PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Tissue Engineering”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61Linked to original sources

Bladder wall replacement by tissue engineering and autologous keratinocytes in minipigs.

OBJECTIVE: To develop a tissue-engineered bladder wall replacement with autologous cells and a biodegradable scaffold, as whenever there is a lack of native urological tissue the bladder is reconstructed with different bowel segments, which has inevitable complications. MATERIAL AND METHODS: Skin biopsies were taken from six minipigs, and primary fibroblast and keratinocyte cell cultures established. A partial resection of the urinary bladder was reconstructed by a cell-seeded scaffold covered with completely differentiated epithelium and supported by a mucosa-free pedicled ileum graft. Each pig was assessed urodynamically and by cystography before operation and every month until explantation; the pigs were killed at 1, 2 and 3 months after augmentation. Control groups (of six pigs each) with bladder augmentation with complete or denuded ileum were used. The bladders were assessed histologically and by distensibility measurements RESULTS: The differentiated keratinocyte epithelium was still present on the reconstructed bladder wall after 3 months. The overall shrinkage rate was 6.5%. The engineered bladder wall had lower distensibility than the native one. The inflammatory reaction present initially had disappeared after 3 months. CONCLUSIONS: The implanted, tissue-engineered substitution of the bladder wall is not only a bridging graft, but also a complete reconstruction. With this model, extended bladder wall substitution seems feasible and should be investigated in further studies.

Animals↗

Nerve regeneration in a collagen-chitosan tissue-engineered skin transplanted on nude mice.

A reconstructed skin made of a collagen-chitosan sponge seeded with human fibroblasts and keratinocytes and grown in vitro for 31 days was developed for the treatment of deep and extensive burns. The aim of this study was to assess whether this tissue-engineered skin could promote nerve regeneration in vivo, since recovery of sensation is a major concern for burnt patients. The human reconstructed skin was transplanted on the back of nude mice and the growth of nerve fibres within it was assessed 40, 60, 90 and 120 days after graft. Nerve growth was monitored by confocal microscopy using immunohistochemical staining of PGP 9.5 and 150 kD neurofilament, while Schwann cell migration was observed using protein S100 expression and laminin deposition. Nerve growth was first detected 60 days after transplantation and was more abundant 90 and 120 days after graft. Linear arrangements of Schwann cells were observed in the graft as early as 40 days after graft. Nerve growth was observed along these Schwann cell extensions 60 days after transplantation. We conclude that the three-dimensional architecture of the collagen-chitosan tissue-engineered skin sponge encourages nerve growth. This result provides new perspectives to increase nerve regeneration within the tissue-engineered skin by linkage of neurotrophic factors in the sponge before transplantation.

Animals↗

Electrospun protein fibers as matrices for tissue engineering.

Electrospinning has recently emerged as a leading technique for generating biomimetic scaffolds made of synthetic and natural polymers for tissue engineering applications. In this study, we compared collagen, gelatin (denatured collagen), solubilized alpha-elastin, and, as a first, recombinant human tropoelastin as biopolymeric materials for fabricating tissue engineered scaffolds by electrospinning. In extending previous studies, we optimized the shape and size (diameter or width) of the ensuing electrospun fibers by varying important parameters of the electrospinning process, such as solute concentration and delivery rate of the polymers. Our results indicate that the average diameter of gelatin and collagen fibers could be scaled down to 200-500 nm without any beads, while the alpha-elastin and tropoelastin fibers were several microns in width. Importantly, and contrary to any hitherto reported structures of electrospun polymers, fibers composed of alpha-elastin, especially tropoelastin, exhibited "quasi-elastic" wave-like patterns at increased solution delivery rates. The periodicity of these wave-like tropoelastin fibers was partly affected by the delivery rate. Atomic force microscopy was utilized to profile the topography of individual electrospun fibers and microtensile testing was performed to measure their mechanical properties. Cell culture studies confirmed that the electrospun engineered protein scaffolds support attachment and growth of human embryonic palatal mesenchymal (HEPM) cells.

Animals↗

Mechano-active scaffold design based on microporous poly(L-lactide-co-epsilon-caprolactone) for articular cartilage tissue engineering: dependence of porosity on compression force-applied mechanical behaviors.

An essential component of functional articular cartilage tissue engineering is a mechano-active scaffold, which responds to applied compression stress and causes little permanent deformation. As the first paper of a series on mechano-active scaffold-based cartilage tissue engineering, this study focused on mechanical responses to various modes of loading of compression forces and subsequent selection of mechano-active scaffolds from the biomechanical viewpoint. Scaffolds made of elastomeric microporous poly(L-lactide-co-epsilon-caprolactone) (PLCL) with open-cell structured pores (300 approximately 500 microm) and with different porosities ranging from 71 to 86% were used. The PLCL sponges and rabbit articular cartilage tissue were subjected to compression/unloading tests (0.1 and 0.005 Hz) at 5 kPa, and stress relaxation tests at 10, 30, and 50% strain. The measurements of the maximum strain under loading and residual strain under unloading for compression tests and the maximum stress and equilibrium stress in the stress relaxation test showed that the lower the porosity, the closer the mechanical properties are to those of native cartilage tissue. Among the PLCL sponges, the sponge with 71% porosity appears to be a suitable cartilage scaffold.

Animals↗

Cell-based tissue engineering for the intervertebral disc: in vitro studies of human disc cell gene expression and matrix production within selected cell carriers.

BACKGROUND CONTEXT: Little is known about how disc cells attach, proliferate and form extracellular matrix (ECM) within carrier materials. Such information is needed to help formulate criteria for successful cell-carrier interactions in tissue engineering. PURPOSE: To compare proliferation, ECM production and gene expression in annulus cells cultured in a variety of cell carrier materials with potential application in tissue engineering of the disc. STUDY DESIGN: Human intervertebral disc cells from the annulus were used in a prospective study of proliferation, ECM production and gene expression within selected cell carriers. METHODS: Annulus cells from discs of 29 individuals were tested in collagen sponge, collagen gel, agarose, alginate or fibrin gel formulations. In situ hybridization assessed ECM gene expression of Types I and II collagen, aggrecan and chondroitin-6 sulfotransferase. Cell proliferation, cell shape, attachment and ECM production were evaluated. RESULTS: Collagen sponges provided the best microenvironment for disc cell ECM production and gene expression. Although collagen gels often could support good cell growth, such constructs did not result in either abundant ECM production or ECM gene expression, as shown by in situ hybridization. Growth and ECM production and gene expression in alginate, agarose and fibrin microenvironments were inferior. CONCLUSIONS: Tissue engineering techniques open new therapeutic possibilities for use of autologous disc cells, but fundamental questions on how these cells interact with cell carriers are unexplored. Results provide novel data on disc cell gene expression within diverse microenvironments. The collagen sponge proved to be a superior microenvironment.

Absorbable Implants↗

Extracellular matrix production by human osteoblasts cultured on biodegradable polymers applicable for tissue engineering.

The nature of the extracellular matrix (ECM) is crucial in regulating cell functions via cell-matrix interactions, cytoskeletal organization, and integrin-mediated signaling. In bone, the ECM is composed of proteins such as collagen (CO), fibronectin (FN), laminin (LM), vitronectin (VN), osteopontin (OP) and osteonectin (ON). For bone tissue engineering, the ECM should also be considered in terms of its function in mediating cell adhesion to biomaterials. This study examined ECM production, cytoskeletal organization, and adhesion of primary human osteoblastic cells on biodegradable matrices applicable for tissue engineering, namely polylactic-co-glycolic acid 50:50 (PLAGA) and polylactic acid (PLA). We hypothesized that the osteocompatible, biodegradable polymer surfaces promote the production of bone-specific ECM proteins in a manner dependent on polymer composition. We first examined whether the PLAGA and PLA matrices could support human osteoblastic cell growth by measuring cell adhesion at 3, 6 and 12h post-plating. Adhesion on PLAGA was consistently higher than on PLA throughout the duration of the experiment, and comparable to tissue culture polystyrene (TCPS). ECM components, including CO, FN, LM, ON, OP and VN, produced on the surface of the polymers were quantified by ELISA and localized by immunofluorescence staining. All of these proteins were present at significantly higher levels on PLAGA compared to PLA or TCPS surfaces. On PLAGA, OP and ON were the most abundant ECM components, followed by CO, FN, VN and LN. Immunofluorescence revealed an extracellular distribution for CO and FN, whereas OP and ON were found both intracellularly as well as extracellularly on the polymer. In addition, the actin cytoskeletal network was more extensive in osteoblasts cultured on PLAGA than on PLA or TCPS. In summary, we found that osteoblasts plated on PLAGA adhered better to the substrate, produced higher levels of ECM molecules, and showed greater cytoskeletal organization than on PLA and TCPS. We propose that this difference in ECM composition is functionally related to the enhanced cell adhesion observed on PLAGA. There is initial evidence that specific composition of the PLAGA polymer favors the ECM. Future studies will seek to optimize ECM production on these matrices for bone tissue engineering applications.

Biodegradation, Environmental↗

Physiological and cell biological aspects of perfusion culture technique employed to generate differentiated tissues for long term biomaterial testing and tissue engineering.

Optimal results in biomaterial testing and tissue engineering under in vitro conditions can only be expected when the tissue generated resembles the original tissue as closely as possible. However, most of the presently used stagnant cell culture models do not produce the necessary degree of cellular differentiation, since important morphological, physiological, and biochemical characteristics disappear, while atypical features arise. To reach a high degree of cellular differentiation and to optimize the cellular environment, an advanced culture technology allowing the regulation of differentiation on different cellular levels was developed. By the use of tissue carriers, a variety of biomaterials or individually selected scaffolds could be tested for optimal tissue development. The tissue carriers are to be placed in perfusion culture containers, which are constantly supplied with fresh medium to avoid an accumulation of harmful metabolic products. The perfusion of medium creates a constant microenvironment with serum-containing or serum-free media. By this technique, tissues could be used for biomaterial or scaffold testing either in a proliferative or in a postmitotic phase, as is observed during natural development. The present paper summarizes technical developments, physiological parameters, cell biological reactions, and theoretical considerations for an optimal tissue development in the field of perfusion culture.

Animals↗

In vivo characterisation of a novel bioresorbable poly(lactide-co-glycolide) tubular foam scaffold for tissue engineering applications.

Polylactide-co-glycolide (PLGA) foams of tubular shape were assessed for their use as soft-tissue engineering scaffolds in vitro and in vivo. Porous membranes were fabricated by a thermally induced phase separation process of PLGA solutions in dimethylcarbonate. The parameters investigated were the PLGA concentration and the casting volume of solution. Membranes produced from 5 wt/v % polymer solutions and a 6 ml casting volume of polymer solution were selected for fabricating tubes of 3 mm diameter, 20 mm length and a nominal wall thickness of 1.5 mm. Scanning electron microscopy revealed that the structure of the tubular foams consisted of radially oriented and highly interconnected pores with a large size distribution (50-300 microm). Selected tubes were implanted subcutaneously into adult male Lewis rats. Although the lumen of the tubes collapsed within one week of implantation, histological examination of the implanted scaffolds revealed that the foam tubes were well tolerated. Cellular infiltration into the foams, consisting mainly of fibrovascular tissue, was evident after two weeks and complete within eight weeks of implantation. The polymer was still evident in the scaffolds after eight weeks of implantation. The results from this study demonstrate that the PLGA tubular foams may be useful as soft-tissue engineering scaffolds with modification holding promise for the regeneration of tissues requiring a tubular shape scaffold such as intestine.

Absorbable Implants↗

Isolating a pure population of epidermal stem cells for use in tissue engineering.

Continuously renewing tissues, such as the epidermis, are maintained by stem cells that slowly proliferate and remain in the tissue for life. Although it has been known for decades that epithelial stem cells can be identified as label-retaining cells (LRCs) by long term retention of a nuclear label, isolating a pure population of stem cells has been problematic. Using a Hoechst and propidium iodide dye combination and specifically defined gating, we sorted mouse epidermal basal cells into three fractions, which we have now identified as stem, transient amplifying (TA), and non-proliferative basal cells. More than 90% of freshly isolated stem cells showed a G0/G1 cell cycle profile, while greater than 20% of the TA cells were actively dividing. Both stem and TA cells retained proliferative capacity, but the stem cells formed larger, more expandable colonies in culture. Both populations could be transduced with a retroviral vector and used to bioengineer an epidermis. However, only the epidermis from the stem cell population continued to grow and express the reporter gene for 6 months in organotypic culture. The epidermis from the transient amplifying cell fraction completely differentiated by 2 months. This novel sorting method yields pure viable epithelial stem cells that can be used to bioengineer a tissue and to test permanent recombinant gene expression.

Animals↗

Leucocyte adhesion under flow conditions: principles important in tissue engineering.

An understanding of inflammatory responses is important in a wide variety of tissue engineering applications. This review describes the current understanding of a central aspect of inflammatory responses, the adhesion of leucocytes to blood vessel walls prior to their emigration into tissues. These highly specific adhesive interactions are mediated by three main families of receptors: the selectins, integrins, and members of the immunoglobulin superfamily. Under flow conditions, the various receptors make distinct contributions to a multistep process of adhesion in which leucocytes roll, adhere firmly, and eventually transmigrate. Two examples in which these principles are important in tissue engineering research, lymphocyte adherence in transplant rejection and monocyte adherence in atherosclerosis, are discussed in the last part of the paper.

Animals↗

Tissue engineering of heart valves in vivo using bone marrow-derived cells.

In this study, we tissue-engineered heart valves in vivo using autologous bone marrow-derived cells (BMCs). Canine BMCs were differentiated into endothelial cell (EC)-like cells and myofibroblast (MF)-like cells. Decellularized porcine pulmonary valves were seeded with BMCs and implanted to abdominal aorta and pulmonary valve of bone marrow donor dogs. Histological examination of the explants identified the regeneration of valvular structures expressing CD31 and smooth muscle alpha-actin, indicating the presence of EC-like and MF-like cells in the grafts at 3 and 1 week, respectively, after implantation. Fluorescent microscopic examinations identified the presence of fluorescently labeled cells in the explants, indicating that the implanted BMCs survived and participated in the heart valve reconstitution. This study reports, for the first time, on tissue engineering of heart valve in vivo using BMCs.

Animals↗

Regulation of cellular infiltration into tissue engineering scaffolds composed of submicron diameter fibrils produced by electrospinning.

We characterize the infiltration of interstitial cells into tissue engineering scaffolds prepared with electrospun collagen, electrospun gelatin, electrospun poly(glycolic) acid (PGA), electrospun poly(lactic) acid (PLA), and an electrospun PGA/PLA co-polymer. Electrospinning conditions were optimized to produce non-woven tissue engineering scaffolds composed of individual fibrils less than 1000 nm in diameter. Each of these materials was then electrospun into a cylindrical construct with a 2 mm inside diameter with a wall thickness of 200-250 microm. Electrospun scaffolds of collagen were rapidly, and densely, infiltrated by interstitial and endothelial cells when implanted into the interstitial space of the rat vastus lateralis muscle. Functional blood vessels were evident within 7 days. In contrast, implants composed of electrospun gelatin or the bio-resorbable synthetic polymers were not infiltrated to any great extent and induced fibrosis. Our data suggests that topographical features, unique to the electrospun collagen fibril, promote cell migration and capillary formation.

Animals↗

Tissue engineering for bone regeneration using differentiated alveolar bone cells in collagen scaffolds.

Regeneration of osseous defects by a tissue-engineering approach provides a novel means of treatment utilizing cell biology, materials science, and molecular biology. In this study the concept of tissue engineering was tested with collagen type I matrices seeded with cells with osteogenic potential and implanted into sites where osseous damage had occurred. Explant cultures of cells from human alveolar bone and gingiva were established. When seeded into a three-dimensional type I collagen-based scaffold, the bone-derived cells maintained their osteoblastic phenotype as monitored by mRNA and protein levels of the bone-related proteins including bone sialoprotein, osteocalcin, osteopontin, bone morphogenetic proteins 2 and 4, and alkaline phosphatase. These in vitro-developed matrices were implanted into critical-size bone defects in skulls of immunodeficient (SCID) mice. Wound healing was monitored for up to 4 weeks. When measured by microdensitometry the bone density within defects filled with osteoblast-derived matrix was significantly higher compared with defects filled with either collagen scaffold alone or collagen scaffold impregnated with gingival fibroblasts. New bone formation was found at all the sites treated with the osteoblast-derived matrix at 28 days, whereas no obvious new bone formation was identified at the same time point in the control groups. In situ hybridization for the human-specific Alu gene sequence indicated that the newly formed bone tissue resulted from both transplanted human osteoblasts and endogenous mesenchymal stem cells. The results indicate that cells derived from human alveolar bone can be incorporated into bioengineered scaffolds and synthesize a matrix, which on implantation can induce new bone formation.

Alveolar Process↗

Tissue-engineered myocardial patch derived from extracellular matrix provides regional mechanical function.

BACKGROUND: Extracellular matrix (ECM), a tissue-engineered scaffold, recently demonstrated cardiomyocyte population after myocardial implantation. Surgical restoration of myocardium frequently uses Dacron as a myocardial patch. We hypothesized that an ECM-derived myocardial patch would provide a mechanical benefit not seen with Dacron. METHODS AND RESULTS: Using a canine model, a full thickness defect in the right ventricle was repaired with either Dacron or ECM. A third group had no surgery and determined baseline RV function. Eight weeks later, global systolic function was assessed by the preload recruitable stroke work relationship. Regional systolic function was measured by systolic area contraction (SAC), calculated by high density mechanical mapping. Tau was used to assess global diastolic function. Recoil rate and diastolic shear were used as measures of regional diastolic function. After functional data acquisition, tissue was fixed for histological evaluation. Global systolic and diastolic functions were similar at baseline and after ECM and Dacron implantation. Regional systolic function was greater in the ECM group compared with the Dacron group (SAC: 4.1+/-0.9% versus -1.8+/-1.1, P<0.05). Regional diastolic function was also greater in the ECM group (recoil rate (degrees sec(-1)): -44+/-7 versus -17+/-2, ECM versus Dacron; P<0.05). Immunohistochemical analysis revealed cardiomyocytes in the ECM implant region, a finding not seen with Dacron. CONCLUSIONS: At 8 weeks, an ECM-derived tissue-engineered myocardial patch provides regional mechanical function, likely related to cardiomyocyte population. These results are in sharp contrast to Dacron, a commonly used myocardial patch.

Absorbable Implants↗

Poly(lactic-co-glycolic acid) hollow fibre membranes for use as a tissue engineering scaffold.

Mass transfer limitations of scaffolds are currently hindering the development of 3-dimensional, clinically viable, tissue engineered constructs. We have developed a poly(lactide-co-glycolide) (PLGA) hollow fibre membrane scaffold that will provide support for cell culture, allow psuedovascularisation in vitro and provide channels for angiogenesis in vivo. We produced P(DL)LGA flat sheet membranes using 1, 4-dioxane and 1-methyl-2-pyrrolidinone (NMP) as solvents and water as the nonsolvent, and hollow fibre membranes, using NMP and water, by dry/wet- and wet-spinning. The resulting fibres had an outer diameter of 700 micro m and an inner diameter of 250 micro m with 0.2-1.0 micro m pores on the culture surface. It was shown that varying the air gap and temperature when spinning changed the morphology of the fibres. The introduction of a 50 mm air gap caused a dense skin of 5 micro m thick to form, compared to a skin of 0.5 micro m thick without an air gap. Spinning at 40 degrees C produced fibres with a more open central section in the wall that contained more, larger macrovoids compared to fibres spun at 20 degrees C. Culture of the immortalised osteogenic cell line 560pZIPv.neo (pZIP) was carried out on the P(DL)LGA flat sheets in static culture and in a P(DL)LGA hollow fibre bioreactor under counter-current flow conditions. Attachment and proliferation was statistically similar to tissue culture polystyrene on the flat sheets and was also successful in the hollow fibre bioreactor. The P(DL)LGA hollow fibres are a promising scaffold to address the size limitations currently seen in tissue engineered constructs.

Biocompatible Materials↗

Review: tissue engineering of the urinary bladder: considering structure-function relationships and the role of mechanotransduction.

A variety of conditions encountered in urology result in bladder dysfunction and the need for bioengineered tissue substitutes. Traditionally, a number of synthetic materials and natural matrices have been used in experimental and clinical settings. However, the production of functional bladder tissue replacements remains elusive. The urinary bladder sustains considerable structural deformation during its normal function and represents an ideal model tissue in which to study the effects of biomechanical simulation on tissue morphogenesis, differentiation, and function. However, the actual role of mechanical forces within the bladder has received little attention. A strategy in which in vitro-generated tissue constructs are conditioned by exposure to the same mechanical forces as they would encounter in vivo could potentially be used both in the development of functional tissue replacements and to further study the role of biomechanical signalling. The purpose of this review is to examine the role and structure-function relationship of the urinary bladder and, through consultation of the literature available on mechanotransduction and tissue engineering of alternative tissues, to determine the factors that need to be considered when biomechanically engineering a functional bladder.

Animals↗

[Biocompatibility study on tendon mixed extraction of bovine collagen for periodontal tissue engineering].

OBJECTIVE: To study the biocompatibility of tendon mixed extraction of bovine collagen (tMEBC) and to explore the feasibility of using the three-dimensional framework as periodontal tissue engineering scaffold. METHODS: After being prepared, the tMEBC were cultured with the P4-P6 of human periodontal ligament fibroblasts (HPDLFs) in vitro. Three-dimensional framework was prepared from bovine tendon. The P4-P6 of HPDLFs (with an initial density of 5 x 10(6) cells/ml) were cultured in vitro. Cell attachment and proliferation were measured by cell counting 1 day, 3, 5, and 10 days after cell seeding. Histological examination was performed with light microscope and scanning electron microscope 5 and 10 days after cell seeding. RESULTS: Porous structure, which supported the proliferation and attachment of HPDLFs, was found in tMEBC. The density of cell increased from 0.556 x 10(4) cells/ml 24 hours after cell seeding to 3.944 X 10(4) cells/mI 10 days after seeding. Light and scanning electron microscope examination indicated that HPDLFs were attached and extended on the three-dimensional scaffolds and were well embedded in the newly formed tissue matrix. CONCLUSION: tMEBC has good biocompatibility with the HPDLFs, and can be used as scaffold for cell transplantation in periodontal tissue engineering.

Animals↗

Tissue engineering of a human sized and shaped auricle using a mold.

OBJECTIVES: The creation of a tissue-engineered auricle was initially successful in an immunocompromised nude mouse model. Subsequently, an immunocompetent porcine model successfully generated a helical construct. We wished to evaluate the novel technique of using a mold to create a complete, anatomically refined auricle in a large animal model. METHODS: Mixtures of autogenous chondrocytes and biodegradable polymers were used inside a perforated, auricle shaped hollow gold mold. Three biodegradable polymers (calcium alginate, pluronic F-127, and polyglycolic acid) were used to retain the seeded chondrocytes inside the mold. These molds, along with a control, were implanted subcutaneously in the abdominal area of 10 animals (pigs and sheep). The constructs were removed after 8 to 20 weeks and were assessed by gross morphology and histology. RESULTS: All the gold implants were well tolerated by the animals. The implants using calcium alginate (n = 3) generated constructs of the exact shape and size of a normal human ear; the histology demonstrated mostly normal cartilage with some persistent alginate. The implants with pluronic F-127 (n = 3) resulted in cartilage with essentially normal histology, although leakage outside the molds and external cartilage generation was noted. Polyglycolic acid implants (n = 3) produced no useful cartilage because of an inflammatory reaction with fibrosis. The empty control mold (n = 1) demonstrated only a very small amount of fibrous tissue inside. CONCLUSION: A tissue-engineered human sized auricle of normal anatomic definition can be generated in an immunocompetent large-animal model using a mold technique. Although further refinements will be necessary, the technique appears promising for potential use in patients with microtia.

Absorbable Implants↗