocontranstoperimetry are presented. The need for an investigation to be conducted on frequency-contrast sensitivity of the eyes is emphasized, as is continuity of methods for examination of flying personnel, beginning from troop section and ending with specialized aircraft medical centre. The authors make practical recommendations on activation and rehabilitation of the degraded visual functions in flying personnel (< > of accommodation, optico-distant blurring/obscuring, accomodoconvergentraining, autotraining of external ocular muscles and some other nontraditonal methods, prophylactic treatment with biostimulators and drug preparations aimed at improvement of metabolic processes in the visual analyzer structures, and some others).

Accommodation, Ocular↗

Changes in ocular refraction and its components among medical students--a 5-year longitudinal study.

PURPOSE: Myopic progression has been noted, especially during the period of puberty. It is interesting to investigate whether myopia will progress after the age of puberty and at what rate the changes in ocular components occur during its progression. METHODS: A 5-year longitudinal study was made of refraction and its components among 345 National Taiwan University medical students (690 eyes). The examinations included corneal curvature and cycloplegic refraction measured by auto-refractor and retinoscopy, and axial length measurement with A scan ultrasonography. The same procedures and instruments were used again after 5 years. RESULTS: The myopic prevalence increased from 92.8 to 95.8%; 21 new cases of myopia developed in the 5 years. The mean refractive error significantly increased from -4.26 +/- 2.66 D of freshmen to -4.94 +/- 2.70 D of clerks. The change in refractive error at the 5-year follow-up was 0.70 +/- 0.65 D more myopic for males and 0.54 +/- 0.64 D for females. The main change in the ocular components was in axial length, which increased from 25.54 to 26.05 mm in males and from 24.60 to 24.95 mm in females. Other optical components-including corneal curvature, anterior chamber depth, lens thickness-all remained relatively unchanged from the initial values. CONCLUSIONS: Myopia can progress after the age of puberty, but at a slower rate than during childhood. Axial elongation of the eyeball is the main component that changes in myopic progression.

Adolescent↗

Postnatal refractive development in the Brown Norway rat: limitations of standard refractive and ocular component dimension measurement techniques.

PURPOSE: The genetic tractability of the rat and its larger eye size as compared to the mouse make it an attractive model for studies of ocular development and emmetropisation. This study aimed to provide normative data in the strain of rat being used for the rat genome sequencing project whilst also evaluating standard measurement techniques. METHODS: Ocular refraction (retinoscopy, Hartinger coincidence optometry) and ocular component dimensions (keratometry, A-scan ultrasonography, calliper measures, eye weight) were measured at intervals from eye-opening to adulthood. RESULTS: There was no convincing evidence of visually guided emmetropisation during normal development. Key measurement techniques such as high-resolution A-scan ultrasonography, which work effectively in several other animal species, were unusable or inaccurate in the rat. CONCLUSIONS: This study found no evidence of emmetropisation during normal development in rat. As in mice, technical difficulties prevent accurate measurement of ocular refraction and vitreous chamber depth and may complicate tests of emmetropisation to imposed blur.

Aging↗

[Ocular refraction in Zaire].

PURPOSE: to determine frequencies of refractive errors in Zairian blacks and to investigate the influence of race upon refraction. METHODS: we examined the records of all patients seen at the department of Ophthalmology from 1963 to 1972. Refraction was measured by objective (skiascopy) or subjective methods. RESULTS: we found 4326 patients with ametropia, about 16% of the total. The records of 2594 Zairian patients with refractive errors were compared to those of 1417 non Zairian black patients and 315 Caucasian patients. The frequency of spherical refractive errors in Zairian black patients was 56%: (simple myopia: 33% myopia over 5 D: 1%, hypermetropia: 22%), astigmatism was seen in 44% (myopic astigmatism: 31% and hypermetropic astigmatism: 11%). The data of Zairian were similar to those of non-Zairian black patients. Spherical refractive errors in Caucasian patients were found in 46% of the patients (simple myopia: 19%, myopia over 5 D: 2%, hypermetropia: 25%). Astigmatismatic errors were seen in 54% (myopic astigmatism: 27%, hypermetropic astigmatism: 24%, mixed astigmatism: 3%). Hypermetropia increased with age in all groups, but slightly earlier in Zairian patients. CONCLUSION: Although the data of refractive errors did not show significant differences between Zairian and Caucasian patients, hypermetropic astigmatism seems to be less frequent and myopia more frequent among Zairian patients.

Adolescent↗

[A CT study of the relation between ocular axial biometry and refraction].

Ocular biometry in 255 eyes (131 subjects) with CT scan revealed that the length of the antero-posterior axis was 23.63 +/- 0.92 mm in hyperopia, 24.62 +/- 0.38 mm in emmetropia and 26.68 +/- 0.75 mm in myopia, and the length of the horizontal transverse axis was correspondingly 24.61 +/- 0.53 mm, 24.91 +/- 0.37 mm and 25.12 +/- 0.73 mm. There were significant differences among groups of different refractions, and the axial length increased with the severity of myopia. It was evident that refractive errors were chiefly caused by the varying axial lengths. The authors propose the parameter of the ocular diametrical ratio which is the ratio of the anteroposterior axis to the horizontal transverse axis, and accordingly hyperopia has a ratio under 1, myopia a ratio over 1 and an emmetropic eye is apparently spherical with the ratio in the vicinity of 1. The authors point out that the refractive state is determined by the ocular diametrical ratio.

Adult↗

Peripheral refraction and ocular shape in children.

PURPOSE: To evaluate the relation between ocular shape and refractive error in children. METHODS: Ocular shape was assessed by measuring relative peripheral refractive error (the difference between the spherical equivalent cycloplegic autorefraction 30 degrees in the nasal visual field and in primary gaze) for the right eye of 822 children aged 5 to 14 years participating in the Orinda Longitudinal Study of Myopia in 1995. Axial ocular dimensions were measured by A-scan ultrasonography, crystalline lens radii of curvature by videophakometry, and corneal power by videokeratography. RESULTS: Myopic children had greater relative hyperopia in the periphery (+0.80 +/- 1.29 D), indicating a prolate ocular shape (longer axial length than equatorial diameter), compared with relative peripheral myopia and an oblate shape (broader equatorial diameter than axial length) for emmetropes (-0.41 +/- 0.75 D) and hyperopes (-1.09 +/- 1.02 D). Relative peripheral hyperopia was associated with myopic ocular component characteristics: deeper anterior and vitreous chambers, flatter crystalline lenses that were smaller in volume, and steeper corneas. Lens thickness had a more complex association. Relative peripheral hyperopia was associated with thinner lenses between refractive error groups but changed in sign to become associated with thicker lenses when analyzed within each refractive error group. Receiver operator characteristics analysis of the ocular components indicated that vitreous chamber depth was the most important ocular component for characterizing the myopic eye, but that peripheral refraction made a significant independent contribution. CONCLUSIONS: The eyes of myopic children were both elongated and distorted into a prolate shape. Thinner crystalline lenses were associated with more hyperopic relative peripheral refractions across refractive error groups, but failure of the lens to thin may account for the association between thicker lenses and more hyperopic relative peripheral refractions within a given refractive group. Increased ciliary-choroidal tension is proposed as a potential cause of ocular distortion in myopic eyes.

Adolescent↗

[Correlation between refraction and ocular biometry].

PURPOSE: To study the correlation between subjective refraction and biometry obtained by Orbscan and echography in normal eyes. To compare biometric parameters with the subjective spherical equivalent. MATERIAL AND METHODS: Subjective refraction, biometric parameters using Orbscan, and echography were recorded in 190 normal eyes (including eyes with ametropia) of 95 patients. Biometric parameters (i.e., corneal diameter, anterior chamber depth, central pachymetry, iridocorneal angle, corneal and lens radii of curvature, and axial length of the eye) were compared in different refractive groups and were correlated with the subjective refraction. RESULTS: Corneal biometric parameters did not correlate with the subjective spherical equivalent and showed no differences between the refractive groups except for the central pachymetry. In the high myopic group (<-6D), the central cornea was significantly thinner (531 micro m versus 549 micro m, p=0.016). The correlation between corneal radius and axial length was strong in emmetropic eyes (r(s)=0.63, p<0.001) and poor but significant in ametropic eyes (r(s)=0.28, p=0.002). Axial length, anterior chamber depth, and iridocorneal angle showed significant differences between the refractive groups (p<0.001) and correlated with the subjective spherical equivalent (r(s[[/INF=0.44, p<0.001). Subjective spherical equivalent showed the strongest correlation with the axial length (rs)=0.82, p<0.001). Subjective spherical equivalent, central corneal thickness, axial length, anterior chamber depth, and anterior corneal radius showed a strong correlation between both eyes (rs[[/INF=0.94, p<0.001). CONCLUSION: Biometric characteristics of the eye (excluding cornea characteristics) vary with subjective spherical equivalent. Axial length presents the strongest correlation with the subjective spherical equivalent and correlates with the other ocular biometric parameters. Axial length plays a major role in the ocular biometry and refraction.

Adult↗

Heritability of myopic refractive errors in identical and fraternal twins.

The existence of a visual feedback control of eye growth in humans is controversial, as the contributions of genetic and environmental factors are still unknown. To evaluate the heritability of refractive defects, we measured ocular refraction in 19 monozygote and 20 dizygote twin pairs (mean age 5 years). Monozygosity was ascertained by a common chorion, similarity of somatic traits, and identical dermatogliphes and was confirmed in myopes by blood marker diagnosis. Ocular refractive defects and axial length were evaluated by cycloplegic autorefractometry and biometry. By comparing identical and fraternal twins heritability of refractive defects was estimated to be 0.08-0.14; this low value indicates that the observed variability in refractive errors is nongenetic in origin. Three monozygote pairs were anisomyopic; differences between eyes in identical twins were related to the increased axial length of myopic eyes. In one eye, myopia was attributed to visual deprivation induced by a congenital cataract, while in five eyes it was correlated directly to the degree of astigmatic defects. The discordant axial length observed in monozygote twins is nongenetic. In agreement with previous findings reported in the literature, it is proposed that visual impoverishment of retinal images may play an early regulatory role in postnatal eye growth.

Blood Grouping and Crossmatching↗