PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Model performance”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Cross-validation performance of mortality prediction models.

Mortality prediction models hold substantial promise as tools for patient management, quality assessment, and, perhaps, health care resource allocation planning. Yet relatively little is known about the predictive validity of these models. We report here a comparison of the cross-validation performance of seven statistical models of patient mortality: (1) ordinary-least-squares (OLS) regression predicting 0/1 death status six months after admission; (2) logistic regression; (3) Cox regression; (4-6) three unit-weight models derived from the logistic regression, and (7) a recursive partitioning classification technique (CART). We calculated the following performance statistics for each model in both a learning and test sample of patients, all of whom were drawn from a nationally representative sample of 2558 Medicare patients with acute myocardial infarction: overall accuracy in predicting six-month mortality, sensitivity and specificity rates, positive and negative predictive values, and per cent improvement in accuracy rates and error rates over model-free predictions (i.e., predictions that make no use of available independent variables). We developed ROC curves based on logistic regression, the best unit-weight model, the single best predictor variable, and a series of CART models generated by varying the misclassification cost specifications. In our sample, the models reduced model-free error rates at the patient level by 8-22 per cent in the test sample. We found that the performance of the logistic regression models was marginally superior to that of other models. The areas under the ROC curves for the best models ranged from 0.61 to 0.63. Overall predictive accuracy for the best models may be adequate to support activities such as quality assessment that involve aggregating over large groups of patients, but the extent to which these models may be appropriately applied to patient-level resource allocation planning is less clear.

Discriminant Analysis↗

A model for predicting performance on the NBME Part I examination.

Multiple regression analyses were employed to determine the relationships between achievement variables as predictors of the performance on Part I of the National Board of Medical Examiners examinations (NBME-I) of 366 medical students. The students' examination score averages in first- and second-year basic science courses were sequentially added to a composite Medical College Admission Test (MCAT) score to investigate the increases in prediction accuracy. Four prediction equations were cross validated on two subsequent medical school classes. While the multiple correlation between the predicted NBME-I score and the actual score significantly increased as first- and second-year course examination scores were added to the equations, the overall accuracy in predicting passing or failing did not substantially increase. The most useful equation employed a combination of the MCAT score and the first semester anatomy course examination score. The NBME-I predictions were given by letter to the 1984 and 1985 students approximately a year before they were to take the NBME-I examination so that students at risk of failure could undertake remedial study.

College Admission Test↗

Use of statistical models to evaluate racing performance in thoroughbreds.

OBJECTIVE: To develop a statistical model to evaluate the influence of specific parameters on racing performance in Thoroughbreds. DESIGN: Survey. SAMPLE POPULATION: Racing records of Thoroughbreds performing in Louisiana from 1981 to 1985. PROCEDURE: Race results for 20 randomly selected days from 5 racetracks during 5 years were analyzed, using regression analysis. RESULTS: The most influential parameter was distance raced. There were significant differences in racing performance among horses at different tracks. At the tracks examined, fast racing surfaces resulted in significantly faster finish times than good racing surfaces, and good racing surfaces resulted in significantly faster finish times than muddy racing surfaces. Finish times also were significantly faster as a function of increasing purse amount and age of horse. Finish times were significantly faster during quarter 4 (summer) and significantly slower during quarter 1 (fall). Races were run at significantly faster times as the number of the race progressed during the day. The finish times were significantly slower as the number of horses competing in the race increased, as the weight carried by the horse increased, and as the starting position away from the rail increased. CLINICAL IMPLICATIONS: The coefficients used in the statistical model of this report may be used by researchers to compare before injury and after treatment finish times. The coefficients can be used to standardize past racing performances to uniform conditions, thus permitting comparison from 1 race to another to determine success of treatments and to inform owners of prognosis.

Animals↗

[Electromagnetic interference between automatic defibrillators and digital and analog cellular telephones].

BACKGROUND AND OBJECTIVES: Functional pacemaker interference by mobile telephones has been described with analogical systems and with possible greater influence, digital systems, including inhibition and inadequate pacing. The influence of both system has not been extensively studied in patients with implantable cardioverter defibrillators (ICD). PATIENTS AND METHODS: We studied the influence of mobile phones, both digital and analogic network, on the performance of several models of defibrillators, in a standardised test set up designed to provide high sensitivity. The purpose of our study was to establish whether there are any influences on ICD functions, both in in vivo and in in vitro models. Several mobile phones, with different transmission powers, were moved towards the defibrillator and the electrode, under continuous documentation of defibrillator sensing and interrogation afterwards. The experimental model was performed with the aid of an arrhythmia simulator (Intersim) and demo-defibrillators. The tests were repeated both in and out of a solution of saline water with an impedance within normal human limits. RESULTS: Partial loss of telemetry was found in 14 patients, 8 with analogical phones and 6 with digital phones. Fourteen patients showed alterations only on the surface electrocardiogram channel and five on the intracavitary channel. The same results were reproduced in the in vitro model. However, the in vitro test allowed us to simulate multiple ventricular arrhythmias, and demonstrate the normal sensing and functioning of the defibrillator during a "spontaneous" arrhythmia. After testing, we demonstrate that no real oversensing/undersensing was documented in any device. There was no evidence of ICD reprogramming or pacing inhibition. In particular, no inadequate therapies were delivered. CONCLUSIONS: a) in our series, we have not demonstrated clinically significant electromagnetic interferences with mobile phones of digital or analogical networks: b) the in vitro model allowed us to conclude that even if a spontaneous arrhythmia appears, the function of the defibrillator is not altered; c) the use of mobile phones seems to be safe for defibrillator patients, and d) however, some basic rules, such as to maintain the phone at least 15 cm away from the defibrillator, are advised.

Defibrillators, Implantable↗

Performance of a model for a local neuron population.

A model of a local neuron population is considered that contains three subsets of neurons, one main excitatory subset, an auxiliary excitatory subset and an inhibitory subset. They are connected in one positive and one negative feedback loop, each containing linear dynamic and nonlinear static elements. The network also allows for a positive linear feedback loop. The behaviour of this network is studied for sinusoidal and white noise inputs. First steady state conditions are investigated and with this as starting point the linearized network is defined and conditions for stability is discovered. With white noise as input the stable network produces rhythmic activity whose spectral properties are investigated for various input levels. With a mean input of a certain level the network becomes unstable and the characteristics of these limit cycles are investigated in terms of occurence and amplitude. An electronic model has been built to study more closely the waveforms under both stable and unstable conditions. It is shown to produce signals that resemble EEG background activity and certain types of paroxysmal activity, in particular spikes.

Action Potentials↗

A four-parameter linear model for analysing cardiorespiratory data in post-operative cardiac patients.

This paper investigates the possibility of characterizing the differences between normal- and high-risk postoperative cardiac patients on the basis of four parameters related to a simple linear model of cardiorespiratory performances. The model comprises three subsystems representing cardiac, vascular and respiratory functions, respectively. These parameters, determined from physiological variables measured in the Intensive Care Unit, seem useful for clinical evaluation of patient status. In fact, their values quantify the improved cardiovascular and respiratory response that normal-risk patients exhibit to increasing metabolic needs after hypothermic treatment, with less utilization of blood oxygen reserve. In addition, a set of three parameters derived from the proposed four allows a prediction of patient class membership with an error lower than 7% when used with a Bayes quadratic classifier.

Cardiac Surgical Procedures↗

Improved ECG models for left ventricular mass adjusted for body size, with specific algorithms for normal conduction, bundle branch blocks, and old myocardial infarction.

Considerable efforts have been invested recently to improve electrocardiographic (ECG) classification accuracy for left ventricular hypertrophy (LVH). This study examines how LVH classification accuracy is influenced by (1) the selection of an echocardiographic standard for LVH, (2) LVH severity level in the test groups, and (3) the adjustment of LVH criteria for obesity and age. Using data obtained from large, community-based populations, this study explores prospects for improving ECG models for LVH classification and examines some of the general characteristics of newer ECG models for estimating left ventricular mass (LVM) on a continuous scale. The results indicate that the apparent ECG classification accuracy for LVH is substantially influenced by echocardiographic standards and criteria for LVH, LVH severity level, and selection criteria for test populations, and these differences explain some of the often substantial differences in test results from clinical versus community-based evaluation studies. The low reproducibility of echocardiographic LVM as the standard is a limiting factor in attempts to improve ECG criteria for LVH and LVM prediction models. Adjustment of ECG amplitudes to anthropometric factors that simultaneously influence LVM may result in confounding effects and may lead to the development of inappropriate models. The performance of ECG models for LVM prediction improved substantially by the inclusion of body weight as a covariate with ECG variables. The addition of standing height and various covariates reflecting obesity did not improve LVM prediction accuracy. Compared to the older LVM prediction models of the Novacode ECG program, the correlation between echocardiographic and ECG estimates of LVM increased sufficiently (from 0.33 to 0.54 in women and from 0.46 to 0.62 in men) to suggest that these improved ECG models are suitable for monitoring LVH progression/ regression in study groups participating in hypertension intervention trials.

Adult↗

A spectral histogram model for texton modeling and texture discrimination.

We suggest a spectral histogram, defined as the marginal distribution of filter responses, as a quantitative definition for a texton pattern. By matching spectral histograms, an arbitrary image can be transformed to an image with similar textons to the observed. We use the chi(2)-statistic to measure the difference between two spectral histograms, which leads to a texture discrimination model. The performance of the model well matches psychophysical results on a systematic set of texture discrimination data and it exhibits the nonlinearity and asymmetry phenomena in human texture discrimination. A quantitative comparison with the Malik-Perona model is given, and a number of issues regarding the model are discussed.

Discrimination, Psychological↗

Psychogenic voice disorders in performers: a psychodynamic model.

Psychogenic voice disorders are not infrequently encountered in the busy voice clinic. A clinician-friendly psychodynamic model and a multidisciplinary management approach are presented which have proven helpful for our voice team and our patients. In essence the formulation revolves around an "event" occurring, which may be either organic or psychological in nature. The ensuing dysphonia then leads to emotional consequences which in turn have physical consequences on the vocal tract. The situation can become reinforcing and illness behaviors develop. Elucidating this event/process to the patient improves the likelihood of a successful long-term outcome. The diagnostic and management roles of the various team members are discussed.

Adult↗

Cardiomyopathic and healthy acidotic hamster hearts: mitochondrial activity may regulate cardiac performance.

A 50% decrease in adenine nucleotides and a 60% decrease in adenosine triphosphate concentration was found in glucose perfused myopathic Syrian hamster heart (240 days old) whereas there was an 18% decrease and 40% decrease respectively in acidotic healthy Syrian hamster heart re-equilibrated with a physiological medium. Correspondingly, there was a 60% decrease in cardiac performance with both models. Developed pressure fell when the phosphorylation potential decreased to less than or equal to 2; however, the heart recovered if mitochondrial activity was activated. If a substrate such as pyruvate or ribose was used with either model cardiac performance returned to near normal, although adenine nucleotide and adenosine triphosphate concentrations were further depressed. With glucose as substrate cardiomyopathic hearts, healthy acidotic hearts, and healthy acidotic hearts re-equilibrated with glucose as substrate had low pyruvate concentrations; limited availability of pyruvate depressed mitochondrial activity. Like the myopathic hearts the re-equilibrated acidotic hearts had high myocardial pyruvate concentrations, above normal ratios of phosphocreatine to creatine, and near normal oxygen consumption, developed pressure, dP/dt, and cyclic adenosine monophosphate concentrations when re-equilibrated with a medium containing pyruvate or ribose as substrate, although adenosine triphosphate and adenine nucleotide concentrations were severely depressed. When adenosine triphosphate values fell from 24 to 2 mumol X g-1 dry weight in the pyruvate or ribose perfused and normal functioning heart the heart stopped beating with no progressive fall in performance before termination of the metabolic processes.

Acidosis↗

Laboratory assessment of the Bird T-Bird VS ventilator performance using a model lung.

We assessed the Bird T-Bird VS ventilator using a model lung constructed to standard 10651-1 of the International Standards Organization. We used different combinations of lung compliance and airway resistance to simulate normal and diseased adult and paediatric lungs. Different preset tidal volumes at various respiratory rates were delivered to the model lung and compared with the actual measured tidal volumes. The results showed that the delivered tidal volumes were within the manufacturer's specification of +/- 10% of the preset tidal volumes in normal adult and paediatric combinations of lung compliance and airway resistance. The ventilator can be powered by mains electricity supply or battery and requires only optional compressed oxygen. The ventilator is suitable for the provision of advanced ventilatory support during prolonged patient transfer.

Adult↗

Application of volume growth and survival graphs in the evaluation of four process-based forest growth models.

Volume growth and survival (VGS) graphs, which show volume growth rate and risk of mortality for individual trees (or tree size classes), have been proposed as a tool for assessing the validity of models that describe the development over time of tree size distributions within forest stands. We examined the utility of the VGS method in evaluating four process-based models. The performance of the models FORSKA, 4C, MORG, and PipeQual is analyzed against long-term data from a Scots pine stand in Evo, Finland, and the models FORSKA and 4C are also assessed with respect to data from a beech stand in Fabrikschleichach, Germany. Comparison of the measurement-based VGS graphs with those produced from the model-based data shows that although the models yield similar stand-level predictions, they can differ widely in their projections of individual tree growth and size distributions. Examination of the discrepancies between models and data in the context of the VGS graphs reveals several areas in which the models could be improved. We conclude that the method is useful in model evaluation, especially if used in combination with indicators of stand structure, such as the height/diameter ratio.

Journal Article↗

Using ergodic theory to assess the performance of ecosystem models.

Ecosystem simulation models are designed to assess the flux of energy, water, carbon and nitrogen according to a given vegetation type. The reliability of the modeled results is determined by model validations. Model validations are typically done using classical statistical methods like regression analysis of predicted versus observed values, paired t statistics and error assessment procedures to characterize the quality of current and future model predictions. All these validation efforts concentrate on static aspects of the model but fail to describe the model dynamics. In this paper, we introduce methods from ergodic theory to analyze the dynamic behavior of ecosystem models. We describe (1) how the attractor representation of model behavior can be reconstructed from a time series of model outputs, and (2) what we can learn from the attractor to assess the model dynamics. As an application example, we provide simulation results for two important pine forest ecosystems in Austria, i.e., 23 Cembran pine and 16 Scots pine stands. These stands were simulated with three model parameterizations: one representing a generic, evergreen needle-leaf forest, and two species- specific parameter sets, one for Cembran pine and one for Scots pine. First, we applied standard validation methods to get static measures of model accuracy and precision. Next, we used ergodic theory to assess model dynamics. A comparison of both analyses reveals important issues related to model dynamics, such as the finding that the occurrence of instabilities in model behavior may not be detected by standard validation methods. Using ergodic theory, we were able to reconstruct the attractors of model behavior. In the attractor describing model dynamics for Cembran pine, simulated with the generic, evergreen needle-leaf forest parameter set, we detected instability in model behavior. We identified this instability as a riddled basin configuration, which is a strong indicator for the occurrence of a chaotic model behavior that may result in random predictions. Our results suggest that ergodic theory is a useful tool for assessing inconsistencies in the dynamics of ecosystem model simulations that have not been detected by standard statistical validation methods.

Climate↗

In vitro performance of venous valve prostheses. An experimental model study.

The performance of fresh and glutaraldehyde fixed bovine jugular vein valves (10 mm diameter) was investigated in an experimental flow loop that provides adjustable flow rates and a downstream oscillatory pressure. Three different venous valve (VV) conduit geometries (curved [C], straight [S], and tapered [T]), were tested. The flow loop consisted of two independently adjustable components, with the mean flow generated by adjusting the elevation difference between the head tank and outflow chamber. An adjustable sinusoidal pressure pulse was superimposed on the downstream of a VV to mimic the respiratory effects. Flow visualizations were made using 100 microns mica chip tracers in the laser illuminated flow fields. To assess VV performance under various flow conditions, the closure opening (CO), partial opening (PO), and leaflet fluttering (LF) were evaluated. At a given pulse pressure, the three conduits required different flow rates to reach CO mode. At 12 cm H2O pulse pressure, the fresh valve in C-conduit exhibited stable CO operation at a flow rate of 1.01 ml/sec. That in S and T conduits required 1.67 ml/sec and 2.25 ml/sec, respectively. At higher flow rates, PO and LF performances were observed in all three conduits. Different threshold values of pulse pressure were needed to reestablish the CO operation mode for the C, S, and T conduits, individually. These observations provide some insight into the role of conduit geometry and sinus configuration in the function of VV.

Animals↗