PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Tidal Volume”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

A strategy to optimise the performance of the mouth-to-bag resuscitator using small tidal volumes: effects on lung and gastric ventilation in a bench model of an unprotected airway.

When ventilating an unintubated patient with a standard adult self-inflating bag, high peak inspiratory flow rates may result in high peak airway pressures with subsequent stomach inflation. In a previous study we have tested a newly developed mouth-to-bag-resuscitator (max. volume, 1500 ml) that limits peak inspiratory flow, but the possible advantages were masked by excessive tidal volumes. The mouth-to-bag-resuscitator requires blowing up a balloon inside the self-inflating bag that subsequently displaces air, which then flows into the patient's airway. Due to this mechanism, gas flow and peak airway pressures are reduced during inspiration when compared with a standard bag-valve-mask-device. In addition, the device allows the rescuer to use two hands instead of one to seal the mask on the patient's face. The purpose of the present study was to assess the effects of the mouth-to-bag-resuscitator, which was modified to produce a maximum tidal volume of 500 ml, compared with a paediatric self-inflating bag (max. volume, 380 ml), and a standard adult self-inflating bag (max. volume, 1500 ml) in an established bench model simulating an unintubated patient with respiratory arrest. The bench model consisted of a face mask, manikin head, training lung (lung compliance, 100 ml/0.098 kPa (100ml/cm H2O); airway resistance, 0.39 kPa/(l s) (4 cm H2O/(l s)), and a valve simulating lower oesophageal sphincter pressure, 1.47 kPa (15 cm H2O). Twenty critical care nurses volunteered for the study and ventilated the manikin for 1 min with a respiratory rate of 20 min(-1) with each ventilation device in random order. The mouth-to-bag-resuscitator versus paediatric self-inflating bag resulted in significantly (P < 0.05) higher lung tidal volumes (302 +/- 41 ml versus 233 +/- 22 ml), and peak airway pressure (10 +/- 1 cm H2O versus 9 +/- 1 cm H2O), but comparable inspiratory time fraction (28 +/- 5% versus 27 +/- 5%, Ti/Ttot), peak inspiratory flow rate (0.6 +/- .01 l/s versus 0.6 +/- 0.2 l/s), and stomach inflation (149 +/- 495 ml/min versus 128 +/- 278 ml/min). In comparison with the adult self-inflating bag, there was significantly (P < 0.05) less gastric inflation (3943 +/- 4896 ml/min versus 149 +/- 495 ml/min versus 128 +/- 278 ml/min, respectively) with both devices, but the standard adult self-inflating bag had significantly higher lung tidal volumes (566 +/- 77 ml), peak airway pressure (13 +/- 1 cm H2O), and peak inspiratory flow rate (0.8 +/- 0.11 l/s). In conclusion, comparing the mouth-to-bag-resuscitator with small tidal volumes versus the paediatric self-inflating-bag during simulated ventilation of an unintubated patient in respiratory arrest resulted in comparable marginal stomach inflation, but significantly reduced the likelihood of gastric inflation compared to the adult self-inflating-bag. Lung tidal volumes were improved from approximately 250 ml with the paediatric self-inflating-bag to approximately 300 ml with the mouth-to-bag-resuscitator.

Adult↗

The effect of carbon dioxide, respiratory rate and tidal volume on human heart rate variability.

BACKGROUND: Heart rate variability (HRV) has been used for assessment of depth of anesthesia. Alterations in respiratory rate and tidal volume modulate the sympatovagal neural drive to the heart. The changes in PaCO2 that accompany changes in breathing pattern may, through chemoreceptors in the brainstem, independently influence the autonomic control of the heart and modulate HRV. METHODS: We measured the effects of PaCO2, tidal volume and respiratory rate on HRV during spontaneous and mechanical ventilation in 22 healthy volunteers and in 25 mechanically ventilated anesthetized patients. RESULTS: Adding CO2 to the inspiratory gas increased high frequency (HF) and low frequency (LF) components of HRV in awake volunteers both during spontaneous and mechanical ventilation, while this effect of CO2 was abolished in patients during anesthesia. Increase of tidal volume increased HF component of HRV only in volunteers during spontaneous ventilation. On the other hand, when respiratory rate was reduced, the balance of HF and LF power moved toward LF power in all study groups. Breathing frequency altered HRV independent on PaCO2, tidal volume and the level of consciousness. In contrast, the effect of PaCO2 appeared to be related to normal level of consciousness, suggesting that a cortical modulation of the autonomic nervous activity contributes to the effects of PaCO2 on HRV. CONCLUSIONS: PaCO2, tidal volume and respiratory rate should be controlled when HRV power spectrum is measured in conscious patients or volunteers, while in anesthetized patients small changes in end-tidal CO2 or tidal volume do not modulate HRV if respiratory rate remains unchanged.

Adult↗

Determinants of tidal volume during high-frequency oscillation.

OBJECTIVE: High-frequency oscillation has been proposed for use in adult acute respiratory distress syndrome. However, limited data are available on the effect of pressure amplitude and rate (Hz) on tidal volumes delivered during high-frequency oscillation in adults. DESIGN: Prospective, animal model, lung injury study. SETTING: Large-animal laboratory of a university-affiliated medical center. SUBJECTS: Nine sheep (29.2 +/- 2.4 kg). INTERVENTIONS: Severe lung injury was induced by repeated saline lung lavage. After stabilization, high-frequency oscillation was initiated at a mean airway pressure equal to the point of maximum curvature on the deflation limb of the pressure-volume curve (26 +/- 1.9 cm H2O). Tidal volume at all combinations of rates of 4, 6, 8, and 10 Hz, pressure amplitudes of 30, 40, 50, and 60 cm H2O, and inspiratory/expiratory ratios of 1:1 and 1:2 (using the Sensormedics 3100B oscillator) were measured. Flow was measured by a pneumotachometer, amplified and digitized at 1000 Hz. Three breaths were analyzed at each setting. MEASUREMENTS AND MAIN RESULTS: At both inspiratory/expiratory ratios, tidal volume was directly proportional to pressure amplitude and inversely proportional to frequency. During an inspiratory/expiratory ratio of 1:1, at 60 cm H2O pressure amplitude and 4 Hz, a tidal volume of 129.1 +/- 34.8 mL (4.4 +/- 1.2 mL/kg) was delivered. CONCLUSIONS: At low rates and high-pressure amplitudes in this model, tidal volumes approaching conventional mechanical ventilation can be delivered during high-frequency oscillation.

Analysis of Variance↗

Intracerebroventricular administration of the angiotensin II receptor antagonist saralasin reduces respiratory rate and tidal volume variability in freely moving Wistar rats.

The possible importance of intra-individual variations in respiratory rate and tidal volume has recently gained interest in psychiatric research, as a result of the observations that patients with panic disorder or premenstrual dysphoric disorder display enhanced respiratory variability as compared to controls. Although the role of brain neurotransmitters in the regulation of breathing has been extensively studied, as yet data on the central regulation of respiratory variability is sparse. Prompted by previous studies indicating that angiotensin II (ANG II) may influence ventilation as well as anxiety, we have studied the effect of intracerebroventricular administration of an ANG II receptor antagonist, saralasin, on respiratory variability in unrestrained, freely moving male Wistar rats. Treatment with saralasin, 5 mug dissolved in 1 mul saline followed by 9 mul saline in each lateral cerebral ventricle, did not influence tidal volume, but markedly reduced tidal volume variability (p=0.0005), as compared to saline injections (10 mul). Respiratory rate was reduced by saralasin (p=0.02), and there was also a non-significant tendency for a reduction in respiratory rate variability. Both minute volume (p=0.005) and volume/10 s variability (p=0.0006) were reduced. It is suggested that ANG II in the brain of Wistar rats may regulate respiratory rate and tidal volume variability.

Angiotensin Receptor Antagonists↗

Tidal volumes which are perceived to be adequate for resuscitation.

Observers trained in basic life support assessed chest rise in 34 patients who were anaesthetised and paralysed and whose lungs were being mechanically ventilated prior to routine surgery. Making 67 independent assessments, the observers indicated the tidal volume that they considered produced adequate chest rise for resuscitation. The mean tidal volume perceived to be adequate was 384 ml with 95% confidence limits of 362-406 ml. The perceived volumes correlated with the Body Mass Index. Guidelines by various authorities recommend that tidal volumes sufficient to make the chest rise normally should be used during resuscitation. The volumes perceived as adequate by the observers are much lower than the numerical values recommended by the American Heart Association (800-1200 ml). High tidal volumes are associated with an increased risk of gastric regurgitation in patients with an unprotected airway, CO2 delivery to the lungs is likely to be low during cardiac arrest obviating the need for high tidal volumes. In the light of present knowledge and the findings in this study, we would recommend that resuscitation training manikins are recalibrated to indicate satisfactory ventilation at tidal volumes of 400-600 ml. These volumes should reduce the risk of gastric inflation and permit more chest compressions to be carried out in a minute because the ventilation fraction of the CPR sequence is shorter. Adequate CO2 elimination should still be assured.

Adult↗

A high positive end-expiratory pressure, low tidal volume ventilatory strategy improves outcome in persistent acute respiratory distress syndrome: a randomized, controlled trial.

OBJECTIVE: It has been shown in a two-center study that high positive end-expiratory pressure (PEEP) and low tidal volume (LTV) improved outcome in ARDS. However, that study involved patients with underlying diseases unique to the study area, was conducted at only two centers, and enrolled a small number of patients. We similarly hypothesized that a ventilatory strategy based on PEEP above the lower inflection point of the pressure volume curve of the respiratory system (Pflex) set on day 1 with a low tidal volume would result in improved outcome in patients with severe and persistent acute respiratory distress syndrome (ARDS). DESIGN: Randomized, controlled clinical trial. SETTING: Network of eight Spanish multidisciplinary intensive care units (ICUs) under the acronym of ARIES (Acute Respiratory Insufficiency: España Study). PATIENTS: All consecutive patients admitted into participating Spanish ICUs from March 1999 to March 2001 with a diagnosis of ARDS were considered for the study. If 24 hrs after meeting ARDS criteria, the Pao2/Fio2 remained < or =200 mm Hg on standard ventilator settings, patients were randomized into two groups: control and Pflex/LTV. INTERVENTIONS: In the control group, tidal volume was 9-11 mL/kg of predicted body weight (PBW) and PEEP > or =5 cm H2O. In the Pflex/LTV group, tidal volume was 5-8 mL/kg PBW and PEEP was set on day 1 at Pflex + 2 cm H2O. In both groups, Fio2 was set to maintain arterial oxygen saturation >90% and Pao2 70-100 mm Hg, and respiratory rate was adjusted to maintain Paco2 between 35 and 50 mm Hg. MEASUREMENTS AND MAIN RESULTS: The study was stopped early based on an efficacy stopping rule as described in the methods. Of 103 patients who were enrolled (50 control and 53 Pflex), eight patients (five in control, three in Pflex) were excluded from the final evaluation because the random group assignment was not performed in one center according to protocol. Main outcome measures were ICU and hospital mortality, ventilator-free days, and nonpulmonary organ dysfunction. ICU mortality (24 of 45 [53.3%] vs. 16 of 50 [32%], p = .040), hospital mortality (25 of 45 [55.5%] vs. 17 of 50 [34%], p = .041), and ventilator-free days at day 28 (6.02 +/- 7.95 in control and 10.90 +/- 9.45 in Pflex/LTV, p = .008) all favored Pflex/LTV. The mean difference in the number of additional organ failures postrandomization was higher in the control group (p < .001). CONCLUSIONS: A mechanical ventilation strategy with a PEEP level set on day 1 above Pflex and a low tidal volume compared with a strategy with a higher tidal volume and relatively low PEEP has a beneficial impact on outcome in patients with severe and persistent ARDS.

Adult↗

Tidal volume and frequency dependence of carbon dioxide elimination by high-frequency ventilation.

Six patients with chronic respiratory failure received mechanical ventilation with tidal volumes less than or equal to the dead-space volume, at frequencies of 30 to 900 breaths per minute. The rate of elimination of carbon dioxide from the ventilator system during a brief trial of high-frequency ventilation accurately predicted the long-term effectiveness of a given combination of frequency and tidal volume. Below frequencies of about 200 breaths per minute, the volume of carbon dioxide eliminated from these patients was most strongly related to the product of frequency and tidal volume; at higher frequencies, carbon dioxide elimination was determined by the tidal volume and was independent of frequency. These results suggest that although the effectiveness of high-frequency ventilation is primarily a function of the product of tidal volume and frequency, above a critical frequency the mechanical characteristics of the lung reduce gas transport by limiting the volume transmitted to the periphery of the lung.

Adolescent↗

Variability of breath-by-breath tidal volume and its characteristics in normal and diseased subjects. Ventilatory monitoring with electrical impedance pneumography.

To assess clinical significance of breath-by-breath variation of tidal volume and its distribution pattern displayed as a histogram, continuous measurement of tidal volume was made with electrical impedance pneumography for about 60 minutes. Subjects were composed of 26 normal male and 46 patients including 17 patients with restrictive lung disease and 29 patients with obstructive lung disease. To evaluate variation of tidal volume quantitatively, coefficient of variance (C.V.) was used. In comparison to the normal pattern of distribution (C.V. = 26.0 +/- 7.5%, mean +/- S.D.), patients with restrictive lung disease showed extremely narrow pattern of the distribution and significantly smaller C.V. (17.5 +/- 4.6% in old pulmonary tuberculosis, P less than 0.005 and 18.9 +/- 9.3% in pneumonitis, P less than 0.025). Whereas, patients with obstructive lung disease showed widespread pattern of the distribution and significantly greater C.V. (43.2 +/- 13.0% in pulmonary emphysema with hypercapnia, 33.0 +/- 7.5% in normocapnia and 35.8 +/- 9.4% in asthmatic attack, P less than 0.005). In all the patients with bronchial asthma after the treatment, the extremely widespread pattern of histogram was returned toward the normal one and the C.V. was decreased (22.4 +/- 6.4%). It was suggested that the distribution pattern of tidal volume was affected by the change of clinical condition, and was well correlated to the pathophysiological process related to restrictive or obstructive lung disease. We conclude that analysis of tidal volume distribution by the histogram is one of the useful approach to manage patients with respiratory diseases.

Adult↗

The measurement of tidal volumes in spontaneously breathing children during general anaesthesia using a Haloscale infant Wright respirometer.

The accuracy of tidal volume measurements made with a Wright Haloscale infant respirometer in children breathing spontaneously during general anaesthesia was assessed by a bench test. The tidal volumes and peak flow rates of 20 spontaneously breathing, anaesthetised children were measured with a pneumotachograph before and during surgery, and similar volumes, at the same flow rates, were delivered by a calibrated syringe simultaneously to the respirometer and a pneumotachograph. The results reveal that the mean (+/- s.d.) peak gas flow rates of children aged 6 years and less, 7.5 (+/- 1.6) and 9.3 (+/- 0.1) l/min before surgery and during surgery respectively, are significantly less than the peak flow rates, 11.3 (+/- 1.0) and 11.9 (+/- 1.5) before and during surgery, respectively, of children aged more than 6 years; and that the respirometer underestimates tidal volume by 10% when the peak flow rate is 11 l/min, and the percentage error in tidal volume estimation by the respirometer increases as the peak gas flow declines below 10 l/min.

Adolescent↗

Effects of inhaled alpha 2-adrenoceptor and GABAB receptor agonists on citric acid-induced cough and tidal volume changes in guinea pigs.

The effects of alpha 2-adrenoceptor and GABA receptor agonists on citric acid-induced cough and increased tidal volume were investigated in conscious guinea pigs. Inhalation of low doses of B-HT 920 (5-allyl-2-amino 5,6,7,8-tetrahydro-4H-thiazolo[4,5-d]azepine dihydrochloride), and xylazine significantly inhibited citric acid-induced cough and tidal volume increases. Intraperitoneal administration of higher doses of B-HT 920 than those given by aerosol were ineffective. The inhibitory effects of B-HT 920 were antagonised by prior intraperitoneal administration of yohimbine, but not atropine. Inhalation of GABA or baclofen inhibited tidal volume increases, but had no effect on cough. Inhaled alpha 2-adrenoceptor or GABA agonists had no effect on the reduced respiratory rate after citric acid inhalation. It is concluded that alpha 2-adrenoceptor agonists inhibit cough via a mechanism which may not be related to their ability to reduce citric acid-induced tidal volume increases, since GABA and baclofen inhibited tidal volume increases but not cough. We suggest that alpha 2-adrenoceptor agonists may have therapeutic potential in the treatment of cough.

Acetylcholine↗

Experimental evaluation of the optimal tidal volume for simultaneous pacing of the diaphragm and respiratory muscles.

Because of problems with pacing devices, surgical procedures, and diaphragm fatigue in pacing therapy of the phrenic nerve, we performed simultaneous pacing of the diaphragm alone and of multiple respiratory muscles in dogs and evaluated the optimal tidal volume. After intravenously anesthetizing 20 dogs with an average weight of 11 kg, their tidal volume was measured with a spirometer to obtain control values. In the first 4 dogs, electrodes were sutured to the diaphragm and the optimal voltage, pulse width, and output to maximize tidal volume were determined. In the remaining 16 dogs, we stimulated individual canine respiratory muscles, i.e., the diaphragm, the rectus thoracis, and intercostal muscles 3-5 and simultaneously stimulated the diaphragm and the rectus thoracis; the diaphragm and intercostal muscles; the rectus thoracis and the intercostal muscles; or the diaphragm, rectus thoracis, and intercostal muscles. We compared a group in which a counterelectrode was positioned in each muscle group (group A) with a group in which no counterelectrode was used (group B). The best tidal volume was obtained at 10 V, 50 Hz, and a pulse width of 1.0 ms. All the respiratory muscle pacings yielded better tidal volumes in group B than in group A. The greatest tidal volume was obtained with the rectus thoracis and intercostal muscle combination, suggesting the possibility of being able to reduce diaphragm fatigue by alternate pacing of these muscles and the diaphragm.

Animals↗

Lower tidal volume ventilation and plasma cytokine markers of inflammation in patients with acute lung injury.

OBJECTIVES: To evaluate the association between interleukin-6, interleukin-8, and interleukin-10 and clinical outcomes including mortality in patients with acute lung injury and to determine whether lower tidal volume ventilation was associated with a decrease in plasma cytokines in patients with acute lung injury. DESIGN: Multiple-center, randomized trial. SETTING: Intensive care units in ten university centers. PATIENTS: The study included 861 patients enrolled in the National Heart, Lung and Blood Institute Acute Respiratory Distress Syndrome Clinical Network trial of lower tidal volumes compared with traditional tidal volumes for acute lung injury. INTERVENTIONS: Patients were randomized to a 6 mL/kg or a 12 mL/kg tidal volume strategy that has been previously described. MEASUREMENTS AND MAIN RESULTS: Baseline plasma levels of interleukin-6, interleukin-8, and interleukin-10 were each associated with an increased risk of death in both logistic regression analyses controlling for ventilator group (odds ratio 1.63 per log-10 increment, 95% confidence interval 1.33-1.98; odds ratio 2.33 per log-10 increment, 95% confidence interval 1.79-3.03; odds ratio 2.02 per log-10 increment, 95% confidence interval 1.47-2.76, respectively) and multivariate analyses controlling for ventilation strategy, Acute Physiology and Chronic Health Evaluation III score, Pao2/Fio2 ratio, creatinine, platelet count, and vasopressor use (odds ratio 1.63 per log-10 increment, 95% confidence interval 0.93-1.49; odds ratio 1.73 per log-10 increment, 95% confidence interval 1.29-2.34; odds ratio 1.23 per log-10 increment, 95% confidence interval 0.86-1.76, respectively). Interleukin-6 and interleukin-8 levels were also associated with a significant decrease in ventilator free and organ failure free days. Patients with sepsis had the highest cytokine levels and the greatest risk of death per cytokine elevation. By day 3, the 6 mL/kg strategy was associated with a greater decrease in interleukin-6 and interleukin-8 levels. There was a 26% reduction in interleukin-6 (95% confidence interval, 12-37%) and a 12% reduction in interleukin-8 (95% confidence interval, 1-23%) in the 6 mL/kg group compared with the 12 mL/kg group. CONCLUSIONS: In patients with acute lung injury, plasma interleukin-6 and interleukin-8 levels are associated with morbidity and mortality. The severity of inflammation varies with clinical risk factor, suggesting that clinical risk factor should be considered when both developing and testing therapeutic interventions. Low tidal volume ventilation is associated with a more rapid attenuation of the inflammatory response.

APACHE↗

Effects of half the tidal volume during cardiopulmonary resuscitation on acid-base balance and haemodynamics in pigs.

The effects of half the tidal volume during cardiopulmonary resuscitation (CPR) on haemodynamics, acid-base balance, and oxygenation were studied in anaesthetized pigs. The animals were ventilated with a mean tidal volume of 12.5 +/- 0.5 ml/kg at a rate of 14/minute resulting in a mean arterial pCO2 of 40 +/- 3 mmHg. They were randomly assigned to two groups: in one group ventilation was performed with half the pre-arrest tidal volume (50% group; n = 9), in the other group ventilation remained unchanged during CPR (100% group; n = 10). After 8 minutes of CPR attempts were made to restore spontaneous circulation with epinephrine and countershocks. There were no differences in advanced life support requirements, haemodynamic parameters, and resuscitability between the two groups. During CPR up to 5 minutes after restoration of spontaneous circulation (ROSC) dead space ventilation was significantly higher in the 50% group compared with the 100% group (p < 0.05). During CPR (at 3 and 7 minutes) arterial pO2 values were significantly lower (218 +/- 136 and 221 +/- 120 mmHg vs. 381 +/- 130 and 352 +/- 147 mmHg; FiO2 1.0) and hyperventilation was less pronounced (34.4 +/- 7.3 and 31.3 +/- 7.7 mmHg vs. 26.2 +/- 5.6 and 26.9 +/- 6.3 mmHg) in the 50% group. Our results suggest that half the tidal volume during CPR is likely to establish a more physiological acid-base balance and has no adverse effects on haemodynamics in intubated pigs ventilated with pure oxygen.

Acid-Base Equilibrium↗

Techniques of emergency ventilation: a model to evaluate tidal volume, airway pressure, and gastric insufflation.

We designed a model to evaluate the effectiveness of various noninvasive methods of ventilation. The upper airway was simulated with the head of a Resusci-Annie which was attached to a test lung. The esophagus and stomach were simulated with a Penrose drain connected to a rolling seal spirometer via a PEEP valve. Fifteen paramedic volunteers ventilated the model utilizing mouth-to-mouth, mouth-to-mask, bag-valve-mask, or portable field ventilator (Impact or HARV). Recording of tidal volume, gastric volume, and proximal and distal airway pressure was completed at three different levels of compliance. At normal compliance, all methods except the HARV met or exceeded American Heart Association standards. As compliance decreased, tidal volume fell and gastric insufflation increased. At a compliance of 0.02 L/cm H2O all methods failed to meet AHA standards and gastric insufflation volume equalled delivered tidal volumes for mouth-to-mouth and mouth-to-mask techniques. Mouth-to-mouth and mouth-to-mask techniques generated the largest tidal volumes but also created the largest volume of gastric insufflation. The Impact ventilator provided an acceptable tidal volume with minimal gastric insufflation. Our results suggest that mouth-to-mask ventilation with supplemental oxygen enrichment is the most efficient technique for non-invasive airway management.

Airway Resistance↗

Low tidal volume reduces epithelial and endothelial injury in acid-injured rat lungs.

Using a rat model of acid-induced lung injury, we tested the hypothesis that tidal volume reduction at the same level of PEEP (10 cm H(2)O) would diminish the degree of pulmonary edema by attenuating injury to the alveolar epithelial and endothelial barriers. Tidal volume reduction from 12 to 6 to 3 ml/kg significantly reduced the rate of lung water accumulation from 690 microl/h to 310 microl/h to 210 microl/h. Ventilation with either 6 or 3 ml/kg reduced endothelial injury equally as measured by plasma vWf:Ag and permeability to albumin. Plasma RTI40, a marker of type I epithelial cell injury, decreased 46% when tidal volume was reduced from 12 to 6 ml/kg and decreased an additional 33% with 3 ml/kg (p < 0.05). The rate of alveolar epithelial fluid clearance was significantly faster in the 3-ml/kg group (24 +/- 7%/h) compared with 6 ml/kg (15 +/- 11%/h) and 12 ml/kg (3 +/- 6%/h). We conclude that low tidal volume ventilation protects both the alveolar epithelium and the endothelium in this model of acute lung injury. The additional decrease in pulmonary edema with a tidal volume of 3 ml/kg is partly accounted for by greater protection of the alveolar epithelium.

Animals↗

Measurement of tidal volume by using transthoracic impedance variations in rats.

The application of impedance pneumography for monitoring respiration in small animals has been limited by problems with calibration. With improved instrumentation, we describe the calibration of tidal volume in anesthetized rats. The detection of changes in voltage, reflecting the electrical impedance variations associated with respiration, was optimized by using disposable adhesive silver-silver chloride electrodes, advanced circuitry, and analog-to-digital recording instrumentation. We found a linear relationship between change in impedance and tidal volume in individual rats (R2 >/= 98%), which was strongly influenced by rat weight. Consequently, a calibration equation incorporating change in impedance and rat weight was derived to predict tidal volume. Comparison of the predicted and true tidal volumes revealed a mean R2 >/= 98%, slopes of approximately 1, intercepts of approximately 0, and bias of approximately 0.07 ml. The predicted volumes were not significantly affected by either frequency of respiration or pulmonary edema. We conclude that impedance pneumography provides a valuable tool for the noninvasive measurement of tidal volume in anesthetized rats.

Analog-Digital Conversion↗

High tidal volume ventilation induces lung injury after hepatic ischemia-reperfusion.

Ischemia-reperfusion not only damages the affected organ but also leads to remote organ injuries. Hepatic inflow interruption usually occurs during hepatic surgery. To investigate the influence of liver ischemia-reperfusion on lung injury and to determine the contribution of tidal volume settings on liver ischemia-reperfusion-induced lung injury, we studied anesthetized and mechanically ventilated rats in which the hepatic inflow was transiently interrupted twice for 15 min. Two tidal volumes, 6 ml/kg as a low tidal volume (IR-LT) and 24 ml/kg as a high tidal volume (IR-HT), were assessed after liver ischemia-reperfusion, as well as after a sham operation, 6 ml/kg (NC-LT) and 24 ml/kg (NC-HT). Both the IR-HT and IR-LT groups had a gradual decline in the systemic blood pressure and a significant increase in plasma TNF-alpha concentrations. Of the four groups, only the IR-HT group developed lung injury, as assessed by an increase in the lung wet-to-dry weight ratio, the presence of significant histopathological changes, such as perivascular edema and intravascular leukocyte aggregation, and an increase in the bronchoalveolar lavage fluid TNF-alpha concentration. Furthermore, only in the IR-HT group was airway pressure increased significantly during the 6-h reperfusion period. These findings suggest that liver ischemia-reperfusion caused systemic inflammation and that lung injury is triggered when high tidal volume ventilation follows liver ischemia-reperfusion.

Animals↗

Subjective and objective measurement of tidal volume in critically ill patients.

Subjective assessment of the respiratory rate and the adequacy of tidal ventilation are the oldest and most widely practiced forms of respiratory monitoring in critically ill patients. Surprisingly, this method of assessment has itself never been evaluated in patients. The estimation of tidal volume in nine patients was performed by full-time intensive care unit (ICU) personnel and compared to the objective measurement of using a calibrated and validated respiratory inductive plethysmograph (RIP). Linear correlation analysis was performed. Poor correlation between clinical estimation by ICU personnel and actual measurement by RIP was revealed in all cases. A widespread and potentially dangerous tendency to overestimate tidal volume was noted. These data suggest that subjective assessment of tidal volume is inaccurate in critically ill patients and that the development of techniques of continuous, nonobtrusive and objective monitoring are to be encouraged.

Acute Disease↗