PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Sutureless”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

[Self-sealing, sutureless sclerotomy in pars plana vitrectomy].

BACKGROUND: If sutures are used in the regular closure of sclerotomies a trauma to the bulbus can be inflicted and intraocular bleeding might result. Phases of intraocular hypotony accompany the intraoperative exchange of instruments. Like in no-stitch cataract surgery we employed this type of self-sealing wound closure in pars-plana vitrectomies. A less traumatizing technique yielding a tight and effective closure is an alternative to the conventional approach and results of our experiences are presented. MATERIALS AND METHODS: A modified approach for sutureless sclerotomy closure was applied in 50 eyes (150 sclerotomies). A sclera-covered sclerotomy is performed after preparation of adequate scleral pouches in conventional positions. A minimal conjunctival peritomy allows at the end of surgery an electric cauterization, thus using no suture material in the whole course of vitrectomy. RESULTS: Sutureless vitrectomies can only be installed in the primary operation. However, re-operations on 3 eyes were possible in the same manner using the old sclerotomy sites up to 6 weeks after initial surgery. In 12 eyes the sclerotomy had to be covered with a single suture to obtain adequate wound closure. A repetitive change of instruments during the surgical procedure is possible with this technique and all types of intraocular instruments can be employed. CONCLUSIONS: Self-sealing sclerotomies are a simple and atraumatic approach for wound closure in pars-plana vitrectomies and allow a control of intraocular pressure during surgery.

Follow-Up Studies↗

The sutureless aortic valve prosthesis: experience with and technical considerations for replacement of the early model.

Reoperation was performed in seven (16%) of 43 patients with early models of Magovern sutureless aortic valve prostheses, because of thromboembolism and ball variance. All patients survived reoperation with no major complications. Removal of the sutureless prosthesis was not difficult when an insertion tool of proper size was used. A scarred annulus remained which was favorable for the suturing of a new prosthesis. The incidence of disabling thromboembolism (42%) and poppet failure (21%) is high with these early models. When these complications occur, replacement of the prosthesis is recommended to prevent death or recurrent embolic episodes.

Adult↗

Sutureless closed hemorrhoidectomy: a new technique.

OBJECTIVE: To compare a new technique of radical hemorrhoidectomy using an electrothermal device originally devised to seal vessels in abdominal operations, with the conventional open Milligan-Morgan procedure performed with diathermy. SUMMARY BACKGROUND DATA: Hemorrhoidectomy is one of the most commonly performed anorectal operations. Two well-established methods, the "open" Milligan-Morgan excision and the "closed" Ferguson technique, both carry risks of postoperative bleeding, urinary retention, and late anal stenosis. The convalescence is similarly long and difficult after both operations. The quest for an improved technique of radical excision of hemorrhoids is justified. METHODS: In this case-control study, two groups of patients were alternatively allocated into study and control groups. In the study group (n = 40), an electrothermal system was used. The tissue fusion produced by this device consists of melting of collagen and elastin. This technique essentially achieves a sutureless closed hemorrhoidectomy. The operative time, postoperative complications, and time off work were compared with the group undergoing conventional Milligan-Morgan hemorrhoidectomy (control group, n = 40). RESULTS: The operative time and time off work were significantly shorter in the study group. There were also fewer postoperative complications in this group. CONCLUSIONS: The "tissue-welding" properties of this device and the shape of the electrode handpiece may be successfully applied to the performance of an operation most appropriately described as a "modified sutureless closed hemorrhoidectomy." This pilot study shows that this new technique is simple and safe, significantly shortens the operation, and is followed by a significantly easier and shorter recovery.

Adult↗

End-to-side anastomosis using a new sutureless vascular prosthesis.

Performing a conventional vascular anastomosis during minimally invasive surgery remains a technically difficult and time-consuming task. The purpose of our study was to assess the efficacy of a new sutureless vascular prosthesis. Through a left thoracotomy, a short segment of the descending aorta was bypassed in eight sheep. Our Dacron prosthesis had a cuff at one extremity. The cuff was introduced into the artery through an arteriotomy and attached to the arterial wall with clips. Surgery was performed on the sheep again 12-15 weeks later, and the prosthesis was retrieved for macroscopic and microscopic examination. At surgery, insertion of the prosthesis was easy, fast, and safe. A 3-4 mm space between each clip was required for proper attachment. At the second surgery, all prostheses were completely patent and there were no anastomotic stenoses or aneurysms. This new sutureless vascular prosthesis was easy and safe in its placement and might prove useful for video assisted vascular aortic surgery.

Anastomosis, Surgical↗

Sutureless, posterior lamellar keratoplasty: a case report of a modified technique.

PURPOSE: To describe a technique for sutureless, posterior lamellar keratoplasty. METHODS: The procedure was performed for a case of pseudophakic bullous keratopathy. Through a 5.0-mm, self-sealing scleral tunnel incision, a stromal pocket was dissected across the cornea, just above Descemet's membrane. An 8.5-mm diameter posterior lamellar disc, consisting of posterior stroma, Descemet's membrane, and endothelium, was transplanted without suture fixation. RESULTS: One week after surgery, the best spectacle corrected visual acuity (BSCVA) was 0.8 (20/25), with S -1.5 and C -1.0 x 85 degrees. After 1 year, the posterior transplant was clear and in position, and the BSCVA was 0.8 with S -1.5 and C -1.75 x 80 degrees. Pachymetry measured 0.60 mm. Endothelial cell counts averaged 1390 cells/mm2. CONCLUSION: Sutureless, posterior lamellar keratoplasty may be an effective new surgical approach for managing corneal endothelial disorders.

Corneal Diseases↗

Pacing failure due to an unusual fracture of the sutureless myocardial electrode.

A 64-year-old man, had an apicardial demand pacemaker implanted for treatment of Mobitz type II heart block. Two sutureless myocardial electrodes were inserted, but a unipolar system was used based on stimulation threshold and sensitivity measurements. Fourteen months later the patient presented with pacing failure caused by a fracture of the corkscrew electrode with wide separation of the broken ends. The pacemaker, however, continued to inhibit satisfactorily. Pacing was successfully reestablished employing the second available lead. To our knowledge, there has been no publication reporting this type of failure of the sutureless myocardial electrode.

Electrodes, Implanted↗

Sutureless gingival grafting. A simplified procedure.

Suturing a gingival graft is often the most time-consuming stage of the grafting procedure, especially in regions of difficult access. Previously, it has been suggested that a combination of adhesive cellophane and cyanoacrylate may be used to immobilize the graft without suturing. The technique presented here attempts to simplify further sutureless grafting with the following modifications: - Bandage tape is used instead of adhesive cellophane. - The tape is not placed on the teeth but on the attached gingiva on either side of the graft site. - The use of cyanoacrylate is discarded. The success of the procedure depends on complete haemostasis as any moisture will prevent the tape from adhering to the gingiva. Inherent advantages of sutureless grafting accomplished with the use of bandage tape are: - The graft lies flat on the recipient site and is kept under slight pressure by the tape. - Minimal blood clot is present between the graft and the recipient site. - The "wick" effect of the sutures is eliminated. - The chairside time is greatly reduced. - A shorter appointment and no sutures to remove imply less discomfort for the patient. The technique is contraindicated should the patient present an allergic background to bandage tape.

Bandages↗

Sutureless cataract surgery with nucleus extraction: outcome of a prospective study in Nepal.

AIM: To report the short and medium term outcome of a prospective series of sutureless manual extracapsular cataract extractions (ECCE) at a high volume surgical centre in Nepal. METHODS: Cataract surgery was carried out, on eyes with no co-existing diseases, in 500 consecutive patients who were likely to return for follow up. The technique involved sclerocorneal tunnel, capsulotomy, hydrodissection, nucleus extraction with a bent needle tip hook, and posterior chamber intraocular lens (PC-IOL) implantation according to biometry findings. Surgical complications, visual acuity at discharge, 6 weeks, and 1 year follow up, and surgically induced astigmatism are reported. RESULTS: The uncorrected visual acuity at discharge was 6/18 or better in 76.8% of eyes, and declined to 70.5% at 6 weeks' follow up, and 64.9% at 1 year. The best corrected visual acuity was 6/18 or better in 96.2% of eyes at 6 weeks and in 95.9% at 1 year. Poor visual outcome (<6/60) occurred in less than 2%. Intraoperative complications included 47 (9.4%) eyes with hyphaema, and one eye (0.2%) with posterior capsule rupture and vitreous in the anterior chamber. Surgery led to an increase in against the rule astigmatism, which was the major cause of uncorrected visual acuity less than 6/18. Six weeks postoperatively, 85.5% of eyes had against the rule astigmatism, with a mean induced cylinder of 1.41 D (SD 0.8). There was a further small increase in against the rule astigmatism of 0.66 D (SD 0.41) between 6 weeks and 1 year. The mean duration of surgery was 4 minutes and the average cost of consumables, including the IOL, was less than $10. CONCLUSION: Rapid recovery of good vision can be achieved with sutureless manual ECCE at low cost in areas where there is a need for high volume cataract surgery. Further work is required to reduce significant postoperative astigmatism, which was the major cause of uncorrected acuity less than 6/18.

Aged↗

Tissue adhesives for a sutureless fadenoperation: an experimental study in a rabbit model.

PURPOSE: To use tissue adhesives for a sutureless Fadenoperation to eliminate perioperative risks related to the sutures. METHODS: In an in vivo procedure, 120 superior recti muscles in New Zealand White rabbits were subjected to the posterior fixation procedure, at a distance of 6 mm from the insertion point of the muscle. They were divided into four groups of 30 muscles, according to the material used to perform a myopexy: group 1 (control): nonabsorbable 5-0 polyester sutures; group 2: n-butyl-2-cyanoacrylate adhesive; group 3: fibrin glue; group 4: gelatin-resorcin-formaldehyde-glutaraldehyde (GRFG) adhesive. The animals were examined at 1, 7, 14, and 21 days after surgery. Afterward, they were killed, and their eyes were enucleated to measure the distance between the myopexy and the anatomic insertion point and to assure the strength of the bond with a dynamometer. Finally, a histologic examination was performed. RESULTS: Almost all eyes were clear after the third week, although group 4 presented the most intense inflammatory reaction. In histologic examination, groups 1 and 2 showed a chronic inflammatory reaction of the foreign-body type, with similar intensity. Fibrin glue induced minimal inflammation, but GRFG adhesive produced a pronounced reaction. Concerning the distance of the myopexy, groups 1 and 2 presented measures close to the expected distance of 6 mm, whereas groups 3 and 4 showed a greater variability. All groups performed well in the strength test, with no statistically significant differences among them. CONCLUSIONS: n-Butyl-2-cyanoacrylate adhesive performed best in the sutureless Fadenoperation, characterized by precision in the expected distance of myopexy, sufficient resistance to separation, and acceptable inflammatory reaction.

Animals↗

25-Gauge transconjunctival sutureless pars plana vitrectomy.

PURPOSE: To evaluate the effectiveness, feasibility, and safety of the transconjunctival sutureless vitrectomy (TSV) system for a vriety of vitreoretinal diseases. METHODS: In this retrospective study, the authors evaluated 71 eyes of 63 patients who underwent pars plana vitrectomy (PPV) with the 25-gauge TSV system. The indications for surgical intervention were diabetic vitreous hemorrhage (29 eyes), diabetic macular edema (14 eyes), macular epiretinal membrane (13 eyes), endophthalmitis (5 eyes), vitreous opacities secondary to Behcet's disease (4 eyes), vitreous hemorrhage secondary to branch retinal vein occlusion (4 eyes), and vitreous hemorrhage secondary to age-related macular degeneration (2 eyes). Epiretinal membrane and internal limiting membrane removal, endolaser photocoagulation, and air-fluid exchange were performed when required. RESULTS: Mean follow-up was 3.6 months (range 1-8 months). Mean overall visual acuity (VA) was counting fingers (range light perception to 0.4) preoperatively and 0.2 (range 0.1 to 0.8) postoperatively (p=0.000). Statistically significant VA improvement was observed in eyes with vitreous hemorrhage, diabetic macular edema, and macular epiretinal membrane. VA improved postoperatively in all eyes with endophthalmitis and vitreous opacities secondary to Behcet's disease. The surgery was completed without conjunctival and scleral suturing in all eyes. Mean intraocular pressure (IOP) was 17.2 mmHg (range 10-26 mmHg) preoperatively, 12.4 mmHg (range 6-24 mmHg) on the first postoperative day, 16.6 mmHg (range 10-33 mmHg) at 1 week, and 15.4 mmHg (range 10-20 mmHg) at 1 month postoperatively. On the first postoperative day, IOP was below 10 mmHg (between 6 and 9 mmHg) in 12 eyes (16.9%). In these eyes, IOP was normalized within 1 week without affecting the visual outcome. Five eyes (7%) had transient increase of IOP controlled by topical antiglaucomatous medications. Vitreous washout using 25-gauge TSV system was performed in two eyes, in which vitreous hemorrhage recurred. CONCLUSIONS: The TSV system was observed to be feasible, effective, and safe for a variety of vitre o retinal diseases. This minimally invasive and completely sutureless (transconjunctival) technique appears to decrease the convalescence period, operating time, and postoperative inflammatory response, and improve patient comfort.

Adult↗

A simple method for sutureless gastrointestinal anastomosis in rat.

A simple tubing stent was attempted to test a model for sutureless gastrointestinal anastomosis in 6 male rats at the age of 15 weeks. In the 3rd and 4th weeks after the operation, X-ray examination demonstrated that the gastrointestinal passage in the anastomotic site was quite satisfactory. There was no incidence of anastomotic leakage. In the 6th week after the operation, there were no macroscopic or microscopic ruptures, nor were there any obstructions at the anastomotic site. This simple sutureless method was effective at preparing anastomosis in the gastrointestinal tract in the rat and could be applied to other small experimental animals.

Anastomosis, Surgical↗

Sutureless anastomosis of the small intestine and the colon in pigs using an absorbable intraluminal stent and fibrin glue.

A new sutureless anastomosis technique employing a sliding absorbable intraluminal nontoxic stent (SAINT) and fibrin glue with limited (minutes) stump margin pressure is described. Fifty-one (27 small intestine, 24 colon) SAINT anastomoses were performed in 31 Landrace pigs (25-35 kg). Controls consisted of 48 (26 small intestine, 22 colon) continuous single-layer submucosal anastomoses in 26 pigs. SAINTs, which dissolve in about 30-60 min, were formed from heated sucrose and water poured into handcrafted aluminum molds. Follow-up from 7 to 540 days showed no stenosis or anastomotic imperfections in the latter part of the experiment after the SAINT production and surgical techniques were improved. The SAINT group had fewer site adhesions, faster healing, less foreign body reaction, and fewer lymphocytes than the control group. Initial results indicate that the SAINT-fibrin glue procedure may be an effective sutureless anastomotic method from the duodenum to the sigmoid colon.

Anastomosis, Surgical↗

Sliding, absorbable, reinforced ring and an axially driven stent placement device for sutureless fibrin glue gastrointestinal anastomosis.

Reduced blood flow of from 43 to 71% has been reported in sutured and stapled anastomoses. The sutureless sliding, absorbable, intraluminal, nontoxic stent (SAINT)-fibrin glue anastomotic method, which clamps the stump margins between 2 dissolving surfaces, includes only two stages of temporary compression (about 6 min total using 4 IU/mL thrombin) during the glue application in order to promote vascularization. A SAINT placement device (SAINT-PD) was introduced to facilitate low rectal anastomoses. Morphohistologic results from limited trials using fibrin glue with an untied sutureless stapler technique and a prototype non-gear-driven SAINT-PD, neither having the two dissolvable clamping surfaces of the SAINT, showed a 29 and 25% incidence of intraluminal tissue ridges, respectively. Since these tissue ridges could result in subclinical dilatation or frank stenosis, and the more extensive SAINT trials had an 8% incidence of tissue ridges, redesign of the SAINT-PD was undertaken. Consequently, to improve the anastomotic quality of the SAINT-PD, the sliding absorbable reinforced ring (sucrose base) acting as the second dissolvable surface for the SAINT-PD and a new axially controlled geared SAINT-PD design are described.

Anastomosis, Surgical↗

Vitreoretinal surgery using transconjunctival sutureless vitrectomy.

This report presents the effectiveness of 25-gauge Transconjunctival Sutureless Vitrectomy (TSV) for various vitreoretinal disorders. We performed vitreoretinal surgery on 6 patients using 25-gauge TSV. Minimal or no leakage of intraocular fluid or gas was observed at the entry site. No case required a suture to close the conjunctival or scleral opening site, and no complications resulted from the opening site. Median preoperative visual acuity was 0.04 and median postoperative best corrected visual acuity (BCVA) with a mean follow-up of 12 weeks, was 0.45. Median preoperative intraocular pressure was 12.67 mmHg, and median intraocular pressure on the first postoperative day was 15.67 mmHg. Because transconjunctival sutureless surgery is minimally invasive, it increases the efficiency of vitrectomy, hastens postoperative recovery, and improves outcomes due to the simplified surgical procedure. We feel that the adoption of the 25-gauge TSV would lead to improved patient comfort, care, and management.

Adult↗

Results of sutureless wound construction in children undergoing cataract extraction.

A prospective study was performed to evaluate the efficacy of self-sealing (sutureless) wound construction for cataract surgery in children. Self-sealing wounds were constructed during cataract surgery in 25 eyes of 24 children between 7 and 16 years of age. Absence of wound leak at the conclusion of surgery was taken as indicating a secure wound. Watertight wounds were achieved in 19 eyes, 11 of those in children older than 11. Six eyes demonstrated wound leak, and sutures had to be applied to achieve a secure wound. All wound leaks occurred in children younger than 11. Patients younger than 11 who underwent primary posterior capsulotomy and anterior vitrectomy had a significantly higher incidence of wound leak after sutureless cataract surgery (P < .001). We conclude that the self-sealing wound probably should not be used for cataract surgery in children younger than 11.

Adolescent↗

Sutureless end-to-end bowel anastomosis using an argon laser and water-soluble intraluminal stent.

Sutureless end-to-end intestinal anastomoses were constructed in New Zealand white rabbits using an argon laser to weld the tissue edges, which were temporarily held together by a biodegradable, water-soluble, intraluminal stent. Various power settings ranging from 1.5 to 5 W were used with and without an exogenous chromophore (India ink). Delivering 4 W of power without using an exogenous chromophore but applying a continuous saline drip to the anastomotic seam during lasing proved most successful. We conclude that argon laser energy can be used to construct successful sutureless end-to-end intestinal anastomoses.

Anastomosis, Surgical↗

Left ventricular pseudoaneurysm after sutureless repair of subacute left ventricular free wall rupture: a case report.

A 65-year-old woman presenting with a left ventricular pseudoaneurysm 27 months after sutureless repair of a subacute left ventricular free wall rupture complicating acute myocardial infarction is described. An autologous pericardial patch and gelatin resorcin formaldehyde (GRF) glue were used in the repair. A small pseudoaneurysm bulged out over the true aneurysm of the left ventricle. We performed a Dor operation and concomitant bypass grafting to the right coronary artery. Although sutureless repair is an effective procedure for subacute left ventricular free wall rupture, left ventricular pseudoaneurysm in the late postoperative period may be a rare problem after this repair.

Aged↗

[Unfolded intraocular lens implantation through a 6 mm sutureless incision].

OBJECTIVE: To evaluate the therapeuitic effects of phacoemusification and unfolded iutraoculavr lens (IOL) implantation through a 6 mm sutureless incision. METHODS: A 6 mm sclera tunnel incision was made at 12 o'clock tangent of the posterior limbus and unfolded polymethylmethacrylate(PMMA) IOL implantation was operated in 50 cases (55 eyes); 53 eyes were finished without suture after phacoemusification and 2 eyes were done with extra capsule cataract extration(ECCE) because of the broken posterior capsular. RESULTS: Postoperatively, the visual acuity was 0.6 or more in 92.4% of the eyes and 1.0 or more in 50.9% of the eyes at one week; 0.6 or more in 98.1% of the eyes and 1.0 or more in 67.9% of the eyes at one month. The mean postoperative astigmatism was 0.63 +/- 0.36 D at one week and 0.61 +/- 0.33 D at one month. There was no statistical difference between the mean preoperative astigmatism(0.60 +/- 0.48 D) and postoperative astigmatism at one week and one month (P > 0.05). CONCLUSION: The technique of phacoemusification and PMMA IOL implantation through a 6 mm sutureless incision can reduce early postoperative astigmatism, shorten the period of visual rehabilitation.

Aged↗