PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60Linked to original sources

Elasticity of peptide omega bonds.

We calculated the changes of the free energy profile of the peptidyl-prolyl torsional angle of the dipeptide valine-proline under pulling forces by simulations. Using a dynamic model built on the equilibrium properties of this system and previously studied dynamic properties of cis-trans isomerization of other dipeptides, we calculated the dynamic viscoelasticity of this degree of freedom. The results show significant differences between how thermal and mechanical forces alter the equilibrium and the dynamics of the isomerization transition. The former does not change the barrier heights but changes the prefactor of the kinetics owing to temperature effects, while the latter changes minima and thus the population. The force that is required to "excite" this degree of freedom is small. Compared to other systems, we found that this degree of freedom becomes already quite rigid at several hertz, which is a much lower value due to the high barrier of the cis-trans isomerization. We also found that the tensile elastic modulus of densely packed omega bonds is at the order of GPa, which is comparable to that of polymer materials. These results give mechanical properties of polyproline elasticity of a local nature and provide guidance for future experimental designs.

Binding Sites↗

Influence of pH on elastic deformability of the human erythrocyte membrane.

Fresh human blood was diluted 1:5000 in buffered saline-sucrose solution and titrated to a pH varying from 4.5 to 10.5 with 0.1 N HCl or 0.1 N NaOH. Circular regions of the membrane of individual cells were then deformed at 25 degrees C by aspiration into a micropipette having an internal tip diameter of 0.9-1.4 micron. A membrane surface elasticity modulus, mu (dyn/cm), was computed from the relationship between length of the aspirated membrane and the deforming pressure according to a two-dimensional membrane model. Surface elasticity increases with decreasing pH and with time after the cell suspension is acidified, rising several orders of magnitude with a t1/2 of 1--5 h as pH is lowered from 7.2 to 4.6. This increase in mu is only partially reversible. pH greater than 7.2 had little effect on mu. Membrane surface elasticity is not affected by variations in external [Ca2+] over the range of 0--50 mM, tonicity of the suspension medium from 275--400 mosM, or age of 0--50 h. Addition of 50 mM NaHCO3 to the medium increases the rate of change of mu at a given pH. These results suggest that the elastic properties of the red cell membrane are largely determined by interactions among structural proteins located on the cytoplasmic surface of the membrane and that these interactions are initiated by changes in intracellular pH.

Elasticity↗

Constricting and stiffening action of atropine on aortic response to angiotensin in dogs.

The elasticity of the thoracic aorta was studied in nine dogs instrumented with a pressure microtransducer and two ultrasonic crystals diametrically fixed in the adventitia. Systolic and diastolic changes in pressure and diameter were used to calculate Peterson and incremental elastic moduli. Acute hypertension was induced by infusions of angiotensin performed 1) during the control period, 2) after propranolol (1.5 mg/kg), 3) after atropine (0.2 mg/kg), and 4) after propranolol plus atropine. Absolute and percent variations of mean diameter were correlated to pressure in the control period and after autonomic blockade (p less than 0.01). The slopes of these correlations were not different between propranolol and control groups, but were lower with atropine (p less than 0.01) and with atropine plus propranolol (p less than 0.001) than in the control period. Correlations were also found between Peterson and incremental elastic moduli and mean pressure in the control period and after blockade (p less than 0.001). No differences of slopes existed between propranolol and control groups, but the slope of the correlation relative to the incremental elastic modulus was higher with atropine than in the control period (p less than 0.05), and the slopes of the correlations relative to the Peterson and the incremental elastic moduli were respectively higher with atropine plus propranolol than in the control period (p less than 0.05, p less than 0.05). Thus, atropine decreased the distention and increased the stiffness of the aorta in response to acute angiotensin-mediated hypertension.

Angiotensin II↗

Endothelial function and mechanical properties of the common carotid artery in children on parenteral nutrition.

Intravenous administration of nutrition mixtures induces endothelial damage and arterial wall remodeling in animal models. To study endothelial function and common carotid artery mechanical properties in children receiving parenteral nutrition, we used noninvasive ultrasonic measurements in 18 children on parenteral nutrition and 18 controls. No difference appeared in the geometry of the common carotid artery (intima media thickness, systolic and diastolic diameters) between the patients on parenteral nutrition and the controls. The incremental elastic modulus was significantly higher in the patients on parenteral nutrition (1.8 +/- 0.4 versus 1.4 +/- 0.5 4 mm Hg x 10(3), p < 0.05) reflecting alteration of the elastic properties of the arterial wall independent of the vessel geometry. The flow-mediated dilatation of the brachial artery was significantly lower in the patients on parenteral nutrition (6 +/- 3 versus 8 +/- 3%, p < 0.05), whereas the dilatation after glyceryl trinitrate administration was similar (22 +/- 9 versus 25 +/- 9%). Children on parenteral nutrition exhibit endothelial dysfunction and altered stiffness of the common carotid artery. The noninvasive methods used in this study may prove useful for objectively determining the effects of various preventive methods.

Adolescent↗

Measurement of Young's modulus in the in vivo human vocal folds.

Currently, surgeons have no objective means to evaluate and optimize results of phonosurgery intraoperatively. Instead, they usually judge the vocal folds subjectively by visual inspection or by listening to the voice. This paper describes a new device that measures Young's (elastic) modulus values for the human vocal fold intraoperatively. Physiologically, the modulus of the vocal fold may be important in determining the nature of vocal fold vibration in normal and pathologic states. This study also reports the effect of recurrent laryngeal nerve stimulation on Young's modulus of the human vocal folds, measured by means of transcutaneous nerve stimulation techniques. Young's modulus increased with increases in current stimulation to the recurrent laryngeal nerve. Ultimately, Young's modulus values may assist surgeons in optimizing the results of various phonosurgeries.

Adult↗

In vivo assessment of architecture and micro-finite element analysis derived indices of mechanical properties of trabecular bone in the radius.

Measurement of microstructural parameters of trabecular bone noninvasively in vivo is possible with high-resolution magnetic resonance (MR) imaging. These measurements may prove useful in the determination of bone strength and fracture risk, but must be related to other measures of bone properties. In this study in vivo MR imaging was used to derive trabecular bone structure measures and combined with micro-finite element analysis (microFE) to determine the effects of trabecular bone microarchitecture on bone mechanical properties in the distal radius. The subjects were studied in two groups: (I) postmenopausal women with normal bone mineral density (BMD) (n = 22, mean age 58 +/- 7 years) and (II) postmenopausal women with spine or femur BMD -1 SD to -2.5 SD below young normal (n = 37, mean age 62 +/- 11 years). MR images of the distal radius were obtained at 1.5 T, and measures such as apparent trabecular bone volume fraction (App BV/TV), spacing, number and thickness (App TbSp, TbN, TbTh) were derived in regions of interest extending from the joint line to the radial shaft. The high-resolution images were also used in a micro-finite element model to derive the directional Young's moduli (E1, E2 and E3), shear moduli (G12, G23 and G13) and anisotropy ratios such as E1/E3. BMD at the distal radius, lumbar spine and hip were assessed using dual-energy X-ray absorptiometry (DXA). Bone formation was assessed by serum osteocalcin and bone resorption by serum type I collagen C-terminal telopeptide breakdown products (serum CTX) and urinary CTX biochemical markers. The trabecular architecture displayed considerable anisotropy. Measures of BMD such as the ultradistal radial BMD were lower in the osteopenic group (p<0.01). Biochemical markers between the two groups were comparable in value and showed no significant difference between the two groups. App BV/TV, TbTh and TbN were higher, and App TbSp lower, in the normal group than the osteopenic group. All three directional measures of elastic and shear moduli were lower in the osteopenic group compared with the normal group. Anisotropy of trabecular bone microarchitecture, as measured by the ratios of the mean intercept length (MIL) values (MIL1/MIL3, etc.), and the anisotropy in elastic modulus (E1/E3, etc.), were greater in the osteopenic group compared with the normal group. The correlations between the measures of architecture and moduli are higher than those between elastic moduli and BMD. Stepwise multiple regression analysis showed that while App BV/TV is highly correlated with the mechanical properties, additional structural measures do contribute to the improved prediction of the mechanical measures. This study demonstrates the feasibility and potential of using MR imaging with microFE modeling in vivo in the study of osteoporosis.

Aged↗

Mechanical properties of metaphyseal bone in the proximal femur.

We used a three-point bending test to investigate the structural behavior of 123 rectangular flat plate specimens harvested from the metaphyseal shell of the cervical and intertrochanteric regions of five fresh/frozen human proximal femora. For comparison purposes, 36 specimens of similar geometry were also fabricated from bone of the femoral diaphysis. All specimens were oriented in either the local longitudinal or transverse directions. The mean longitudinal elastic modulus was 9650 +/- 2410 (SD) MPa and demonstrated a 24% decrease from that measured for the diaphysis (12500 +/- 2140 MPa) using the same testing technique. However, the transverse elastic moduli did not differ significantly between the proximal (5470 +/- 1720 MPa) and diaphyseal (5990 +/- 1520 MPa) specimens. The globally averaged values for the ultimate tensile strengths of the metaphyseal shell were 101 +/- 26 MPa in the longitudinal and 50 +/- 12 MPa in the transverse directions. These compared with diaphyseal values of 128 +/- 16 MPa and 47 +/- 12 MPa, respectively. While these differences were largely due to the reduced density of the proximal specimens, a slight decrease in transverse anisotropy for the proximal specimens was also noted by comparing the ratio of longitudinal to transverse moduli (1.76) and tensile strength (2.02) to the diaphyseal values (2.09 and 2.71, respectively). Use of these data should lead to improved performance of analytical models for the proximal femur, and thus help focus increased attention on the structural contribution of trabecular bone to the strength and rigidity of the proximal femur.

Acrylic Resins↗

Ultrasonic imaging of the stress distribution in elastic media due to an external compressor.

We describe an experimental ultrasonic method capable of imaging the two-dimensional distribution of longitudinal stress in an elastic, tissue-like material due to an external compressor of arbitrary size or shape and boundary conditions. The method involves the use of a compressor and an opposing ultrasonic transducer. Local strains are derived from the ultrasonic backscatter signals before and after compression using cross correlation analysis. The strain distribution is converted to a stress map by assuming a linear stress-strain relationship. The technique is useful for quantifying the corrections that must be made to images of the elastic modulus of tissue (elastograms) due to the effects of compressor size and shape, depth and boundary conditions. It is also useful for experimental modeling of stress distributions in elastic media.

Artifacts↗

The influence of water content, chemical treatment and temperature on the rheological properties of stratum corneum.

The elastic modulus is determined as a function of water content for untreated stratum corneum, and stratum corneum treated with urea and LiBr. The modulus is also determined for stratum corneum at temperatures from 2 degrees C to 45 degrees C and on samples with the water solubles extracted. The modulus is independent of temperature, but may be modified by binding of small molecules to the protein in stratum corneum. The modulus is found to be a function of water content, not water activity.

Body Water↗

The measurement of the variation in the surface strains of Achilles tendon grafts using imaging techniques.

Uniaxial tensile tests are commonly used to characterize the structural and material properties of tendons and ligaments. During these tests, the stress and strain distributions applied to the specimen are assumed to be uniform. However, few studies have investigated the strain distributions throughout the tissue. The purpose of this study was to use imaging techniques to measure the strains around the circumference of 11 mm wide Achilles tendon grafts during a uniaxial tensile test. Pairs of radiopaque beads with a diameter of 2mm were affixed around the mid-substance of the tendon in four different locations. The motion of the beads was recorded using a cine fluoroscope. This system was shown to measure the displacement of the beads with an accuracy of 0.02 mm. During the uniaxial tensile test, large variations in local tissue strains were observed. At 10 MPa of applied stress, the local tissue strain varied from an average of 2.5-8.7%, an increase in strain of more than three times. As a result of these large variations, the modulus calculated from the stress-strain data varied from an average of 217 to 897 MPa, an increase of approximately 4 times. Furthermore, these data suggest that underestimates of the elastic modulus may result if a uniform strain distribution is assumed. These results indicate that during uniaxial tensile tests, the assumption of uniform stress and strain distributions should be carefully considered and small, uniform specimens should be used when measuring the material properties of soft tissues.

Achilles Tendon↗

Dynamic viscoelastic properties of processed soft denture liners: Part I--Initial properties.

This research evaluated the dynamic viscoelastic properties of 12 laboratory-processed soft denture liners. Specimens, 1.4 x 3 x 40 mm, were prepared according to the manufacturer's instructions. Five specimens of each material were tested under applied strain frequencies of 1, 5, or 10 Hz and temperatures of 23 degrees C and 37 degrees C. The values at 37 degrees C and 1 Hz were judged most important because they closely approximate the service environment; therefore material comparisons were made for these conditions. Samples were tested with a custom-made dynamic viscoelastometer. The statistical significance of the results was tested by ANOVA and Scheffe's intervals test. Large differences in the storage modulus (elastic stiffness) were found. One acrylic resin, Verno-Soft, showed significantly higher storage moduli than the other materials. The viscous behavior of the materials was reflected by the loss modulus; here large differences were also found. Verno-Soft again exhibited much higher values than all of the other materials. Three other acrylic resins (Super Soft, Soft-Pak, and Justi Soft) also showed significantly higher loss moduli than the other materials. Significant differences were found in the damping factor between many of the materials. Most of the acrylic and vinyl resins had higher damping factors than the silicone and polyphosphazine rubbers. The values of the storage moduli, loss moduli, and the damping factor were affected by temperature and by applied strain frequency with some materials.

Acrylic Resins↗

Photopolymerization of polyacrylamide gels with methylene blue.

Photopolymerization of polyacrylamide gels in the presence of methylene blue (100 microM) and a redox couple (1 mM sodium toluenesulfinate, a reducer, and 50 microM diphenyliodonium chloride, an oxidizer) has been investigated. The gel point, i.e. the time needed for onset of gelation upon illumination, has been found to lengthen progressively at lower temperatures and at lower light intensities. If the three catalysts are progressively diluted, the gel point does not vary for a threefold dilution, but gelation is greatly hampered below a 1:5 dilution of the three effectors. Photobleaching has been assessed as a function of liquid layer thickness (from 0.5 to 2 mm), of a progressive dye dilution (down to a fourfold dilution) and as a function of temperature. A maximum of elastic modulus is located in correspondence to a minimum of permeability (both situated at 5% cross-linker). It is found that methylene blue-activated polymerization produces polyacrylamide gels with elastic properties which are higher than in persulfate-activated gels, so far the most popular matrices for electrokinetic separations. Due to the ease of preparation, the full control of all experimental parameters, and the lack of oxidizing power of this catalyst system (as opposed to the strong oxidation power of persulfate catalysis), methylene blue catalysis is advocated as a valid alternative to other redox systems.

Acrylic Resins↗

Characterization of new acrylic bone cements prepared with oleic acid derivatives.

Acrylic bone-cement formulations were prepared with the use of a new tertiary aromatic amine derived from oleic acid, and also by incorporating an acrylic monomer derived from the same acid with the aim of reducing the leaching of toxic residuals and improving mechanical properties. 4-N,N dimethylaminobenzyl oleate (DMAO) was used as an activator in the benzoyl-peroxide radical cold curing of polymethyl methacrylate. Cements that contained DMAO exhibited much lower polymerization exotherm values, ranging between 55 and 62 C, with a setting time around 16--17 min, depending on the amine/BPO molar ratio of the formulation. On curing a commercial bone cement, Palacosreg R with DMAO, a decrease of 20 C in peak temperature and an increase in setting time of 7 min were obtained, the curing parameters remaining well within limits permitted by the standards. In a second stage, partial substitution of MMA by oleyloxyethyl methacrylate (OMA) in the acrylic formulations was performed, the polymerization being initiated with the DMAO/BPO redox system. These formulations exhibited longer setting times and lower peak temperatures with respect to those based on PMMA. The glass transition temperature of the experimental cements were lower than that of PMMA cement because of the presence of long aliphatic chains of both activator and monomer in the cement matrix. Number average molecular weights of the cured cements were in the range of 1.2x10(5). PMMA cements cured with DMAO/BPO revealed a significant (p<0.001) increase in the strain to failure and a significant (p<0.001) decrease in Young's modulus in comparison to Palacosreg R, whereas ultimate tensile strength remained unchanged. When the monomer OMA was incorporated, low concentrations of OMA provided a significant increase in tensile strength and elastic modulus without impairing the strain to failure. The results demonstrate that the experimental cements based on DMAO and OMA have excellent promise for use as orthopaedic and/or dental grouting materials.

Acrylates↗

Instantaneous blood flow, impedance and elastic properties computed in man from aortic pulse waves.

A mathematical model of the pressure-flow relationship in the arterial circulation and its possible use in routine hemodynamics in man are described. The instantaneous blood flow velocity in the ascending aorta can be calculated from two pressure curves simultaneously recorded 5 cm apart. The mechanical aortic input impedance is computed from the recorded pressure and the calculated blood flow velocity curves. Projection of the pulse waves on a time-length plane leads to the determination of the pulse wave velocity and then an estimation of the elastic modulus of the aortic wall.

Aorta↗

A study on the effect of drying techniques on the mechanical properties of pellets and compacted pellets.

Microcrystalline cellulose (MCC) pellets produced by a standard extrusions/spheronisation process with a 40% ethanol/water mixture as the fluid component, were dried by four different techniques, namely: freeze-drying, fluid-bed drying, hot air oven drying and desiccation with silica-gel to less than 5% (w/w) water content. A 1.0-1.18mm size fraction of the dried pellets were characterised structurally and mechanically in terms of, shape, density/porosity (open and closed), pore volume/pore volume distribution, surface area, surface tensile strength, shear strength, deformability, linear strain and elastic modulus. An amount of 600, 700 and 750mg of the same size fraction of each pellet batch were compacted to the same tablet thickness and the tensile strength and volumetric elastic recovery of the resulted compacts were determined. Analysis of variance was used to assess the significance of the drying process on the property of the pellets and their compacts. The drying process did not influence the shape of the pellets, but all the other properties were affected to some extent. Pellets dried by freeze-drying were more porous, with most of the pores open to the atmosphere and had a higher surface area than pellets dried by the other methods. Pellets dried by desiccation contained the highest proportion of closed pores. The decrease in tensile strength of the pellets, which occurred with the increase in porosity could presumably be due to ease of crack initiation and propagation between the MCC fibres. The weaker pellets broke instantly before they were subjected to appreciable strain. The porous pellets needed a higher compressing pressure and work of compaction to produce tablets of the same mass and dimensions. This reflected their compressibility, i.e. relative decrease in volume of the pellet bed during compression. The strength and volumetric elastic recovery of the compacts increased with the increase of their porosity. The drying techniques, which produced porous, deformable and weak pellets, produced stronger tablets. The value of the volumetric elastic recovery of the compacts was also observed to increase with the value of compaction pressure.

Cellulose↗

Interfacial fracture toughness between bovine cortical bone and cements.

To evaluate the bonding strength of the interfaces within the cemented arthroplasty system, various mechanical tests have been used. Conventional push-out and pull-out tests cannot reveal the actual bonding property of the interface because of the significant influence of surface roughness on the measured adhesion and the failure to account for the mismatch of elastic modulus across the interface. An alternative fracture mechanics approach, which considers the mix of opening and shear modes of the crack tip loading associated with the testing system and the elastic mismatch of materials across the interface, was used to evaluate the bonding ability of various cements. The four-point bend interfacial delamination test by Charalambides et al. (J. Appl. Mech. 56 (1989) 77; Mech. Mater. 8 (1990) 269) was used to quantify the bonding ability of cements. This method is arguably more suitable since the applied loading mode is comparable to the nature of loading within the prosthetic system, which is primarily bending. The bovine bone specimens were polished to mirror finish to eliminate bonding by mechanical interlocking. The results revealed minimal bonding for the conventional bone cement (PMMA) whereas substantial bonding was evident for the glass-ionomer cements tested. However, only the conventional glass-ionomer cements showed evidence of bonding on testing, while the resin-modified glass-ionomer cement (poly-HEMA) did not. The latter appeared to debond before testing because of excessive expansion stresses associated with swelling in water.

Adhesiveness↗

Mechanical properties of dental investment materials.

Measurement of the elastic modulus (E) of investment materials has been difficult because of their low strength. However, these values are essential for engineering simulation and there are many methods available to assess the elasticity of materials. The present study compared two different methods with one of the methods being non-destructive in nature and can be used for specimens prepared for other tests. Two different types of investment materials were selected, gypsum-and phosphate-bonded. Method 1 is a traditional three-point bending test. Twelve rectangular bars with dimension of (70 x 9 x 3 mm) were prepared and placed on supports 56.8 mm apart. The test was conducted at a cross-head speed of 1 mm/min by use of a universal testing machine. The load applied to the test specimen and the corresponding deflection were measured until the specimen fractured. The E value was calculated from a linear part of the stress-strain plot. Method 2 is an ultra micro-indentation system to determine near surface properties of materials with nanometer resolution. The measurement procedure was programmed such that the specimens were indented with an initial contact force of 5 mN then followed by a maximum force of 500 mN. Measurement consisted of 10 indentations conducted with a spherical stainless steel indenter (R = 250 microm) that were equally spaced (500 microm). The E value rose asymptotically with depth of penetration and would approach the three-point bending test value at approximately four time's maximum contact depth for both materials. Both methods are practical ways of measuring the E of investment materials.

Journal Article↗

The changes in the tensile properties of tendons after freeze storage in saline solution.

The objective of this study is to evaluate the influence of saline solution (0.9 per cent NaCl) on the tensile properties of freeze-stored tendons. Firstly, 170 pieces of chicken flexor digitorum profundus tendons were retrieved and wrapped in saline-soaked gauze before they were stored at -40degreesC. Then specimens were tensile tested at various time points over 360 days, scanning electron microscopy (SEM) was performed on fresh specimens, and specimens were freeze-stored for 233 days to investigate microstructure change after freeze storage. The mean values of strain ultimate tensile strength (UTS) did not deviate significantly (analysis of variance; p = 0.249) following freeze storage while the UTS and elastic modulus increased gradually with the duration of freeze storage and the growth became significant (p < 0.01) for durations longer than 70 and 40 days respectively. The SEM study showed that the collagen fibre density of specimens stored for 233 days decreased because of porosity growth. These findings suggested that the saline increased the tensile strength and modulus of the collagen.

Animals↗