[The algae toximeter for continuous water monitoring].
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Fifty six patients (52 males, 4 females, mean age 53.6 +/- 8 years, range 35-75 years) were studied to determine the influence of clinical variables, site of myocardial infarction, thrombolytic therapy, documented arrhythmias and left ventricular ejection fraction (LVEF) on the incidence of ventricular late potentials (LP's). LP's were detected in 17 (30.3%) patients; in 6 (26%) patients with acute and in 11 (33.3%) patients with old healed myocardial infarction. 87.5% of the patients in whom LPs were detected had low LVEF. The presence of low LVEF correlated significantly with the presence of LP's (p = .02). LP's were also present in all patients with documented sustained ventricular tachycardia. Clinical variables (Killip and NYHA class), site of myocardial infarction, Q wave versus non-Q wave myocardial infarction and thrombolytic therapy did not relate to the presence of LP's (p > 0.5) Patients of myocardial infarction with low LVEF and a history of ventricular tachyarrhythmias should undergo signal averaged electrocardiography for LP detection. LP presence would identify patients at higher risk of future arrhythmic events within this subgroup.
Explore the source record for details and available documents.
Studies have been made on the development of the spontaneous bioelectrical activity in the brain of 13-21-day chick embryos and on the reactions of the brain to sonic and photic stimulation (single and rhythmic). It was shown that the onset of the evoked responses to afferent stimulation coincides with predominance of a periodic process in the bioelectrical activity (17-18th days of embryogenesis). The presence of ordered rhythmicity in the bioelectrical activity of the brain which coincides with a possibility of its transformation and synchronization with afferent stimuli is suggested to be an important index of the development of the brain.
In implementing time-orientated medical record (TOMR) management systems, use of a relational model played a big role. Many applications have been developed to extend query and data manipulation languages to temporal aspects of information. Our experience in developing TOMR revealed some deficiencies inside the relational model, such as: (a) abstract data type definition; (b) unified view of data, at a programming level; (c) management of temporal data; (d) management of signals and images. We identified some first topics to face by an object-orientated approach to database design. This paper describes the first steps in designing and implementing a TOMR by an object-orientated DBMS.
Objective.The trade-off between detection sensitivity and spatial resolution is a fundamental challenge in designing organ-dedicated Single-photon emission computed tomography (SPECT) collimators. While converging-hole geometries offer a solution, their optimization is often hindered by the lack of flexible computational tools capable of modeling large-scale, non-parallel hole arrays. This study aims to develop an automated geometric modeling framework to facilitate the design and evaluation of complex converging- and diverging-hole collimators within standard Monte Carlo environments.Approach.We developed a specialized modeling framework by implementing custom C++ classes and a vector-based alignment algorithm within GATE. This platform enables automated, orientation-consistent construction of large-scale converging arrays not natively supported by standard implementations. A high-sensitivity pure cone-beam collimator (CBC) was designed using this framework. The evaluation used hot-rod, disc, and Jaszczak phantoms for physical characterization, while XCAT and dedicated brain models were employed for clinical tasks, including cardiac, brain perfusion, and DaTscan SPECT simulations.Main results.The CBC achieved a nearly fourfold sensitivity increase compared to a conventional low-energy high-resolution parallel-hole collimator at a 20 cm radius of rotation, while maintaining comparable spatial resolution. Despite a 52.3% field of view reduction, the CBC yielded a 2.2-fold noise reduction (CV: 11.7% vs 25.9%) and mitigated partial volume effects via geometric magnification. XCAT and brain phantom simulations confirmed enhanced anatomical definition and contrast recovery in cardiac, perfusion, and DaTscan tasks.Significance.This work provides an efficient computational tool for rapid design space exploration of advanced collimator geometries. The results demonstrate that the proposed CBC design offers a significant sensitivity advantage, making it highly suitable for high-performance, small-volume clinical applications such as brain and cardiac molecular imaging.
A sequence motif complementary to the nuclear localization signal (NLS) has been localized in proteasomes from Thermoplasma acidophilum by immunoelectron microscopy using sequence-specific antibodies. The antibodies were generated in two different ways: by immunization with a carrier-coupled peptide and by isolation of the sequence-specific antibody from an immune serum against native proteasomes using a peptide-affinity column. The sequence specificity of the isolated antibody was confirmed by a PEPSCAN-ELISA performed on overlapping nonapeptides deduced from the sequence of the alpha-subunit of the Thermoplasma proteasome. Compared to the antibody induced by the carrier-coupled peptide this antibody fraction showed a much higher affinity for native proteasomes. The attachment site of the Fab portion of the antibody to the proteasome was mapped by electron microscopy in conjunction with image processing. The antibody was found to bind to the periphery of the two outer "disks" of the proteasome complex formed by the alpha-subunits.
The increasing importance of electrocardiogram (ECG) interpretation by computers warrants consideration of the specific technical requirements for ECG recorders used in computer-assisted ECG interpretation systems. An almost uniform characteristic of these devices is their capability to transmit the ECG signal over common carrier lines. This paper suggests minimum performance characteristics for the different components of a teletransmitting ECG recorder to facilitate the use and evaluation of computer-assisted interpretation systems. Considered are the need for signal fidelity, features for automatic quality control, and features for patient and technician safety. The performance characteristics for the ECG amplifier are only stated where they exceed the most recent recommendations of the Committee on Electrocardiography, American Heart Association. The features of the teletransmission section are based on a widely used mode and format of transmission.
Routine monitoring of a bipolar atrial electrogram (AEG) simultaneously with the electrocardiogram is a useful and safe clinical technique for the diagnosis of complex cardiac dysrhythmias. The large-amplitude A waves of the AEG can be more reliably identified than the corresponding low-amplitude p waves of the electrocardiogram. Epicardial wires placed during cardiac surgery, catheter-mounted endocardial electrodes, and esophageal electrodes can all be used for routine AEG monitoring. A multipurpose pulmonary arterial catheter with a pair of electrodes, and esophageal electrodes can all be used for routine AEG monitoring. A multipurpose pulmonary arterial catheter with a pair of electrodes mounted on the proximal shaft can be used for combined AEG and hemodynamic monitoring. The equipment needed for AEG monitoring and recording consists of an additional bedside amplifier with 12- to 100-Hz band-pass filter, a dual-channel display scope, and a dual-channel strip chart recorder. Care must be used to keep the atrial electrodes electrically isolated for patient safety. In addition to enhancing the diagnosis and management of dysrhythmias, recording an AEG provides a signal that is suitable for automatic processing.
To prevent damage to the host or its commensal microbiota, epithelial tissues must match the intensity of the immune response to the severity of a biological threat. Toll-like receptors allow epithelial cells to identify microbe associated molecular patterns. However, the mechanisms that mitigate biological noise in single cells to ensure quantitatively appropriate responses remain unclear. Here we address this question using single cell and single molecule approaches in mammary epithelial cells and primary organoids. We find that epithelial tissues respond to bacterial microbe associated molecular patterns by activating a subset of cells in an all-or-nothing (i.e. digital) manner. The maximum fraction of responsive cells is regulated by a bimodal epigenetic switch that licenses the TLR2 promoter for transcription across multiple generations. This mechanism confers a flexible memory of inflammatory events as well as unique spatio-temporal control of epithelial tissue-level immune responses. We propose that epigenetic licensing in individual cells allows for long-term, quantitative fine-tuning of population-level responses.
Analogue transmission of biomedical signals over the public telephone network has advantages from the economic point of view over digitalized transmission. This paper deals with the special problems encountered with the transmission of biomedical signals. Furthermore, the new international transmission standard C.C.I.T.T. recommendation V. 16 is introduced. This standard has recently been adopted by the relevant study group and has been presented to the Plenary Assembly of the C.C.I.T.T. for final approval. This standard is compatible with the existing public telephone networks. The technical specifications of this standard allow the transmission of the three-channel ECG for diagnostic purposes, e.g., remote processing and computer-assisted evaluation, as well as the transmission of the one-channel ECG with acoustic coupling, e.g., in emergency cases and for pace maker monitoring.
MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.
A measuring place is described for the registration of standardized, evaluable by means of the computer deviations of bioelectric signals (parameters of heart and circulation, peripheral pulse curves and rheogramms). The high demands which concern the adequate establishment measuring places with regard to quality and comfort of attendance and condition corresponding technical solutions are explained. At the instance of the rheogram the mode of function is described. A short prognosis on the trend of development in the recognition of biological measuring values is given.
Successful and adequate external recording of the cardiac conduction system from the body's surface can be accomplished in 80 to 90 percent of subjects studied. High-gain amplification, signal averaging, and triggering with a conditioned QRS signal results in good recording reproducibility. Averaging of 128 consecutive cycles is adequate, but on occasion averaging of 256 cycles may yield better results. The patients's QRS signal triggers the transfer of signals, which are digitized and stored during the preceding P-R interval. Comparison of external recordings with direct invasive recordings in animals and patients shows good correlation between the major His bundle deflections. The advantages of the system developed include its mobility, triggering the QRS with pretrigger data processing, and instantaneous display on Polaroid photograph. Future research should concentrate on further miniaturization and simplification of the instrumentation, detailed experimental comparison between direct and external recordings for identification of deflections and their origin, further study of the recording lead system, and the most appropriate method of information display.
A digital computer system is described which allows the real-time processing of all physiological signals obtained during a heart catheterization procedure and which makes all relevant results and informations available immediately during the investigation. In addition, special electronic units and programs have been developed in our institution for the automated extraction of morphological criteria from biplane angiocardiograms. Thereby right and left ventricular volume, shape and contraction pattern can be quantitated and used to characterize the performance of the heart as muscle and pump in physical terms. Recently, complete digital processing of videoangiocardiograms has been achieved in a stroboscopic mode, each videofield in real time. Application of image enhancement, subtraction, integration and restoration techniques leads to a fundamentally improved angiocardiographic image quality for a given amount of injected contrast material. Based on eight years of experience with digital computer application in pediatric cardiology, computer technologies are considered likely to become the method of choice in the future.