PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Screen Time”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Radiation dose in videofluoroscopic swallow studies.

Videofluoroscopy has become an increasingly important armament in the investigation and assessment of swallowing disorders. However, very little work has been published on the radiation dose used in such examinations and currently there is no national diagnostic reference level in the United Kingdom. Videofluoroscopy in our hospital is performed predominantly by one radiologist (IZM) in a single fluoroscopy room. We recorded the screening times of 230 patients over a 45-month period. Screening time ranged from 18 to 564 s (median = 171 s) associated with a median dose-area product of 1.4 Gy cm(2). This is below the third quartile level of 2.7 Gy cm(2) for all such examinations performed across the northern England. The effective dose associated with a typical videofluoroscopy dose-area product is 0.2 mSv. Videofluoroscopy is the most appropriate instrumental examination for assessing oropharyngeal swallow biomechanics and intervention strategies. This data set is based on the largest number of videofluoroscopy swallow studies published to date. Our results show that videofluoroscopy can be performed using minimal radiation doses.

Adolescent↗

The post-aspirin bleeding time: a screening test for evaluating haemostatic disorders.

To evaluate the usefulness of the template bleeding time post-aspiring ingestion, this test was performed with other tests of haemostasis in 28 controls and 71 patients. The mean bleeding time (B.T.) in 24/28 true controls was 3.5 +/- 1 min (1 SD). Following the ingestion of 600 mg aspirin the B.T. was 6.3 +/- 1.4 min. Four out of 28 false 'controls' with negative bleeding histories were documented to have asymptomatic von Willebrand's disease and abnormal post-aspirin B.T. Of the 71 patients studied, 22 had initial B.T. that were abnormal (16 with classical von Willebrand's disease and six with platelet dysfunction). Of the remaining 49 patients with initially normal B.T., 30 had abnormal post-aspirin B.T. Of these 30 patients 13 had von Willebrand's disease. In eight, initially the abnormal B.T. post-aspirin was the only abnormality demonstrable but later they were shown to have von Willebrand's disease. In four the abnormal post-aspirin B.T. was combined with abnormal Ristocetin aggregations and a positive family history. These patients were presumed to have a variant of von Willebrand's disease. The remaining five had platelet dysfunctional states. Of the 19 patients with normal initial post-aspirin B.T., 16 demonstrated no haemostatic abnormality, and three were proven to have von Willebrand's disease. The aspirin tolerance test raised the sensitivity of the B.T. as a screening test for haemostasis from 40% to 94% in the abnormal patient population.

Adolescent↗

Crude open biopsy rates for benign screen detected lesions no longer reflect breast screening quality--time to change the standard.

OBJECTIVES: To investigate the changing nature of the benign screen detected breast abnormalities removed at open biopsy over a seven year period and to compare this with the improving cancer detection rate and non-operative diagnosis rate. SETTING: The Bolton, Bury, and Rochdale Breast Screening Programme. METHODS: The histopathology reports of the benign lesions removed from patients undergoing open biopsy for screen detected abnormalities between 1 April 1994 and 31 March 2001 were reviewed and the lesions classified on the B1 to B5 scale. Cancer detection rates and non-operative cancer diagnosis rates were ascertained from the breast screening computer system. RESULTS: 148 benign surgical biopsies were performed in the seven year period. There was a moderate increase in the overall benign biopsy rate over the period (from 1.26 open biopsies per 1000 women screened for the three years 1994-97 to 1.63 open biopsies per 1000 women screened for the three years 1998-2001). The biopsy rate for B2 (benign) lesions decreased slightly over the study period but the biopsy rate for B3 lesions (that is, of uncertain malignant potential) more than doubled. The majority (84%) of the B3 lesions were radial scars. There was a steady improvement in the cancer detection rate and the non-operative cancer diagnosis rate over the period, similar to that seen nationally. CONCLUSIONS: Improvements in screening technique and detection ability result in an increase in the number of subtle radiologically indeterminate or suspicious lesions detected. Many of these are radial scars, which require excision. Crude benign open biopsy rates for screening programmes are no longer meaningful, and should now be refined with separate rates for B2 lesions and B3 lesions. High quality programmes can expect to have low B2 open biopsy rates and high B3 open biopsy rates. It is inappropriate to have an upper limit for the B3 open biopsy rate.

Biomarkers↗

Obstacles to timely neonatal screening in North Thames.

OBJECTIVE: To assess the timeliness of neonatal (Guthrie card) screening in North Thames, and to identify the most effective ways of improving it. DESIGN: Analysis of information routinely collected in the course of neonatal screening; reanalysis of published data on blood phenylalanine concentration in phenylketonuria (PKU) over the first two weeks; simulation studies on the impact of different interventions. SUBJECTS: 100,690 infants born over one year and screened at Great Ormond Street Hospital NHS Trust. OUTCOME MEASURE: Interval between birth and reading PKU screen results. RESULTS: Although 75% of samples (district range 55-91%) were collected by day 7, only 81% had arrived in the laboratory seven days later (range 57-96%). The average interval between birth and reading results was 14.5 days, with only 9.7% read by day 10. Samples could be collected from day 4 without significant impact on false negative rates for PKU. If samples were collected from day 4 and posted promptly (second class), the average interval between birth and reading results could be reduced to 9.3 days. If first class mail were used and the laboratory operated on Saturdays, and used assays that could be read the same day rather than bacterial inhibition assays, the average would be 7.8 days, with 96% read by day 10. CONCLUSION: Timeliness of neonatal screening shows unacceptable variation between districts, and delays in dispatch of specimens to the laboratory. Same day, first class posting should be introduced, and samples could be collected between days 4 and 8.

Blood Specimen Collection↗

Axillary artery approach for balloon valvoplasty in young infants with severe aortic valve stenosis: medium-term results.

OBJECTIVES: To assess the feasibility and results of trans-axillary approach for balloon aortic valvoplasty (BAV) in early infancy. BACKGROUND: Severe aortic valve stenosis (SAVS) is rare but serious condition in infancy, which may be promptly treated either by surgical aortic valvotomy or BAV. BAV is usually performed via the femoral artery route, which is associated with significant vascular complications and long procedure times. METHODS: BAV via the trans-axillary approach was performed on twenty-seven sequential infants with SAVS presenting to a single tertiary referral center over an 11-year period. Maximum inflated balloon size was less than or equal to the aortic valve diameter. RESULTS: Twenty-seven infants aged 1-77 days underwent BAV. Weight at time of procedure was 2.0-4.42 kgs. The median procedure and screening times were 82 and 7.9 minutes, respectively. Mean instantaneous Doppler gradient across the aortic valve reduced from 68 +/- 33 to 37 +/- 14 mmHg ( p < 0.0001). Three infants developed at least moderate aortic regurgitation. Right arm pulse volume was decreased in 12 infants; 5 received an intravenous heparin infusion. Longer-term follow-up demonstrated reduced or absent peripheral pulse in 5 infants. Transection of the axillary artery occurred in one infant requiring emergency microvascular repair. There was one post-procedural and one late death due to non-cardiac causes. CONCLUSIONS: In early infancy balloon aortic valvoplasty via the axillary artery approach for severe aortic stenosis is an acceptable and safe alternative to the femoral arterial approach and results in short procedure and screening times. Longer-term vascular follow-up is required. (c) 2006 Wiley-Liss, Inc.

Aortic Valve Stenosis↗

Pediatric Amblyopia Risk Investigation Study (PARIS).

PURPOSE: To assess the learning curve, testability, and reliability of vision screening modalities administered by pediatric health extenders. DESIGN: Prospective masked clinical trial. METHODS: Two hundred subjects aged 3 to 6 underwent timed screening for amblyopia by physician extenders, including LEA visual acuity (LEA), stereopsis (RDE), and noncycloplegic autorefraction (NCAR). Patients returned for a comprehensive diagnostic eye examination performed by an ophthalmologist or optometrist. RESULTS: Average screening time was 5.4 +/- 1.6 minutes (LEA), 1.9 +/- 0.9 minutes (RDE), and 1.7 +/- 1.0 minutes (NCAR). Test time for NCAR and RDE fell by 40% during the study period. Overall testability was 92% (LEA), 96% (RDE), and 94% (NCAR). Testability among 3-year-olds was 73% (LEA), 96% (RDE), and 89% (NCAR). Reliability of LEA was moderate (r = .59). Reliability of NCAR was high for astigmatism (Cyl) (r = .89), moderate for spherical equivalent (SE) (r = .66), and low for anisometropia (ANISO) (r = .38). Correlation of cycloplegic autorefraction (CAR) with gold standard cycloplegic retinoscopic refraction (CRR) was very high for SE (.85), CYL (.77), and moderate for ANISO (.48). CONCLUSIONS: With NCAR, physician extenders can quickly and reliably detect astigmatism and spherical refractive error in one-third the time it takes to obtain visual acuity. LEA has a lower initial cost, but is time consuming, moderately reliable, and more difficult for 3-year-olds. Shorter examination time and higher reliability may make NCAR a more efficient screening tool for refractive amblyopia in younger children. Future study is needed to determine the sensitivity and specificity of NCAR and other screening methods in detecting amblyopia and amblyopia risk factors.

Amblyopia↗

Radiation dosage during AO locking femoral nailing.

Radiation dosages to both the patient and the surgeon were measured during 10 consecutive AO locking nail procedures. The total screening time for each procedure averaged 12 min 8 s; the average screening time for distal locking was 6 min 52 s. Radiation dosages to surgeons' hands, thyroid and gonads and to the patients were well within permitted safety levels.

Bone Nails↗

Screening for dementia by telephone using the memory impairment screen.

OBJECTIVES: : To develop and assess telephone-based screening tests for dementia, especially Alzheimer's disease (AD). DESIGN: : A cross-sectional validation study nested within a longitudinal study of aging and dementia. SETTING: : The Einstein Aging Study of the Albert Einstein College of Medicine, Bronx, New York. PARTICIPANTS: : Three hundred elderly community volunteers living in Bronx County, 27 of whom were diagnosed with dementia based on in-person clinical evaluation. Of the 27 individuals with dementia, 18 had AD. MEASUREMENTS: : A telephone battery was administered that included the Memory Impairment Screen by telephone (MIS-T, a test of semantic memory), the Category Fluency Test (CF-T), and the Telephone Instrument for Cognitive Status (TICS). An in-person evaluation then followed that included a neurological examination, a neuropsychological battery, demographics, and medical history. RESULTS: : The telephone battery was well accepted. The MIS-T required 4 minutes; the CF-T, 3 minutes; and the TICS, 10 minutes. The MIS-T had excellent sensitivity and specificity when compared with the CF-T and the TICS. Using cutscores on all three tests that provide a sensitivity of 78%, specificity was significantly higher for the MIS-T (93%) than for the CF-T (78%, P<.05) or the TICS (80%, P<.05). Combining the MIS-T and CF-T improved discriminative validity but increased screening time and the complexity of scoring. Normative data for the MIS-T, the CF-T, and the TICS for use in settings with different base rates (prevalence) of dementia are presented in this study. CONCLUSION: : The MIS-T outperforms the CF-T and the TICS as a valid and time-efficient telephone screen for dementia. For applications that require optimal efficiency and accuracy, the MIS-T is recommended.

Aged↗

Evaluation of a centrifuge method and thin-layer preparation in urine cytology.

OBJECTIVE: To evaluate and compare the quality and cost of urine cytology using the Cytospin method (Shandon, ThermoElectron Corporation, Waltham, Massachusetts, U.S.A.) and the AutoCyte PREP (TriPath Imaging, Burlington, North Carolina, U.S.A.) in a general laboratory. STUDY DESIGN: A study of differences between the Cytospin method and AutoCyte PREP in the areas of specimen preparation, staining, number and quality of diagnostic cells, background, screener preference, and cost was undertaken over a 3-month period in 2000. Sixty fresh voided urine samples from 25 patients with known transitional cell carcinoma were prepared by the Cytospin method and the AutoCyte PREP according to the manufacturers' instructions. RESULTS: The Cytospin method had longer preparation time but shorter screening time than the AutoCyte PREP. The number of diagnostic cells was higher in the Cytospin method. Fixation quality and staining clarity were better in the Cytospin method. Qualitative assessment of cell arrangements, cell and nuclear size and shape, nuclear/cytoplasmic ratio and nuclear membrane irregularity showed no significant differences between the 2 methods. Cellular details and nuclear chromatin patterns were clearer and better preserved in the Cytospin method, but the AutoCyte PREP showed less blood and inflammatory cells and debris. CONCLUSION: In the majority of cases the screeners preferred the Cytospin method due to its better overall cytologic quality. However, the amount of blood, inflammation and debris was much lower in the AutoCyte PREP. This reduced the need to make a second, diluted specimen and made turnaround time faster. The AutoCyte PREP was 7 times more expensive than the Cytospin method.

Carcinoma, Transitional Cell↗

Attendance patterns and characteristics of participants in public cholesterol screening.

We conducted free, voluntary, public cholesterol screenings in supermarkets in the Rochester, New York, area during a four-month period for demonstration and research purposes. We assessed demographic characteristics and attendance patterns of the 8,583 participants. Compared with 1980 census data for the same census tracts, our participants were likelier to be white, older, female, and better educated than the general population in the area. Most screenees knew about the screenings in advance, and 79% came to the store just for screening. Weekend and weeknight screenings attracted more men and more younger people, in comparison to weekday screenings. However, referral rates based on high cholesterol (HC) test results were similar during all screening times. Overall, 22% of screenees reported a previous diagnosis of HC, but in the highest cholesterol-level group, 45% of screenees reported a history of HC. Previous awareness of HC did not vary according to screening time. These findings indicate that, like other screenings, cholesterol screenings in a public setting do not attract a representative sample of the whole population. The screenings did, however, attract a large number of high-risk individuals, many of whom had no prior awareness of HC. These results should be valuable in planning and targeting future cholesterol screenings.

Adult↗

Evaluation of polyp detection in relation to procedure time of screening or surveillance colonoscopy.

BACKGROUND AND OBJECTIVES: Multiple factors influence the yield of colonoscopy for the detection of neoplasia. Few studies have addressed the impact of colonoscopy duration on procedure yield. The aim of our study was to determine whether endoscopist-specific procedure times correlate with the number and clinical significance of polyps detected at screening or surveillance colonoscopy. METHODS: Procedural data from screening or surveillance colonoscopies performed at Mayo Clinic, Rochester MN, between January 1, 1996 and June 30, 2000, were reviewed. Individual endoscopists were characterized by their personal endoscopist procedure mean time (EPMT) to perform a negative colonoscopy. Procedure time included patient's consent and sedation. EPMT was then correlated with individual polyp detection rates. RESULTS: Overall, 10,159 colonoscopies were reviewed of which 4,312 (42.4%) yielded polyps. Polyp detection varied among endoscopists between 19.0% and 62.3%. There was a close correlation between EPMT and polyp yield (all sizes), r = 0.64, although correlation was weaker for polyps >10 mm (r = 0.42) and polyps >20 mm (r = 0.20). On multivariate analysis, longer mean endoscopist time was associated with colonic lesion detection, OR = 1.54 (95% CI 1.37-1.62). Longer mean procedure duration demonstrated a looser association with identification of polyps >10 mm, OR = 1.40 (1.19-1.64) and polyps >20 mm, OR = 1.03 (0.74-1.43). CONCLUSIONS: There is a direct correlation between colonoscopy procedure time and yield, with a three-fold variation of polyp detection rates. These results should prompt future prospective studies assessing the impact of colonoscopic withdrawal time on lesion detection.

Colonoscopy↗

Comparative study: conventional cervical and ThinPrep Pap tests in a routine clinical setting.

The conventional Papanicolaou smear is associated with variable false positive and false negative rates, difficulties with interpretation and high unsatisfactory and suboptimal rates. Newer fluid-based methods such as the ThinPrep 2000 system (Cytyc Corp., Boxborough, MA) are said to overcome these difficulties. The aim of this study was to compare the conventional smear with the ThinPrep method in a busy, routine cytology screening laboratory setting. One thousand split samples were evaluated. Using ThinPrep, the results showed an increased sensitivity and a dramatic improvement in specimen adequacy, with a combined 17.2% reduction in 'unsatisfactory' and 'suboptimal' reports. Screening time per slide was also reduced to 3-4 min. In conclusion, we report an increase in sensitivity, a reduction in screening time and a dramatic improvement in specimen adequacy with the ThinPrep method.

Cell Nucleus↗