PubMed HealthSearch

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

An improved FIA biosensor for the determination of aspartame in dietary food products.

A flow injection analysis (FIA) biosensor system was developed for the determination of the artificial sweetener aspartame (L-aspartyl-L-phenylalanine methyl ester). The system consisted of an enzyme column of pronase immobilized on activated arylamine glass beads and a L-amino acid oxidase electrode connected in series. The dipeptide bond of aspartame was cleaved by immobilized pronase to release phenylalanine, which was in turn monitored by the enzyme electrode that used L-amino acid oxidase immobilized on a preactivated nylon membrane in combination with an amperometric electrode (platinum vs silver/silver chloride, 700 mV). The response of the FIA biosensor was linear up to 1 mM aspartame with a lower detection limit of 25 microM and had good reproducibility (rsd 0.3%). The FIA biosensor was stable for at least 30 h of continuous use at Tr. Each assay takes 4 min giving a sample throughput of 15 h-1. When applied to aspartame in dietary food products the results obtained agreed well with those reported by the product manufacturers.

Aspartame

Real-time-analysis of the calcium-dependent interaction between calmodulin and a synthetic oligopeptide of calcineurin by a surface plasmon resonance biosensor.

The calcium-dependent interaction between calmodulin (CaM) and the synthetic oligopeptide of a predicted CaM-binding region of human calcineurin A-2 was analysed with an automated surface plasmon resonance biosensor, BIAcore. The oligopeptide was immobilized to a biosensor chip via the amino-terminal cysteine residue by a thiol-disulphide exchange method. The biosensor chip was regenerated by an EGTA-containing buffer after each analysis. Kinetics experiments showed that CaM bound with a high affinity to the oligopeptide in a Ca(2+)-dependent manner. The estimated rate constants of association (kass) and dissociation (kdiss) were 2.3 x 10(5) M-1.s-1 and 3.9 x 10(-3)s-1, respectively. The ratio of kdiss/kass, 1.7 x 10(-8) M, was in good agreement with the dissociation constant (Kd) of 2.4 x 10(-8) M determined from the equilibrium phase.

Amino Acid Sequence

Affinity ranking of influenza neuraminidase mutants with monoclonal antibodies using an optical biosensor. Comparison with ELISA and slot blot assays.

A recently developed alternative to the more traditional techniques for studying antigen-antibody interactions has been examined. This method involves the use of an optical biosensor employing surface plasmon resonance detection. In this system one of the reactants is immobilized on the sensor surface and other reactants are passed over the sensor surface sequentially at a constant flow rate. Binding phenomena are detected in real time from changes in the angle at which surface plasmon resonance occurs. This is dependent, among other things, on changes in the refractive index (which is directly proportional to the mass) at or near to the sensor surface. Applications of this biosensor technique for comparing the binding of related neuraminidases, purified from escape mutants of influenza virus NWS/G70C/75 (N9), to two antibody Fab fragments, are described. These results were compared with those obtained from ELISA and slot blot assays on the same neuraminidases interacting with the same two monoclonal antibodies. The biosensor method was shown to be highly specific, permitting rapid screening of binding in such antigen-antibody systems.

Antibodies, Monoclonal

Highly stable first-generation biosensor for glucose utilizing latex particles as the enzyme-immobilizing matrix.

The ability of polystyrene latex beads to immobilize glucose oxidase was applied to construct a stable biosensor for glucose. This biosensor measures glucose by detecting the hydrogen peroxide produced by the enzyme. The biosensor performance was studied by amperometry. Glucose concentrations ranging from 1 to 50mM can be measured with this sensor. The sensor is active over a broad range of pH and is very stable, which makes it suitable for a number of possible applications.

Biosensing Techniques

The nature of biosensor technology.

The biosensor exploits the unique specificity of biological recognition events by coupling an enzyme, antibody or other biorecognition species to a transducing device. Interaction of the biocomponent with substrate or antigen is thus converted into a suitable quantitative output. The development of these biosensors is a multidisciplinary effort, exploiting many of the emerging semiconductor and optics technologies and integrating many traditional assay techniques. The impact of these biosensors is likely to be wide-ranging, with applications in medical and industrial environments as well as a variety of other fields.

Biological Assay

In vivo voltammetry with micro-biosensors for analysis of neurotransmitter release and metabolism.

In vivo voltammetry involves the electrochemical detection of central oxidisable substances in situ. In association with this technique micro carbon fibre electrodes (CFE) are able to separate ascorbic acid (Peak 1) from 3,4-dihydroxyphenylacetic acid (DOPAC) plus dopamine (DA) (Peak 2) and 5-hydroxyindoleacetic acid (5-HIAAA) plus serotonin (5-HT) (Peak 3) in vitro. In vivo these biosensors detect the amine metabolites, due to their high extracellular concentration (microM) compared to the amines (nM). In addition homovanillic acid (HVA) (or 3-methoxytyramine (3-MT) in pargyline-pretreated mice) (Peak 4) and somatostatin (Peak 5) were also measured in vivo. However, potassium-stimulated release of DA has been directly monitored in pargyline pretreated mice. In addition, low concentrations (nM) of DA and 5-HT can now be selectively monitored in vitro with new biosensors coated with Nafion which repels negatively charged species including acid metabolites. In vivo, the combination of the Nafion-CFE and normal CFE allowed simultaneous measurements of release and metabolism of 5-HT, respectively. This permitted the observation that changes in 5-HT release are not necessarily reflected by changes in 5-HIAA levels. At present we are developing a Nafion biosensor to monitor basal extracellular DA. Electron microscope studies have shown radical modifications in the surface and structure of carbon fibres following chemical and electrical pretreatments, which may be involved in the development of sensitivity and selectivity displayed by the pretreated CFE towards electroactive compounds. A new approach for selective detection of neuroamines is the analysis of their stimulated fluorescence using LASER. In vitro, the fluorescence of 5-HT is in fact clearly distinguishable from that of 5-HIAA. The feasibility of this methodology in vivo using fiber optic probes will be explored.

Animals

Flow injection analysis and biosensors: applications for biotechnology and environmental control.

Our experience in industrial bioprocess monitoring and environmental control let us develop a concept for biosensor research which distinguishes itself from other, more popular, approaches. Biosensors must improve and/or simplify existing state-of-the-art analysis systems. Only the parallel development of biosensors and their complementary metrology leads to industrially sound solutions. The combination of flow injection analysis with immobilized enzymes in the form of enzyme columns is already used today for the solution of on-line analytical problems in bioprocesses and environmental control.

Biosensing Techniques

Analysis of kinetic data of antibody-antigen interaction from an optical biosensor by exponential curve fitting.

An optical biosensor system employing a resonant mirror (RM), with a stirred cuvette has been used to follow the interaction of a recombinant antibody fragment with its antigen, hen egg lysozyme. The data generated by the biosensor were analysed in order to determine the kinetic constants for the interaction using a linear transform (derivative analysis). For comparison the data were also analysed using an exponential curve fitting routine. It was demonstrated that the exponential curve fitting method produced results which were in agreement with the existing linear transform method. It was also shown that early fitting of the association phase response, using the exponential curve fitting routine between 0 and 70 s after sample addition, yielded sufficient information to provide a prediction of Kon. The potential use of the optical biosensor for the rapid monitoring of protein production and purification is discussed.

Animals

An analysis of antigen-antibody binding kinetics for biosensor applications utilized as a model system: influence of non-specific binding.

The influence of non-specific binding on the specific binding of antigen in solution to antibody immobilized on a biosensor surface is presented for first-, one and a half-, second-, and other order reactions occurring under external diffusion-limited conditions. Both single-step and dual-step binding of antigen to antibody is considered. For a half-order reaction the value of the ratio of non-specific binding to specific binding (alpha) does not affect the rate of specific binding since a single curve represents the binding curve for alpha = 0 to 0.5. An increase in the alpha value leads to a decrease in the rate of binding and in the amount of antigen bound specifically to the antibody on the surface for first-, one and a half-, and second-order reactions. Also, an increase in the reaction order increases the sensitivity of the specific binding to the alpha value. An increase in the antigen concentration in solution increases the amount and the rate of specific binding for first-, one and a half-, and second-order reactions. The introduction of non-specific binding leads to complexities in the specific binding of the antigen for the one and half- and second-order reactions as the antibody concentration on the surface is varied. When non-specific binding is present there is an optimum value of the antibody concentration on the surface that yields the maximum rate and amount of antigen specifically bound for one and a half- and second-order reactions. Though this optimum amount of antibody immobilized on the surface is the same for the one and a half- and second-order reactions, it is different for different alpha values. No such complexities are observed for first-order reactions. The inclusion of non-specific binding in the analysis provides a more realistic picture of the binding of the antigen in solution to the antibody immobilized on the surface. The figures that show the numerically calculated binding rates for different orders when non-specific binding is present, represent the most useful part of the analysis for readers who are interested in constructing biosensors, and should assist in the control and manipulation of these interactions at the surface. These curves can be used to interpret a far from ideal binding of antigen to an immobilized antibody surface or vice versa. More-or-less all of the analysis should also be applicable to analytical systems that would not be classified as biosensors (that is, immuno and receptor assays).

Antibodies

Toxicity order of cholanic acids using an immobilised cell biosensor.

There is considerable published evidence of the use of cells of various species to evaluate the toxicity of numerous compounds, many of pharmaceutical interest. The coupling of cell colonies with a suitable transduction device has led to the development in recent years of toxicity biosensors based on the alteration of a process or a cell metabolic function by the toxic substance under examination. A biosensor based on immobilised yeast cells (Saccharomyces cerevisiae) has been developed recently in this department for the purpose of performing a rapid toxicity test in aqueous environmental matrices. This biosensor has now been used in the toxicity screening of a number of sodium salts of conjugated and free cholanic acids. The "toxicity degree" scale, which was found by placing in decreasing order the values of the slopes of the straight lines obtained by quantifying changes in the behaviour of the respirometric curve, plotted before and after incubation, using known concentrations of cholanic acid sodium salts, was: deoxycholic acid > chenodeoxycholic acid > ursodeoxycholic acid > cholic acid, for free cholanic acids; and glycodeoxycholic acid > glycochenodeoxycholic acid > glycocholic acid, for glycocholanic acids. These values are in good agreement with published toxicity data obtained in vitro. This sensor can thus be considered to provide a valid instrument for the preliminary evaluation of the toxicity of organic compounds or drugs.

Biosensing Techniques

A microbial biosensor for trimethylamine using Pseudomonas aminovorans cells.

A biosensor system based on the difference in the oxygen uptake response of two microbial electrodes was developed to monitor trimethylamine (TMA). The first electrode, constructed using Pseudomonas aminovorans grown on TMA, was sensitive to TMA, trimethylamine N-oxide (TMAO), dimethylamine (DMA) and monomethylamine (MMA). The second electrode responding to TMAO, DMA and MMA was prepared using Ps. aminovorans grown on TMAO. The difference in oxygen uptake was linearly related to the TMA concentration in the range of 5-26 microM. The minimum detectable level was 2.6 microM and the relative standard deviation was determined to be 14% for 16 repeated analyses. When operated and stored at 30 degrees C, the response of the system was stable for only 2 days. However, when the biosensor system was operated at 30 degrees C but stored overnight at 4 degrees C, the system was stable up to 20 days. The biosensor system was applicable for the determination of TMA in fish tissue extracts and the results compared well with those determined by HPLC.

Animals

Monitoring glutamine in mammalian cell cultures using an amperometric biosensor.

An amperometric biosensor has been developed for monitoring glutamine in the pulsed-batch cultivation of murine hybridoma cells. Glutamine oxidase was cross-linked with bovine serum albumin (BSA) via glutaraldehyde activation and deposited on a preactivated nylon membrane. Glutaminase was then immobilized on the protein layer and the resulting membrane was attached to the sensing area of a hydrogen peroxide probe (platinum vs silver/silver chloride polarized at +0.7 V). An orthogonal test was performed to optimize the activity of the membrane for glutamine with respect to the concentrations of glutamate oxidase, BSA, glutaminase and glutaraldehyde. There was an excellent linear relationship between the biosensor's response and glutamine in the range 0.1-3 mM. The determination of glutamine could be performed in 2 min and each membrane was reused for at least 300 consecutive analyses. The data obtained also agreed well with those high-performance liquid chromatography, thus validating the applicability of the biosensor.

Amino Acid Oxidoreductases

Improvement of the selectivity of an FIA amperometric biosensor system for glucose.

A flow injection analysis (FIA) biosensor system has been developed for the determination of glucose from urine, blood plasma and foodstuffs. Glucose oxidase was immobilized onto porous aminopropyl glass beads via glutaraldehyde activation to form an enzyme column. The hydrogen peroxide released from the conversion of glucose to gluconic acid was monitored by a platinum electrode vs. silver/silver chloride poised at +700 mV. As a novel aspect to the improvement of the selectivity of the biosensor system, an anion exchange column was placed upstream to remove uric acid, ascorbic acid or acetaminophen, three major electroactive interfering substances which usually occur in urine and blood plasma. Among several resins tested, the effective adsorption of uric and ascorbic acids could be accomplished using an acetate anion exchanger, and the selectivity coefficient was pH dependent. The binding of acetaminophen to the resin was much less efficient and, in all cases, the selectivity coefficient was independent of the operating temperature up to 37 degrees C. When applied to real samples, the data obtained by the biosensor system compared well with those of the standard hexokinase assay. The immobilized glucose oxidase could be reused for at least 2000 repeated analyses without loss of its original activity.

Acetaminophen

Dynamic concentration challenges for biosensor characterization.

A method and apparatus are described for characterization of the steady state and dynamic response of biosensors. The apparatus produces a steady stream of homogeneously mixed analyte whose concentration can be fixed at discrete values or varied continuously. The device is ideally suited for continuously operated biosensors, but is also effective for biosensors that operate in discrete sampling modes. The system permits simultaneous testing of several sensors and determination of the accuracy, precision and repeatability of sensor response. The characteristics of this testing apparatus were validated with ferrocyanide and glucose as indicators. As an example of use of the apparatus, concentration ramps were created and used to complement conventional step changes for characterizing an implantable glucose sensor. The ramp rate can be adjusted easily by scaling the apparatus to simulate the rate of concentration change anticipated during actual monitoring situations.

Animals

Thin-film conductometric biosensors for glucose and urea determination.

The characteristics of the developed conductometric biosensors for urea and glucose determination are described. Conductometric transducers based on thin-film interdigitated metal (Au, Cr, Cu, Ni) electrodes were studied, and enzymes urease and glucose oxidase were used for the selective membranes formation on the chips having gold electrodes. The influence of ionic strength and buffer capacity of the samples on the biosensors response in kinetic and steady-state modes of measurements was thoroughly tested. It was shown that the kinetic response of the sensors does not depend on the buffer capacity of the analyzed sample. In basic features the performance of the developed biosensors is rather close to that of respective enzyme field effect transistor, though the former are much superior when the technological complexity of the transducer itself is considered and taking into account that conductometric sensors require no reference electrode.

Biosensing Techniques

Enzyme biosensor for urea based on a novel pH bulk optode membrane.

A new, absorbance-based enzymatic biosensor membrane for determination of urea is described. A lipophilic, fully LED- and diode laser-compatible pH sensitive dye was incorporated into a plasticized, carboxylated poly(vinyl chloride) membrane and served as the optical transducer of the sensor. Urease was covalently linked to the surface of the pH bulk optode membrane to form a very thin cover. The resulting biosensor membrane allows rapid determination of urea over the 0.3 to 100 mM range. The reproducibility, stability, and effects of pH and buffer concentration on the response of sensor are reported. The preparation of the pH transducer and the immobilization of the enzyme are simple and may easily be adopted to other biosensor types.

Animals

Enzyme support systems for biosensor applications based on gold-coated nylon meshes.

A novel experimental protocol for enzyme immobilization based on the use of a very permeable support is described and applied to the development of an acetylcholinesterase (AChE) based biosensor. In this system, the enzyme was immobilized onto a gold-coated nylon mesh via a self-assembled monolayer of a bifunctional reagent, cystamine, preadsorbed onto the gold surface. This support has been characterized by optical microscopy and electrochemical measurements of permeability. In the assembled biosensor, the AChE modified mesh was placed over a glassy carbon electrode and the response to 4-aminophenylacetate, used as substrate, was monitored via the enzymatic reaction product, 4-aminophenol, by oxidation at +0.25 V vs. SSCE. This approach to biosensor design has been extended to the determination of organophosphorus and carbamate pesticides by their inhibition of AChE enzymatic activity.

Acetylcholinesterase

Lactate solid-state biosensor with multilayer of electrodeposited polymers for flow-injection clinical analysis.

In the lactate biosensor, electrodeposited poly(o-phenylenediamine) serves as a convenient matrix for the immobilization of lactate oxidase, but does not provide sufficient discrimination from several interfering species present in physiological fluids. Their effect, however, can be eliminated by additional modification of the working Pt electrode with a bilayer of electrodeposited polypyrrole/polyphenol. Despite continued decrease in biosensor sensitivity, the newly developed three-layer solid-state biosensor was successfully applied in flow-injection determination of lactate in both undiluted and diluted human blood serum samples over a 10 day period. For the lactate concentration range 0.2-5.0 mM in several series of measurements the correlation coefficient values for comparison with photometric determination using a DuPont dimension clinical analyzer were between 0.96 and 0.99. The reproducibility measured for 1:10 diluted serum was 0.6%. The detection limit was estimated as 2 microM.

Acetaminophen