PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Ventilators, Negative-Pressure”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

[Hemodynamic study of negative pressure ventilation using diaphragm pacing].

A negative pressure ventilation (NPV) by unilateral or bilateral diaphragm pacing (DP) was prepared for canine experiments. A shift from positive pressure ventilation (PPV) to NPV resulted in elevation of mean aortic pressure, increase in stroke volume and depression of mean pulmonary arterial pressure. Examination of the interaction between respiratory cycle and cardiac function during PPV, disclosed a reduction of right ventricular stroke volume and elevation of mean aortic and right ventricular end-diastolic pressure at end inspiration, compared to those at end expiration. During NPV with DP, left ventricular stroke volume, heart rate and mean aortic pressure were increased immediately after DP (immediately after inspiration) compared to those at end expiration. The experimental model of DP, in which respiratory condition could be easily altered, was considered to be useful to evaluate the effect of NPV on cardiac function.

Animals↗

[Right ventricle support after lung resection].

It is very important to establish a method of determining the influence of lung resection on right ventricular function and to devise some therapeutic methods of supporting the right ventricle. However, there has been no systematic research on these issues. We found that echocardiographic demonstrated abnormal motion of the ventricular septum after right pneumonectomy and of the left ventricular wall after left pneumonectomy. We developed a triggered cuirass respirator and showed that it could support the right heart after a lung resection. We also found that the injection of SF6 Gas into the postpneumonectomy pleural space might be useful in supporting the right heart after a pneumonectomy.

Adult↗

[The effect of body respirator on the desaturation during the night in Duchenne muscular dystrophy].

Recently body respirator (BR) has been used to control respiratory failure in patients with late stage Duchenne muscular dystrophy (DMD). We examined the effect of BR using a pulse oximeter. Arterial oxygen saturation (SaO2) for the night (21:00-7:00) was monitored in 15 DMD patients (5 cases without BR, 3 cases with BR partially for the night and 6 cases with BR all night long) and the desaturation (SaO2 less than 90%) time was followed three times (Jan. '87, Nov. '87, Apr. '88) in each patient. Desaturation time did not increase in 4 cases without BR. But in one case without BR it increased so much that we decided to put the patient on BR. In 3 cases with BR partially for the night, desaturation was well controlled when they used BR. No marked increase of desaturation was found in 4 cases with BR all night long. 2 of these cases were changed from cuirass type BR to jacket type BR and were getting on satisfactorily. Thoracic cage expansion of jacket type was larger than that of cuirass type, and it was found that jacket type was valuable. Also, we investigated the cause of desaturation by recording SaO2, nasal flow, thoracic cage motion and abdominal motion at the same time by making use of a polygraphy. The result showed that the main cause of desaturation was the resistance of thoracic cage motion against BR. And we think research and development is needed.

Adolescent↗

[General introduction to the clinical application of non-invasive respiratory aids].

Intermittent positive pressure ventilation via tracheostomy has been the most common method of providing ventilatory support for patients with respiratory failure since the late 1950s. It is the standard procedure for individuals who suffer from acute respiratory failure, impaired consciousness, and severe restrictive lung disease. However, numerous adverse complications from these invasive techniques have been reported in those who are long-term ventilator users. This paper describes the evolution and current application of non-invasive respiratory aids in both acute and long-term settings. The respiratory function can be aided by applying forces to the body or intermittent pressure to the air ways. The devices are negative pressure body ventilators which act on the body by creating negative pressure around the thorax and abdomen such devices effectively maintain the ventilation of individuals with respiratory failure, but have the shortcomings of bulkiness, high expense, and limitation on the users' activities. The non-invasive positive pressure ventilator applies intermittent pressure directly to the airway by a non-invasive interface; namely mouthpiece, nasal, or face masks. In this way, it can prevent patients from requiring either tracheostomy or endotracheal tube, but is not effective enough to ventilate patients with markedly decreased lung compliance because the high airway resistance provides air leakage from the non-invasive interface. Non-invasive respiratory aids should be the first choice to maintain ventilation for patients with respiratory failure secondary to neuromuscular disorder, because of their benefits of easy application, satisfactory results, fewer complications and early active rehabilitation. Increased understanding of non-invasive respiratory aids should assist in the management of patients with chronic respiratory failure.

Humans↗

External negative pressure ventilation techniques.

External ventilation was introduced at the beginning of the century to treat acute and chronic respiratory failure. Long-term negative pressure ventilation (NPV) has proved useful in patients with respiratory failure, secondary to a restrictive impairment of neuromusculoskeletal origin. Although NPV may be successfully used in acute-on-chronic respiratory failure in patients with chronic airflow obstruction (CAO), its use in the long-term management of this type of patient seems much less promising. The various types of ventilators, iron lung, pneumo-wrap and cuirass are discussed. All these prostheses, except for the pneumo-wrap, are connected to a pump able to generate negative and positive pressure. NPV must be a controlled ventilation, because an effective trigger is not yet available. The most important feature of the ventilator must be the ability to vary the ventilatory pattern to adapt the machine drive to the patient drive. The goal of NPV is not only to normalize gas exchange, but also to restore an effective spontaneous ventilation. This kind of ventilation has no negative effects on haemodynamics, because it does not vary physiological gradients of transthoracic pressure. However, due to lack of coordination between the respirator and the pharyngeal muscles of the patient, obstructive apnoeas may occur during NPV in sleeping patients.

Humans↗

Home mechanical ventilation.

Recently, interest in the use of mechanical ventilation outside the hospital setting has been increasing. Patients with various types of chronic respiratory failure may benefit from this approach. Evaluation for long-term mechanical ventilation necessitates assessment of the underlying disease process, the goals of the medical team, and the needs of the patient and family. Externally applied negative-pressure devices can provide adequate ventilation for many patients, particularly those with neuromuscular diseases. Positive-pressure ventilation by means of a tracheostomy provides greater control of the airway, allows adjustment of tidal volume and minute ventilation, and may be delivered by portable equipment. Ongoing care and support services in the home must be provided. A variety of mechanical devices and new techniques of ventilator support have made home mechanical ventilation a realistic option for long-term care.

Adult↗

Historical perspectives on the development and use of mechanical ventilation.

Contemporary advancements in cardiothoracic and abdominal surgical procedures have been historically dependent on the development and adoption of controlled airway management, specifically endotracheal intubation, controlled positive-pressure ventilation, and the use of automatic positive-pressure mechanical ventilators. More than 400 years elapsed before the 16th Century theories of Paracelsus and the demonstrations of Vesalius were routinely adopted to solve the "pneumothorax problem" that prevented complicated or prolonged surgical procedures within the pleural cavity. Acceptance and implementation of controlled positive-pressure ventilation was impeded for decades by the inability to maintain and protect the airway. Consequently, emphasis on the development of mechanical ventilation was directed toward machinery that provided safer negative-pressure respiratory support. The introduction of curare into European anesthesia practice and the adoption of protective airway practices during the poliomyelitis epidemics led to routine use of controlled positive-pressure ventilation and construction of dependable machinery. Laboratory investigations, exploring complications from cardiothoracic surgery, brought about American acceptance and established controlled positive-pressure mechanical ventilation as an indispensable part of conventional intraoperative management.

Europe↗

Ventilatory responses to increased blood flow and decreased lung volume in awake dogs.

The effect of decreased lung volume on ventilatory responses to arteriovenous fistula-induced increased cardiac output was studied in four chronic awake dogs. Lung volume decreases were imposed by application of continuous negative-pressure breathing of -10 cmH2O to the trachea. The animals were surgically prepared with chronic tracheostomy, indwelling carotid artery catheter, and bilateral arteriovenous femoral shunts. Control arteriovenous blood flow was 0.5 l/min, and test flow level was 2.0 l/min. Arterial blood CO2 tension (PaCO2) was continuously monitored using an indwelling Teflon membrane mass spectrometer catheter, and inhaled CO2 was given to maintain isocapnia throughout. Increased fistula flow alone led to a mean 52% increase in cardiac output (CO), whereas mean systemic arterial blood pressure (Psa) fell 4% (P less than 0.01). Negative-pressure breathing alone raised Psa by 3% (P less than 0.005) without a significant change in CO. Expired minute ventilation (VE) increased by 27% (P less than 0.005) from control in both of these conditions separately. Combined increased flow and negative pressure led to a 50% increase in CO and 56% increase in VE (P less than 0.0025) without any significant change in Psa. Effects of decreased lung volume and increased CO appeared to be additive with respect to ventilation and to occur under conditions of constant PaCO2 and Psa. Because both decreased lung volume and increased CO occur during normal exercise, these results suggest that mechanisms other than chemical regulation may play an important role in the control of breathing and contribute new insights into the isocapnic exercise hyperpnea phenomenon.

Animals↗

Negative pressure artificial respiration: use in treatment of respiratory failure of the newborn.

Ninety-one infants with respiratory failure secondary to primary pulmonary disease and with a birth weight of 1000 g. or over have been managed in a negative-pressure respirator (Air-Shields) over a three-year period. Of these the failure in 87 was due to respiratory distress syndrome (RDS) and in four it resulted from massive meconium aspiration. Respiratory failure was indicated initially by arterial blood gas tensions (while breathing 100% O(2)) of Po(2) <40 mm. Hg, pH <7.10 and Pco(2) >75 mm. Hg in the initial 47 cases; these levels were subsequently raised to Po(2) < 50 mm. Hg, pH <7.20 and Pco(2) >70 mm. Hg for the remainder. Fifty-four (59.3%) of the infants survived the use of the respirator and 47 of these (51.6%) were subsequently discharged alive and well. Mean time in hours to normalization of blood gas values while on the respirator were as follows: for Po(2), 10.5; for pH, 11.6; and for Pco(2), 22.6. These values indicate that the respirator is more efficient in promoting oxygenation (raising Po(2)) than ventilation (lowering Pco(2)). They also suggest that the observed acidosis is in large part secondary to the hypoxia rather than the result of co(2) retention. For the survivors the average time of total respirator dependency before commencement of weaning was 53.7 hours. All the infants were managed without the use of endotracheal tubes although the use of the respirator and/or administration of 100% oxygen were either continuous or intermittent for periods of up to two weeks. There have been no instances of so-called respirator lung disease in the survivors or in those who died, which suggests that the use of high oxygen concentration by itself is not the major factor in the pathogenesis of this complication.

Age Factors↗

[Hypoventilation due to disconnection of the vaporizer and negative-pressure leak test to find disconnection].

Most of Ohmeda anesthesia machines have a outlet check valve located in the low-pressure circuit, and this influences the type of leak test greatly. We report a case of hypoventilation due to a gas leakage from the junction of two vaporizers, Fluotec 3 and Enfluratec of Ohio 30/70. This gas leakage was not discovered preoperatively by performing traditional leak test of squeezing the bag filled with oxygen. Following intubation of the trachea the patient was paralyzed and mechanically ventilated. Her vital signs were stable and operation was started. Soon thereafter, she became hypertensive in spite of increases in concentration of enflurane and supplemental doses of fentanyl and diltiazem. ETCO2 showed 7.4% and spontaneous respiration started. We checked anesthesia machine and found a gas leakage at the junction of two vaporizers. Anesthesia machine was exchanged. The remainder of the procedure was uneventful and the patient showed a normal recovery. The outlet check valve closes when back-pressure is exerted on it, and a vulnerable area including flow tubes and vaporizers is not tested by the traditional positive-pressure leak test squeezing bag. Ohmeda recommends the use of a negative pressure leak test with suction bulb device. We propose manufacturers to place a cation on anesthesia machine such as -- "Negative-pressure leak test is inevitable because of presence of outlet check valve."

Anesthesiology↗

Positive- and negative-pressure breathing in newborn rat before and after anesthesia.

We have examined the effects of changes in functional residual capacity (FRC), determined by positive and negative body surface pressures, on the breathing pattern of intact newborn rats, before and after barbiturate anesthesia. With distending pressures (between 1 and 4 cmH2O) minute ventilation decreased mainly due to a prolongation of the expiratory time. This response was more marked after anesthesia and accompanied by a fall in tidal volume. The time of peak expiratory flow (TE'), an index of expiratory flow resistance, was not changed before anesthesia and only slightly decreased after anesthesia. With collapsing pressures between 1 and 2 cmH2O only small changes in breathing pattern occurred, whereas the TE' increased in all cases and the flow profile indicated a maintenance of lung volume during expiration. These data indicate that tonic vagal information is present in the newborn rat and is substantially enhanced after barbiturates. The result that changes in breathing pattern are not fully matched by the changes in TE' and expiratory flow profile may indicate that the receptors which control the respiratory pattern are not the same as those involved in the regulation of the expiratory flow. The pressure-volume curve of the respiratory system was similar before and after anesthesia, and the intercept was close to the zero pressure value, indicating that the FRC of the newborn rat, differently from the human baby, is not actively maintained above the resting volume of the system.

Anesthesia↗

Reflex effects and receptor responses to upper airway pressure and flow stimuli in developing puppies.

We studied the changes in breathing pattern due to pressure and airflow stimuli applied to isolated upper airway in nine 1- to 14-day-old and six 29- to 35-day-old anesthetized puppies breathing through a tracheostomy. Negative-pressure and flow, both inspiratory and expiratory, altered the breathing pattern only in the 1- to 14-day-old puppies, whereas positive pressure was ineffective in both age groups. Negative pressure caused apnea in 12% of the trials, expiratory flow in 18%, and inspiratory flow in 21%. When apnea did not occur there was a significant prolongation of inspiratory and expiratory time and a decrease of tidal volume of the first breath following the application of negative pressures. Section of the superior laryngeal nerves abolished the responses to pressure and flow. In nine 1- to 14-day-old and four 29- to 35-day-old puppies we recorded the activity of single units of the superior laryngeal nerves. We identified specialized receptors responding to pressure (68.5%), flow (2.7%), and contraction of upper airway muscles (drive, 28.8%). All types of receptors had a prevalent inspiratory-related activity. In the younger age group the discharge rate of pressure receptors at comparable negative pressures was lower than in older puppies. The strong inhibitory influences originating from the upper airway in the early stages of development presumably reflect different integrative properties of the central nervous system.

Animals↗

Atrial receptors and renal function.

The hypothesis that receptors in the heart or pulmonary vasculature initiate a reflex that influences urine flow was derived from experiments designed to evaluate the effect of mechanical ventilation on renal function. These experiments indicated that urine flow usually decreases during positive-pressure breathing and usually increases during negative-pressure breathing. It was surmised that impulses from certain cardiopulmonary receptors affect the secretion of ADH, which in turn influences urine flow. A subsequent investigation appeared to localize the pertinent receptors to the left atrium, but the results of this particular investigation were influenced by several complication factors that have not been widely appreciated. The apparent localization of volume-regulating recpetors to the left atrium and the accumulating evidence that atrial receptors do respond to changes in atrial pressure or atrial volume triggered a myriad of further studies on the function of left receptors. Nearly all these studies employed indirect techniques that produced changes in systemic and pulmonary hemodynamics in addition to changes in left atrial pressure. Nevertheless, it often was assumed that if changes in left pressure were produced, any concomitant changes in circulating ADH or in urine flow were attributable to a reflex elicited from atrial receptors. Mush of the data obtained were interpreted as being compatible with the elft atrial volume-receptor hypothesis, but very liggle of the data pertained to left atrial receptors specifically.

Animals↗

Maximal static pressures and lung volumes in a child with Guillain-Barré syndrome ventilated by a cuirass respirator.

Serial maximal static pressure and lung volume measurements were made in a child with Guillain-Barré syndrome and respiratory failure. The patient received successfully ventilatory support for seven weeks with the use of a cycled negative-pressure cuirass-type respirator obviating prolonged intubation and tracheostomy. The fall in VC preceded the loss of respiratory muscle strength (RMS) and lagged behind RMS in the return towards normal values. There was a disproportionate loss of lung volume (lowest VC, 220 to 250 ml, 11 to 12 percent of normal) as compared to maximal static pressures (lowest PImax, 60 cm H2O, lowest PEmax, 47 cm H2O). The disproportion was greater than that previously reported in adults. The greater loss in lung volume may be due to greater chest wall compliance in the child, resulting in less outward recoil of the chest wall and subsequently more microatelectasis with denervation of the chest wall musculature. Loss of lung volume resulted in a smaller surface area over which the respiratory muscles exerted their force. Thus, pressure being equal to force divided by surface area, could be relatively maintained and not reflect the extent of the loss of muscle force.

Child↗