Real-time soft tissue modelling for web-based surgical simulation: SurfaceChainMail.

The Web provides a useful environment for simple surgical training simulations. A combination of VRML for 3D rendering, and Java code for the simulation engine, has been used for a range of simple neurosurgical demonstrators. However the elements in these simulators are rigid, to avoid the computational complexity of deformable modelling. In this paper we describe a variation of the ChainMail technique that allows us to provide real-time deformable modelling, even in a Web browser environment on a PC. Our new algorithm, SurfaceChainMail, has been used to develop a simulator for the cutting of two layers of tissue, and separating the layers by pulling them apart.

Algorithms↗

Virtual vitreoretinal surgical simulator as a training tool.

OBJECTIVE: To demonstrate the feasibility and potential applicability of a virtual reality simulator for vitreoretinal surgery as a training and/or assessment tool. METHODS: The subjects of this study included medical students, ophthalmologic residents, and trained vitreoretinal surgeons. There were three study groups. Group I comprised 22 subjects who performed a navigation task. The time to complete the task was recorded. The relationship between the completion time, experience, and stereopsis was evaluated. Group II included 6 subjects who consecutively performed the navigation task to evaluate their learning curve. Group III included 16 subjects who performed the membrane peeling task. The number of retinal contacts and the completion time were recorded. The relationship between experience and stereopsis with the number of contacts and the completion time were evaluated. RESULTS: The average completion time in Group I for students, residents, and trained surgeons was 121.6, 92.5, and 70.6 seconds. There was a significant difference between students and trained surgeons (P = 0.004). In Group II, there was a significant decrease in the completion time with training (P = 0.001). In Group III, the average completion time for students, residents, and trained surgeons was 197, 144, and 118.2 seconds; the respective number of retinal contacts was 14, 8, and 3. There was a significant difference between students and residents (P = 0.05) and between residents and trained surgeons (P = 0.003) for the average completion time in Group III. There was a significant difference between students and trained surgeons (P = 0.003) for the number of contacts per average time and between students and residents (P = 0.05). There was a significant inverse correlation between stereopsis vision score and completion time in Group I and number of contacts per average time (P = 0.0004 and P = 0.01, respectively). CONCLUSIONS: This study demonstrates potential applications of a vitreoretinal surgical simulator as a training and skills assessment tool for novice, inexperienced, and trained surgeons. A simulator can be used to teach specific techniques and train surgeons.

Adult↗

A high fidelity tissue-based cardiac surgical simulator.

OBJECTIVE: Issues concerning the training and certification of surgical specialists have taken on great significance in the last decade. A realistic computer-assisted, tissue-based simulator developed for use in the training of cardiac surgical residents in the conduct of a variety of cardiac surgical procedures in a low-volume cardiothoracic surgery unit of a typical developing country is described. The simulator can also be used to demonstrate the function of technology specific to cardiac surgical procedures in a way that previously has only been possible via the conduct of a procedure on a live animal or human being. METHODS: A porcine heart in a novel simulated operating theatre environment with real-time simulated haemodynamic monitoring and coronary blood flow, in arrested and beating-heart modes, is used as a training tool for surgical residents. RESULTS: Standard and beating-heart coronary arterial bypass, aortic valve replacement, aortic homograft replacement and pulmonary autograft procedures can be simulated with high degrees of realism and with the superimposition of adverse clinical scenarios requiring valid decision making and clinical judgments to be made by the trainees. CONCLUSIONS: The cardiac surgical simulation preparation described here would appear to be able to contribute positively to the training of residents in low-volume centres, as well as having the potential for application in other settings as a training tool or clinical skills assessment or accreditation device. Collaboration with larger centres is recommended in order to accurately assess the utility of this preparation as an adjunctive cardiothoracic surgical training aid.

Animals↗

Tele-surgical simulation system for training in the use of da Vinci surgery.

Laparoscopic surgery including robotic surgery allows the surgeon to be able to conduct minimally invasive surgery. A surgeon is required to master difficult skills for this surgery to compensate for the narrow field of view, limitation of work space, and the lack of depth sensation. To counteract these drawbacks, we have been developing a training simulation system that can allow surgeons to practice and master surgical procedures. In addition, our system aims to distribute a simulation program, to provide a means of collaboration between remote hospitals, and to be able to provide a means for guidance from an expert surgeon. In this paper, we would like to show the surgery simulation for da Vinci surgery, in particular a cholecystectomy. The integral parts of this system are a soft tissue model which is created by the sphere-filled method enabling real-time deformations based on a patient's data, force feedback devices known as a PHANToM and the Internet connection. By using this system a surgeon can perform surgical maneuvers such as pushing, grasping, and detachment in real-time manipulation. Moreover, using the broadband communication, we can perform the tele-surgical simulation for training.

Computer Simulation↗

Surgical simulation: a current review.

BACKGROUND: Simulation tools offer the opportunity for the acquisition of surgical skill in the preclinical setting. Potential educational, safety, cost, and outcome benefits have brought increasing attention to this area in recent years. Utility in ongoing assessment and documentation of surgical skill, and in documenting proficiency and competency by standardized metrics, is another potential application of this technology. Significant work is yet to be done in validating simulation tools in the teaching of endoscopic, laparoscopic, and other surgical skills. Early data suggest face and construct validity, and the potential for clinical benefit, from simulation-based preclinical skills development. The purpose of this review is to highlight the status of simulation in surgical education, including available simulator options, and to briefly discuss the future impact of these modalities on surgical training.

Clinical Competence↗

Photo-realistic tissue reflectance modelling for minimally invasive surgical simulation.

Computer-based simulation is an important tool for surgical skills training and assessment. In general, the degree of realism experienced by the trainees is determined by the visual and biomechanical fidelity of the simulator. In minimally invasive surgery, specular reflections provide an important visual cue for tissue deformation, depth and orientation. This paper describes a novel image-based lighting technique that is particularly suitable for modeling mucous-covered tissue surfaces. We describe how noise functions can be used to control the shape of the specular highlights, and how texture noise is generated and encoded in image-based structure at a pre-processing stage. The proposed technique can be implemented at run-time by using the graphics processor to efficiently attain pixel-level control and photo-realism. The practical value of the technique is assessed with detailed visual scoring and cross comparison experiments by two groups of observers.

Bronchoscopy↗

Heuristic haptic texture for surgical simulations.

Generation of credible force feedback renderings adds the sense of touch crucial for the development of a realistic virtual surgical environment. However, a number of difficulties must be overcome before this can be achieved. One of the problems is the paucity of data on the in-vivo tissue compliance properties needed to generate acceptable output forces. Without this "haptic texture," the sense of touch component remains relatively primitive and unrealistic. Current research in the quantitative analysis of biomechanics of living tissue, including collection of in-vivo tissue compliance data using specialized sensors, has made tremendous progress. However, integration of all facets of biomechanical data in order to transfer them into haptic texture remains a very difficult problem. For this reason, we are attempting to create a library of heuristic haptic textures of anatomical structures. The library of heuristic haptic textures will capture the expert's sense of feel for selected anatomical structures and will be used to convey the sense of touch for surgical training simulations. Once the techniques for converting biomechanical data into haptic texture become more robust, this library can be used as a benchmark to verify theoretical computational models used for generating output forces in haptic devices.

Biomechanical Phenomena↗

Effects of interferon-gamma treatment on surgically simulated wound infection in mice.

Interferon-gamma (IFN-gamma) has been shown to have immunoregulatory properties and is able to modulate resistance to several microbial infections. This study was designed to determine the efficacy of IFN-gamma treatment in a mouse model of infection that simulates many clinical conditions associated with surgical wound infection: viz, a bacteria laden suture and tissue injury. The test bacteria were Klebsiella pneumoniae. Groups of CBA/J mice received either IFN-gamma or RPMI-1640 medium (controls) subcutaneously. IFN-gamma was administered daily at a dose of 7500 units for 5 days prior to bacterial challenge. Mice treated with IFN-gamma survived significantly longer than controls. Systemic bacterial recovery was significantly reduced in the IFN-gamma treated group but local bacterial recovery was unaffected.

Adjuvants, Immunologic↗

High-level visual-spatial ability for novices correlates with performance in a visual-spatial complex surgical simulator task.

BACKGROUND: This study addresses how high-level visual-spatial ability of surgical novices is related to performance of two simulator tasks with (KSA) and without (MIST) anatomic graphics and haptic feedback, differing in visual-spatial complexity. METHODS: Visual-spatial test scores assessed by Mental Rotation Test (MRT) and BasIQ and performance scores for Instrument Navigation (IN) in Key Surgical Activities (Procedicus KSA) and Manipulate and Diathermy (MD) in Minimally Invasive Surgical Trainer (Procedicus MIST) were correlated for 54 Swedish surgical novices. RESULTS: Significant Pearson's r correlations were obtained between visual-spatial scores measured by MRT-C and total score from the last trial for IN (r = 0.278, p < 0.05). Visual-spatial scores (measured by BasIQ) also correlated with total score from the first trial (r = 0.443, p < 0.05) and from the last trial (r = 0.489, p < 0.05). CONCLUSION: High-level visual-spatial ability is important for surgical novices to possess in the early training phase of a visual-spatial complex task in KSA.

Adult↗

Effects of a moderate dose of alcohol on simulated laparoscopic surgical performance.

BACKGROUND: In medicine, there is no professional regulation of the drinking of alcohol, nor a body of experimental evidence on which such regulation might be based. Here we report the acute and longer-term ("hangover") effects of a moderate dose of alcohol on performance, as assessed objectively on a laparoscopic surgical simulator. METHODS: In a single-blind, experimental study, medical student subjects were assigned randomly to an alcohol (1.05 mg/kg) or a placebo condition (n = 14 in each). The effects of alcohol on performance on the MIST Virtual Reality surgical simulator were examined 60-90 min and 600-630 min (after a night's sleep) following its ingestion. Measures of the number of errors, time taken, hand movement economy, and excessive use of diathermy were recorded. RESULTS: On each measure, performance was significantly impaired 60-90 min following alcohol ingestion, but there was no hangover effect 600-630 min later, following a night's sleep. This impairment could not be attributed to between-group differences in either predrink performance, expertise or estimated sleep duration during the night preceding the experimental session. CONCLUSIONS: Simulated surgical performance is impaired severely when estimated blood alcohol concentration (BAC) is just above the UK legal limit for driving. These results contribute new, objective and quantitative evidence to the current debate about the use and misuse of alcohol within the medical profession.

Adult↗

Real-time volumetric deformation for surgical simulation using force feedback device.

We have aimed to develop a virtual surgery system that realizes the performance of surgical maneuvers on elastic organs and to construct an elastic organ model known as sphere-filled model. In this paper we describe a new method of deforming volumetric data in real time by using sphere-filled model. As well we modified this model to take the interference between soft tissue and rigid tissue to consideration. Furthermore basic surgical maneuvers (pushing, pinching and incision) and connection with force feedback device are realized on this model similarly to our surface model.

Computer Simulation↗

[Development of a surgical simulator for interventions of the paranasal sinuses. Technical principles and initial prototype].

BACKGROUND: Traditional training methods for surgeons include anatomical studies on human cadavers. Limited availability and ethical problems led to the consideration of alternatives. The surgeon's level of training could be significantly increased by a interactive training system trough computer graphics and virtual reality (VR). METHODS: Two main issues addressed are the 3-D reconstruction process and 3-D interaction to guide the surgical instruments. To provide the virtual environment, a realistic representation of the region of interest with all relevant anatomical parts is required. This model has to be suitable for computer simulation, while preserving as accurately as possible important anatomic features. Therefore the concept of creating a 3-D representation semi-automatically was developed. Textures derived from endoscopic images are superimposed on the virtual anatomic structures and provide better realism. RESULTS: Intuitive handling of the surgical instruments is ensured by using the tracking technique. The system allows navigation via a virtual camera and interaction with the virtual anatomical structures. Currently the use of a force feedback system and the simulation of deformations of tissues is critical. CONCLUSIONS: The VR based simulation system offers an alternative to conventional training methods. The future role of surgical simulation depends on overcoming the current drawbacks to provide greater interactive realism: the integration of a force feedback system to simulate the resistance of anatomical structures and the simulation of tissue deformations--both currently under development.

Artificial Intelligence↗

Surgical simulation software for insertion of pedicle screws.

OBJECTIVE: As the first step toward finding noninvasive alternatives to the traditional methods of surgical training, we have developed a small, stand-alone computer program that simulates insertion of pedicle screws in different spinal vertebrae (T10-L5). METHODS: We used Delphi 5.0 and DirectX 7.0 extension for Microsoft Windows. This is a stand-alone and portable program. RESULTS: The program can run on most personal computers. It provides the trainee with visual feedback during practice of the technique. At present, it uses predefined three-dimensional images of the vertebrae, but we are attempting to adapt the program to three-dimensional objects based on real computed tomographic scans of the patients. The program can be downloaded at no cost from the web site: www.tums.ac.ir/downloads CONCLUSION: As a preliminary work, it requires further development, particularly toward better visual, auditory, and even proprioceptive feedback and use of the individual patient's data.

Bone Screws↗

Measuring in vivo animal soft tissue properties for haptic modeling in surgical simulation.

To provide data for the design of virtual environments and teleoperated systems for surgery, it is necessary to measure tissue properties under both in vivo and ex vivo conditions. The former provides information about tissue behavior in its physiological state, while the latter can provide better control over experimental conditions. We have developed devices to measure tissue properties under extension and indentation, as well as to record instrument-tissue interaction forces. We are creating a web database of data recorded from porcine abdominal tissues.

Abdomen↗

Achieving proper exposure in surgical simulation.

One important technique common throughout surgery is achieving proper exposure of critical anatomic structures so that their shapes, which may vary somewhat among patients, can be confidently established and avoided. In this paper, we present an algorithm for determining which regions of selected structures are properly exposed in the context of a mastoidectomy simulation. Furthermore, our algorithm then finds and displays all other points along the surface of the structure that lie along a sufficiently short and straight path from an exposed portion such that their locations can be safely inferred. Finally, we present an algorithm for providing realistic visual cues about underlying structures with view-dependent shading of the bone.

Algorithms↗