[Fracture of the medial femoral condyle as a complication of retrograde femoral nail removal].

A 26-year-old female patient with a femoral shaft fracture underwent retrograde femoral nailing. Nail removal was performed 2 years later, after fracture healing. An intraoperative fracture of the medial condyle of the femur occurred. This complication has not been previously described in the literature. Screw osteosynthesis of the fracture was performed and articular congruence reestablished. After 6 weeks of fractional weight bearing, the patient proceeded up to full weight bearing without complication. The case demonstrates that the removal of retrograde femoral nails is not without complications. The decision to undertake implant removal should be made carefully.

Adult↗

Difficulties in removing ACE tibial intramedullary nail.

We experienced three cases of refracture and two cases of failure to remove the nail while trying to take out ACE tibial nails from healed tibial fractures. In order to determine the risk factors associated with difficulties in nail removal, these five patients were compared in the parameters of age, gender, duration of nail in situ, nail diameter, nail length, and level of fracture with 30 patients who had uneventful removal. Younger age of the patient was significantly associated with the difficulty in nail removal.

Adolescent↗

Elective removal of cuffed central venous catheters in children.

BACKGROUND: Subcutaneously tunneled, cuffed central venous catheters (CVCs) are commonly used in children undergoing cytotoxic chemotherapy or hematopoietic stem-cell transplantation. When their use is no longer indicated or precluded by mechanical or infectious complications, CVCs have to be removed. General instructions on how cuffed CVC should be removed are available in the medical texts but none is adapted for use in children. MATERIALS AND METHODS: A literature search from the MEDLINE and EMBASE to identify articles describing the procedure of removing CVC or complications arising from the procedure was carried out. RESULTS: Specific guidance on the removal of CVC in children was not found. Venous air embolism appeared to be the most common complication associated with catheter removal but none involved pediatric patients. On the other hand, three out of the five incidents of catheter fracture with or without embolization happened in children. CONCLUSION: Further studies are needed to define the optimal management of CVC removal in pediatric patients. A sequence of positioning the child, use of sedation, dissecting out the cuff, pulling off the catheter, closing the exit wound, and handling of the removed catheter is suggested.

Catheterization, Central Venous↗

Technique for removal of symptomatic bone anchors placed during stress incontinence surgery.

INTRODUCTION: To present an uncomplicated, reliable technique for bone anchor removal in patients with anchor-related infections or chronic pain. TECHNICAL CONSIDERATIONS: We removed 17 anchors from 9 patients between 1999 and 2004. The surgical technique used fluoroscopy for localization of the anchors and an orthopedic broken screw removal instrument for resection of the anchor and surrounding bone. Nine patients with bone anchors had been symptomatic with chronic pain and/or wound drainage for a mean of 23.7 months before surgery. After removal, 10 anchors grew positive bacterial cultures. The most common organism was coagulase-negative Staphylococcus. During a mean follow-up period of 6.8 months after hardware removal, 8 of the 9 patients had symptomatic improvement. CONCLUSIONS: Fluoroscopic localization and en bloc resection with a broken screw removal instrument is an effective method of removing symptomatic bone anchors.

Adult↗

Case report: further upward migration of a misplaced double-J ureteral stent.

A 45-year-old man was referred to our hospital for the removal of a misplaced double-J ureteral stent. The lower end of the stent shortly after insertion was at the level of sacroiliac joint. However one week later the stent was further migrated upwards to the level of 4th lumbar vertebra. Immediate ureterorenoscopy was performed to prevent further migration of the stent to the renal pelvis and the stent was removed by the grasping forceps under direct vision successfully.

Device Removal↗

[Migration of Kirschner wires after surgical stabilization of injuries in the area of the shoulder--4 case reports].

Internal fixation is recommended for displaced and unstable fractures of the lateral clavicle and fractures involving the proximal humerus. Kirschner wires, although recommended in the orthopedic literature bear the risk of wire breakage and migration. 4 cases with serious and potentially hazardous complications are presented. All reported complications occurred years after the operative treatment without clinical symptoms. Regular postoperative follow-ups and early hardware removal after fracture healing is recommended.

Adult↗

Extraction of pacemaker and implantable cardioverter defibrillator leads: patient and lead characteristics in relation to the requirement of extraction tools.

Effective tools for extraction of pacemaker and ICD leads have been developed in the past decennium. This study investigated the necessity of using these tools in addition to direct traction in relation to patient and lead characteristics. The study encompasses first attempts at extraction of consecutive pacemaker and ICD leads from the subpectoral area. A stepwise extraction protocol was used with traction first (directly or with a locking stylet) followed by laser sheath extraction if not successful. The indication, patient age, time from implant, fixation mechanism, location, and insertion site of the leads were studied in relation to the outcome of traction. A total of 145 leads in 83 patients were extracted. Leads were implanted for 71 +/- 61 months. Indication for extraction was infection in 96 leads and malfunction in 49 leads. There were 90 ventricular leads including 16 ICD leads. Forty-nine (34%) leads were extracted with traction; in 96 (66%) leads a laser sheath was necessary. All leads implanted for < 6 months could be removed with traction alone. In a multivariate logistic regression model, time from implant was the main factor determining success of traction (P < 0.001), but in case of infection the success rate increased (P = 0.004). In conclusion, time from implant is the decisive factor to judge the potential efficacy of lead extraction with direct traction. If leads are implanted for 6 months, the availability of additional extraction tools is necessary when lead extraction is considered. In addition to time from implant, infected leads have a better chance to be removed with traction although it is a much weaker predictor.

Defibrillators, Implantable↗

Component removal in revision total hip arthroplasty.

Component removal is a time-consuming yet necessary step during revision hip surgeries. Because of the diversity of the components and the methods used to secure them, an equal diversity of approaches and tools are necessary for component removal. Careful and detailed preoperative planning is mandatory, the mode of failure must be understood, and detailed imaging should be available to the surgeon. Understanding the basic principles and indications for each of the techniques would optimize outcome. We review the approaches, tools, and techniques for component removal in revision hip procedures in stepwise sequence.

Acetabulum↗

Technical report: use of ultrasound guidance in the removal of tunnelled venous access catheter cuffs.

Venous access catheters are employed for a wide variety of reasons. On removal of the catheter, the subcutaneous catheter cuff can be difficult to extract; retention of the cuff has recognized complications. We describe a simple ultrasound technique that assists in the identification of the cuff within the subcutaneous tissues, simplifying subsequent cuff removal. This may lead to a reduction in associated complications.

Catheters, Indwelling↗

The removal of fractured post fragments in general dental practice using ultrasonic vibration.

This paper describes an evidence-based clinical procedure that is suitable for the removal of fractured metal post fragments using ultrasonic vibration in general dental practice, particularly when non-resin-based cements have been used. Fragments of posts cemented with resin-based cements are likely to be extremely difficult to remove. The use of non-resin-based cements is recommended for luting posts, as fragment or total post removal is much easier with these materials.

Crowns↗

[The realization of a wear-timing device for clarifying the scientific questions presented in orthodontics].

A timing device for removable orthodontic appliances is described. The measurement system includes a quartz digital clock at the timer. A reed switch serves as a sensor and is activated by a magnetic device fastened directly or by an orthodontic band to a molar tooth. A changeover reedswitch prevents manipulation by the patient. As a timing device the system provides great accuracy. The high-speed capability of the device permits further scientific application: Installation of two timing devices in a single Bionator permits selective timing (e.g. biting contact during wear of the appliance).

Activator Appliances↗

One stage side-to-side replacement of infected pulse generators and leads.

Infected and contaminated cardiac pulse generators and leads must be removed entirely in order to effect a cure. We have shown through our experience with 68 consecutive cases that explantation of the offending system and replacement of a new device on the opposite side can be safely accomplished in one sitting--a side-to-side replacement--as long as there is appropriate case selection. There were no early or late infections of the new operative site.

Adult↗

Keratitis after intracorneal ring segment insertion for keratoconus.

We report a case of sterile keratitis after Ferrara intracorneal ring (Ferrara Ophthalmics) implantation into the right cornea of a keratoconus patient who also suffered from atopic blepharoconjunctivitis. The keratitis resolved within a few days after removal of the Ferrara rings. Ocular atopy with sterile keratitis should be considered in the differential diagnosis of keratitis after the insertion of intracorneal ring segments, which can be easily treated by ring removal.

Adult↗