Diagnosis of sleep apnea.

Obstructive sleep apnea syndrome (OSAS) is characterized by repeated oropharyngeal occlusions occurring during sleep. The prevalence of moderate OSAS (with an apnea-hypopnea index = or >15/h) is 9% and 4% in male and female, respectively. It is associated with an abnormally high frequency of cardiovascular disease (hypertension, stroke, coronary heart disease) and excessive daytime sleepiness responsible for an increased frequency of work and road accidents. Because the treatment of OSAS provides many benefits to patients and society, it is very important to obtain an early diagnosis. The diagnosis of OSAS is based on the combination of characteristic clinical features plus compatible findings on instrumental tests in which multiple physiologic signals are monitored simultaneously during a night of sleep. A full night polysomnography, conducted by a technologist in a sleep laboratory, is the gold standard for the diagnosis of suspected OSAS, but the capacity for performing polysomnography is limited. On the basis of the high incidence and prevalence of OSAS, of the limited number of sleep laboratories, long waiting times and high costs recommendations have been formulated for the use of unattended portable systems in the assessment of OSAS. The main clinical aspects of of OSAS, the diagnostic approach with full night polysomnography and unattended portable systems, the differential diagnosis and some examples of cardiorespiratory portable monitoring are presented in this paper.

Diagnosis, Differential↗

Epidemiology by computer.

Collecting epidemiological data from a large community sample has, in the past, been a costly and time-consuming exercise. This paper outlines a methodology for undertaking such research by using a set of standard psychiatric questionnaires, including a computerised version of the Diagnostic Interview Schedule Screening Interview on a portable laptop computer. The study of 1009 country South Australian subjects found that this technique provided prevalence estimates similar to those obtained from the more established Diagnostic Interview Schedule, with the added benefit that all interviews were successfully carried out by lay interviewers under minimal supervision, in the subject's home.

Computers↗

Measuring agreement between diagnostic devices.

There is growing interest in using portable monitoring for investigating patients with suspected sleep apnea. Research studies typically report portable monitoring results in comparison with the results of sleep laboratory-based polysomnography. A systematic review of this research has recently been completed by a joint working group of the American College of Chest Physicians, the American Thoracic Society, and the American Academy of Sleep Medicine. The methods for comparing the results of portable monitors and polysomnography include product-moment correlation, intraclass correlation, mean differences/limits of agreement, sensitivity, specificity, and likelihood ratios. Each approach has advantages and limitations, which are highlighted in this review.

Humans↗

Diagnostic and interventional ultrasound for breast disease.

The availability of reliable, portable computer-enhanced ultrasonography with high-frequency transducers has improved breast ultrasonography such that its role has increased dramatically. Diagnostic characteristics of breast lesions may be used to categorize these lesions according to their relative risk for malignancy. Furthermore, breast ultrasonography may be used to guide needle aspiration and biopsy of lesions so indicated by diagnostic evaluation. Results of ultrasound-guided aspiration and core biopsy accurately diagnose specific histopathology thereby avoiding unnecessary open biopsy for benign lesions and facilitating therapeutic planning for malignant lesions.

Algorithms↗

Portable computed tomography performed on the intensive care unit.

OBJECTIVE: We report on the use of portable computed tomography (CT) in an ICU setting. The additional diagnostic gain and therapeutic consequences were assessed. PATIENTS: Ten ICU patients underwent 14 portable chest CT examinations. In 64% maximum intensive care was required, according to TISS28 (>40), and 42% were at a risk of mortality higher than 25% (MODS) on the day of portable CT examination. In three portable CT examinations the patients were considered not transportable and were examined directly in the patient room. All other examinations were performed in a special interventional suite directly on the ICU. RESULTS: Of 14 examinations 8 (57%) resulted in a change in patient management within 48 h. All patients profited from portable CT and no hazards occurred related to CT. CONCLUSIONS: To perform portable CT in the interventional suite on the ICU allows immediate minimally invasive therapeutic interventions and provides full ICU monitoring.

Adult↗

Sonography in the infant with acute abdominal symptoms.

The sonogram is a reliable diagnostic tool in the evaluation of acute abdominal disorders in infants and children. Portability, noninvasiveness, and ease of examination make sonography an invaluable diagnostic method. This article considers the principle acute disorders of infancy and childhood that are minimal to sonographic diagnosis. Included are pyloric stenosis, appendicitis, necrotizing enterocolitis, intussusception, as well as unexplained abdominal distention and acutely presenting masses. Although some of these entities have nonspecific sonographic appearances, consideration of age, symptoms, and laboratory results usually permits a specific diagnosis.

Abdomen↗

Capillary whole blood testing by a new portable monitor. Comparison with standard determination of the international normalized ratio.

We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.

Acenocoumarol↗

Artificial orbit system for experimental surgery with enucleated globes.

A portable system for holding, accurately positioning, and restoring the physiologic integrity of enucleated globes during experimental anterior segment procedures and pars plana vitrectomy is described. A 0 to 500-mm Hg vacuum fixation ring and positioning apparatus mechanically locks globes into known spatial position while they are supported in a 2 to 6-mm Hg pressurized, pliable socket designed to match the size and pressure of a natural orbit. A gravity infusion system and an implantable piezoelectric pressure sensor in conjunction with a syringe and stopcock assembly allow for controlled inflation of globes to intraocular pressure (IOP) levels from 0 to 70 mm Hg, and to over 300 mm Hg. The fixation vacuum level, and intraocular and extraocular pressures are simultaneously monitored on 3-digit LED displays, and permanent records of each can be generated by routing data to storage devices. The anterior segment remains accessible at all times for surgical procedures and diagnostic measurements. The entire system is portable, allowing globes to be transported to multiple experimental stations, while all pressure settings and the position of the globe are maintained. To demonstrate applications of the artificial orbit system, we describe experiments using it to calibrate applanation tonometers, and to study the relationship between IOP and corneal curvature as well as the effect of trephination procedures and limbal vacuum fixation on IOP.

Animals↗

How accurate is measuring postvoid residual volume by portable abdominal ultrasound equipment in peritoneal dialysis patient?

INTRODUCTION: Despite the wide spread use of modern portable ultrasound equipment to measure the postvoid residual urine, its accuracy and reliability has been questioned. We investigated the accuracy of postvoid residual urine measurement by portable abdominal ultrasound equipment in end-stage renal disease patients who are under either hemodialysis or peritoneal dialysis. MATERIALS AND METHODS: A total of 21 male (range: 25-44 years, mean age: 32 years) end-stage renal disease patients were studied. Ten were under peritoneal dialysis and 11 under hemodialysis. After uroflowmetric study, all patients were evaluated with portable abdominal ultrasound equipment (BladderScan BVI 3000, Diagnostic Ultrasound Corporation, WA) by both a technician and a physician and they were subsequently catheterized with a 10F catheter to measure the residual urine volume in the urinary bladder. Postvoid residual urine volume results by portable abdominal ultrasound equipment and urethral catheterization were analyzed. RESULTS: We found portable abdominal ultrasound to be very accurate to measure the volume of postvoid residual urine in hemodialysis patients(r=0.921, P<0.05 by physician and r=0.904, P<0.05 by technician). However, accuracy was the worst in peritoneal dialysis patients (r=0.055, P=0.88 by physician and r=0.336, P=0.343 by technician). The technician or physician use of the equipment did not change the accuracy profile of the equipment in both hemodialysis and peritoneal dialysis patients. CONCLUSIONS: Portable abdominal ultrasound equipment may be an unreliable method to measure postvoid residual urine volume in peritoneal dialysis patients.

Abdomen↗

[Bone mineral density in postmenopausal women with proximal femoral fractures--comparative study between quantitative ultrasonometry and gold standard DXA].

INTRODUCTION: Osteoporosis associated proximal femoral fracture is a major public health problem. Diagnostic assessment includes patients history, laboratory testings and bone mineral density measurements. Hereby, dual X-ray absorptiometry (DXA) is regarded as the "Goldstandard". Quantitative ultrasonometry (QUS) of bone is a safe, simple, free of radiation, portable, cost-effective and therefore powerful diagnostic tool. QUS should be taken in account for primary assessment in patients with supposed osteoporosis in clinical practice. AIM OF THE STUDY: We performed this cross sectional pilot study to evaluate the ability of two different QUS-devices (os calcis) in comparison to DXA (lumbar spine and femoral neck) to discriminate postmenopausal women with proximal femoral fractures from healthy, age- and BMI-matched controls. PATIENTS AND METHODS: All together, 44 postmenopausal women were included. Of these, 22 suffered a proximal femoral fracture and were compared with 22 healthy, age- and BMI-matched controls. Bone assessments were performed by DXA (femoral neck and lumbar spine) and QUS of the heel using Achilles and Insight. RESULTS: T- and Z-Score of DXA (femoral neck) were significantly lower in women with hip fracture compared to controls (p < 0.008 and p < 0.01). QUS-Insight also revealed significantly lower values of T- and Z-Score in women with hip fracture compared to controls (p < 0.01 and p < 0.005). QUS-Achilles measurement results also comprised significant differences between the groups (T-Score und Z-Score: p < 0.02). In accordance to the T-Score (femoral neck), all three devices (DXA femoral neck, Achilles and Insight) showed an equal significant correlation (p < 0.001). The correlation in between both QUS-devices was higher (0.956; p < 0.0001) than in between DXA-results (femoral neck vs. lumbar spine, 0.577; p < 0.01). The Z-Score also showed a significant correlation. DXA (lumbar spine) didn't show any significant differences in T- and Z-Score. CONCLUSION: In comparison to the gold standard DXA (femoral neck), both QUS-devices showed an equal ability to significantly discriminate postmenopausal women with proximal femoral fractures from healthy, age- and BMI-matched controls. If our results are confirmed by more cross-sectional and longitudinal studies, QUS could be a helpful and valuable technique in clinical practice. Finally, all patients with osteoporosis-related fractures should be thoroughly investigated during their hospitalisation and effective treatment must be instituted.

Absorptiometry, Photon↗

Systematic instrumental errors between oxygen saturation analysers in fetal blood during deep hypoxemia.

BACKGROUND: During a study of artificially produced deep hypoxemia in fetal cord blood, systematic errors of three different oxygen saturation analysers were evaluated against a reference CO oximeter. METHODS: The oxygen tensions (PO2) of 83 pre-heparinized fetal blood samples from umbilical veins were reduced by tonometry to 1.3 kPa (10 mm Hg) and 2.7 kPa (20 mm Hg). The oxygen saturation (SO2) was determined (n=1328) on a reference CO oximeter (ABL625, Radiometer Copenhagen) and on three tested instruments (two CO oximeters: Chiron865, Bayer Diagnostics; ABL700, Radiometer Copenhagen, and a portable blood gas analyser, i-STAT, Abbott). The CO oximeters measure the oxyhemoglobin and the reduced hemoglobin fractions by absorption spectrophotometry. The i-STAT system calculates the oxygen saturation from the measured pH, PO2, and PCO2. The measurements were performed in duplicate. Statistical evaluation focused on the differences between duplicate measurements and on systematic instrumental errors in oxygen saturation analysis compared to the reference CO oximeter. RESULTS: After tonometry, the median saturation dropped to 32.9% at a PO2=2.7 kPa (20 mm Hg), defined as saturation range 1, and to 10% SO2 at a PO2=1.3 kPa (10 mm Hg), defined as range 2. With decreasing SO2, all devices showed an increased difference between duplicate measurements. ABL625 and ABL700 showed the closest agreement between instruments (0.25% SO2 bias at saturation range 1 and -0.33% SO2 bias at saturation range 2). Chiron865 indicated higher saturation values than ABL 625 (3.07% SO2 bias at saturation range 1 and 2.28% SO2 bias at saturation range 2). Calculated saturation values (i-STAT) were more than 30% lower than the measured values of ABL625. CONCLUSION: The disagreement among CO oximeters was small but increasing under deep hypoxemia. Calculation found unacceptably low saturation.

Blood Gas Analysis↗

Satellite and mobile wireless transmission of focused assessment with sonography in trauma.

OBJECTIVES: Focused assessment with sonography in trauma (FAST) can define life-threatening injuries in austere settings with remote real-time review by experienced physicians. This study evaluates vest-mounted microwave, satellite, and LifeLink communications technology for image clarity and diagnostic accuracy during remote transmission of FAST examinations. METHODS: Using a SonoSite, FAST was obtained on three patients with pericardial and intraperitoneal effusions and two control subjects in a remotely located U.S. Army Combat Support Hospital. A miniature vest-mounted video transmitter attached to the SonoSite sent wireless ultrasound video 20 m to a receiving antenna. The signal was then transferred over VSAT satellite systems at 512 kilobaud per second (kbps), INMARSAT satellite systems at 64 kbps, and over LifeLink on a moving ambulance through a metropolitan wireless traffic-management network. Clarity and absence or presence of effusions were recorded by 15 staff emergency physicians. RESULTS: Average sensitivity, specificity, and accuracy were 87% (95% confidence interval [CI]=79% to 95%), 85% (95% CI=81% to 89%), and 86% (95% CI=82% to 90%) for the Premier Wireless Vest; 98% (95% CI=97% to 99%), 83% (95% CI=75% to 91%), and 86% (95% CI=82% to 90%) for VSAT; 95% (95% CI=94% to 96%), 70% (95% CI=58% to 82%), and 75% (95% CI=70% to 80%) for INMARSAT; and 82% (95% CI=73% to 91%), 83% (95% CI=74% to 92%), and 82% (95% CI=78% to 86%) for LifeLink with clarity of 3.0 (95% CI=2.7 to 3.3), 2.9 (95% CI=2.6 to 3.2), 1.3 (95% CI=1.2 to 1.4), and 2.1 (95% CI=1.8 to 2.4), respectively. CONCLUSIONS: Accuracy correlated with clarity. Roaming vest transmission of FAST provides interpretable, diagnostic imagery at the distances used in this study. VSAT provided the best clarity and diagnostic value with the lighter, more portable INMARSAT serving a lesser role for remote clinical interpretation. LifeLink performed well, and further infrastructure improvements may increase clarity and accuracy.

Data Display↗

Neurosonographic features of central nervous system infections in infancy and childhood.

Infections of the central nervous system (CNS) are a serious threat to the developing brain and are a major cause of neurologic handicap in the young. Of the neuroimaging modalities available, cranial ultrasonography has become an important technique in providing information about intracranial infection because of its portability, low cost, minimal morbidity, and diagnostic image quality. Authors of recent reports described ultrasonographic changes in brain parenchyma, extracerebral fluid, and ventricles. Parenchymal changes have been observed with cerebritis, edema, hemorrhage, infarction, and abscess formation; changes in extracerebral fluid include effusion and empyema; and ventricular changes associated with ventriculitis and hydrocephalus have been reliably described. By identifying changes associated with intracranial infections, ultrasonography has emerged as a technique that provides valuable information in making the diagnosis, identifying complications, and directing decisions in management of CNS infection.

Bacterial Infections↗

Misdiagnosis of aortic atresia due to catheter malposition.

A single film portable aortogram through a highly placed umbilical artery catheter suggested aortic atresia, but subsequent study revealed a normal aorta and a patent ductus arteriosus. This demonstrates the importance of proper catheter placement in single film portable aortography, which is a reliable diagnostic tool in the evaluation of distressed neonates.

Aorta↗

[Instrumentation for ultrasound diagnosis of vascular diseases].

The paper describes the computer-based ultra-sound medical instruments worked out by the authors to diagnose the diseases and traumas of the brain, vessels, arteries and cerebral veins as well as of pathologies of the upper and lower extremities. The portable instruments are capable of four diagnostic methods: echoencephalography, echopulsegraphy as well as ultra-sound and transcranial Doppler-graphy.

Arm↗

Clinical diagnosis and assessment of obstructive sleep apnoea syndrome.

Obstructive sleep apnoea (OSA) syndrome is very common, affecting up to 4% of adult males. The pathophysiology of OSA is complex and incompletely understood, but upper airway (UA) obstruction appears to be the net result of an inability of the UA dilating muscles to maintain a patent oropharyngeal airway during sleep. A narrowed UA is common among OSA patients, and in adults this is usually due to nonspecific factors, such as fat deposition in the neck, or abnormal bony morphology of the UA. The present criteria for the diagnosis of OSA are not well-defined, and different centres use different thresholds of apnoea and hypopnoea frequency during sleep to diagnose the clinical syndrome. The advent of many simplified diagnostic systems, some of which are portable and suitable for use in the patient's home, represents a major advance, but many of these systems are poorly validated, and there is no uniformity of measured variables among the various systems, apart from arterial oxygen saturation (Sa,O2). The established prevalence of OSA among the general population implies that most patients with suspected OSA should be initially assessed outside major sleep laboratories, in many cases by clinicians who may not have as detailed an understanding of the syndrome as clinicians who have undertaken specific training in sleep medicine. It is important, therefore, that clear-cut guidelines and criteria be established for the assessment and management of patients with suspected OSA.

Adult↗

[Portable microfocal radiographic devices for medical diagnosis].

The paper outlines two portable microfocal X-ray medical diagnostic devices which have a designing principle in common. The basic features of the devices are as follows: a thin long fight-path tube at whose end there is a massive or shooting target, a three-electrode electron gun, a private-line tungsten loop-shaped cathode, and a magnetic focusing system.

Humans↗