PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “nodulation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60Linked to original sources

Computed tomography-guided pulmonary nodule localization before thoracoscopic resection.

PURPOSE: To assess the success rate and complication rate of a CT-guided pulmonary nodule-marker system before thoracoscopic resection. MATERIAL AND METHODS: In 24 patients (15 M, 9 F; age range, 18-71 years) a total of 25 pulmonary nodules (in 1 patient 2 lesions simultaneously) were marked with a special wire under CT-guidance and then thoracoscopically resected. We evaluated lesion size, lesion distance to the pleura, the time of intervention, complications, and thoracoscopic success rate. RESULTS: Mean lesion size was 7 mm (range 4-15 mm) and mean lesional distance to the pleura was 13 mm (range 2-31 mm). The pulmonary nodule-marker system was positioned successfully in all 25 pulmonary nodules within 5-11 min (mean 7.5 min). Minimal pneumothoraces were observed in five patients with no requirements of chest drains. In addition, no bleeding complications or hematothorax were observed. All 25 pulmonary nodules could be resected thoracoscopically. However, in one patient (4%), the guide-wire dislocated during thoracoscopy, but the lesion could be successfully resected during thoracoscopy. CONCLUSION: The CT-guided placement of the pulmonary nodule-marker system used here offers a safe and accurate guide for the localization of small pulmonary nodules during thoracoscopic resection.

Adolescent↗

Lung nodule conspicuity using unsharp mask filters with storage-phosphor-based computed radiography.

PURPOSE: To compare the performance of various types of unsharp mask filter applied in storage-phosphor-based computed radiography (SR), and to improve the detection of faint nodules of the lung cancer type. MATERIAL AND METHODS: A total of 120 SR radiographs were obtained by means of an anthropomorphous chest phantom and a combination of 3 types of small simulated nodule (5-mm sphere-shaped, and 5-mm and 10-mm hemisphere-shaped) placed on the phantom's surface. Eight combinations of nodule site were selected from 16 predetermined chosen sites, and 5 types of parameter were used for unsharp mask filtering. Eight observers evaluated the images, and the detectability of the lung nodules was evaluated from the images by a ROC analysis. RESULTS: The visibility of the 10-mm hemispherical nodules was nearly equivalent at each site when 5 types of unsharp mask filter were used. The detection of the 5-mm nodules with mid-frequency suppressing and very-low-frequency enhancing filters was better than with a conventional (department standard) mid-frequency enhancing filter. CONCLUSION: Mid-frequency suppressing versions of the filter helped to demonstrate faint nodular opacity, which is often shown by early bronchogenic carcinoma. This filter could replace conventional filters in the detection of lung nodules.

Carcinoma, Bronchogenic↗

Thyroid nodule shape and prediction of malignancy.

BACKGROUND: Thyroid nodules are common; the vast majority benign. Preoperative determination of malignancy remains imprecise, despite fine-needle aspiration (FNA). Numerous risk factors have been proposed for predicting malignancy, though few have been found useful. Oxygen delivery is a crucial component for tumor cell growth. It has been hypothesized that malignant tumors may configure their shape to maximize access to local nutrient delivery. Mathematically, surface area to volume is maximized by a spherical shape. We sought to determine if spherical shape is a predictor of malignancy. METHODS: Seven hundred forty-seven consecutive patients underwent ultrasound evaluation and FNA of 993 solid thyroid nodules (< 25% cystic) between 1995 and 2000 and were retrospectively analyzed. Nodules were classified as benign or malignant based on FNA and/or surgical pathology. Spherical shape was estimated by calculating a ratio of the longest to shortest dimensions, and rate of malignancy correlated. RESULTS: Spherical shape was independently correlated with risk of malignancy (p < 0.001). Thyroid cancer was detected in 11% of all nodules, but ranged from 18% in spherical nodules to 5% in those least spherical. Nodules found to have suspicious or intermediate cytology showed similar variation in malignant risk. A long to short axis ratio greater than 2.5 was 100% predictive of a benign process, although present in only 4% of our cohort. A prospective validation was performed and confirmed consistent results (p < 0.01). CONCLUSION: Spherical shape is associated with an increased rate of malignancy in solid thyroid nodules. Determination of shape may assist in clinical risk assessment of thyroid cancer.

Adult↗

The trapping-only nodules of the thyroid gland: prevalence study.

The aim of this study was to determine the prevalence of trapping-only nodules of the thyroid gland. The study was prospectively performed in patients bearing hot or warm thyroid nodules at pertechnetate scan in the presence of circulating thyrotropin (TSH) within the normal range. The study was restricted to these patients because nodules that suppress TSH are certainly autonomous. In 140 patients showing hot or warm nodules at 30-minute pertechnetate scintigraphy, and normal TSH levels, radioiodine scintigraphy was performed at 24 hours. The trapping-only pattern, i.e., the presence of a cold nodule in late radioiodine scintigraphy was observed in seven patients (5%). Five had benign thyroid nodules, one follicular carcinoma, and one extrathyroid metastases of papillary-follicular carcinoma. Despite controversy on this issue, trapping-only nodules of thyroid should be searched because they have risk of malignancy and must be differentiated from autonomous adenomas at the compensated stage. The search may be limited to patients with normal serum TSH.

Adenocarcinoma, Follicular↗

Injection therapy of superficial rheumatoid nodules.

Although intralesional corticosteroid injection of subcutaneous rheumatoid nodules was mentioned in 1968, this simple procedure is not commonly practised. A placebo-controlled, double-blind trial of intralesional corticosteroid injection using 24 rheumatoid nodules from 11 patients was carried out to determine the efficacy and safety of the procedure. Nodules injected with methylprednisolone and lignocaine regressed significantly more than nodules injected with placebo (lignocaine alone). This was consistently shown in all modalities of assessments which included patients' assessments (P < 0.001) and investigator's assessments (P < 0.001) of the percentage change in nodule size, and gross measurements of nodule volumes using a pincer (P < 0.001). Nine of 12 active injections produced > or = 50% loss in nodular volume with complete disappearance of two nodules. This compares with only one out of 12 placebo injections which resulted in > or = 50% loss in nodular volume. The patients found all 12 active injections to be worthwhile compared to only two of 12 placebo injections being worthwhile. The only complication of injection therapy observed was that of pain during the procedure.

Adrenal Cortex Hormones↗

Differentiation of benign from malignant nodules by accumulation of Tc-99m pertechnetate using TI-201 delayed scans.

Thyroid carcinoma usually is characterized by a nonfunctioning or "cold" nodule depicted on the Tc-99m scan. Twelve patients with functioning "hot" thyroid nodules underwent thyroidectomy (nine hemithyroidectomies, two nodulectomies, and one subtotal thyroidectomy). Histologic examination revealed that five patients (42%) had malignant nodules (papillary carcinoma in two and follicular carcinoma in three). Of the seven patients with benign nodules, five had follicular adenoma and two had adenomatous hyperplasia. TI-201 scanning (early and delayed) was performed at the same time as Tc-99m scanning. Only one of the seven benign nodules showed accumulation on the delayed TI-201 scan, whereas all five malignant nodules showed accumulation. The delayed TI-201 scan is useful for the differentiation of benign from malignant nodules that show accumulation of Tc-99m pertechnetate.

Diagnosis, Differential↗

Flat panel detector-based volumetric CT: prototype evaluation with volumetry of small artificial nodules in a pulmonary phantom.

PURPOSE: To evaluate amorphous silicone-based flat panel detector volumetric CT (VCT) in volumetric assessment of small nodules in a pulmonary phantom, and to perform comparative experiments with 4-row multislice CT (MSCT). MATERIALS AND METHODS: Seventy synthetic nodules (volume range (VR): 0.99-185.77 mm; estimated diameter range (ED): 1.4-7.8 mm) were scanned in spherical shape and after iso-volumetric deformation with VCT and MSCT using 0.63 mm (MSCT I) and 1.25 mm (MSCT II) collimations. Measured volumes and percent measurement errors (PME) were compared between the 3 CT modes before and after nodule deformation. For each measurement pair before and after deformation, the post-deformation relative volumetric inaccuracy (RIA) was determined. Volume, PME, and RIA differences were tested using Wilcoxon and Friedman methods. RESULTS: The volumes of the smallest nodules (VR = 0.99-2.83 mm, ED = 1.4-1.9 mm) were computable only from VCT scans. In VCT, measured volumes and PMEs before and after deformation differed significantly less compared with MSCT (VCT: P = 0.06 and 0.56, respectively; MSCT I: P = 0.0012 and 0.006, respectively; and MSCT II: P < 0.0001 for measured volumes and PMEs). In VCT PMEs of 5.51-32.21 mm nodules (ED = 2.4-4.1 mm) before and after deformation were significantly below MSCT (VCT averages = 1.43-1.91% and 1.98-3.48%, for spherical and deformed nodules, respectively; MSCT I averages = 9.97-26.1% and 12.16-38.10%, respectively; MSCT II averages = 17.79-46.18 and 18.14-54.66%, respectively, P < 0.0001) and RIAs in VCT were significantly below MSCT (VCT: 0.50-2.62%, MSCT I: 3.35-15.97%, and MSCT II: 4.29-18.46%; P = 0.0001-0.0039). CONCLUSION: VCT volumetry is highly accurate in volumetry of smallest nodules with estimated diameters of 1.4-4.1 mm.

Humans↗

Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images.

Small pulmonary nodules are a common radiographic finding that presents an important diagnostic challenge in contemporary medicine. While pulmonary nodules are the major radiographic indicator of lung cancer, they may also be signs of a variety of benign conditions. Measurement of nodule growth rate over time has been shown to be the most promising tool in distinguishing malignant from nonmalignant pulmonary nodules. In this paper, we describe three-dimensional (3-D) methods for the segmentation, analysis, and characterization of small pulmonary nodules imaged using computed tomography (CT). Methods for the isotropic resampling of anisotropic CT data are discussed. 3-D intensity and morphology-based segmentation algorithms are discussed for several classes of nodules. New models and methods for volumetric growth characterization based on longitudinal CT studies are developed. The results of segmentation and growth characterization methods based on in vivo studies are described. The methods presented are promising in their ability to distinguish malignant from nonmalignant pulmonary nodules and represent the first such system in clinical use.

Algorithms↗

Suppressive therapy with levothyroxine for solitary thyroid nodules.

OBJECTIVE: To evaluate the effect of treatment with TSH suppressive dose of levothyroxine in patients with benign thyroid nodules. DESIGN: Prospective randomized study. Group A (n = 20) patients received levothyroxine and group B (n = 20) patients did not. The dose of levothyroxine was adjusted to obtain an effective suppression of TSH. A clinical, analytical and morphological (with ultrasound) review was performed every 3 months. The mean +/- SD follow-up period was 10.6 +/- 2.2 months. PATIENTS: Forty euthyroid women with solitary thyroid nodule on palpation, cold on scintigraphy and cytologically benign without contraindication participated. MEASUREMENTS: At entry: biochemical and hormonal parameters, thyroid scintigraphy and thyroid ultrasonography. Every 3 months additional determinations of thyroid hormones and TSH levels were carried out, if necessary, to verify effective TSH suppression. Every 6 months thyroid ultrasound imaging was performed. RESULTS: Patients were euthyroid at entry into the study. The mean dose of levothyroxine necessary to obtain TSH suppression was 2.82 +/- 0.6 micrograms/kg/day. No significant modification in the thyroid nodule diameter (mean +/- SD 2.6 +/- 1.2 vs 2.5 +/- 1.2 cm) or in the thyroid nodule volume (10.3 +/- 11.9 vs 10.1 +/- 12.2 ml) were observed in group A. In group B the results were similar (2.8 +/- 0.9 vs 2.7 +/- 1.8 cm and 9.2 +/- 6.4 vs 9.2 +/- 9.5 ml, respectively). No differences were found in either group in the number of nodules that reduced significantly their volume (four and three, respectively). CONCLUSIONS: The suppressive therapy with levothyroxine was not effective in reducing nodule sizes in patients with solitary benign thyroid nodules.

Adult↗

Rheumatoid arthritis with diffuse pulmonary rheumatoid nodules.

Rheumatoid nodules in dermal or subcutaneous tissues, while indicative of rheumatoid arthritis, are very rare. It is even less common to identify these rheumatoid nodules by biopsy as well as in autopsy materials from lung tissue. These nodules may be single or multiple, which seldom cause respiratory symptoms. Here, a patient with diffuse pulmonary rheumatoid nodules and interstitial fibrosis throughout both lungs, is described. The patient, with articular symptoms and seropositivity, exhibited a rapid clinical course and died of respiratory failure 3 months after the appearance of dyspnea. Chest radiography indicated interstitial pneumonitis with bilateral diffuse peripheral shadows. At autopsy, numerous rheumatoid nodules and interstitial fibrosis had destroyed both lungs, such that no residual normal pulmonary tissue remained. It is believed that this was an extremely rare case exhibiting large numbers of rheumatoid nodules throughout the lungs. Findings with this patient indicate that, in patients with rheumatoid arthritis, clinical interstitial pneumonitis confirmed radiologically does not exclude the existence of rheumatoid lung nodules.

Arthritis, Rheumatoid↗

Are rheumatoid nodules caused by vasculitis? A study of 13 early cases.

Rheumatoid nodules are especially found in patients with seropositive rheumatoid arthritis (RA). It is often suggested that the genesis of these lesions is due to a vasculitis in smaller capillary vessels or venules. To test this hypothesis we studied fresh nodules in 13 patients, all with classical or definite RA. In 7 cases a total of 8 nodules were removed within 10 days of origin and in 6 other cases between 2 and 8 weeks. In the former group immunofluorescence was found in 5 out of 8 cases, and in the latter group 3 out of 6 were positive. Immunoglobulin deposition together with complement was found only in cases of 10 days' duration or less. No correlation was found with the patient's age or disease duration, ESR, ANA positivity, Rose titre, haemoglobulin, or use of prednisolone. In 3 out of 7 nodules younger than 7 days no palisade layer was found, whereas in older nodules this layer was always present. Vasculitis was not more frequently present in the cases with younger nodules. Our study does not support the hypothesis that vasculitis is the primary cause of nodules.

Aged↗

Role of Tc-99m MIBI in the evaluation of single pulmonary nodules: a preliminary report.

BACKGROUND: Survival in bronchial carcinoma is closely related to the stage of the disease at the time of diagnosis and a single pulmonary nodule represents a potentially curable stage. This study was conducted to assess the feasibility of using Tc-99m labelled 2-methoxy isobutyl isonitrile (MIBI) to differentiate benign from malignant single pulmonary nodules. METHODS: A prospective study was conducted in the outpatient pulmonary clinic at the Cleveland Clinic Foundation. Twenty five patients with single pulmonary nodules considered indeterminate by their physicians and undergoing a procedure for tissue diagnosis were evaluated by Tc-99m MIBI SPECT scanning prior to definitive testing. Assessment of MIBI uptake was done qualitatively (subjectively) and quantitatively and correlated with the histopathology and nodule size. RESULTS: Of the 21 patients with malignant lesions, 18 had increased uptake of MIBI corresponding to the location of the nodule and were considered positive. The predominant tumour types were large cell (n = 5) and adenocarcinoma (n = 10). All four patients with benign lesions had negative MIBI scans. For malignancy the overall specificity was 100%, sensitivity was 85.7%, positive predictive value was 100%, and negative predictive value was 57%. Quantitative uptake of MIBI correlated with the diameter of the nodule with a correlation coefficient of 0.61 by Spearman's rank sum test. This relationship was statistically significant (p = 0.02). CONCLUSION: This preliminary study suggests that Tc-99m MIBI has a very high specificity and positive predictive value for malignant single pulmonary nodules and might be a useful non-invasive diagnostic modality in their management.

Aged↗

Pulmonary nodules at chest CT: effect of computer-aided diagnosis on radiologists' detection performance.

PURPOSE: To evaluate the effect of computer-aided diagnosis (CAD) on radiologists' detection of pulmonary nodules. MATERIALS AND METHODS: Fifty chest computed tomographic (CT) examination cases were used. The mean nodule size was 0.81 cm +/- 0.60 (SD) (range, 0.3-2.9 cm). Alternative free-response receiver operating characteristic (ROC) analysis with a continuous rating scale was used to compare the observers' performance in detecting nodules with and without use of CAD. Five board-certified radiologists and five radiology residents participated in an observer performance study. First they were asked to rate the probability of nodule presence without using CAD; then they were asked to rate the probability of nodule presence by using CAD. RESULTS: For all radiologists, the mean areas under the best-fit alternative free-response ROC curves (Az) without and with CAD were 0.64 +/- 0.08 and 0.67 +/- 0.09, respectively, indicating a significant difference (P <.01). For the five board-certified radiologists, the mean Az values without and with CAD were 0.63 +/- 0.08 and 0.66 +/- 0.09, respectively, indicating a significant difference (P <.01). For the five resident radiologists, the mean Az values without and with CAD were 0.66 +/- 0.04 and 0.68 +/- 0.04, respectively, indicating a significant difference (P =.02). At observer performance analyses, there were no significant differences in Az values obtained either without (P =.61) or with (P =.88) CAD between the board-certified radiologists and the residents. For all radiologists, in the detection of pulmonary nodules 1.0 cm in diameter or smaller, the mean Az values without and with CAD were 0.60 +/- 0.11 and 0.64 +/- 0.11, respectively, indicating a significant difference (P <.01). CONCLUSION: Use of the CAD system improved the board-certified radiologists' and residents' detection of pulmonary nodules at chest CT.

Adult↗

Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society.

Lung nodules are detected very commonly on computed tomographic (CT) scans of the chest, and the ability to detect very small nodules improves with each new generation of CT scanner. In reported studies, up to 51% of smokers aged 50 years or older have pulmonary nodules on CT scans. However, the existing guidelines for follow-up and management of noncalcified nodules detected on nonscreening CT scans were developed before widespread use of multi-detector row CT and still indicate that every indeterminate nodule should be followed with serial CT for a minimum of 2 years. This policy, which requires large numbers of studies to be performed at considerable expense and with substantial radiation exposure for the affected population, has not proved to be beneficial or cost-effective. During the past 5 years, new information regarding prevalence, biologic characteristics, and growth rates of small lung cancers has become available; thus, the authors believe that the time-honored requirement to follow every small indeterminate nodule with serial CT should be revised. In this statement, which has been approved by the Fleischner Society, the pertinent data are reviewed, the authors' conclusions are summarized, and new guidelines are proposed for follow-up and management of small pulmonary nodules detected on CT scans.

Diagnosis, Differential↗

Solitary pulmonary nodule: high-resolution CT and radiologic-pathologic correlation.

Edge and internal characteristics of pulmonary nodules evaluated with high-resolution computed tomography (HRCT) were correlated with the pathologic specimens in 93 patients. Speculation correlated pathologically with irregular fibrosis, localized lymphatic spread of tumor, or an infiltrative tumor growth pattern and was observed in six of 11 benign nodules (55%) and 74 of 85 malignant nodules (87%). Pleural tags were observed in three benign nodules (27%) and 49 malignant lesions (58%); pathologically, these represented fibrotic bands usually associated with juxta-cicatricial pleural retraction. Bubblelike areas of low attenuation within the nodule were observed in 21 malignant lesions (25%) and only one benign nodule (9%). They were observed most commonly in bronchioloalveolar carcinomas (seven of 14) and were due either to patent small bronchi or small, cystic spaces within neoplastic glands. Malignant nodules as a group were larger than benign lesions (P = .02) and more commonly demonstrated a spiculated contour (P less than .05), lobulation (P less than .001), and inhomogeneous attenuation (P less than .05).

Adult↗

Solitary pulmonary nodule: CT evaluation of enhancement with iodinated contrast material--a preliminary report.

The authors hypothesized that the degree of contrast material enhancement of a pulmonary nodule, measured with computed tomography (CT), may indicate the likelihood of malignancy. Fifty-two patients with uncalcified solitary pulmonary nodules (diameter, 6-30 mm) were studied. Five single serial thin-section CT scans were obtained at 1-minute intervals after injection of 100 mL of nonionic contrast material. Twenty-two patients were excluded because the diagnosis was not clearly established: The observation period was less than 2 years, or the examination was technically inadequate. Malignant nodules were identified in 23 of the 30 remaining patients, and benign nodules were identified in seven. Within the first 2 minutes after the injection, all the malignant nodules had enhanced by 20 HU or greater (only one benign nodule had that degree of enhancement). The authors conclude that the degree of contrast material enhancement of pulmonary nodules as measured with CT may indicate the likelihood of malignancy.

Adult↗

Thyroid nodules associated with Hashimoto thyroiditis: assessment with US.

Sonographic findings in 109 thyroid nodules in 104 patients with Hashimoto thyroiditis were retrospectively analyzed. Sixty patients underwent ultrasound (US)--guided fine-needle aspiration (FNA) biopsy (65 nodules, 24 palpable, 27 surgically confirmed), 14 of whom also underwent palpation-guided FNA (14 nodules, all palpable, all surgically confirmed). Forty-four patients (44 nodules, 25 palpable) underwent diagnostic US followed up with surgery. US-guided FNA helped differentiate between benign (n = 11) and malignant (n = 16) diseases (sensitivity, 100%). Two papillary carcinomas were falsely diagnosed as Hashimoto thyroiditis with palpation-guided FNA. Eight malignancies were not palpable, and correct diagnosis was obtained with US-guided FNA. Hyperechoic nodules were usually benign, and isoechoic nodules had a low frequency (13%) of malignancy. Most carcinomas were found in hypoechoic masses, and almost all lymphomas were found in markedly hypoechoic masses. Lymphoma was indistinguishable from pseudotumor in Hashimoto thyroiditis or adenomatous hyperplasia at US. US-guided FNA is helpful in making the histologic diagnosis in thyroid nodules associated with Hashimoto thyroiditis. US-guided FNA is clinically beneficial because it can help select patients who need surgery, avoiding unnecessary surgery for patients with nonneoplastic disorders.

Adenoma↗

Pulmonary nodules: detection with thick-section spiral CT versus conventional CT.

Spiral volumetric computed tomography (CT) with single breath-hold technique was compared with conventional sequential CT in 39 patients. The spiral CT protocol consisted of a 10 mm/sec table feed during a 24-second breath hold at 145 mA, with reconstruction of images at 10-mm intervals; one (n = 21) or two (n = 18) sequences were necessary to screen the complete lung. Conventional CT was performed with a 1-second scan time, 145 mA, and contiguous 10-mm-thick sections. In the 39 patients studied with each technique, no lung nodule was detected in three, two had a single nodule, and 29 had multiple nodules. Two patients with normal findings at chest radiography and three with a solitary pulmonary nodule at conventional CT had multiple nodules at spiral CT. Mean number of nodules per patient was significantly higher with spiral versus conventional CT (18 +/- 4.5 vs 12.6 +/- 3.2 [mean +/- standard error of the mean], P = .01) as were the number of nodules less than 5 mm in diameter per patient (12.7 +/- 3.7 vs 8.4 +/- 2.3, P < .05) and 5-10 mm in diameter (2.9 +/- 0.9 vs 2.4 +/- 0.8, P < .05). Respiratory motion artifacts were never observed with spiral CT although they were present on four conventional CT scans.

Adolescent↗