PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Robotics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Laboratory automation using robotics and information management systems.

Many advances have been made in laboratory automation dealing with robotics and data management. There have been many different approaches to these technologies and many successful applications. Current methods employed in automated techniques utilize robotic processors and arms to manipulate and analyze samples, and computerized management of the data generated by these workhorses.

Clinical Laboratory Information Systems↗

Screening yeast artificial chromosome libraries with robot-aided automation.

Screening of collections of yeast artificial chromosomes utilizing the polymerase chain reaction (PCR) requires large numbers of reactions in parallel. Four steps were implemented to reduce the labor involved: (a) The number of initial samples for DNA extractions was decreased by compressing libraries up to 12-fold. (b) DNA extraction from yeast clones was robot assisted. (c) A BIOMEK 1000 station was adapted to pipette samples for PCR assays. (d) Sample preparation was integrated with a temperature cycler constructed to carry out up to 576 reactions in six 8 x 12-well trays. The implementation of these steps increases the number of reactions per person per day by an order of magnitude. In tests with X-chromosome-specific probes, the robot-aided screening recovered all of the clones detected by slower manual methods.

Chromosomes, Artificial, Yeast↗

Vanguard--a European robotic astrobiology-focussed Mars sub-surface mission proposal.

We present a new European Mars mission proposal to build on the UK-led Beagle2 Mars mission and continue its astrobiology-focussed investigation of Mars. The small surface element to be delivered to the Martian surface--Vanguard--is designed to be carried by a Mars Express-type spacecraft bus to Mars and adopts a similar entry, descent and landing system as Beagle2. The surface element comprises a triad of robotic devices--a lander, a micro-rover of the Sojourner class for surface mobility, and three ground-penetrating moles mounted onto the rover for sub-surface penetration to 5 m depth. The major onboard instruments on the rover include a Raman spectrometer/imager, a laser plasma spectrometer, an infrared spectrometer--these laser instruments provide the basis for in situ "remote" sensing of the sub-surface Martian environment within a powerful scientific package. The moles carry the instruments' sensor head array to the sub-surface. The moles are thus required to undergo a one-way trip down the boreholes without the need for recovery of moles or samples, eliminating much of the robotic complexity invoked by such operations.

Equipment Design↗

Humans and robots: hand in grip.

As we move boldly forward into the 21st century, there has rarely been a more exciting time in which to contemplate the future of space exploration. The President of the United States has made a new and ambitious commitment to exploration of the solar system and beyond. Robotic partners will play a vital role in ensuring that the Vision is truly "sustainable and affordable". Relevant science and technology will be discussed with particular emphasis on expertise from NASA Ames Research Center of which the author is Director. The likely evolution of the balance between human explorers and robotic explorers will be addressed.

Artificial Intelligence↗

Robotics in thoracic surgery.

Surgical use of robotics, or computer-assisted surgical systems (CAS), has evolved over the last 10 years; for the treatment of chest diseases, however, the development has really occurred in the last 3 to 4 years. This brief history means that there have been few publications in the medical literature, and those that exist are mostly case reports. Moreover, because of this modest experience, robotic thoracic procedures currently take more time than nonrobotic cases and, thus, are more expensive. The surgical learning curve appears to be steep, especially for the more complex procedures. As surgeons gain greater experience and the complexity and cost of the equipment are reduced, we should expect to see greater utility of CAS in thoracic surgery.

Esophagus↗

Current status of robotically assisted coronary revascularization.

This article reviews the current status of totally endoscopic coronary revascularization using telemanipulation systems for robotic assistance. Current challenges in implementing a robotic surgical program are discussed, and application of the technology in both arrested and beating heart procedures is considered.

Cardiac Surgical Procedures↗

Gynecologic use of robotically assisted laparoscopy: Sacrocolpopexy for the treatment of high-grade vaginal vault prolapse.

Transabdominal sacrocolpopexy is an excellent treatment option for patients with high-grade vaginal vault prolapse, with long-term success rates ranging from 93% to 99%. However, it is associated with increased morbidity compared with vaginal repairs. In this article, we describe a novel minimally invasive technique of vaginal vault prolapse repair and present our initial experience. The surgical technique involves placement of 4 laparoscopic ports, 3 for the surgical robot and 1 for the assistant. A prolene mesh is then attached to the sacral promontory and to the vaginal apex using nonabsorbable expanded polytetrafluoroethylene sutures. At the end of the case, the mesh material is covered by the peritoneum. A total of 20 patients underwent a robot-assisted laparoscopic sacrocolpopexy at our institution in the past 18 months for severe symptomatic vaginal vault prolapse; 8 of the 20 (40%) underwent a concomitant anti-incontinence procedure. Mean follow-up was 5.1 (range, 1-12) months and mean age was 66 (range, 47-82) years. The mean total operative time was 3.2 (range, 2.25-4.75) hours. Of these patients, 1 was converted to an open procedure secondary to unfavorable anatomy. All but 1 patient, who left on postoperative day 2, were discharged from the hospital after an overnight stay. Complications were limited to mild port-site infections in 2 patients, which resolved with oral antibiotic therapy. Recurrent grade 3 rectocele developed in 1 patient, but there was no evidence of cystocele or enterocele. Significant incontinence (>1 pad/day) was present in 2 patients. All 18 patients reported being satisfied with the outcome of their surgery and all 10 would recommend it to a friend. This novel technique for vaginal vault prolapse repair combines the advantages of open sacrocolpopexy with the decreased morbidity and improved cosmesis of laparoscopic surgery. It is associated with decreased hospital stay, low complication and conversion rates, and high rates of patient satisfaction. Although our early experience is encouraging, long-term data are needed to confirm these findings and establish longevity of the repair.

Aged↗

Robotically assisted donor nephrectomy for kidney transplantation.

The application of minimally invasive techniques in the field of transplant surgery is expanding the number of living-related donor nephrectomies. In 2003, the number of living kidney donors exceeded the number of cadaveric donors. The laparoscopic techniques already have been described extensively. Our experience with robotic donor nephrectomy began in October 2000. In this article, we describe the surgical technique for living-related donor nephrectomies using robotic technology (computer-enhanced surgery), as well as the most important considerations regarding the pre- and postoperative management of this group of patients.

Humans↗

Changes in motoneuron excitability in hemiplegic subjects after passive exercise when using a robotic arm.

OBJECTIVE: To test the hypothesis that motoneuron excitability in stroke subjects is influenced by peripheral sensory input through passive exercise to the hemiplegic upper extremity. DESIGN: Case-control prospective study. SETTING: Physical medicine and rehabilitation inpatient and outpatient clinic at a tertiary Veterans Affairs medical center. PARTICIPANTS: Nineteen hemiplegic adult subjects with a history of a cerebrovascular event. INTERVENTION: A standardized passive exercise program was performed on the right upper extremity by using a robotic arm. Nerve conduction study of the median nerve was obtained before and after the exercise. Maximum onset and peak amplitudes of the Hoffmann reflex (Hmax) and motor response (Mmax) wave were recorded. MAIN OUTCOME MEASURES: Hmax, Mmax, and Hmax/Mmax ratio. RESULTS: Immediately after passive exercise, there was no significant alteration in the Hmax (P=.94), Mmax (P=.60), or Hmax/Mmax ratio (P=.53) as compared with pre-exercise evoked responses. CONCLUSIONS: Peripheral proprioceptive input with passive exercise does not cause appreciable change in the Hmax/Mmax ratio, suggesting that motoneuron excitability of the affected upper extremity in stroke subjects is not influenced by passive robotic intervention.

Case-Control Studies↗

A high yield robotic synthesis of 9-(4-[18F]-fluoro-3-hydroxymethylbutyl)guanine ([18F]FHBG) and 9-[3-[18F]fluoro-1-hydroxy-2-propoxy)methyl]guanine([18F] FHPG) for gene expression imaging.

The aim of this study was to develop an automated synthesis of 9-(4-[(18)F]-fluoro-3-hydroxymethylbutyl)guanine ([(18)F]FHBG) and 9-[(3-[(18)F]fluoro-1-hydroxy-2-propoxy)methyl]guanine ([(18)F]FHPG) using a Scanditronix Anatech RB III robotic system. [(18)F]HF was produced via (18)O(p, n)(18)F using a Scanditronix MC17F cyclotron. On average, a typical run produced [(18)F]FHBG and [(18)F]FHPG with an uncorrected radiochemical yield of 19% and 16%, respectively, at end of synthesis (EOS) from irradiation of 95% enriched [(18)O]water. The total synthesis time was 80 min. The retention time of [(18)F]FHBG and [(18)F]FHPG (the radio-peak) was 3.9 and 4.0 min, respectively, which was consistent with the [(19)F]FHBG and [(19)F]FHPG ultraviolet peak. The radiochemical purity was greater than 97%. A robotic, automated method for [(18)F]FHBG and [(18)F]FHPG radiosynthesis is therefore feasible. The radiation burden for the operator can be reduced as much as possible. Sufficient radioactivities of [(18)F]FHBG and [(18)F]FHPG could be obtained for non-invasive monitoring the expression of transfected gene in vivo with positron emission tomography (PET).

Equipment Design↗

Robotic totally endoscopic coronary artery bypass and catheter based coronary intervention in one operative session.

A 56-year-old male patient underwent robotically assisted totally endoscopic left internal mammary artery (LIMA) to left anterior descending artery (LAD) grafting. After protamine administration complete heart block developed in the patient. On intraoperative angiography the LIMA to LAD graft was perfectly patent but an acute occlusion of the right coronary artery (RCA) was noted. We performed an immediate on table percutaneous coronary angioplasty and stent placement to the RCA. The heart regained sinus rhythm and the wall motion abnormalities on the back wall of the heart resolved. No clinical symptoms indicating ongoing myocardial ischemia were noted postoperatively. This case demonstrates that a hybrid procedure of robotic totally endoscopic coronary artery bypass grafting and catheter based coronary intervention is feasible in one simultaneous session.

Angioplasty↗

Robotically-assisted left atrial fibrillation ablation and mitral valve repair through a right mini-thoracotomy.

A combined robotic-assisted left atrial ablation and mitral valve repair was done through a 5-cm right anterior mini-thoracotomy. The patient was a 54-year-old man with severe mitral regurgitation and a 10-month history of persistent atrial fibrillation. The patient underwent off-pump, beating heart epicardial peripulmonary vein microwave ablation using the FLEX 10 catheter (AFx Inc, Fremont, CA), followed by supplemental on-pump endocardial lesions. The procedure was done using the da Vinci surgical robot (Intuitive Surgical Inc, Sunnyvale, CA). The mitral valve repair consisted of a No. 38 Cosgrove annuloplasty band implantation (Edwards Life Sciences, LLC, Irvine, CA). The postoperative recovery was uneventful, and the patient maintained normal sinus rhythm.

Atrial Fibrillation↗

Robotic resection of an aortic valve papillary fibroelastoma.

Robotic technology has been applied to multiple cardiac surgical procedures. Purported benefits include decreased tissue trauma, reduced postoperative bleeding, fewer blood product transfusions, and shorter lengths of stay. We describe the case of a 50-year-old man with an incidentally discovered 1-cm mobile mass on the edge of the aortic valve noncoronary leaflet. The patient underwent robotic minimally invasive resection. The pathologic examination revealed papillary fibroelastoma.

Aortic Valve↗

Adhesiolysis is facilitated by robotic technology in reoperative cardiac surgery.

Over a 2-year period, 5 patients who required reoperative chest surgery underwent robotic adhesiolysis with the da Vinci (Intuitive, Sunnyvale, CA) system. Resternotomy was performed under direct visualization for coronary revascularization (n = 2) or valve replacement (n = 1). A fourth patient required coronary revascularization after a previous axilloaxillary bypass. The final case involved the preparation of a substernal pathway for a gastric pull-up. In all cases adhesions were taken down without injury to the underlying structures. All grafts were preserved, and all patients recovered uneventfully. Robotic adhesiolysis is a versatile technique that allows careful lysis of adhesions and minimizes the risk of major complication during reoperative chest surgery.

Adult↗

Totally endoscopic robot-assisted transmyocardial laser revascularization.

We describe the first use of totally endoscopic, off-pump, robot-assisted transmyocardial laser revascularization in a 58-year-old man with refractory rest angina who had undergone two prior coronary bypass operations. Preoperative testing revealed reversible ischemia of the left ventricular apex with diffuse coronary atherosclerotic disease not suitable for further treatment by conventional techniques. During surgery a fiberoptic laser delivery system was manipulated using the da Vinci robotic system to create 25 transmural channels in the left ventricular myocardium. Postoperative recovery was rapid and uneventful, with complete relief of anginal symptoms at 30 days.

Endoscopy↗

Robotically assisted totally endoscopic atrial septal defect repair: insights from operative times, learning curves, and clinical outcome.

BACKGROUND: Remote access perfusion and robotics have enabled totally endoscopic closure of atrial septal defect and patent foramen ovale. The aim of this study was to address learning curve issues of totally endoscopic atrial septal defect repair on the basis of a single-center experience and to investigate whether long cardiopulmonary bypass and aortic occlusion times influence intraoperative and postoperative outcomes. METHODS: Seventeen patients (median age, 35 years; range, 16 to 55 years) underwent totally endoscopic atrial septal defect repair using remote access perfusion and robotic technology (da Vinci telemanipulation system). Learning curves were assessed by means of regression analysis with logarithmic curve fit. The effect of operative variables on clinical outcome was analyzed by linear regression using the Spearman's rho coefficient. RESULTS: No operative mortality or serious surgical complications were observed. No residual shunt was detected at intraoperative or postoperative echocardiography. Significant learning curves were noted for total operative time: y(min) = 406 - 49 ln(x) (r2 = 0.725; p = 0.002); cardiopulmonary bypass time: y(min) = 225 - 42 ln(x) (r2 = 0.699; p = 0.003); and aortic occlusion time: y(min) = 117 - 25 ln(x) (r2 = 0.517; p = 0.04), x = number of procedures. Median ventilation time, intensive care unit stay, and hospital length of stay were 7 hours (range, 2 to 19 hours), 26 hours (range, 15 to 120 hours), and 8 days (range, 5 to 14 days), respectively. No correlation was detected between cardiopulmonary bypass time and intubation time (r2 = 0.283; p = 0.326), intensive care unit stay (r2 = -0.138; p = 0.639), or total length of stay (r2 = 0.013; p = 0.962). CONCLUSIONS: Totally endoscopic atrial septal defect repair can be performed safely, and learning curves for operative times are steep. Longer cardiopulmonary bypass times had no negative impact on intraoperative and postoperative outcome.

Adolescent↗

Frameless image-guided intracranial and extracranial radiosurgery using the Cyberknife robotic system.

The Cyberknife is an image-guided robotic radiosurgery system. The image guidance system includes a kilovoltage X-ray imaging source and amorphous silica detectors. The radiation delivery device is a mobile X-band linear accelerator mounted onto a robotic arm. Through a highly complex interplay between the image guidance system, an automated couch, and the high-speed linear accelerator, near real-time tracking of the target is achieved. The Cyberknife gained Federal Drug Administration clearance in the United States in 2001 for treatment of tumors "anywhere in the body where radiation treatment is indicated." Because the Cyberknife system does not rely on rigid fixation of a stereotactic frame, tumors outside of the intracranial compartment, even those tumors that move with respiration can be treated with a similar degree of ease as intracranial targets. A description of the Cyberknife technology and a review of some of the current intracranial and extracranial applications are detailed herein.

Humans↗

The study of control methods for the robotic testing system for human musculoskeletal joints.

Biomechanical testing of human musculoskeletal joints not only requires qualified testing machines and devices, but also needs an excellent control method to obtain better experimental results. In this paper, we take the human functional spinal unit (FSU) as an example to study how to improve the performance of the robotic testing system. First, the mechanical characteristics of the FSU are described and the simplified model (a rigid body-spring system) for the specimen is given. Because the location of the center of rotation (COR) of the specimen affects the performance of the system, so a comprehensive analysis on the location of the COR is carried out. Furthermore, the performance of the robotic testing system can be also improved through the improvement of the control methods. Two control methods have been proposed, one is the improved hybrid control and the other is fuzzy logic control (FLC).

Fuzzy Logic↗