PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Mechanical properties of 2 new addition-vulcanizing silicone prosthetic elastomers.

PURPOSE: This study evaluated some mechanical properties of 2 newly introduced, addition-type silicone prosthetic elastomers (Cosmesil and Episil). MATERIALS AND METHODS: The properties evaluated were tensile strength, modulus at 100% elongation, elongation at break, tear strength, and hardness. The properties tested were selected because of their clinical significance for fabricating facial prostheses. RESULTS: Episil showed greater tensile strength (P = 0.0002), elastic modulus (P = 0.0001), hardness (P = 0.0002), and tear strength (P = 0.0004) than Cosmesil material. Cosmesil exhibited a higher elongation at break (P = 0.0002) than Episil. CONCLUSION: Cosmesil and Episil showed reasonable properties as facial prosthetic elastomers and neither was superior for all properties tested. Both materials showed favorable combinations of elongation at break and tear strength.

Elasticity↗

Calcium buffering is required to maintain bone stiffness in saline solution.

This work determined whether mineral dissolution due to prolonged testing or storage of bone specimens in normal saline would alter their elastic modulus. In one experiment, small pieces of equine third metacarpal bone were soaked in normal saline supplemented with varying amounts of CaCl2. Changing Ca ion concentrations in the bath were monitored and the equilibrium concentration was determined. In a second experiment, the elastic moduli of twenty 4 x 10 x 100 mm equine third metacarpal beams were determined non-destructively in four-point bending. Half the beams were then soaked for 10 days in normal saline, and the other half in saline buffered to the bone mineral equilibrium point with Ca ions. Modulus measurements were repeated at 6 and 10 days. The equilibrium Ca ion concentration for bone specimens was found to be 57.5 mg l-1. The modulus of bone specimens soaked in normal saline significantly diminished 2.4%, whereas the modulus of those soaked in calcium-buffered saline did not change significantly.

Animals↗

Characterisation of some experimental silicones.

Release of antimicrobials/antibacterials like chlorhexidine diacetate (CHD) has proved successful in inhibiting Candidal colonisation of silicone-based biomaterials. However, their addition will increase water uptake and may compromise the mechanical integrity. Two experimental silicones (S1 and S2) differing only in the surface treatment of the filler, were investigated. Ultimate tensile strength (UTS), % elongation at break (Eb), Shore A hardness and, when doped with 1% CHD, water uptake and CHD release were measured. Elastic modulus (E) was calculated from the hardness measurements. There was no significant difference in UTS and Eb between the two materials. However S1 had a higher hardness (30.6 +/- 0.97) and thus E (0.76 MPa) than S2 (hardness = 23.8 +/- 0.48, E = 0.45 MPa). Water uptake for S2 (0.6%) was higher than for S2 (0.1) and addition of CHD dramatically increased the uptake of both (S1 = 3.1%, S2 = 4.0%). Release of CHD was higher for S2 (30%) than S1 (27%). Equating osmotic pressure within the droplets with elastic restraining force gave an extension ratio of 1.95 for S1 and 5.39 for S2. Thus, addition of a hydrophilic agent can compromise the mechanical integrity of low modulus silicones.

Biocompatible Materials↗

Processing and tensile properties of hydroxyapatite-whisker-reinforced polyetheretherketone.

Polyetheretherketone (PEEK) was reinforced with 0-50 vol% hydroxyapatite (HA) whiskers using a novel powder processing and compression molding technique which enabled uniform mixing at high whisker content. Texture analysis showed that viscous flow during compression molding produced a preferred orientation of whiskers along the specimen tensile axis. Consequently, the elastic modulus or ultimate tensile strength of HA-whisker-reinforced PEEK was able to be tailored to mimic human cortical bone. PEEK reinforced with 40 and 50 vol% HA whiskers exhibited elastic moduli of 17 and 23 GPa, respectively. Elastic constants were measured using ultrasonic wave propagation and revealed an orthotropic anisotropy also similar to that measured in human cortical bone. PEEK reinforced with 10 and 20 vol% HA whiskers exhibited an ultimate tensile strength of 90 and 75 MPa, respectively. Tensile specimen fracture surfaces showed evidence of brittle failure in both reinforced and un-reinforced PEEK. Whisker pullout was observed with PEEK adhered to HA whiskers, suggesting a relatively strong interface between the PEEK matrix and HA whisker reinforcements.

Benzophenones↗

Detection of lumen-intima interface of posterior wall for measurement of elasticity of the human carotid artery.

In our series of studies on noninvasive assessment of the regional elasticity of the arterial wall, the displacement gradient (change in thickness) of the arterial wall caused by the heartbeat was measured by the phased-tracking method. Because the displacement gradient corresponds to the strain due to the change in blood pressure, the elasticity can be evaluated from the displacement gradient of the arterial wall and the blood pressure, which are noninvasively measured at the upper arm. In the measurement of the elasticity of the arterial wall by our method, the region in which the elastic modulus is estimated must be assigned beforehand; currently, the lumen-intima boundary of the arterial wall is manually determined by the operator. For the real-time measurement of the elasticity of the arterial wall, a fast, automated method is necessary for detection of the boundary. In this paper, a cost function is proposed for differentiation of the arterial wall from the lumen. The proposed cost function was applied to ultrasound data, which were noninvasively obtained for five human carotid arteries. In comparison with the case of detection using only the amplitude of the echo, the root mean square error between the automatically detected lumen-intima boundary and the manually assigned boundary was significantly improved by using the proposed cost function. Furthermore, the lumen-intima boundary was automatically detected in a short period. Such a method is required for real-time measurement of the elasticity of the arterial wall, though detection of the outer boundary of the adventitia, which is not described in this paper, is also necessary to realize real-time elasticity measurement by our method.

Adult↗

Tensile strength and dilatational elasticity of giant sarcolemmal vesicles shed from rabbit muscle.

1. Mechanical properties of the surface membrane of skeletal muscle were determined on sarcolemmal vesicles (mean diameter, 71 microns) shed by rabbit psoas muscle swelling in 140 mM KC1 containing collagenase. 2. Vesicles were stressed by partial aspiration into parallel bore pipettes. The isotropic membrane tension so created caused an increase in membrane area which expresses itself in an elongation of the vesicle projection into the pipette. 3. For individual vesicles, a linear relationship between membrane tension and membrane area increase was found up to the point when the vesicle burst, i.e. sarcolemmal vesicles behaved as perfectly elastic structures. 4. The maximum tension sarcolemmal vesicles could sustain before bursting was 12.4 +/- 0.2 mN m-1 (median +/- 95% confidence interval), and the corresponding fractional increase in membrane area was 0.026 +/- 0.005 (median +/- 95% confidence interval). The elastic modulus of area expansion was 490 +/- 88 mN m-1 (mean +/- S.D.). 5. In conformity with cited comparable work on red blood cells and artificial lipid vesicles, the strength and area elasticity of the skeletal muscle membrane are considered properties of the fluid lipid matrix of the membrane and of the degree to which the bilayer is perturbed by lipid-protein interaction.

Animals↗

Effect of nondialyzable solids concentration and viscoelasticity on ciliary transport of tracheal mucus.

The viscoelastic properties of reconstituted canine tracheal mucus were correlated with the ciliary transport rate measured on the bullfrog palate. A maximum in mucociliary transport rate was found at an optimal concentration of nondialyzable solids of 1.5 to 2 per cent. At concentrations less than this value, the mucus had little or no elasticity and low rates of transport; at concentrations greater than the optimum, however, further increases in elastic modulus also resulted in decreasing transport.

Animals↗

Ultrasonic strain imaging and reconstructive elastography for biological tissue.

Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allow an inverse elastography approach leading to the spatial distribution of the relative elastic modulus of tissue. The internal displacement field of biological tissue is determined using the above mentioned strain imaging system by applying quasi-static compression to the considered tissue. Axial displacements are calculated by comparing echo signal sets obtained prior to and immediately following less than 0.1% compression, using the fast root seeking technique. Strain images representing mechanical tissue properties in a non-quantitative manner are displayed in real-time mode. For additional quantitative imaging, the stiffness distribution is calculated from the displacement field assuming the investigated material to be elastic, isotropic, and nearly incompressible. Different inverse problem approaches for calculating the shear modulus distribution using the internal displacement field have been implemented and compared. The results of an ongoing clinical study with more than 200 patients show, that our real-time strain imaging system is able to differentiate malignant and benign tissue areas in the prostate with a high degree of accuracy (sensitivity=76% and specificity=89%). The reconstruction approaches applied to the strain image data deliver quantitative tissue information and seem promising for an additional differential diagnosis of lesions in biological tissue. Our real-time system has the potential of improving diagnosis of prostate and breast cancer.

Algorithms↗

Constitutive models for impacted morsellised cortico-cancellous bone.

Constitutive models are developed, based on the results of confined compression testing, to describe the visco-elastic, and non-linear elasto-plastic behaviour of morsellised cortico-cancellous bone (MCB). It is found that the elastic modulus, E of MCB can be expressed as a linear function of the applied pressure, p. E varied from 3 to 30N/mm(2) for pressures up to 1N/mm(2). The visco-elastic behaviour of MCB can be described using a fourth-order Prony series. The plastic behaviour of MCB can be described using a Drucker Prager Cap (DPC) yield criterion, in which consolidation behaviour is described using an exponential function. The developed relationships allow MCB to be included in a realistic manner in finite element models, for example of the acetabular construct, following revision hip arthroplasty, carried out using the Slooff-Ling impaction grafting technique.

Bone Substitutes↗

Dependence of yield strain of human trabecular bone on anatomic site.

Understanding the dependence of human trabecular bone strength behavior on anatomic site provides insight into structure-function relationships and is essential to the increased success of site-specific finite element models of whole bones. To investigate the hypothesis that the yield strains of human trabecular bone depend on anatomic site, the uniaxial tensile and compressive yield properties were compared for cylindrical specimens from the vertebra (n=61), proximal tibia (n=31), femoral greater trochanter (n=23), and femoral neck (n=27) taken from 61 donors (67+/-15years). Test protocols were used that minimized end artifacts and loaded specimens along the main trabecular orientation. Yield strains by site (mean+/-S.D.) ranged from 0.70+/-0.05% for the trochanter to 0.85+/-0.10% for the femoral neck in compression, from 0.61+/-0.05% for the trochanter to 0.70+/-0.05% for the vertebra in tension, and were always higher in compression than tension (p<0.001). The compressive yield strain was higher for the femoral neck than for all other sites (p<0.001), as was the tensile yield strain for the vertebra (p<0.007). Analysis of covariance, with apparent density as the covariate, indicated that inter-site differences existed in yield stress even after adjusting statistically for density (p<0.035). Coefficients of variation in yield strain within each site ranged from only 5-12%, consistent with the strong linear correlations (r(2)=0.94-0.98) found between yield stress and modulus. These results establish that the yield strains of human trabecular bone can differ across sites, but that yield strain may be considered uniform within a given site despite substantial variation in elastic modulus and yield stress.

Adult↗

Magnetic-resonance imaging techniques for detection of elasticity variation.

The relative success of manual palpation in the detection of breast cancer would suggest that a method for remote palpation resulting in a measurement of tissue elasticity could provide a diagnostic tool for detecting cancerous lesions deeper within the breast. This presumption is based in part on the excellent contrast between neoplastic and normal tissue due to the large (orders of magnitude) relative variation in the shear elastic modulus. By comparison, the bulk deformational modulus maintains the same value to within 20% for most soft tissues. A specific method of magnetic-resonance imaging (MRI) which measures tissue displacements has been used in experiments with a phantom containing regions of increased Young's modulus as a demonstration. The spatial modulation of magnetization technique uses the displacement of a spatial grid pattern caused by spin saturation to track regional motion. Mathematical reconstruction of the distribution of elastic moduli is shown for select examples. Any modality, e.g., MRI, ultrasound, etc., which can detect local tissue motion with sufficient spatial resolution can be used and therefore the results presented here should give an indication of the utility of such motion tracking techniques to future measurement of tissue elasticity.

Biophysical Phenomena↗

A study of nano-mechanical properties and nano-scratch behavior of boron carbonitride films.

Boron carbonitride (BCN) films were deposited by d.c. unbalanced magnetron sputter deposition where a substrate bias ranging from -50 V to -300 V was applied to the sample. X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy were used to confirm the composition and bonding structure of the BCN films. Surface morphology and roughness were analyzed by atomic force microscopy. The nano-mechanical properties and nano-scratch behavior of the prepared films were determined by a nano-indentation system equipped with continuous stiffness measurement and lateral-force measurement attachments. The results indicate that there is little change in the content of B, C, and N. The films deposited are compounds with hybridized B-C-N bonds and the disordered degree of the structure increases with increasing the substrate bias. The substrate biasing can enhance the nanohardness, elastic modulus, nano-scratch resistance, and cohesion strength of the deposited films. During the nano-scratch test, plastic deformation and ploughing wear appears for the BCN films deposited at lower bias. Elastic deformation becomes the dominant deformation mechanism for the films deposited at higher bias. The coefficient of friction between the deposited BCN films and the diamond tip depends on the loading critical load. The increasing of the substrate bias leads to the improvement of the critical load and the elastic deformation proportion.

Adhesiveness↗

Noninvasive measurement of arterial blood pressure and elastic properties using photoelectric plethysmography technique.

The objective of this paper is to review our developed method for measuring noninvasively the arterial blood pressure as well as the mechanical properties of the vascular system in a thin portion of the biological segment such as human fingers or small animal extremities like rat tails and rabbit forelegs. This measurement is based on a principle called the 'volume-oscillometric method'. During the gradual change in cuff pressure, the amplitude of consecutive arterial volume pulsations associated with pulse pressure shows change characteristically due to the nonlinearity of arterial pressure-volume(P-V) relation. Arterial pressure can be accurately determined by detecting this characteristic change in the amplitude, while the arterial elastic properties such as P-V relationship and volume elastic modulus can be noninvasively obtained as a function of arterial transmural pressure, provided that the arterial volume changes are quantitatively determined during this pressure measurement. The validity and accuracy of this pressure and elasticity measurement with photoelectric plethysmography technique for detecting arterial volume changes are clearly demonstrated on the in vitro and in vivo experiments. Considering the simplicity and practicability of this measurement using the photoelectric plethysmography, we present a new portable instrument for the long-term ambulatory monitoring of indirect arterial pressure and a handy fully-automatic instrument for the noninvasive measurement of arterial elastic properties, and a few examples obtained by each instrument are also described.

Animals↗

Atomic force microscopy measurement of the elastic properties of the kidney epithelial cells.

Direct interaction force measurements using atomic force microscopy (AFM) were carried out between a silicon nitride tip and renal epithelial cells (Madin-Darby Canine Kidney-MDCK and proximal tubular epithelial cells derived from pig kidneys, LLC-PK1). The approaching (extending) portion of the force/distance curves is considered, and repulsive forces in the long range of 2-3 microm were seen in both MDCK as well as LLC-PK1 cells growing under normal conditions. The repulsive force in the shorter distance range of 50-200 nm was also observed, when cells were damaged exposing the underlying basal membrane. LLC-PK1 cells were more prone to damage than the MDCK cells, hence short-range forces were common in the former and long-range forces in the latter cells. The functional dependence of repulsive force on the indentation depth changes, at small indentation depth the force increases linearly, while at larger indentations the force is a quadratic function of the distance, which is attributed to the elasticity of the membrane and the solid-like response of cells, respectively. The oxalate treatment of cells for 2-4 h gives rise to an increase in the elastic modulus of the cells.

Animals↗

Passive stiffness in Drosophila indirect flight muscle reduced by disrupting paramyosin phosphorylation, but not by embryonic myosin S2 hinge substitution.

High passive stiffness is one of the characteristic properties of the asynchronous indirect flight muscle (IFM) found in many insects like Drosophila. To evaluate the effects of two thick filament protein domains on passive sarcomeric stiffness, and to investigate their correlation with IFM function, we used microfabricated cantilevers and a high resolution imaging system to study the passive IFM myofibril stiffness of two groups of transgenic Drosophila lines. One group (hinge-switch mutants) had a portion of the endogenous S2 hinge region replaced by an embryonic version; the other group (paramyosin mutants) had one or more putative phosphorylation sites near the N-terminus of paramyosin disabled. Both transgenic groups showed severely compromised flight ability. In this study, we found no difference (compared to the control) in passive elastic modulus in the hinge-switch group, but a 15% reduction in the paramyosin mutants. All results were corroborated by muscle fiber mechanics experiments performed on the same lines. The fact that myofibril elasticity is unaffected by hinge switching implies alternative S2 hinges do not critically affect passive sarcomere stiffness. In contrast, the mechanical defects observed upon disrupting paramyosin phosphorylation sites in Drosophila suggests that paramyosin phosphorylation is important for maintaining high passive stiffness in IFM myofibrils, probably by affecting paramyosin's interaction with other sarcomeric proteins.

Animals↗

Influence of thermal history on the structural and mechanical properties of agarose gels.

Using a multitechnique approach, two temperature domains have been identified in agarose gelation. Below 35 degrees C, fast gelation results in strong, homogeneous and weakly turbid networks. The correlation length, evaluated from the wavelength dependence of the turbidity, is close to values of pore size reported in the literature. Above 35 degrees C, gelation is much slower and is associated with the formation of large-scale heterogeneities that can be monitored by a marked change in the wavelength dependence of turbidity and visualised by transmission electron microscopy. Curing agarose gels at temperatures above 35 degrees C, and then cooling them to 20 degrees C, produces much weaker gels than those formed directly at 20 degrees C. Dramatic reductions in the elastic modulus and failure strain and stress are found in this case as a result of demixing during cure. An interpretation, based on the kinetic competition between osmotic forces (in favor of phase separation) and elastic forces (that prevent it) is proposed.

Elasticity↗

Mechanical response of tendon subsequent to ramp loading to varying strain limits.

OBJECTIVE: To determine the in vitro elastic limit of avian flexor tendons utilizing more current methodologies. DESIGN: Assess the mechanical changes between subfailure and subsequent failure ramps at various loading levels. BACKGROUND: Currently accepted values of elastic strain limits were determined utilizing older methodologies. Consequently, reported values are fairly small and imply matrix damage occurs with small strains. METHODS: Flexor tendons were loaded in vitro, to various subfailure strain levels between 1% and 14%, allowed to rest for 5 min, then taken to failure. Suture markers, across the midsubstance, and cryo-grip displacement were monitored for strain using a video strain analysis system and a linear variable displacement transducer, respectively. The mechanical changes between the various subfailure and failure ramp loadings were assessed. RESULTS: Varying strains of subfailure ramp loading did not influence (P>0.05) the ultimate tensile failure strength, elastic modulus, strain at failure, or strain energy density of tendons. In addition, residual strain after subfailure loading was not significant, nor was it influenced by the level of the subfailure loading. CONCLUSIONS: Tendon behaves elastically under ramp loading to significantly higher strains (nearly failure) than previously reported (4%). RELEVANCE: This study has found strain thresholds required to cause matrix damage to be significantly higher than previously thought, implying that matrix changes to acute loading events are more a result of the cellular response to the loading event. The clinical relevance is that the clinician may have a greater opportunity to prevent matrix changes than once thought by biochemically altering the cellular response.

Animals↗