Partial resolution of the enzymes catalyzing photophosphorylation. 8. Properties of silicotungstate-treated subchloroplast particles.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Dental resin composites need to be strengthened in order to improve their performance in large stress-bearing applications such as crowns and multiple-unit restorations. Recently, silica-fused ceramic whiskers were used to reinforce dental composites, and the whisker-to-silica ratio was found to be a key microstructural parameter that determined the composite strength. The aim of this study was to further investigate the effects of whisker-to-silica ratio on the fracture toughness, elastic modulus, hardness and brittleness of the composite. Silica particles and silicon carbide whiskers were mixed at whisker:silica mass ratios of 0:1, 1:5. 1:2, 1:1, 2:1, 5:1, and 1:0. Each mixture was thermally fused, silanized and combined with a dental resin at a filler mass percentage of 60%. Fracture toughness was measured with a single-edge notched beam method. Elastic modulus and hardness were measured with a nano-indentation system. Whisker:silica ratio had significant effects on composite properties. The composite toughness (mean+/-SD; n = 9) at whisker:silica = 2:1 was (2.47+/-0.28) MPa m(1/2), significantly higher than (1.02+/-0.23) at whisker:silica = 0:1, (1.13+/-0.19) of a prosthetic composite control, and (0.95+/-0.11) of an inlay/onlay composite control (Tukey's at family confidence coefficient = 0.95). Elastic modulus increased monotonically and hardness plateaued with increasing the whisker:silica ratio. Increasing the whisker:silica ratio also decreased the composite brittleness, which became about 1/3 of that of the inlay:onlay control. Electron microscopy revealed relatively flat fracture surfaces for the controls, but much rougher ones for the whisker composites, with fracture steps and whisker pullout contributing to toughness. The whiskers appeared to be well-bonded with the matrix, probably due to the fused silica producing rough whisker surfaces. Reinforcement with silica-fused whiskers resulted in novel dental composites that possessed fracture toughness two times higher than, and brittleness less than half of current dental composites.
In 37 patients with gastroduodenal ulcer disease were revealed the changes of concentration of aluminium and silicon in blood, of acetylcholine in erythrocytes and plasma, the cholinesterase (ACHE) activity depending on the disease clinical course, the ulcer size; the interconnection between the blood cholinergic activity and the contents of aluminium and silicon; the influence of aluminium and silicon ions on the ACHE activity of plasma and erythrocytes, what is confirmed by the correlational analysis data and gives and arguments for application of chemical compounds with aluminium and silicon in treatment and prophylaxis of an ulcer disease recurrence.
Recently, some works have focused attention on the reactivity of the silicon atom with closed-shell molecules. With CO, silicon may form a few relatively stable compounds, i.e., Si(CO), Si(CO)(2), and Si[C(2)O(2)], while the existence of polycarbonyl (n > 2) silicon complexes has been rejected by current literature. In this paper, the reaction of silicon with carbonyl has been reinvestigated by density functional calculations. It has been found that the tetracoordinated planar Si(CO)(4) complex is thermodynamically stable. In Si(CO), silicon carbonyl, and Si(CO)(2), silicon dicarbonyl, the CO moieties are datively bonded to Si, and Si[C(2)O(2)], c-silicodiketone, is similar to the compounds formed by silicon and ethylene; Si(CO)(4), silicon tetracarbonyl, may be viewed as a resonance between the extreme configurations (CO)(2)Si + 2CO and 2CO + Si(CO)(2). A detailed orbital analysis has shown that the Si bonding with four CO is consistent with the use of sp(2)d-hybridized orbitals on silicon, giving rise to a planar structure about Si.
Explore the source record for details and available documents.
The effectiveness of activated charcoal in direct hemoperfusion (DHP) has been recognized, but there are still problems with a decrease in solid components of blood and of dimishing adsorption capacity by coating layers on the surface of the sorbents in DHP. In the present study, we have developed activated charcoal derived from thermosetting resin, coated with silicone, and have observed changes in blood components after a 3 hr DHP. Adsorption capacity of the activated charcoal was determined in vitro, and was compared with noncoated charcoal and poly(hydroxyethyl methacrylate) (PHEMA) coated charcoal. Reduction in leukocyte and platelet counts was less with the silicone coated and PHEMA coated charcoals than with the noncoated charcoal. Variations in leukocyte counts and platelet counts were less in DHP with silicone-coated charcoal than with the others. Adsorption of the solid components of blood on the silicone-coated charcoal, examined by scanning electron microscopy after DHP, was very slight, showing its excellent applicability to DHP therapy. The degree of adsorption of various amino acids and related compounds on the silicone-coated charcoal was comparable to that on the noncoated charcoal. Thus, there seems only slight reduction in the degree of adsorption on the silicone-coated charcoal.
The main objective of the present paper is to report on the concentration of silicon carbide (SiC) fibres, crystalline silica and respirable dust in a Canadian SiC production plant and to compare the results with earlier investigations. The second objective is to tentatively explain the differences in concentration of the fibrogenic substances between different countries. The assessment of SiC fibres, dusts, respirable quartz and cristobalite was performed according to standard procedures. The highest 8 h time-weighted average concentrations of fibres were found among the crusher and backhoe attendants and the carboselectors with an arithmetic mean of 0.63 fibres ml(-1) for the former group and 0.51 fibres ml(-1) for the latter group. The results of respirable SiC fibres in the Canadian plant were lower than in the Norwegian and Italian industries. Most of the 8 h time-weighted average concentrations for quartz were less than or around the limit of detection of 0.01 mg m(-3). The maximum 8 h time-weighted average concentration for quartz was found among the carboselectors (0.157 mg m(-3)), followed by the labourers (0.032 mg m(-3)). Similarly, most of the 8 h time-weighted average cristobalite measurements were less than the limit of detection of 0.01 mg m(-3) except for the carboselectors where it was found to be 0.044 mg m(-3). The assessment of the Italian occupational settings exposure demonstrated elevated quartz concentrations, while cristobalite was absent. The authors have concluded that the investigations that were performed in the last two decades in this field by researchers from different countries seem to support that SiC fibres (whiskers) constitute a major airborne health hazard.
Silicone materials have been used in medical applications for at least 30 years. Despite this long history of use the question whether silicones can mediate an immunological reaction that may be detrimental to the host remains unanswered. Most studies on the biocompatability of silicones conclude that silicones are chemically stable compounds, which however are often capable of eliciting a benign chronic inflammatory response. Recently, our laboratory has conducted a series of animal experiments aimed at determining the immunological adjuvancy potential of silicone-gel taken from commercial breast implants. Our previous studies have indicated that silicone-gel is a potent humoral (antibody) adjuvant. Our present studies have found that silicone-gel is capable of eliciting auto-antibodies to rat thyroglobulin and bovine collagen II. However this immune response did not produce any histological evidence of thyroiditis or arthritis. Theories to explain why silicone-gel behaves as an adjuvant are discussed along with discussion of the hypothesis on the desirability of replacing silicone-gel with a more hydrophilic material in bioimplants.
This study examined the average surface roughness (Ra, micron) of three packable composites and one hybrid composite cured against mylar, before and after treatment with a fine finishing diamond bur, a resin finisher followed by fine and extrafine polishing paste, two silicone-based finishing and polishing systems, fine and super-fine aluminum-oxide polishing disks, a silicon carbide-impregnated polishing brush and a surface-penetrating composite sealant. Additionally, the Ra was examined for one of the packable composites before and after treatment with a finishing carbide, prior to the finishing and polishing procedures detailed above. The finishing diamond significantly increased the Ra for all composites (ALERT, SureFil, Solitaire and Z-100). The finishing carbide used with SureFil (SureFil + C) also increased the Ra; however, it also produced surfaces up to 3.5x smoother when compared to SureFil surfaces finished with the diamond. Overall, Sof-Lex Contouring and Polishing Discs were able to produce the smoothest surfaces, followed by the Jiffy Composite Polishing Cups, the Enhance Composite Finishing & Polishing System/Prisma-Gloss Composite Polishing Paste, the Diacomp Intra-Oral Composite Polishers and the Jiffy Composite Polishing Brushes, respectively. The smoothest surfaces were produced using Z-100, followed by SureFil + C (carbide finishing bur), Solitaire, SureFil and ALERT, respectively. In general, Protect-It Composite Surface Sealant had little effect on the Ra, except with ALERT, where a slight increase in Ra was observed.
The strength and fracture resistance of dental resin composites need to be improved to extend their use to large stress-bearing crown and multiple-unit applications. Recent studies showed that the addition of ceramic whiskers significantly reinforced resin composites. The aim of the present study was to use a silicon carbide whisker-silica particle mixture to reinforce resin composites, and to investigate the effect of whisker-silica mixture heat-treatment on composite properties. The whiskers were blended with silica particles and were thermally fused in an attempt to roughen the whiskers for improved retention in the matrix. The mixtures were heat-treated at temperatures of 500, 650, 800, 950, and 1100 degrees C for 10 min, 30 min, and 3 h. The mixtures were then silanized, incorporated into a dental resin, and the paste was placed into 2 x 2 x 25 mm molds and heat-cured at 140 degrees C for 30 min. A 3-point flexural test was used to measure flexural strength and work-of-fracture. Two commercial indirect composites were tested as controls. Two-way ANOVA showed that there was no significant effect from temperature or time. Therefore, all the whisker-silica mixture samples were combined into one group (n = 96), and compared to composites filled with silica only or whisker only, and the two indirect control composites. The whisker-silica mixture group had a flexural strength (mean +/- SD) of (186 +/- 24) MPa, significantly higher than (99 +/- 29) MPa for silica only, (131 +/- 22) MPa for whisker only, and (109 +/- 23) MPa and (114 +/- 18) MPa for the two indirect composites (Tukey's multiple comparison test; family confidence coefficient = 0.95). Similar results were obtained on work-of-fracture. Scanning electron microscopy revealed rough fracture surfaces for the whisker-silica composites, indicating crack deflection and bridging by whiskers as toughening mechanisms. Whisker-silica mixture minimized whisker entanglement and enhanced whisker-resin bonding, resulting in substantially stronger and tougher dental resin composites.
Explore the source record for details and available documents.
OBJECTIVES: To measure the water sorption and solubility of different resin-based restorative dental materials. METHODS: Eight commercial restorative materials were selected: two resin composites (Z100 and Prodigy), four polyacid-modified resin composites (Compoglass, Compoglass F, Dyract and Dyract AP), and two light-cured glass ionomers (Vitremer and Fuji II LC). Five disc specimens were prepared of each material, following the manufacturer's instructions, and were grounded wet with silicon carbide paper. Water sorption and solubility of the different materials were calculated by means of weighting the samples before and after water immersion and desiccation. Data were analyzed by one-way ANOVA and Student-Newman-Keuls tests (P<0.05). RESULTS: Compoglass and Compoglass F showed the lowest values of water sorption and solubility, while Vitremer and Fuji II LC displayed the highest values. Solubility values of Prodigy, Z100, Dyract and Dyract AP did not show significant differences among them, while their water sorption values attained some differences and were lower for Prodigy followed by Dyract and Z100. CONCLUSIONS: The attained water sorption and solubility values are mainly influenced by the generic type of material and variations occurring between materials of the same type may result from differences in resin matrix compositions.
A method is presented for the analysis of shellfish tissue for domoic acid, a neurotoxic amino acid responsible for cases of amnesic shellfish poisoning. Tissue extracts are first taken through a two-stage solid-phase extraction clean-up, using reversed-phase and strong cation exchange cartridges. A two-stage derivatization, using N-methyl-bis-trifluoroacetamide followed by either N-methyl-tert-butyldimethylsilyltrifluoroacetamide or N, O-bis-trimethylsilyltrifluoroacetamide, is then used to produce an N-trifluoroacetyl-O-silyl derivative which can be analyzed by mass spectrometry with introduction via direct inlet probe, moving-belt liquid chromatograph/mass spectrometer interface, or capillary column gas chromatography. The N-trifluoroacetyl-O-tert-butyldimethylsilyl derivative, which has good stability towards hydrolysis, provides a spectrum well suited to gas chromatography/mass spectrometry (GC/MS) using selected ion recording. GC/MS data for two related compounds, kainic acid and dihydrokainic acid, are also reported. The latter is used as an internal standard for quantification of domoic acid, although the method reported is intended primarily for confirmation of the toxin and related compounds in shellfish tissue.
The reaction of trimethylsilylimidazole (TSIM) and 3-keto-5,10-epoxy-nor-19-methylandrostanone 3 and its 17-acetate analog 4 was examined at two different temperatures. In both compounds, reaction at 90 degrees C gave predominantly a delta 3-silyl-enol ether plus a minor product as a result of the epoxide ring opening. Under reflux conditions, besides the aforementioned products, aromatization of the A-ring was observed as a major process. The results suggest the potential use of silylation reactions with epoxyketones towards the synthesis of aromatic compounds.
PURPOSE: To measure and compare three-body wear and Vickers hardness at depths of 0 mm and 2 mm in two composite resin materials cured with either a low irradiance light emitting diode (LED) or a quartz tungsten halogen (QTH) light-curing unit (LCU) in which exposure duration with the LED was increased to deliver equivalent radiant exposure in the 450-490 nm wavelength range. METHODS: The VIP QTH and Freelight LED LCU's were obtained and the emission spectrum of each was determined using a Spectra Pro 750 spectrograph. Irradiance in the 450-490 nm range for each LCU was determined by calculating the area under the spectral curve. Curing of two composite resins (Z100 and Esthet-X) with equivalent radiant exposure within this prescribed wavelength range was achieved by increasing the irradiation time of the LED 33% from 30-40 seconds to compensate for its lower irradiance (Table 1). The resulting radiant exposure of 8.40 J/cm2 was roughly equivalent to the radiant exposure produced in 30 seconds by the QTH LCU (8.67 J/cm2). The cured specimens were polished with progressively fine wet silicon carbide papers to 600 grit and stored in distilled water at 37 degrees C for 24 hours prior to evaluating hardness and wear. Indentations for Vickers hardness testing were produced by applying a 0.5 kg load with a 15-second dwell time. Equivalent degree of cure was established indirectly through Vickers hardness numbers for the top and bottom surface of 2 mm thick disks of each material cured with each light (N = 3/group). Hardness ratios were computed by dividing mean bottom hardness by mean top hardness within each group. Three-body wear testing (N = 10/group) was performed on similarly fabricated specimens with a mechanical wear device using 44 microm unpolymerized PMMA beads as a simulated food bolus. The composite resin samples opposed spherical, stainless steel styli. A 75 N contact force was applied at 1.2 Hz for 100,000 cycles. Profilometry was used to quantify localized wear of the resin. Multivariate ANOVA and the Tukey-Kramer post hoc test (alpha = 0.05) were used to assess differences in hardness and wear of the materials. RESULTS: With respect to hardness, no difference was noted between top and bottom specimen sides based on material or curing method. Specimens cured using the LED exhibited hardness ratios approaching unity. No significant difference in hardness was found for the main effect of light used, but the main effect of material was highly significant. This was primarily because Z100 cured with the LED demonstrated statistically higher hardness than the other three groups, which were statistically similar. No significant difference in wear was found based on the light used, with the lowest mean wear seen in Z100 cured with the LED. Overall, Z100 exhibited significantly greater surface hardness (P < 0.001) and significantly less wear (P < 0.01) compared to Esthet-X
The regioselectivity of Pd-catalyzed malonate additions and arylations to cycloalkenyl esters can be predicted by completing a stereochemical analysis of the Pd-pi-allyl complex. The Pd-catalyzed malonate additions which have the greatest degree of regioselectivity are in which substituents have a steric influence in blocking the incoming nucleophile. Cyclopentenyl substrates displayed lower regioselectivity than the cyclohexyl counterparts presumably due to increased planarity of the system. Arylations using tin and hypervalent silicon reagents were compared.
A series of mesostructured Cu-SiO2 composites have been synthesized with sodium metasilicate (Na2SiO3) and cuprammonia nitrate (Cu(NH3)4(NO3)2) respectively used as Si and Cu sources. The synthetic procedures were conducted at room temperature, and cetyltrimethylammonia bromide was used as a template. Under our experimental conditions, ordered mesoporous Cu-SiO2 composites could be obtained with a copper content up to 16.8 wt %. Average pore diameters (2.80-3.15 nm), wall thickness (1.30-2.20 nm), and specific surface area (1020-690 m2/g) are found to vary linearly with copper content (0-16.8 wt %). Results of thermal gravimetry-differential thermal analysis reveal the collapse temperature of the order structure starts at approximately 1250 K for mesoporous Cu-SiO2 with 16.8 wt % copper content. As indicated by the outcomes of inductively coupled plasma and X-ray photoelectron spectroscopy studies, copper is mainly incorporated inside the pore wall rather than embedded on the wall surface. Copper species strongly interact with silica, and calcination at high temperatures cannot cause phase separation between silica and copper oxide. Cu status in mesoporous Cu-SiO2 composites is similar to that in copper silicate in neighboring structures. Based on the results, a S+ I- I+ I- mechanism is proposed in which copper entities are surrounded by silicon species during synthesis of the mesostructured composite.
The surface and transport properties of water-swollen silicone rubber-hydrogel composites were investigated. Surface wettability of these materials, composed of a polysiloxane matrix and the hydrogel phase consisting of very fine particles of lightly cross-linked poly(2-hydroxyethylmethacrylate), increased markedly with increasing content of the hydrogel phase. For composite materials containing a lightly cross-linked 2-hydroxyethylmethacrylate (HEMA)-methacrylic acid (MAA) copolymer and polymethacrylic acid (PMAA) as the hydrogel phase, permeability to water-soluble organic compounds and drugs were measured. The permeability varied within a broad range depending on the composition and content of the hydrogel phase. High permeation rates could be obtained while still retaining relatively fair mechanical properties. Relationships between the composition of silicone rubber-hydrogel composites, their structure and the permeation coefficients of the individual permeates are discussed.