PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Shear Strength”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Shear strength of the physis varies with anatomic location and is a function of modulus, inclination, and thickness.

Slipped capital femoral epiphysis involves the gradual displacement of the femoral head relative to the neck. Many theories have arisen to explain this slip. Frequently cited etiological factors include increases in physeal thickness and inclination. Slipped epiphysis has been postulated to result from shear overload that causes separation through the hypertrophic cellular zone. We sought to answer the following questions: (a) Do significant regional differences in strength and stiffness exist within a given physis? (b) Are regional differences in resistance to shear related to thickness and inclination of the physis? (c) Does physeal compression cause mammillary interdigitation to begin sooner and increase the resistance to shear before, during, and after failure? (d) Does shear failure occur at displacements detectable by radiography? and (e) Does cleavage occur throughout the entire columnar zone, and do the chondrocyte columns remain intact on both sides of the cleavage plane? We prepared beam-shaped microstructural samples from different sites of the bovine proximal tibial physis. We determined thickness, inclination, ultimate stress and strain, modulus, and strain energy density at ultimate stress as a function of location. Using scanning electron microscopy, we also examined the entire failed surface of several samples. Forty-eight samples were tested by displacing the epiphysis end anteriorly, without axial (across the thickness) constraint; 41 were sheared while an average axial compressive stress of 0.3 MPa was applied to the physis. The posterior region had the greatest strength and stiffness, lowest physeal thickness, and steepest inclination. Compressing the plate did not increase the shear strength or tangent modulus. Ultimate strength varied inversely with thickness and increased when shearing up steeper inclinations; however, it was more strongly associated with the modulus, implying that additional factors control both strength and modulus. Scanning electron microscopy revealed that the plane of fracture differed widely between and within samples, involving all zones of the growth plate. On either side of the fracture, individual chondrocyte columns remained intact, although separated from neighboring columns.

Animals↗

[Testing metal/acrylic bonds for shear strength, axial tensile strength and maximum bending stress].

The effects of thermocycling and water penetration on the bond strength of resin-metal-systems and improvements using bonding agents have been tested by shear, bending and tensile tests. After 10,000 cycles within 10 days in different water-baths with 5-37-55 degrees C, there is a decrease in bond strength by 40 to 60%. The use of bonding agents increases the adhesion of the resin to the metal by more than 100%. No significant differences were found between the three bonding agents Silicoater, Sebond MKV and OVS.

Acrylic Resins↗

[Study on the mechanical properties of quartz fiber-reinforced composite for canal post].

PURPOSE: To study the mechanical properties of custom-made quartz fiber-reinforced epoxy resin composite for prefabricated post. METHODS: Composite rods of 5 experiment groups with different fiber contents were made of quartz fiber and epoxy resin.Flexural strengths, shear strengths and fiber contents were measured, corresponding elastic modulus were calculated, cross-section surface and fracture surface was viewed under SEM. Statistical analysis was carried out with one way analysis of variance(ANOVA) and Student-Newman-Keuls for the experimental groups. RESULTS: The flexural strength of composite rods increased with the increase of fiber content, within the limitations of this research, the flexural strengths ranged from 741 to 1165 MPa, corresponding fiber contents ranged from 53.3 to 78.6 Wt%, corresponding flexural strengths ranged from 36.7 to 50.4 MPa,corresponding elastic modulus ranged from 30.6 to 51.9 GPa, SEM showed that fiber distribution in resin was uniform, there was good adhesion between fiber and epoxy resin. ANOVA revealed significant differences of flexural strengths and shear strengths between the experimental groups and control group (P<0.01), Student-Newman-Keuls analysis showed significant differences of flexural strengths and shear strengths between the experimental groups(P<0.01). CONCLUSION: The custom-made quartz fiber-reinforced epoxy resin composite can be used for prefabricated post with good mechanical properties.

Composite Resins↗

[Binding of the von Willebrand factor to solid surfaces: effect of shear strength].

Platelet adhesion onto subendothelium of a damaged blood vessel depends upon the presence of von Willebrand factor (vWf) only at high flow shear rate. Our results showed enhanced adsorption of vWf onto stainless steel and latex surfaces under conditions of high shear stress, thus suggesting that in the rapidly flowing blood the extremely long vWf molecules are stretched, thus accelerating their binding to a given surface.

Factor VIII↗

Early uncovering of HA-coated cylinder implants: case report of an in vivo shear strength test.

A new approach was used to test the readiness of an HA-coated implant for commencement of prosthetic procedures after two months of bone healing in humans. A torquing device was used for clinical measurement of the shear resistance of the supporting bone. It was found that the bone was capable of resisting a shear force just slightly greater than that which was necessary to produce displacement of implants placed in dog femurs with a comparable bone-healing period and with healing to full maturity. This report suggests that it may be feasible to uncover HA-coated implants after two months of bone healing.

Dental Implants↗

Shear strength of composite bonded to Er:YAG laser-prepared dentin.

An Er:YAG laser coupled with a cooling stream of water effectively removes dental hard tissues. However, before such a system can be deemed clinically viable, some safety and efficacy issues must be addressed. We compared the bonding of composite to dentin following the preparation of the dentinal surface with either an Er:YAG laser (lambda = 2.94 microns) or a standard dental bur and with and without a subsequent acid-etching treatment. The crowns of extracted human molars were removed, revealing the underlying dentin. We removed an additional thickness of material with either a dental handpiece or an Er:YAG laser (350 mJ/pulse at 6 Hz) by raster-scanning the samples under a fixed handpiece or laser. Comparable surface roughnesses were obtained. Several samples from each group received an acid-conditioning treatment. A cylinder of composite was bonded onto the prepared surfaces. The dentin-composite bond was then shear-stressed to failure on a universal testing apparatus. The results indicate that laser-irradiated samples had improved bond strengths compared with acid-etched and handpiece controls. SEM photographs of the surfaces show exposed tubules following the laser treatment: tubules could also be exposed with acid etching. We conclude that Er:YAG laser preparation of dentin leaves a suitable surface for strong bonding or an applied composite material.

Acid Etching, Dental↗

Compressive shear strength of core materials and restoring techniques.

In this study, ninety extracted endodontically treated mandibular molars were mounted in acrylic resin blocks. Five groups of eighteen extracted teeth were prepared by two different techniques. A peripheral shelf 2 mm deep and 1.4 mm wide was prepared as a first technique, while TMS pins were used in the second group. The teeth were then restored with five different core materials: silver-reinforced glass-ionomer, resin-modified glass-ionomer, self-cured glass-ionomer, polyacid-modified composite resin, and titanium-reinforced composite resin. An Instron testing machine was used to apply shear force at a crosshead speed of 2 mm/min until fracture occurred. The results were obtained statistically using analysis of variance and least significant difference tests. According to the results of this study, Ti-core and composite resin were the strongest core materials when subjected to shear forces, and the most retentive preparation design was the vertical-pin design. The fractures of these materials with a vertical-pin design were mostly seen at the core and the tooth.

Analysis of Variance↗

Shear strength of lingual rest seats prepared in bonded composite.

A study based on the single criterion of resistance to loading forces was conducted to investigate the suitability of lingual composite rest seats for anterior teeth. The minimum acceptable resistance level was chosen from a review of the literature; other basic criteria were described; and the desirability of this technique was discussed.

Composite Resins↗

The effect of radiation on the shear strength of acrylic bone cement.

Bone loss due to secondary neoplastic disease of bone has frequently presented the orthopedic surgeon with difficult or insoluble problems of surgical management. Local radiation is the most effective, and widely used form of therapy for this type of metastatic disease. Levels of radiation in vitro comparable to therapeutic doses, as well as levels 6 times that commonly used in vivo on patients, demonstrate no significant effect on the mechanical properties of acrylic bone cement.

Acrylic Resins↗