PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Spectrometry, Fluorescence”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Determination of methylmercury in human hair by ethylation followed by headspace solid-phase microextraction-gas chromatography-cold-vapour atomic fluorescence spectrometry.

An analytical procedure for the determination of methylmercury in human hair after acid digestion using aqueous ethylation, headspace solid-phase microextraction sampling and final gas chromatography-cold-vapour atomic fluorescence spectrometry detection is described. Acid digestion, extraction procedure and chromatographic conditions were optimised. An optimal linear range using standard mercury solutions was found and concentration detection limits for the mercury species, MeHg and Hg2+, were about 50 and 80 ng/g, respectively, for 100 mg of human hair. The reproducibility of the developed analytical procedure assessed for hair samples with incurred MeHg was better than 18% (n=5). A certified reference material from the National Institute of Environmental Studies (Japan) was used for validation. Analysis of human hair collected from urban inhabitants was performed and the mean value of methylmercury content in hair samples was 0.764 +/- 0.732 microg/g for the population tested. The developed analytical method is simple, fast and a suitable procedure for the monitoring and screening of human exposure to methylmercury.

Chromatography, Gas↗

Capillary electrophoresis on-line coupled with hydride generation-atomic fluorescence spectrometry for speciation analysis of selenium.

A new method for speciation analysis of two inorganic selenium species was developed by on-line coupling of capillary electrophoresis (CE) with hydride generation-atomic fluorescence spectrometry (HG-AFS) and on-line conversion of Se(VI) to Se(IV). Baseline separation of Se(VI) and Se(IV) was achieved by CE in a 50 cm x 75 microm inside diameter (ID) fused-silica capillary at -20 kV using a mixture of 15 mmol.L(-1) NaH2PO4 and 0.5 mmol.L(-1) cetyltrimethylammonium bromide (pH 7.5) as electrolyte buffer. Se(VI) was on-line reduced to Se(IV) by mixing the CE effluent with concentrated HCl. The precision (relative standard deviation, RSD, n=7) ranged from 0.7 to 1.3% for migration time, 6.4 to 3.7% for peak height response, and 5.9 to 6.1% for peak area for the two selenium species at the 500 microg.L(-1) (as Se) level. The detection limits were 33 and 25 microg.L(-1) (as Se) for Se(VI) and Se(IV), respectively. The recoveries of the two selenium species in five locally collected water samples ranged from 88 to 114%. The developed method was applied to speciation analysis of inorganic selenium species in spiked natural water samples.

Electrophoresis, Capillary↗

On-line hyphenation of flow injection, miniaturized capillary electrophoresis and atomic fluorescence spectrometry for high-throughput speciation analysis.

A hyphenated technique was developed for high-throughput speciation analysis by on-line coupling of flow injection (FI), miniaturized capillary electrophoresis (CE) and atomic fluorescence spectrometry (AFS). Two interfaces were used to couple all three systems: the first to couple FI and CE and the second to couple miniaturized CE and AFS. The first interface was a modified flow through chamber, connected to the FI valve with a piece of PTFE tube (0.1mm i.d.x 20 cm long). The capillary outlet was coupled to the AFS by using the second concentric "tube-in-tube" interface. Split sampling was achieved in the electrokinetic mode. Inorganic mercury (Hg(II)) and methylmercury (MeHg(I)) were taken as model analytes to demonstrate the performance of the developed hyphenated technique. A volatile species generation (VSG) technique was employed to convert the analytes from the CE effluent into their respective volatile species. Baseline separation of Hg(II) and MeHg(I) was achieved by CE in a 50 microm i.d.x 8 cm long capillary at 3.0 kV within 60s. The precisions (RSD, n=12) were in the range of 0.7-0.9% for migration time, 3.8-4.2% for peak area, and 2.1-3.5% for peak height. The detection limits were 0.1 and 0.2 microgmL(-1) (as Hg) for Hg(II) and MeHg(I) with a sample throughput of 60 samples h(-1). The recoveries of both mercury species in the water samples studied were in the range of 93-106%.

Electrophoresis, Capillary↗

A study of low level selenium determination by hydride generation atomic fluorescence spectrometry in water soluble protein and peptide fractions.

Development of a method for very low level selenium determination in water soluble protein and peptide fractions, obtained after various separation procedures, is presented. A hydride generation atomic fluorescence spectrometry (HG-AFS) detection system was optimised and the influence of Cu(II), Sb(V), As(III) and HNO3 interferences in the measurement of Se by HG-AFS was investigated. A destruction procedure using HNO3 and H2O2 was also optimised and the average recovery of the digestion of a solution of selenomethioneine was 92 +/- 4% (n=14). Combination of this digestion with the detection system gave reliable results. Accuracy was tested by comparison with two independent methods. A very low detection limit (DL) of 0.2 ng/g of measuring solution was achieved. The whole procedure from weighing to measuring was performed in the same Teflon tube. The addition of HNO3 to the fractions before long term storage at -20 degrees C was necessary to prevent adsorption on the test tubes. Selenium was measured in water soluble protein and peptide fractions obtained after extraction, and Sephadex G-75 chromatography performed on liver samples from: i) hens exposed to As2O3, ii) hens fed with a high fat feed and iii) the certified reference material dogfish liver (CRM DOLT-2). Because of the very low DL we were able to observe the Se distribution in chromatographic fractions of samples of organisms which were not exposed to excess amounts of Se. The presence of selenium associated with metallothioneins was observed.

Animals↗

Rapid method for the determination of total mercury in urine samples using cold vapour atomic fluorescence spectrometry.

A rapid method for the determination of total mercury in urine samples is proposed. Samples are digested using a bromination procedure at room temperature. Analysis is performed using automated continuous flow vapour generation coupled to atomic fluorescence spectrometry. This approach allowed the analysis of 30 samples per hour and a limit of detection of 1 ng l-1. The analytical procedure was assessed using certified reference material NBS 2672a freeze-dried urine and two batches of Seronorm trace elements in urine samples.

Cold Temperature↗

Flow injection on-line sorption preconcentration coupled with hydride generation atomic fluorescence spectrometry for determination of (ultra)trace amounts of arsenic(III) and arsenic(V) in natural water samples.

A flow injection on-line sorption preconcentration and separation in a knotted reactor (KR) was coupled to hydride generation atomic fluorescence spectrometry (HG-AFS) for speciation of inorganic arsenic in natural water samples. The method involved on-line formation of the As(III)-pyrrolidinedithiocarbamate (PDC) complex over a sample acidity of 0.001-0.1 mol L(-1) HCl, its adsorption onto the inner walls of the KR made from 150-cm long x 0.5-mm i.d. PTFE tubing, elution withmol L(-1) HCl, and detection by HG-AFS. Total inorganic arsenic was determined after prereduction of As(V) to As(III) with 1% m/v L-cysteine. The concentration of As(V) was calculated by the difference of the total inorganic arsenic and As(III). A 1 mol L(-1) concentration of HCl was employed not only as the efficient eluent but also as the required medium for subsequent hydride generation. Potential factors that affect adsorption, rinsing, elution, and hydride generation were investigated in detail. The low cost, easy operation, and high sensitivity are the obvious advantages of the present system. With consumption of a 6 mL sample solution, an enhancement factor of 11 and a detection limit (3s) of 0.023 microg L(-1) As(III) were obtained at a sample throughput of 32 h(-1). The precision for 14 replicate measurements of 1 microg L(-1) As(III) was 1.3% (RSD). The recoveries from natural water samples varied from 96.7 to 105% for 2 microg L(-1) of As(III) spike and from 97.1 to 107% for 2 microg L(-1) of As(V) spike. The analytical results obtained by the present method for total arsenic in the certified reference materials, SLRS-4 (river water) and NASS-5 (seawater), agreed well with the certified values. The developed method was also successfully applied to the speciation of inorganic arsenic in local natural water samples.

Arsenic↗

New considerations about the separation and quantification of antimony species by ion chromatography-hydride generation atomic fluorescence spectrometry.

A new method for the speciation of inorganic [Sb(III) and Sb(V)] and organic (Me3SbCl2) antimony species by using a polystyrene-divinylbenzene-based anion-exchange HPLC column (Hamilton PRP-X100) coupled to hydride generation atomic fluorescence spectrometry (HG-AFS) is presented. Several mobile phases were tested for the baseline separation of these three antimony species, investigating in detail experimental parameters such as concentration and pH. The best efficiency and resolution was achieved by using a gradient elution between diammonium tartrate 250 mmol l(-1) pH 5.5 (A) and KOH 20 mmol l(-1) pH 12 (B). The gradient programme used was 100% B for 1.5 min, decreasing to 0% B in 0.1 min and maintained the elution with 100% A for 5.5 min. Analysis time was less than 7 min. Equilibration of the column with the complexing mobile phase was found to be critical in order to avoid Sb(III) double peak formation. Dilution in diammonium tartrate medium was necessary in order to avoid Sb(III) oxidation at microg l(-1) concentration level. Detection limits of 0.06 microg l(-1) for Sb(V), 0.09 microg l(-1) for Me3SbCl2 and 0.04 microg l(-1) for Sb(III) as well as repeatability and reproducibility better than 5% R.S.D. (n = 10) and 9% R.S.D. (n = 30) (for 1 and 5 microg l(-1) of Sb(V) and Sb(III) and 5 and 10 microg l(-1) of Me3SbCl2) were obtained. Accuracy and recovery studies were carried out by analysing one river freshwater sample and two water certified reference materials. The proposed methodology can be considered reliable and straightforward for antimony speciation in fresh water samples.

Antimony↗

Electrochemical vapor generation of selenium species after online photolysis and reduction by UV-irradiation under nano TiO2 photocatalysis and its application to selenium speciation by HPLC coupled with atomic fluorescence spectrometry.

An online UV photolysis and UV/TiO2 photocatalysis reduction device (UV-UV/TiO2 PCRD) and an electrochemical vapor generation (ECVG) cell have been used for the first time as an interface between high-performance liquid chromatography (HPLC) and atomic fluorescence spectrometry (AFS) for selenium speciation. The newly designed ECVG cell of approximately 115 microL dead volume consists of a carbon fiber cathode and a platinum loop anode; the atomic hydrogen generated on the cathode was used to reduce selenium to vapor species for AFS determination. The noise was greatly reduced compared with that obtained by use of the UV-UV/TiO2 PCRD-KBH4-acid interface. The detection limits obtained for seleno-DL: -cystine (SeCys), selenite (Se(IV)), seleno-DL: -methionine (SeMet), and selenate (Se(VI)) were 2.1, 2.9, 4.3, and 3.5 ng mL(-1), respectively. The proposed method was successfully applied to the speciation of selenium in water-soluble extracts of garlic shoots cultured with different selenium species. The results obtained suggested that UV-UV/TiO2 PCRD-ECVG should be an effective interface between HPLC and AFS for the speciation of elements amenable to vapor generation, and is superior to methods involving KBH4.

Catalysis↗

RETRACTED: X-ray fluorescence spectrometry of asteroid Itokawa by Hayabusa.

X-ray fluorescence spectrometry of asteroid 25143 Itokawa was performed by the x-ray spectrometer onboard Hayabusa during the first touchdown on 19 November 2005. We selected those data observed during relatively enhanced solar activity and determined average elemental mass ratios of Mg/Si = 0.78 +/- 0.09 and Al/Si = 0.07 +/- 0.03. Our preliminary results suggest that Itokawa has a composition consistent with that of ordinary chondrites, but primitive achondrites cannot be ruled out. Among ordinary chondrites, LL- or L-chondrites appear to be more likely than H-chondrites. No substantial regional difference was found on the asteroid surface, indicating its homogeneity in composition.

Journal Article↗

Nondestructive analysis of silver in gold foil using synchrotron radiation X-ray fluorescence spectrometry.

Small particles of gold foil detached from an indoor decoration might be important evidence to associate a suspect with a crime scene. We have investigated the application of elemental analysis using synchrotron radiation X-ray fluorescence spectrometry to discriminate small particles of gold foil. Eight kinds of gold foil samples collected in Japan were used in the experiments. As a result of synchrotron radiation X-ray fluorescence spectrometry, only two elements, gold and silver, were detected from all gold foil samples. The intensity ratios of AgKalpha/AuLalpha showed good correlation with the content ratios of Ag/Au. The variation of intensity ratio within a same sample was sufficiently small compared with those of different samples. Therefore the comparison of this intensity ratio can be an effective method to discriminate small particles originating from different types of gold foil.

Journal Article↗

Simultaneous speciation analysis of Sb(III), Sb(V) and (CH3)3SbCl2 by high performance liquid chromatography-hydride generation-atomic fluorescence spectrometry detection (HPLC-HG-AFS): application to antimony speciation in sea water.

This paper presents an improvement for the simultaneous separation of Sb(V), Sb(III) and (CH3)3SbCl2 species by high performance liquid chromatography (HPLC) and its detection by hydride generation-atomic fluorescence spectrometry (HG-AFS). The separation was performed on an anion exchange column PRP-X100 using a gradient elution program between EDTA/KHP (potasium hydrogen phtalate) as first mobile phase and phosphate solutions solution as the second one. The chromatographic separation and the HG-AFS parameters were optimized by experimental design. The best results were obtained by using an elution program with 20 mmol l(-1) EDTA + 2 mmol(-01) KHP solution at pH 4.5, during 1.15 min, then change to 50 mmol l(-1) (NH4)2HPO4 solution at pH 8.3, switching back after 4.0 min to the first mobile phase, until 5 min, with a constant flow rate of 1.5 ml min(-1). Retention time of Sb(V), Sb(III) and trimethylantimony species were 1.22, 2.31 and 3.45 min and the detection limits were 0.13; 0.07 and 0.13 microg l(-1), respectively. Studies on the stability of this antimony species in sea water samples on the function of the elapsed time of storage in refrigerator at 4 degrees C was performed employing the optimized method. Results revealed that Sb(III) is easily oxidized within some hours to Sb(V) in sea water stored at 4 degrees C. However, when the sea water was immediately mixed with EDTA no oxidation of Sb(III) was observed up to 1 week of storage. The proposed methodology was then applied to the antimony speciation in sea water samples.

Analysis of Variance↗

Cloud point extraction preconcentration prior to high-performance liquid chromatography coupled with cold vapor generation atomic fluorescence spectrometry for speciation analysis of mercury in fish samples.

A cloud point extraction methodology was developed for simultaneous preconcentration of Hg(II), methylmercury (MeHg), ethylmercury (EtHg), and phenylmercury (PhHg) prior to reversed-phase high-performance liquid chromatography (HPLC) on-line coupled with cold vapor atomic fluorescence spectrometry for speciation analysis of mercury in fish. The four mercury species were taken into complexes with ammonium pyrrolidine dithiocarbamate (APDC) in aqueous nonionic surfactant Triton X-114 medium and concentrated in the surfactant-rich phase by bringing the solution to the temperature of 40 degrees C. Baseline separation of the enriched complexes was achieved on an RP-C(18) column with a mixture of methanol, acetonitrile, and water (65:15:20, v/v) containing 200 mmol L(-1) HAc (pH 3.5) as the mobile phase. An on-line postcolumn oxidation of the effluent from HPLC, in the presence of K2S2O8 in HCl, was applied in the system followed by an optimal cold vapor generation of mercury species. The variables affecting the complexation and extraction steps were examined. The preconcentration of 10 mL of solution with 0.08% w/v Triton X-114 and 0.04% w/v APDC at pH 3.5 gave enrichment factors of 29, 43, 80, and 98 for MeHg, EtHg, PhHg, and Hg(II), respectively. Low detection limits (S/N = 3) were obtained, ranging from 2 to 9 ng L(-1) (as Hg) for all species. The developed method was successfully applied to the speciation of mercury in real fish samples.

Animals↗

Speciation analysis of arsenic in traditional Chinese medicines by hydride generation-atomic fluorescence spectrometry.

A method has been described for the determination of arsenic species (arsenite and arsenate) by hydride generation-atomic fluorescence spectrometry (HG-AFS). The experimental conditions that influence the fluorescence intensity and the reduction of arsenic were investigated and optimized, and the influences from foreign ions and their elimination were studied. The detection limit was found to be 79.7 ng L(-1). The proposed method was applied to the determination of arsenic species in water leachate of traditional Chinese medicines with a recovery range of 91.1-109.5%.

Arsenic↗

X-ray absorption fine structure combined with fluorescence spectrometry for monitoring trace amounts of lead adsorption in the environmental conditions.

The local structure of trace amounts of lead in an adsorbent matrix that contains a high concentration of iron and magnesium (Mg6Fe2(OH)16(CO3) x 3H2O) was successfully monitored by means of X-ray absorption fine structure spectroscopy combined with fluorescence spectrometry. A eutectic mixture of PbCO3 and Pb(OH)2 coagulated when Pb2+ was adsorbed from a 1.0 ppm aqueous solution, and in contrast, the major species was ion-exchanged Pb2+ in the case of adsorption from a 100 ppb aqueous solution. The difference was ascribed to the balance between the precipitation equilibrium for coagulation and the rate of the ion exchange reaction with surface hydroxyl groups.

Carbonates↗

Fractionation and redox speciation of antimony in agricultural soils by hydride generation--atomic fluorescence spectrometry and stability of Sb(III) and Sb(V) during extraction with different extractant solutions.

This stability of Sb(III) and Sb(V) species was studied during single extraction from soils by water. EDTA, diluted H2SO4 and H3PO4, and oxalic acid/oxalate solutions, with and without ascorbic acid, were used as stabilizing reagent of both Sb species. Antimony redox speciation in soil extracts was performed by selective hydride generation-atomic fluorescence spectrometry. Simulated extraction procedures (without soil) showed that, except in oxalate medium, Sb(III) was oxidized to Sb(V), and this reaction was avoided with ascorbic acid. Recovery studies from a spiked agricultural soil showed that no oxidation but sorption of Sb(III) occurred during the extraction process in water and H2SO4 medium, and quantitative oxidation in EDTA and oxalate medium. With ascorbic acid, this oxidation was totally avoided in EDTA and partially avoided in oxalate solution. A new sequential extraction procedure was proposed and applied to the fractionation and redox speciation of antimony in agricultural soils, using EDTA + ascorbic acid, pH 7 (available under complexing and moderately reducible conditions); oxalic acid/oxalate + ascorbic acid (extractable in reducible conditions) and HNO3 + HCl + HF (residual fraction). The proposed extraction scheme can provide information about the availability and mobility of antimony redox species in agricultural soils.

Agriculture↗

Application of total reflection X-ray fluorescence spectrometry to small glass fragments.

Total reflection X-ray fluorescence spectrometry (TXRF) has been applied for trace elemental analysis of small glass fragments. A small glass sample (a fragment with weight less than 0.5 mg) was decomposed by 100 microg of HF/HNO3 acid; the material was condensed to 10 microl and was dried on a Si wafer. Since the size of the dried residue on the Si wafer was less than 1 cm in diameter, an incident X-ray beam with about 1 cm in width could effectively excite elemental components in such a small glass fragment. The precision of the present technique was checked by analyzing the glass fragments (<0.5 mg) from NIST SRM612; the relative standard deviations (RSD) of less than 8.1% were achieved for elemental ratios that were normalized by Sr. Fragments (<0.5 mg) obtained from 23 figured sheet glasses were used as samples for estimating the utility of this technique to forensic discrimination. Comparison of five elemental ratios of Ti/Sr, Mn/Sr, Zn/Sr, Rb/Sr, and Pb/Sr calculated from X-ray fluorescence spectra was effective in distinguishing glass fragments that could not be differentiated by their refractive indexes (RI).

Journal Article↗

Total uncertainty budget calculation for the determination of mercury in incineration ash (BCR 176R) by atomic fluorescence spectrometry.

The mercury mass fraction has been determined by atomic fluorescence spectrometry (AFS) in the framework of the project "Certification of a reference material (trace elements in fly ash) in replacement of BCR CRM 176". Calculation of the uncertainty budget, as described in this manuscript, emphasizes a practical and realistic approach to estimation of uncertainty components on the basis of statistical assumptions. GUM Workbench software was used, and resulted in a mercury mass fraction of 1.58+/-0.11 mg kg(-1) (with coverage factor k=2.2, 95% probability) related to dry mass, submitted in the certification exercise. The calculated total uncertainty budget applies to analogous samples analyzed by this procedure.

Journal Article↗

[Progress in determination of rare earths by atomic/ionic fluorescence spectrometry].

The progress of determination of rare earths by atomic/ionic fluorescence spectrometry is reviewed. The experimental systems and the analytical characteristics of the technique are briefly discussed, and its applications are illustrated in detail. The research trends are predicted as well. The systems with appropriate combinations of excitation sources and atomization/ionization cells are well proved to increase analytical sensitivity and minimize interferences. For the excitation soures, hollow cathode lamp has been proved to be economic and practical, although pulsed dye laser has been intensively investigated. The inductively oupled plasma is a preferable atomization/ionization cell. The atomic/ionic fluorescene spectrometry is one of effective techniques for the determination of rare earths mainly due to its low spectral interference and wide linear dynamic range.

English Abstract↗