PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Signal Processing, Computer-Assisted”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Interleukin-1 is a motility factor for human breast carcinoma cells in vitro: additive effect with interleukin-6.

Interleukin-1 beta (Il-1 beta) and interleukin-1 alpha (Il-1 alpha) were shown to act as motility factors for the human breast carcinoma cell lines SK-BR-3 and ZR-75-1 in vitro. Both cytokines induced transition from the stationary to the motile phenotype (spreading). Il-1 beta stimulated translocation, shape change and random migration (chemokinesis) of SK-BR-3 cells as demonstrated by time-lapse video recordings and by a modified Boyden chamber assay. Interleukin-6 (Il-6) stimulated spreading of the SK-BR-3 cells; an additive effect with Il-1 beta on spreading and fast plasma membrane movements was evidenced. In the SK-BR-3 cell line, the signal transduction of Il-1 beta and Il-6 differed, since only the effect of Il-6 on spreading was sensitive to pertussis toxin. Both Il-1 beta and Il-6 required protein synthesis to stimulate spreading, since cycloheximide inhibited the effect of the cytokines. Induction of an autocrine loop of Il-6 in the SK-BR-3 cells by Il-1 beta was unlikely, since after stimulation with Il-1 beta, no induction of Il-6 activity was measured, nor was inhibition of stimulated spreading seen in the presence of an antiserum against Il-6. Addition of Il-8 or of an antiserum against Il-8 did not affect spreading. We concluded that Il-1 and Il-6 could act as motility factors for human breast carcinoma cells, in both an independent and an additive way.(ABSTRACT TRUNCATED AT 250 WORDS)

Breast Neoplasms↗

[Clinical potentialities and limitations of two- and three-dimensional time-of-flight MR angiography in the diagnosis of carotid stenosis].

For diagnosing a carotid artery stenosis, 26 patients underwent MR angiography. A spin echo (SE) sequence with presaturation on which the flowing blood appears with low signal intensity was applied, as well as a two- and three-dimensional gradient echo (GRE) sequence with flow compensation, showing blood flow with high signal intensity. Subsequently, projection angiograms were made from the MR images with a maximum intensity projection algorithm. Degree, length and localisation of a carotid artery stenosis were reviewed. To find out the clinical usability, the results of the MR angiograms were compared subsequently with the findings of intravenous digital subtraction angiography (i.v. DSA). In comparison with DSA a correlation in the degree of stenosis was noticed in 42 out of 48 SE-, in 39 out of 52 2-D GRE and in 41 out of 48 3-D GRE sequence angiograms. The length of 34 moderate and severe stenoses, demonstrated by DSA, was overestimated 5 times with the SE-sequence, 9 times with the 3-D and 23 times with the 2-D GRE sequence. MR angiography with a 3-D GRE sequence is suitable for screening for carotid artery stenosis. In cases of severe stenosis an SE sequence should be performed for more precise delineation of the stenotic lesion.

Aged↗

An NMR phased array for human cardiac 31P spectroscopy.

A four-coil phased-array 31P NMR receiver was designed and tested for human cardiac applications, to determine whether the combination of relatively high signal-to-noise ratio (SNR) and large field of view produced in 1H imaging is also realized for in vivo 31P spectroscopy. Spectra were acquired in parallel from an array of four overlapping 6.5-cm surface coils using one- and two-dimensional phase-encoding pulse sequences and were optimally combined to yield composite spectroscopic images. The phased array was found to generate useful 31P spectra from a 2.5-fold wider lateral region around the anterior myocardium than a single receiver of the same size as the array elements, with no increase in imaging time. In addition, the sensitive depth was increased by up to 2 cm over that of a single coil. Spectra could be acquired in roughly 15 min from a region extending to the middle of the heart, with voxel sizes of 2 x 2 x 4 cm3. For the average heart voxel, the SNR of the combined spectrum was higher than that of the best spectrum from any one coil in the array by 30%, with some voxels showing an increase as high as 60%.

Heart↗

Magnetic resonance angiography techniques.

After a radio frequency pulse, the decay of the magnetic resonance (MR) signal is described by two relaxation processes, T1 and T2. T1 describes the rate at which the magnetization realigns itself along the external magnetic field direction (ML), and T2 describes the rate of decay of the magnetization component along the transverse axis (MT). Magnetic resonance angiography (MRA) sequences have been developed that encode flow as changes in the apparent T1 or T2 of the moving blood relative to stationary tissues. MRA sequences typically use either time-of-flight (TOF) techniques to encode T1 or phase-contrast techniques to encode T2. TOF techniques encode flow as an apparent T1 shortening through the wash-in of fully relaxed blood from outside the image volume. The shorter T1 produces an enhancement of vascular structures relative to stationary tissues. TOF methods may use either sequential two-dimensional, three-dimensional, or multi-slab three-dimensional imaging sequences to produce a three-dimensional MRA data set. Phase-contrast methods use additional magnetic field gradients to encode flow as shifts in the phase of MT. Both TOF and phase-contrast methods use maximum intensity projection (MIP) images displayed in a cine format to aid in the visualization of three-dimensional vascular structures.

Animals↗

Quantification of inter- and intra-nuclear variation of fluorescence in situ hybridization signals.

This study aims at the quantification of specific DNA sequences by using fluorescence in situ hybridization (ISH) and digital imaging microscopy. The cytochemical and cytometric aspects of a quantitative ISH procedure were investigated, using human peripheral blood lymphocyte interphase nuclei and probes detecting high copy number target sequences as a model system. These chromosome-specific probes were labeled with biotin, digoxigenin, or fluorescein. Quantification of the fluorescence ISH signals was performed using an epifluorescence microscope equipped with a multi-wavelength illuminator, and a cooled charge coupled device (CCD) camera. Specific image analysis programs were developed for the segmentation and analysis of the images provided by ISH. The fluorescence intensity distributions of the ISH spots showed large internuclear variation (CVs up to 65%) for the probes used. The variation in intensity was found to be independent of the probe, the type of labeling, and the type of immunocytochemical detection used. Variation in intensity was not caused primarily by the immunocytochemical detection method, since directly fluorescein-labeled probes showed similar internuclear variation. Furthermore, it was found that different white blood cell types, which harbor different degrees of compactness of the nuclear chromatin, showed the same variation. The intra-nuclear variation in intensity of the ISH spots on the two chromosome homologs within one nucleus was significantly smaller (approximately 20%) than the inter-nuclear variation, probably due to more constant local hybridization conditions. Due to the relatively small intranuclear variation, copy number polymorphisms of the satellite DNA sequence on chromosome 1 could readily be quantified.(ABSTRACT TRUNCATED AT 250 WORDS)

Analog-Digital Conversion↗

An electron microscopic, immunogold analysis of glutamate and glutamine in terminals of rat spinocerebellar fibers.

A semiquantitative, electron microscopic immunocytochemical procedure based on the use of colloidal gold particles as markers was employed to analyze the subcellular distribution of glutamate and glutamine, a major glutamate precursor, in a subpopulation of spinocerebellar mossy fiber terminals. These terminals were identified by anterograde transport of a horseradish peroxidase-wheat germ agglutinin conjugate, injected in the thoracic spinal cord. Gold particles signalling glutamate-like immunoreactivity were enriched over clusters of synaptic vesicles relative to organelle-free cytoplasmic matrix, and there was a strong positive correlation between gold particle and synaptic vesicle densities (correlation coefficient 0.94). Gold particles indicating glutamine-like immunoreactivity showed a much weaker correlation with vesicle density (correlation coefficient 0.36) and were about equally concentrated over cytoplasmic matrix as over clusters of synaptic vesicles. Compared with the mossy fibers, the putative GABAergic Golgi cell terminals exhibited a lower level of glutamate-like immunoreactivity, which was very weakly correlated with the vesicle density (correlation coefficient 0.27). The level of glutamine-like immunoreactivity in the Golgi cell terminals was similar to that in mossy fibers, but much lower than that in glial cells. The anterogradely labelled mossy fiber terminals were not enriched in immunoreactivities for aspartate or GABA. These results suggest that the level and subcellular distribution of glutamate in presumed glutamatergic terminals differs from that in terminals in which glutamate only serves metabolic or precursor roles, and that these differences can be exploited in immunocytochemical studies aimed at identifying glutamate-using neurons. In contrast, glutamine immunocytochemistry does not seem to be generally useful in this regard.

Amino Acids↗

Agonist-induced [Ca2+]i waves and Ca(2+)-induced Ca2+ release in mammalian vascular smooth muscle cells.

Focal application of vasopressin to cultured vascular smooth muscle cells (A7r5 cells) elicits first a localized increase of intracellular Ca2+ concentration ([Ca2+]i) and then a wave of elevated [Ca2+]i that propagates at constant velocity throughout the cell. The cellular mechanisms of such complex spatiotemporal patterns of [Ca2+]i are of interest because they are involved fundamentally in cellular signal transduction in many types of cells. Vasopressin evoked a [Ca2+]i transient even in the absence of extracellular Ca2+, and intracellular perfusion with heparin completely blocked the response to vasopressin stimulation. Therefore the initial response to vasopressin reflects release of Ca2+ from an intracellular myo-inositol-1,4,5-trisphosphate (IP3)-sensitive Ca2+ store. We tested four hypotheses on how a localized increase in [Ca2+]i propagates as a [Ca2+]i wave throughout the entire cell: the hypotheses distinguished 1) whether IP3 or Ca2+ is the primary intracellular messenger that diffuses, and 2) whether positive feedback on the release of intracellular Ca2+ (Ca2+i) is involved (further release of Ca2+ through activation of phospholipase C by Ca2+ and increased production of IP3 or by Ca(2+)-induced Ca2+ release). The results of various experimental interventions, which included probing Ca2+i stores (heparin, caffeine, and ryanodine), were compared with predictions from mathematical models for intracellular diffusion, release, and uptake of Ca2+. We conclude that in A7r5 smooth muscle cells, which have been stimulated focally with vasopressin, Ca2+ is released initially by IP3. The localized increase in [Ca2+]i then propagates throughout the cell as a [Ca2+]i wave. Ca2+ activates its own release, through Ca(2+)-induced release of Ca2+, by diffusing to distant Ca(2+)-release sites.

Animals↗

Release of intracellular calcium and modulation of membrane currents by caffeine in bull-frog sympathetic neurones.

1. Calcium release and sequestration were studied in whole-cell voltage-clamped bull-frog sympathetic neurones by image analysis of Fura-2 signals. 2. Application of caffeine (10 mM) to cells voltage clamped at -38 mV caused a rapid increase in intracellular calcium concentration ([Ca2+]i) to a mean value of 352 +/- 33 nM, which activated an outward current. In the continued presence of caffeine the rise in [Ca2+]i slowly declined to a sustained plateau of 196 +/- 20 nM (112 nM above control levels), while the outward current rapidly decayed. Peak calcium release was highest at the edge of the cell. 3. The caffeine-evoked intracellular calcium increase was reduced by two inhibitors of calcium-induced calcium release, ryanodine and procaine. The residual non-suppressible increase in [Ca2+]i may indicate that caffeine can release calcium from two pharmacologically distinct intracellular stores. 4. Inhibition of the caffeine-evoked release of calcium by ryanodine was both concentration and 'use dependent' so that the full inhibitory effect was only observed when caffeine was applied for the second time in the presence of ryanodine. In contrast, the action of procaine did not show any 'use dependence' and unlike ryanodine was fully reversible. 5. The outward current was sensitive to blockers of the large conductance calcium-activated potassium current, Ic. Analysis of variance from this current indicated that it arose at least partly from summation of spontaneous miniature outward currents. 6. The magnitude and duration of calcium release by caffeine was dependent on the resting level of intracellular calcium and the caffeine exposure time. This, together with the pharmacology of the release, suggests that caffeine increases intracellular calcium by sensitizing calcium-induced calcium release. 7. The evoked [Ca2+]i increase was enhanced in amplitude by intracellular application of Ruthenium Red. This effect was mimicked by extracellular application of the mitochondrial uncoupler carbonyl cyanide p-trifluoromethoxyphenyl-hydrazone (FCCP) but not by internal application of FCCP or other inhibitors of mitochondrial Ca2+ uptake. This suggests that the evoked increase in [Ca2+]i is predominantly buffered by a Ruthenium Red-sensitive sequestration process which is not mitochondrial.

Animals↗

Fluorescent tetradecanoylphorbol acetate: a novel probe of phorbol ester binding domains.

Protein kinase C (PKC) has a prominent role in signal transduction of many bioactive substances. We synthesized the fluorescent derivative, phorbol-13-acetate-12-N-methyl-N-4-(N,N'-di(2-hydroxyethyl)amino)-7-n itr obenz-2-oxa-1,3-diazole-aminododecanoate (N-C12-Ac(13)) of 12-O-tetradecanoylphorbol-13-acetate (TPA) to monitor the location of phorbol ester binding sites and evaluate its potential use as a probe of PKC in viable cells. The excitation maximum wavelength of N-C12-Ac(13) is close to 488 nm, facilitating its use in argon-ion laser flow and imaging cytometry. When incubated with 100 nM N-C12-Ac(13) at 25 degrees C, P3HR-1 Burkitt lymphoma cells accumulated the dye rapidly, reaching maximum fluorescence within 25 min, 20-fold above autofluorescence. Addition of unlabeled TPA significantly decreased the fluorescence of N-C12-Ac(13) stained cells in a dose-dependent manner indicating specific displacement of the bound fluoroprobe. Competitive displacement of [3H]-phorbol-12,13-dibutyrate ([3H]-PBu2) from rat brain cytosol with N-C12-Ac(13) gave an apparent dissociation constant (Kd) of 11 nM. N-C12-Ac(13) possessed biological activity similar to TPA. Like TPA (final concentration 65 nM) N-C12-Ac(13), at a lower concentration (51 nM), induced expression of Epstein-Barr viral glycoprotein in P3HR-1 cells, differentiation of promyelocytic HL60 cells, and caused predicted changes in the mitotic cycle of histiocytic DD cells. Microspectrofluorometric images of single cells labeled with N-C12-Ac(13) showed bright fluorescence localized intracellularly and dim fluorescence in the nuclear region, consistent with dye binding mainly to cytoplasmic structures and/or organelles and being mostly excluded from the nucleus. Because of the high level of non-specific binding of N-C12-Ac(13), this probe is not ideal for visualizing PKC in intact cells, but would be a valuable fluoroprobe to investigate the kinetic properties of purified PKC. Also, knowledge gained from these studies allows us to predict structures of fluorescent phorbols likely to have less non-specific binding and, consequently, be potentially useful for monitoring PKC in viable cells.

Animals↗

Imaging neutrophil activation: analysis of the translocation and utilization of NAD(P)H-associated autofluorescence during antibody-dependent target oxidation.

Fluorescence intensified/enhanced microscopy has been used to study the metabolic activation of living human neutrophils in time-lapse sequences. The autofluorescence associated with NAD(P)H's emission band was studied within individual quiescent and stimulated cells. Excitation of NAD(P)H-associated autofluorescence was provided by a high-intensity Hg-vapor lamp. The background-subtracted autofluorescence signals were computer enhanced. In some cases the ratio image of NAD(P)H-associated autofluorescence to tetramethyl-rhodamine methyl ester (TRME) fluorescence, which was found to be uniformly distributed within neutrophils, was calculated to normalize autofluorescence intensities for cell thickness. Activation of the NADPH oxidase by phorbol myristate acetate, F-, N-formyl-methionyl-leucyl-phenylalanine (FMLP), or tumor necrosis factor (TNF) dramatically reduced autofluorescence levels. Membrane solubilization with sodium dodecyl sulfate eliminated autofluorescence. Thus, control experiments indicated that most or all of the detectable NAD(P)H-associated autofluorescence was due to NAD(P)H, consistent with previous non-microscopic studies. To understand the metabolic events surrounding the internalization and oxidative destruction of targets, we have imaged the NAD(P)H-associated autofluorescence of neutrophils and the Soret band of antibody coated target erythrocytes during cell-mediated cytotoxicity. Absorption contrast microscopy of the erythrocyte's Soret band is an especially sensitive indicator of the entry of reactive oxygen metabolites into this target's cytosol. Thus, it is possible to spectroscopically dissect and image the substrate (NADPH) and product (O2-) reactions of the NADPH oxidase in living unlabeled neutrophils. During real-time experiments at 37 degrees C, the level of NAD(P)H-associated autofluorescence surrounding phagosomes greatly increases before the disappearance of the target's Soret band. NAD(P)H-associated autofluorescence in the vicinity of phagocytosed erythrocytes is greatly diminished after target oxidation. This suggests that NAD(P)H is translocated to the vicinity of phagosomes prior to the oxidation of targets. The apparent cytosolic redistribution of NAD(P)H was confirmed by ratio imaging microscopy to control for cell thickness. We suggest that NADPH including its sources and/or carriers accumulate near phagosomes prior to target oxidation and that local NADPH molecules are consumed during target oxidation.

Antibodies↗

MR imaging with spatially variable resolution.

In some situations it may be advantageous to produce "locally focused" magnetic resonance images that have nonuniform spatial resolution matching the expected local rate of spatial variation in the object. Because such an image has fewer pixels than a conventional image with uniformly high resolution, it can be reconstructed from fewer signals, acquired in less time. This can be done by using a highly convergent representation of the image as a sum of orthonormal functions with slow (fast) spatial variation in relatively homogeneous (heterogeneous) parts of the object. Since this series is shorter than a conventional truncated Fourier series, its terms can be calculated from a subset of the usual array of phase-encoded signals. The optimal choice of these phase encodings, which are usually scattered nonuniformly in k space, results in minimization of noise in the reconstructed image. The technique is illustrated by applying it to simulated data and to data from images of phantoms.

Computer Simulation↗

The role of the digital computer in pediatric cardiology.

A digital computer system is described which allows the real-time processing of all physiological signals obtained during a heart catheterization procedure and which makes all relevant results and informations available immediately during the investigation. In addition, special electronic units and programs have been developed in our institution for the automated extraction of morphological criteria from biplane angiocardiograms. Thereby right and left ventricular volume, shape and contraction pattern can be quantitated and used to characterize the performance of the heart as muscle and pump in physical terms. Recently, complete digital processing of videoangiocardiograms has been achieved in a stroboscopic mode, each videofield in real time. Application of image enhancement, subtraction, integration and restoration techniques leads to a fundamentally improved angiocardiographic image quality for a given amount of injected contrast material. Based on eight years of experience with digital computer application in pediatric cardiology, computer technologies are considered likely to become the method of choice in the future.

Angiocardiography↗

Quantitative colour-ultrasonography by means of a computer aided simultaneous tomogram.

In this newly developed method, the ultrasonic diagnosis has become quantitative. The data will remain quantitative so far as an image storage tube is used. With the conventional storage type CRT, it is impossible to memorize the reflected echo signals of different strength levels. But with our method, it becomes possible to memorize the images according to individual levels. By the direct digitalization of the ultrasonic echo images, more information is obtained from the reflected echo signals. By processing the original information with a computer, more accurate diagnosis is possible. It is hoped and believed, that this computer aided ultrasonic examination, with single scan display in colour or black and white, will further promote ultrasonic diagnosis in future.

Color↗

Improving the reliability of pattern electroretinogram recording.

The pattern electroretinogram (PERG) is a small electrical response of the retina to a reversing checkerboard pattern, usually less than 6 microV in amplitude. Unfortunately, the PERG can be obscured by artifacts such as blinks, eye movements, poor fixation, and amplifier saturation. Amplitude criterion artifact rejection systems found on commercial signal averagers eliminate large amplitude artifacts but are insensitive to small amplitude artifacts associated with amplifier saturation. Such saturation often occurs for several recording sweeps after large amplitude signals such as eye blinks are rejected. The presence of post-saturation artifacts complicates clinical PERG analysis. In this paper we describe procedures to remove these small amplitude artifacts from the PERG. These include computer selection of inputs for averaging and use of tracings with small input numbers to approximate PERG amplitudes. These procedures greatly reduce the variability of PERG amplitudes in the normal population, making PERG amplitude a more reliable clinical measure.

Adolescent↗

On using coherence to measure distortion in hearing aids.

Coherence is a frequency-domain measure of the degree to which the output of a system is linearly related to the system input. The signal-to-distortion ratio (SDR), where the distortion term includes all nonlinear effects and noise in the system, can be computed from the coherence. The coherence estimate, however, is subject to sources of variance and bias that reduce the accuracy of the measured SDR. The origins of the variance and bias and their effects on distortion measurements are presented. New procedures for reducing the variance and bias effects are described, and the processing effectiveness is demonstrated for a simulated hearing-aid response.

Fourier Analysis↗

The measurement of blood flow waveforms from X-ray angiography. Part 2: Application to video recordings of digital subtraction angiography.

A method of measuring blood flow from X-ray angiograms recorded on cine film, by obtaining contrast mass values at numerous positions along individual vessels and at multiple instants of time, has been previously reported. In the present work it was hypothesized that the signal-to-noise limitations of recordings on video tape could be overcome by recording already-subtracted angiograms from a digital subtraction angiographic (DSA) system and that the spatial resolution of video was adequate to use a similar measurement method. Validation experiments were recorded, in which flows measured using a calibrated electromagnetic flowmeter passed through tubes of 4-7 mm diameter, during injections of 2-5 ml contrast medium. The video sequences were computer analysed and produced angiographic flow measurements agreeing with the electromagnetic flows to within 5 per cent. A case study of a clinical carotid artery DSA in a patient with secondary carcinoma metastases in the brain is described. It is concluded that accurate flow measurements can be made from DSA video recordings.

Algorithms↗

Superresolved tomography by convex projections and detector motion.

If the spatial resolution of an image-acquisition system is limited by the size of its component detector elements, then scanning may be required for the signal to be fully sampled. In such cases interpolation methods are normally applied to reproduce a uniformly sampled signal from the set of observations. Alternatively, however, this step can be treated as a restoration problem, in which case the extra measurements made accessible by detector motion may contain sufficient information to superresolve the signal, i.e., to recover information beyond the limit normally associated with finite detector size. We describe the application of this concept to the problem of constructing the projection matrix from a set of noise-corrupted tomographic measurements made by a moving detector array. In particular we focus on the case encountered in many tomographic applications in which the spatial response functions are approximately stationary with object depth. The method of projections onto convex sets is used in conjunction with an underrelaxation scheme to recover the projection matrix, from which the image is reconstructed by the standard filtered backprojection algorithm. Simulation results demonstrate that this approach applied to data acquired by a wobbling positron emission tomography system can substantially enhance the quality of the reconstructed image, even in the presence of high levels of quantum noise. The projection-matrix recovery step can be performed in a matter of seconds; thus the benefits of signal recovery are gained without a significant sacrifice in computation time.

Image Processing, Computer-Assisted↗