PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “nebulization”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

A comparison of sputum induction methods: ultrasonic vs compressed-air nebulizer and hypertonic vs isotonic saline inhalation.

Airway inflammation can be demonstrated by the modem method of sputum induction using ultrasonic nebulizer and hypertonic saline. We studied whether compressed-air nebulizer and isotonic saline which are commonly available and cost less, are as effective in inducing sputum in normal adult subjects as the above mentioned tools. Sixteen subjects underwent weekly sputum induction in the following manner: ultrasonic nebulizer (Medix Sonix 2000, Clement Clarke, UK) using hypertonic saline, ultrasonic nebulizer using isotonic saline, compressed-air nebulizer (BestNeb, Taiwan) using hypertonic saline, and compressed-air nebulizer using isotonic saline. Overall, the use of an ultrasonic nebulizer and hypertonic saline yielded significantly higher total sputum cell counts and a higher percentage of cell viability than compressed-air nebulizers and isotonic saline. With the latter, there was a trend towards squamous cell contaminations. The proportion of various sputum cell types was not significantly different between the groups, and the reproducibility in sputum macrophages and neutrophils was high (Intraclass correlation coefficient, r [95%CI]: 0.65 [0.30-0.91] and 0.58 [0.22-0.89], p < 0.001). Overall changes in median FEV, were small and comparable between all groups. Induction using ultrasonic nebulizers together with hypertonic saline was generally less well tolerated than compressed-air nebulizers and isotonic saline. We conclude that in normal subjects, although both nebulizers and saline types can induce sputum with reproducible cellular profile, ultrasonic nebulizers and hypertonic saline are more effective but less well tolerated.

Administration, Inhalation↗

[Problems in the use, cleaning and maintenance of nebulization equipment in the home situation].

OBJECTIVE: To determine whether jet nebulizers used at home for the treatment of children with asthma are used optimally. DESIGN: Descriptive. SETTING: Outpatient clinic for child pulmonary diseases of the Academic Hospital/Sophia Children's Hospital Rotterdam and outpatient clinic for child diseases of the Baronie Hospital Breda, the Netherlands. METHOD: Thirty-nine children aged 0-13 years and their parents were interviewed at home, and medication cup, saline and aerosol were cultured for bacterial analysis. The pressures of the compressor and nebulizer were measured with a manometer, and the particle size of the aerosol of 10 jet nebulizers was measured by laser technique. RESULTS: The suppliers of the nebulizer did not provide clear instructions on user-related aspects and technical maintenance of the jet nebulizer. Many patients used damaged and poorly functioning, contaminated jet nebulizers. Contamination by potentially pathogenic micro-organisms was present in 50% of the saline, medication cups and aerosols (Klebsiella, Enterobacter, Pseudomonas, Serratia, Escherichia coli). The operating pressure of compressor and nebulizer was below the requirements in more than 50% of the jet nebulizers. In addition, we found that the aerodynamic mass median diameter increased considerably as the nebulizer became older. In 6/10 nebulizers the particle size was below 5 microns. CONCLUSION: A periodical checkup of user-related aspects and technical quality of jet nebulizers is necessary. The quality of the instruction to users about the procedure for cleaning and maintenance of the jet nebulizer should be improved.

Asthma↗

A multimicrospray nebulizer for microwave-induced plasma mass spectrometry

We have developed a nebulizer, called a multimicrospray nebulizer (MMSN), that efficiently introduces analytes for plasma mass spectrometry and plasma emission spectrometry. In this nebulizer, both the sample solution and the nebulizer gas are divided into several streams to produce a multispray. That is, the MMSN is a nebulizer that contains several micronebulization units, each unit including an orifice for passing the nebulizer gas and a capillary for introducing a sample solution. The microspray from each micronebulization unit can be operated at a microliter per minute sample uptake rate to achieve high nebulization efficiency. The multimicrospray nebulizer is capable of introducing more analyte to the plasma compared with a single-orifice micronebulizer, which has a very low sample uptake rate. In this work, an MMSN with three orifices was found to be suitable for microwave-induced plasma mass spectrometry (MIP-MS). The sample uptake rate can be varied within a range of 5-250 microL/min. Therefore, the nebulizer is unique in its ability to deal with various sample volumes and provide high nebulization efficiency. The sensitivity for all elements obtained with the MMSN was higher than that obtained with a conventional concentric nebulizer (CCN), which is difficult to achieve with other types of microintroduction nebulizers. For most elements, the MIP-MS sensitivity was improved about 2-fold at a sample uptake rate of 150 microL/min, a much lower rate than that for the CCN (usually 0.5-1.5 mL/min). The sensitivity for arsenic was improved by a factor of 5. The relative standard deviation was found to be less than 2.0%.

Journal Article↗

Dose-dependent evaluation of the effects of nebulized furosemide on pulmonary function in ventilated preterm infants.

OBJECTIVE: We have previously shown that a single dose of nebulized furosemide improves tidal volume and pulmonary compliance for up to a 2-hour study period. This study is undertaken in order to find out (a) whether increasing the dose of nebulized furosemide from 1 to 2 mg/kg of body weight will further improve the pulmonary mechanics in premature infants with evolving chronic lung disease and (b) whether the effects of a single dose of nebulized furosemide last beyond 2 hours. STUDY DESIGN: The effect of nebulized furosemide on pulmonary mechanics was studied at a mean postnatal age of 24 days (range 14 to 50 days) in 13 premature infants, 24 to 28 weeks' gestational age, who had been dependent on mechanical ventilation since birth. Furosemide was administered by nebulization at doses of 1 and 2 mg/kg of body weight, in random order, on two separate days 24 hours apart. Pulmonary function studies were performed before and 2, 4, and 6 hours after the nebulization. Urine was collected for 6 hours immediately before and for 6 hours after the nebulization. RESULTS: Furosemide by nebulization at 1 and 2 mg/kg of body weight resulted in significant improvement in tidal volume and compliance. There was no difference in the magnitude of response between the two doses. Neither 1 nor 2 mg/kg of body weight of nebulized furosemide had any effect on airway resistance. The improvement was maximum for up to 4 hours and lasted for up to 6 hours after the nebulization and was not associated with diuresis or increased excretion of urinary electrolytes. CONCLUSION: A single dose of nebulized furosemide improves pulmonary function for up to 6 hours after its administration. Increasing the dose from 1 to 2 mg/kg of body weight results in no further improvement in the pulmonary function. The pulmonary effects of nebulized furosemide are independent of its diuretic action.

Aerosols↗

Effect of nebulized colistin sulphate and colistin sulphomethate on lung function in patients with cystic fibrosis: a pilot study.

BACKGROUND: Pulmonary administration of colistin is one of the antimicrobial treatments used in Cystic Fibrosis (CF) patients chronically infected with Pseudomonas aeruginosa. Dry powder inhalation of colistin may be an attractive alternative to nebulization of colistin. However, nebulized colistin can cause bronchoconstriction in CF patients. Therefore, in the progress of developing a dry powder formula, the choice of the inhaler and its contents should be guided by optimal efficacy and the least possible side effects. To investigate the side effects, a study was initiated to compare the tolerability of colistin sulphate to colistin sulphomethate per nebulization in CF-patients. METHODS: Nine CF-patients chronically infected with P. aeruginosa participated in a double blind, randomized cross over study. On two visits to the outpatient clinic, patients were submitted to either nebulized colistin sulphate or colistin sulphomethate solution. Lung function tests were performed immediately before and 15 and 30 min after nebulization. RESULTS: Nebulization of colistin sulphate caused a significant larger mean decrease in lung function compared to nebulized colistin sulphomethate. A significant decrease in mean changes (SD) in FEV1 at 30 min and FVC at 15 and 30 min after nebulization compared to baseline of -7.3% (8.6%), -5.7% (7.3%) and -8.4% (7.5%) respectively was seen after colistin sulphate nebulization compared to colistin sulphomethate (P < 0.05). Seven patients were not able to complete the nebulization of colistin sulphate because of throat irritation and severe cough. CONCLUSION: Based on these results it was concluded that inhalation with nebulized colistin sulphate is not suitable for treatment of CF patients chronically infected with P. aeruginosa. Colistin sulphomethate is the drug of choice for pulmonary administration of colistin.

Administration, Inhalation↗

Delivery of glucocorticoids by jet nebulization: aerosol characteristics and output.

BACKGROUND: Since inflammation has been identified as a critical factor in the pathogenesis of asthma, use of inhaled glucocorticoids has increased. Because young children are often unable to coordinate properly the use of metered-dose inhalers and no glucocorticoids preparations for nebulization have been approved in the United States, parenteral and intranasal glucocorticoids preparations are occasionally administered by nebulization. METHODS: We examined whether a parenteral preparation (triamcinolone acetonide [TAA]; Kenalog) could be delivered by nebulization. TAA, 1000 micrograms (0.1 ml), was placed in the nebulizer bowl (MB5 [MeFar, Brescia, Italy] or Pari-Jet [Dura Pharmaceuticals, San Diego, Calif.]), then diluted with 2.9 ml normal saline solution for a total volume fill of 3 ml. Using a laser particle analyzer, high-performance liquid chromatography, and cascade impactor, we examined the percentage of aerosol volume produced with particles in the respirable range of 1 to 5 microns in diameter, actual TAA output (in micrograms) and concentration of TAA contained in the particles within the respirable range. RESULTS: Laser particle analysis indicated that 34% +/- 3% (mean +/- SEM) (MB5) and 47 +/- 3% (Pari-Jet) of the total aerosol volume produced were within the respirable range of 1 to 5 microns in diameter, and this remained consistent throughout nebulization. The nebulizer was stopped serially for determination of TAA output with high-performance liquid chromatography. TAA output (1000 micrograms less the amount in micrograms remaining after nebulization) was essentially complete after 2 minutes with the Pari-Jet and within 4 minutes with the MB5 and totaled 352 +/- 19 micrograms and 367 +/- 9 micrograms, respectively. Finally, cascade impactor studies confirmed that 33.4% of the TAA aerosol generated by the MB5 nebulizer was contained in particles in the respirable range. CONCLUSION: Approximately 35% (Pari-Jet) and 37% (MB5) of the initial 1000 micrograms of TAA was delivered with the two nebulizers tested. The particles generated within the respirable range were limited to 34% (MB5) and 47% (Pari-Jet) of the amount delivered. TAA was equally distributed in the particles generated. The theoretic amount delivered in the respirable range was approximately 12.5% for the MB5 nebulizer on the basis of the cascade impactor and 16.5% for the Pari-Jet (assuming TAA distribution equivalence) of the TAA placed in each of the nebulizers. Additional clinical studies are needed to define efficacy and safety in view of the excipients used in preparing the parenteral preparation.

Aerosols↗

Audit of a complete home nebulizer service provided by a respiratory nurse specialist.

A retrospective audit was performed of a home nebulizer service managed entirely by a Respiratory Nurse Specialist (RNS). We examined (i) the role and workload of the RNS, (ii) the outcome of referrals to the service and (iii) the subsequent compliance with treatment of patients prescribed home nebulized bronchodilators. The case notes and RNS records of all patients referred for consideration of home nebulized bronchodilators over a 9-month period were reviewed. The nebulizer service encompassed patient assessment, trials of nebulized therapy, nebulizer tissue and patient registration and an exchange and servicing system. The non clerical aspects of the service took 9 h per week, 24% of total RNS time. A further 15 h weekly of clerical time was also required. Of 76 referrals, 57 (75%) patients had chronic airflow obstruction (CAO). In CAO patients, 41 had a trial of nebulized therapy and in 27 (66%) such therapy was considered beneficial. In the other 16 CAO patients the RNS deemed a trial inappropriate or impractical and 12 such patients were prescribed nebulized therapy. Overall, therefore 39/57 (68%) of CAO referrals were prescribed home nebulized therapy. At 3-6 months, seven (18%) patients were using their nebulizer infrequently or not at all, 25 (64%) one to four times daily, and seven (18%) four times daily. We conclude that a RNS can manage a complete nebulizer service, but at a considerable cost in professional time. Clerical assistance is essential if appropriate use is to be made of the skills of an RNS.(ABSTRACT TRUNCATED AT 250 WORDS)

Clinical Competence↗

A comparison of bronchodilator responses to albuterol delivered by ultrasonic versus jet nebulization in moderate to severe asthma.

BACKGROUND: Nebulization of beta-agonists is preferred as a mode of treatment in moderate to severe asthma. Few studies, however, have compared its use in this population using an ultrasonic versus a jet nebulizer. OBJECTIVE: The purpose of the study was to compare bronchodilator responses to albuterol between an ultrasonic and a jet nebulizer in moderate to severe asthma. METHODS: Fifteen stable, moderately to severely asthmatic patients were randomized to receive the ultrasonic or jet nebulizer for 2 weeks. They were then crossed over for an additional 2 weeks. Albuterol was the agent used. The bronchodilator response was measured at baseline, and up to four hours after treatment with each nebulizer. Daily peak flows were then done for 2 weeks. RESULTS: The maximal percentage of increase in FEV1 at 30 minutes using the ultrasonic nebulizer was 39.9 +/- 8% (P < 0.001) versus 25.1 +/- 7.6% (P = .005) using the jet nebulizer. There were no other differences between the ultrasonic and the jet nebulizer in FEV1 or FVC during the 4-hour spirometry. During the home trial, the difference in evening PEFR between the jet nebulizer (69.05 +/- 14.9 L/min) and the ultrasonic nebulizer (90.11 +/- 18.7 L/min) was significant (P = .04). CONCLUSIONS: In summary, the ultrasonic and the jet nebulizer produced comparable bronchodilator responses to albuterol in stable moderately to severely asthmatic patients.

Adolescent↗

In vitro evaluation of nebulization properties, antimicrobial activity, and regional airway surface liquid concentration of liposomal polymyxin B sulfate.

PURPOSE: To manipulate the activity of polymyxin B sulfate (PXB sulfate) by encapsulation in liposomes derived from appropriately selected surfactants that exhibit optimum entrapment and aerosol delivery of encapsulated PXB sulfate. METHODS: A combination of phospholipid (DMPG) and nonionic surfactants (Span 20 + Tween 80) was selected to encapsulate PXB sulfate. The nebulization properties were evaluated by nebulizing the liposomal dispersions with Pari LC Star nebulizers. The in vitro antibacterial activities of the original and nebulized liposomal formulations were evaluated against Pseudomonas aeruginosa (ATCC 27853) strains by broth microdilution. and their minimum inhibitory concentrations (MICs) were compared with those of free PXB sulfate and colistin methanesulfonate. Measurements of the aerosol properties during nebulization were used as input for a mathematical model of airway surface liquid in the lung of an average adult, to estimate the airway surface liquid concentration of the deposited liposomal PXB sulfate. RESULTS: The selected combination of surfactants showed maximum nebulization efficiency without compromising liposomal integrity during nebulization. PXB sulfate was added at a concentration of 10 mg/ml, and a molar ratio of PXB sulfate to dimyristoyl phosphatidylglycerol (DMPG) (sodium salt) of 1:5 was required to achieve 100% entrapment of PXB sulfate and no leakage on nebulization. Another formulation comprising half the concentrations of the optimized non-ionic surfactants and DMPG was prepared to achieve a balance between the toxicity and efficacy after nebulization of encapsulated PXB sulfate. The in vitro antibacterial activities against Pseudomonas aeruginosa indicated that the activity of PXB sulfate could be manipulated by appropriate concentrations of the selected surfactants to achieve activity equivalent to that of colistin methanesulfonate, which is known to be less toxic than unencapsulated PXB sulfate. The estimated airway surface liquid concentrations of the deposited liposomal PXB sulfate reveal that the MIC of the nebulized liposomal PXB sulfate can be achieved over most of the tracheobronchial region, using a jet nebulizer with a volume fill of 2.5 ml or more. CONCLUSION: It was established from this study that the encapsulation of PXB sulfate in liposomes reduces its activity against P. aeruginosa strains. Concentrations of PXB sulfate deposited in the tracheobroncial region, predicted using a mathematical model, were above the measured MICs except in the case of very high mucus production rate and low mucus velocities.

Anti-Bacterial Agents↗

Continuous versus intermittent nebulization of salbutamol in acute severe asthma: a randomized, controlled trial.

STUDY OBJECTIVE: This study was conducted to compare the clinical and spirometric effects of continuous and intermittent nebulization of salbutamol in acute severe asthma. METHODS: Forty-two consecutive patients presenting to the emergency department for acute severe asthma (peak expiratory flow [PEF] mean+/-SD, 24%+/-12% predicted) were prospectively randomly assigned to receive 27.5 mg of salbutamol by either continuous or intermittent nebulization over a 6-hour period. The continuous nebulization group received 15 mg of salbutamol during the first hour and 12.5 mg over the next 5 hours. The intermittent nebulization group received 5 mg of salbutamol every 20 minutes during the first hour and 2.5 mg hourly over the next 5 hours. All participants received oxygen and intravenous hydrocortisone. Clinical and spirometric assessment was performed at baseline, 40 minutes, 60 minutes, and at 3 and 6 hours after the start of the nebulization. Secondary endpoints were the respective rates of hospitalization and treatment failure. RESULTS: A significant clinical and spirometric improvement was observed in both groups over baseline as soon as the 40th minute and was sustained thereafter (absolute PEF increase at the sixth hour 30%+/-18% and 32%+/-22% in the continuous and intermittent nebulization groups, respectively; P <.01 over baseline). PEF and the clinical score evolved similarly in both groups. There was no difference between the groups regarding the failure rate of the initial bronchodilator treatment to terminate the asthma attack (3 [14%] in the continuous nebulization group and 2 [9.5%] in the intermittent nebulization group, absolute difference 4.5% [95% confidence interval -14% to 23%]). Eight (38%) patients and 9 (43%) patients from the continuous and intermittent nebulization groups, respectively, required hospitalization according to predefined criteria (absolute difference 4.8% [95% confidence interval -24% to 34%]). CONCLUSION: We did not observe an appreciable difference between continuous and intermittent nebulization of salbutamol in acute severe asthma. The decision to use one of these nebulization methods should be based on logistical considerations.

Acute Disease↗

Evaluation of four breath-enhanced nebulizers for home use.

The objective of this study was to evaluate relative efficiency in vitro of four reusable breath-enhanced nebulizers (Pari LC Star, Medic-Aid Ventstream, Devilbiss PermaNeb, Salter Ultramist), and to integrate the in vitro performance data of the nebulizers with the respiratory patterns of four cystic fibrosis (CF) patients to compare efficiency in vivo of each device for each individual patient. Six nebulizers of each type were used to nebulize a solution of 2.5 mg (0.5 mL) albuterol with 3.5 mL of 0.9% saline. Total albuterol output and the rate of albuterol output of each device were measured until end-nebulization and for 4 min, respectively, using entrained flows from 0 to 20 L/min through the inspiratory valve of the device. Particle size distributions and the respirable fraction (RF) were evaluated by laser diffraction technique. Regression analysis of the change in rate of output and change in RF values with inspiratory flows was done to characterize each nebulizer's performance over the complete range of interest. Actual breath tracings of four CF patients were integrated with the equations specific to the in vitro performance of each nebulizer and in vivo nebulizer efficiency was calculated. The change in efficiency in vitro from 0 to 20 L/min flow, respectively, was highest for the Star (44-57%) and lowest for the Ultramist (13-15%). The mean predicted efficiency in vivo for the Star was threefold that of the Ultramist. Although all four nebulizers are breath-enhanced in design, clearly there are measurable differences in the performance and efficiency of each type. The Pari LC Star nebulizer has proven to be the nebulizer of choice among the devices tested.

Aerosols↗

Lung deposition in cystic fibrosis patients using an ultrasonic or a jet nebulizer.

This study was conducted to compare pulmonary deposition following inhalation with an ultrasonic and a jet nebulizer in CF patients under conditions relevant to practice. The marker substance used to estimate the relative lung bioavailability was sodium cromoglycate (SCG), which is poorly absorbed from the gastrointestinal tract, but is completely absorbed from the lungs. Ten CF patients (aged 9-21 years) used an ultrasonic nebulizer (Multisonic compact 2.4 MHz) and a jet nebulizer (Parimaster, LC Plus Turbo) in a crossover design to inhale a solution containing 20 mg of SCG and a beta(2)-agonist. Urine was collected in five fractions until 12 h p. a., and the excreted SCG was determined by means of HPLC. Prior to each inhalation, the patients' pulmonary function was measured employing a Pneumoscope. Using the ultrasonic nebulizer, the amount of SCG excreted in urine was significantly greater than that after inhalation with the jet nebulizer (1.43 +/- 0.47 mg vs. 1.04 +/- 0.47 mg; p = 0.002), despite the larger residual volume in the ultrasonic nebulizer. The absorption half-life for SCG following ultrasonic nebulization was significantly shorter when compared with jet nebulization (84 +/- 14 min vs. 101 +/- 19 min; p = 0.005), being suggestive of a more peripheral deposition. Furthermore, an inverse relationship was found between absorption half-life and FEV(1) (% pred.) (r = -0.655, p = 0.04) or MMEF(75/25) (% pred.) (r = -0.844, p = 0.031), but only with the ultrasonic nebulizer. In conclusion, the ultrasonic nebulizer tested when used for inhalation in CF patients was found to be at least equivalent to the jet nebulizer.

Adolescent↗

In vitro evaluation of bronchodilator drug delivery by jet nebulization during pediatric mechanical ventilation.

OBJECTIVE: To determine the influence of jet nebulizer brands and nebulization mode on albuterol delivery in a mechanically ventilated pediatric lung model. DESIGN: In vitro, laboratory study. SETTING: Research laboratory of a university hospital. INTERVENTIONS: Using albuterol as a marker, six jet nebulizers (Microneb NA420, Sidestream, Acorn II, Cirrus, Upmist, Micro Mist) were tested in four nebulization modes in a bench model mimicking the ventilatory pattern of a 10-kg infant (Galileo ventilator, Hamilton Medical). The amounts of albuterol deposited on the inspiratory filters at the end of the endotracheal tube were determined, as well as the pressure, flow profiles, and particle size distribution of the jet nebulizers. MEASUREMENTS AND MAIN RESULTS: Pooling the data of the six jet nebulizer brands (n = 30) indicated that intermittent nebulization during the expiratory phase was more efficient (6.5 +/- 2.5% of the initial dose, p < .001) than intermittent nebulization during the inspiratory phase (1.9 +/- 1.2%) and continuous nebulization with air from the ventilator (4.0 +/- 1.5%) or from an external source (4.2 +/- 1.4%). The particle size distribution at 6 L x min(-1) was between 2.81 and 3.30 microm. CONCLUSIONS: In our in vitro pediatric lung model, the quantity of inhaled drug was low. Jet nebulizer brands and nebulization modes significantly affected drug delivery, and in vitro models designed for adults cannot be extrapolated to infants.

Aerosols↗

Liquid nebulization: emerging technologies conference summary.

Most physicians and respiratory therapists are knowledgeable of the use of aerosolized drugs, but many are less familiar with the performance characteristics of the nebulizer. In fact, the general opinion is that the performance of the nebulizer is relatively unimportant. However, there is accumulating evidence that the nebulizer itself does make a difference. The decision to replace a good performing nebulizer with a poor performing nebulizer may decrease the delivered dose in half or more. Although this is less important for routine bronchodilator therapy, it may make a big difference with newer aerosolized drugs. Increasingly, the Food and Drug Administration is approving drugs to be used with a specific nebulizer brand and new nebulizer designs are becoming available for use with these drugs. There are several reasons why I think this conference was important. First, new aerosol drug formulations are becoming available and these will require better performing nebulizers. Second, we as clinicians need to be knowledgeable of the newer generations of nebulizers so that we can make informed purchase decisions. Third, and perhaps most important, we must gain an increased appreciation for aerosol therapy as a science. The proceedings of this conference do much to synthesize the current state-of-the art related to new nebulizer systems. This provides, in a complete and cogent manner, the scientific basis for which clinicians can improve their knowledge of the new generation of nebulizers.

Administration, Inhalation↗

Nebulizer use and maintenance by cystic fibrosis patients: a survey study.

INTRODUCTION: Patients with cystic fibrosis (CF) suffer from chronic infection of the airways, and typical CF therapies include aerosolized medications. There is recent evidence that home nebulizers become contaminated by bacteria, causing concern that nebulizers may be a source of bacterial infection of the lower airways. A recent consensus document on infection-control issues for the CF population included recommendations on cleaning and disinfecting nebulizers. METHODS: We surveyed 39 patients and their parents, as well as 54 respiratory therapists, regarding their routine nebulizer use and maintenance practices. RESULTS: All the patients used at least one nebulized medication, and they used a variety of nebulizers, obtained from a wide variety of sources. Thirty percent of the patients used nebulizers well beyond the manufacturer's recommended replacement date. Ninety percent of the patients rinsed their nebulizers following use, but only 15% performed any routine disinfection. The respiratory therapists' nebulizer cleaning methods were widely disparate, with only 70% performing some method of rinsing. The respiratory therapists' self-report of cleaning methods and their instructions to patients regarding frequency of cleaning were so diverse that no standard is evident. CONCLUSION: This study demonstrates that CF patients and their respiratory therapists should immediately address and improve their nebulizer cleaning methods and replacement practices. There should be more focus on teaching patients to regularly clean and replace nebulizers.

Adult↗

Osmolality changes in nebulizer solutions.

Paradoxical effects (bronchoconstriction instead of bronchodilatation) have been reported after inhalation of beta2-mimetics in asthmatic children, and it has been suggested that this was due to osmolality and pH changes of the nebulizer solution. We tested commercially available nebulizer solutions and found osmolality changes after 5, 10 and 15 min of nebulization. Osmolality was measured in the nebulizer chamber and the airsteam of two types of jet nebulizers. When normal saline was nebulized chamber, from 282 +/- 7 mmol.kg-1 to 432 +/- 18 mmol.kg-1 resulted. Salbutamol ready made solution, and terbutaline respules were isotonic, whereas fenoterol, disodium cromogylcate (DSCG), beclomethasone dipropionate (BDP) and salbutamol (respirator solution 0.5%) were hypotonic (60-100 mmol.kg-1). When a mixture of sodium chloride (NaCl) and the drug solution (salbutamol, terbutaline, fenoterol) was nebulized for 10-15 min, the osmolality in the nebulizer cup increased to 420-500 mmol.kg-1. However, mixtures of the same beta 2-agonists with DSCG or with BDP remained hypo-osmolar. The same osmolality changes were present in the airstream. This study shows that after 10-15 min of nebulization osmotic changes occur in the nebulizer cup and airstream and that these changes differ according to the drug mixtures and the amount of the solution in the nebulizer chamber.

Adrenergic beta-Agonists↗

[Isoproterenol continuous nebulization for childhood status asthmaticus. I. Efficacy and side effects of high-dose method].

We investigated the efficacy and the side effects of "high-dose isoproterenol continuous nebulization" for childhood status asthmaticus. Subjects were 34 children who were hospitalized and underwent the nebulization therapy. The 50 ml solution of 0.5% dl-isoproterenol was diluted in 500 ml of normal saline and nebulized through an ultrasound nebulizer. The period of continuous nebulization was 25.5 +/- 16.0 hours. The Wood's clinical score clearly decreased in 32 cases, the average score changing from 7.7 +/- 0.8 to 2.9 +/- 1.3. Heart rate was elevated significantly during the first 3 hours (156 +/- 25/min at the start of the nebulization, 180 +/- 20/min at 1 hour, 171 +/- 23 at 3 hours), and then it decreased gradually to 122 +/- 25/min at the cessation of the nebulization. Serum GOT, LDH, CPK, and potassium were elevated after the nebulization compared with the values before the treatment, though the changes were not statistically significant. CPK-MB fraction after the nebulization was higher than normal range in 12 of 13 subjects. Of 34 subjects, 11 (32%) complained nausea or vomited, 2 showed arrhythmia on ECG (ventricular premature conduction), 1 developed myocardiac infarction, and 1 developed possible heart failure, some of which might be attributable to the pharmacological side effects of isoproterenol nebulization. We conclude that "high-dose isoproterenol continuous nebulization" is an effective method for childhood status asthmaticus, but there is some risk of serious side effects. This method was originally developed as a method indicated for the case of respiratory failure or threatened respiratory failure following status asthmaticus, and we should not extend the indication of this method thoughness.

Administration, Inhalation↗

Nebulizer use in inner-city children with asthma: morbidity, medication use, and asthma management practices.

OBJECTIVE: To assess the frequency of nebulizer use, describe morbidity and patterns of medication administration, and examine the potential relationships between inhaled anti-inflammatory medication administration, asthma morbidity, and asthma management practices in children with asthma using a nebulizer compared with children with asthma not using a nebulizer. RESEARCH DESIGN: A cross-sectional, descriptive survey of previous events. SETTING: Elementary schools and participants' homes in Baltimore, Md, and Washington, DC. PARTICIPANTS: Six hundred eighty-six families of children aged 5 to 12 years with a diagnosis of at least mild, persistent asthma. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Asthma morbidity, health care utilization, pattern of asthma medication administration, nebulizer use, and asthma management data were collected by telephone survey administered to caregivers. Nebulizer use was defined as use at least 1 or more days per month during the last 6 months. Of 686 children identified, 231 (33%) reported current nebulizer use. Nebulizer users had significantly increased lifetime hospital admissions, hospitalizations, and emergency department visits in the last 6 months compared with nonnebulizer users. Inhaled corticosteroid administration was low for both groups (nonnebulizer users, 8%; nebulizer users, 15%). In the nebulizer users group, administration of inhaled anti-inflammatory medications was associated with increased asthma morbidity (increased hospitalizations, days and nights with symptoms, and oral steroid use). CONCLUSIONS: Nebulizer use by inner-city children with asthma is higher than anticipated but is not associated with reduced asthma morbidity. This group of high-risk children was undertreated with inhaled corticosteroids for long-term control of asthma despite reports of adequate monitoring by a primary care physician.

Administration, Inhalation↗