Small pulmonary nodules: evaluation with repeat CT--preliminary experience.

PURPOSE: To assess the use of early repeat computed tomography (CT) of solitary pulmonary nodules to determine nodule growth. MATERIALS AND METHODS: The authors performed repeat CT of nodule phantoms to assess the accuracy of their measurement technique. They then used this technique to assess nodule growth (nine malignant, six benign) in 15 patients (nine men, six women; age range, 60-79 years; average age, 66 years) who underwent repeat CT as part of their routine clinical protocol. The final diagnosis was established with surgical resection or follow-up for more than 2 years after an indeterminate biopsy. RESULTS: Results of phantom experiments revealed that the method used to determine area change is sensitive enough to help detect nodule growth if one pixel is added around the entire circumference of a nodule. With use of standard exponential growth curves and known tumor growth rates, malignant growth could be detected in vivo within 30 days. All 15 in vivo nodules were correctly classified with early repeat CT. CONCLUSION: Preliminary experience with early repeat CT suggests that a single repeat CT scan obtained 30 days after the first scan can depict growth in most malignant tumors as small as 5 mm.

Adenocarcinoma↗

Evaluation of the solitary pulmonary nodule by positron emission tomography imaging.

Current noninvasive imaging methods are not sufficiently reliable for accurate detection of malignancy in most solitary pulmonary nodules (SPNs). Positron emission tomography (PET) using 18-fluorodeoxyglucose (FDG), showing increased FDG uptake and retention in malignant cells, has proved useful to differentiate malignant from benign tissue and could, therefore, contribute to the evaluation of the SPN. We performed a prospective study of 50 patients referred to the Pneumology Department with unclear diagnoses of SPN after conventional radiological screening. PET study was performed on each subject before an invasive procedure was proposed. Thirty three patients had a malignant nodule and 17 had a benign nodule. The mean size of malignant nodule was 3 cm (range 1.5-4.5 cm). All showed a marked increase in 18-FDG uptake. The mean size of benign nodule was 1.8 cm (range 0.5-3.5 cm). PET imaging showed the absence of 18-FDG uptake and correctly identified 15 of 17 benign nodules. There was two false-positive cases with a moderate increase in 18-FDG uptake (1 postprimary tuberculosis; and 1 anthracosilicotic nodule with nonspecific inflammation). At present, the sensitivity and specificity of the method are 100 and 88%, respectively. The positive and negative predictive values of PET imaging for SPNs are 94 and 100%, respectively. Our preliminary results demonstrate that PET-FDG imaging is a noninvasive technique, which appears highly accurate in differentiating malignant SPN from benign SPN.

Aged↗

Treatment of large cold benign thyroid nodules not eligible for surgery with percutaneous ethanol injection.

We studied the effect of percutaneous ethanol injection (PEI) in the treatment of cold, cytologically benign, large (>10 mL) thyroid nodules (CBNs) in 41 patients. The end-point of our study was to evaluate the efficacy of PEI on: 1) local symptomatology, assessed by an arbitrary symptom score; and 2) nodule volume and tracheal displacement (at ultrasonography). Follow-up ranged from 12-36 (21 +/- 9) months. Symptom score was significantly reduced (P < 0.01) after 6 months and at the end of the follow-up (2.1 +/- 0.3 vs. 0.2 +/- 0.5 and vs. 0.2 +/- 0.4). A significant (P < 0.01) nodule volume reduction was observed, without differences between solid or mixed CBNs; the reduction was 50% or more in 92.7% of patients. Neither clinical parameters nor pretreatment nodule ultrasonographic features were related to nodule reduction. Disappearance or significant reduction (>0.5 cm) of tracheal displacement was obtained in 61% and in 39% of patients, respectively. One patient experienced prethyroid region edema, pain, and mild fewer, which reversed within 1 week; and one patient had dysphonia, caused by vocal cord palsy, which reversed spontaneously within 1 month. At the end of the follow-up, nodules with just necrotic material at cytology showed a greater (P < 0.05) volume reduction than nodules with residual benign thyroid cells. Our data suggest that PEI is a safe and effective treatment of large CBNs, although sometimes serious side effects do occur.

Adolescent↗

Thyroid nodules in the population living around Semipalatinsk nuclear test site: possible implications for dose-response relationships study.

The risk of radiation-induced nodules is higher than the risk for radiation-induced cancer. Risk factors and specific modifiers of the dose-response relationship may vary among different populations and not be well recognized. Many thyroid studies have considered thyroid nodularity itself, but not specific morphological types of thyroid nodules. There are many specific types of thyroid nodules which follow a morphological classification of thyroid lesions, including some congenital and tumor-like conditions. Modern equipment and technique can help us to identify particular specific types of thyroid nodules. In this study we report some results of a clinically applicable approach to materials derived from three studies. From 1999 through 2002, we have screened 571 current residents from 4 exposed and 1 control village near the Semipalatinsk Nuclear Test Site area, who were of similar ages (<20) at the time of major radiation fallout events at the SNTS. Prevalent nodules were identified by ultrasound and fine-needle aspiration biopsy, cytopathology results. Analysis of ultrasound images and cytopathology of thyroid lesions among exposed and non-exposed population allowed us to distinguish some interesting ultrasound features for specific types of thyroid nodules. We believe that it would be interesting and possibly more informative for thyroid dosimetry studies to consider specific morphological types of thyroid nodules. We need more detailed research to clarify the feasibility of applying these findings for study of the dose-response relationship.

Adult↗

Management of thyroid nodules during pregnancy.

Guidelines for the management of thyroid nodules discovered during pregnancy have not yet been established. The authors reviewed the records of 23 patients with thyroid nodules that were first detected during pregnancy. These patients were divided into three groups according to how they were managed. Seven patients who presented early in pregnancy had their work-up completed during pregnancy, 11 patients underwent biopsy after delivery, and 5 patients were managed with observation alone. The incidence of malignancy in the series was 39%. Four patients underwent surgery during pregnancy, and 7 patients were operated on in the postpartum period. No fetal morbidity or mortality occurred. The authors recommend that fine-needle aspiration be performed in patients who present before 20 weeks of gestation with rapidly enlarging thyroid nodules, nodules associated with palpable cervical adenopathy, solid nodules larger than 2 cm, or cystic nodules larger than 4 cm. Growth of a nodule while a patient is receiving thyroid hormone suppression therapy is highly suspicious for malignancy; in this situation, consideration should be given to performing biopsy later in gestation.

Adult↗

Amyloid-like pulmonary nodules, including localized light-chain deposition: clinicopathologic analysis of three cases.

Amyloid-like pulmonary nodules have been described in patients with systemic light-chain deposition disease, but their significance in other clinical contexts is unknown. We examined biopsy specimens of amyloid-like pulmonary nodules from 3 women without systemic light-chain deposition disease. Patient 1 (aged 62 years) had multiple pulmonary nodules and underwent 2 separate lung biopsies, the first showing nodules composed of kappa light-chain deposits accompanied by low-grade lymphoplasmacytic lymphoma limited to the lung and the second, obtained after chemotherapy 9 months later, showing only residual nodules without persistent lymphoma. Patients 2 (aged 65 years) and 3 (aged 69 years) had asymptomatic solitary pulmonary nodules. In all cases, electron microscopic examination showed dense granular extracellular deposits without the fibrillary characteristics of amyloid. Amyloid-like nodules should be distinguished from nodular amyloidosis and, in some patients, might represent a localized form of light-chain deposition.

Aged↗

VATS (video-assisted thoracic surgery) of undefined pulmonary nodules. Preoperative evaluation of videoendoscopic resectability.

Peripheral undefined pulmonary nodules have become a favorable indication for the videoendoscopic approach in thoracic surgery. In our latest experience, we also successfully applied this technique in centrally located lesions of the lung. In reviewing our first 29 cases, we looked for preoperative features of videoendoscopic resectability. From March 1992 to September 1993, 29 patients underwent videothoracoscopy for undefined pulmonary nodules at our hospital. This group consisted of 17 men and 12 women (aged 25 to 77 years). Pulmonary nodules of this group of patients were defined as centrally located when close attachment to the segmental or subsegmental bronchopulmonary unit was observed and/or the distance to the visceral pleura exceeded 10 mm. Nodules that did not meet any of these criteria were hence interpreted as peripheral lesions. In the course of 21 excisions of peripheral lesions, we had to convert to open thoracotomy only once for anatomic reasons. When using the video-assisted thoracic surgery (VATS) approach for centrally located lesions, we succeeded in removing four of six. We failed only if the lesions were located in the upper lobe but could easily apply the technique for centrally located lesions in the lower lobes. In conclusion, undefined peripheral pulmonary nodules are a favorite indication for VATS. Centrally located pulmonary nodules of the lower lobes can often be managed easily by VATS, especially if the interlobar fissure extends to the stem of the pulmonary artery. Centrally located pulmonary nodules in the upper lobes may not be suitable for the VATS approach due to the special anatomic arrangement of the upper lobe segmental arteries and bronchioles.

Adult↗

The pulmonary nodule after lung transplantation. Cause and outcome.

In the immunocompromised patient, the pulmonary nodule remains a diagnostic and therapeutic challenge. We studied the incidence, cause, diagnosis, and therapy of pulmonary nodules after lung transplantation (LTx). Eight out of 64 patients (12.5%) developed pulmonary nodules after a median follow-up of 5.8 months (range, 1 to 10 months). The median age was 30.5 years (range, 21 to 62 years). Solitary pulmonary nodules (n = 2) disappeared spontaneously within 3 weeks and were suspected to be of infectious origin. The cause of multiple nodules (n = 6) was posttransplant lymphoproliferative disorder (PTLD [n = 3]), aspergillosis (n = 2), and abscesses caused by Pseudomonas aeruginosa and Staphylococcus aureus (n = 1). After an initial chest radiograph, CT with fine-needle biopsy was the most valuable diagnostic tool. In six patients, nodules resolved within 10 weeks (median, 8 weeks). Two patients, however, died of sepsis (P aeruginosa and S aureus and Aspergillus, respectively). The differential diagnosis of pulmonary nodules after LTx primarily comprises PTLD and infection (bacterial or fungal). To improve the outcome, early, aggressive treatment is mandatory; therefore, serial CT scans are strongly recommended to be part of the diagnostic armamentarium in LTx recipients.

Adult↗

A new safe and stable spiral wire needle for thoracoscopic resection of lung nodules.

BACKGROUND: To show the safety and stability of a spiral wire needle (Somatex; Rietzneuendorf, Germany) in the detection and subsequent thoracoscopic resection of subpleural and/or small nodules of the lung. METHODS: Under local anesthesia and CT control, 13 patients underwent the positioning of a spiral wire needle into the lung, with the spiral located close to or inside the nodule to be resected. Then the patients underwent video-assisted thoracoscopic surgery resection of the nodules with only two thoracoscopic accesses. RESULTS: All the nodules were identified due to the precise location of the spiral wire needle. The presence of a stable spiral wire inside the parenchyma has allowed us to put under tension the overlying parenchyma, which had previously been excluded from ventilation. The external traction on the needle facilitates the detection of the nodule and simplifies thoracoscopic resection with a stapler. With this new tool, we have always reached an adequate diagnosis and observed no cases of dislodgment of the needle during the traction maneuvers, nor cases of conversion from thoracoscopy to thoracotomy. CONCLUSIONS: Although our initial experience is limited, the use of this spiral wire needle has been shown to be extremely advantageous in identifying subpleural and/or small nodules of the lung, even sparing the classic third thoracoscopic access for their resection. The presence of a wire needle with a spiral terminal portion (which is placed firmly inside the lung parenchyma) is very useful for the thoracoscopic resection of pulmonary nodules.

Adult↗

Coexistence of an autonomously functioning thyroid nodule in a patient with Graves' disease: an unusual presentation of Marine-Lenhart syndrome.

A 44-year-old woman developed hyperthyroidism due to the coexistence of Graves' disease and an autonomously functioning thyroid nodule (AFTN). Anti-thyrotropin receptor antibody (TRAb) was strongly positive (83.2%), and a thyroid scan initially showed diffuse uptake of Tc-99m pertechnatate in both lobes and further increased uptake in accordance with the right lobe nodule. The nodule in the right lobe was histologically diagnosed as thyroid follicular adenoma. After she was maintained in a euthyroid state by treatment with Methymazole (MMI), thyroid uptake of Tc-99m in the nodule became lower and was slightly suppressed by T3 administrations probably due to its dependence on TSH. Subtotal thyroidectomy was performed and she subsequently became euthyroid with negative TBII activity. It is concluded that she had a coexisting functioning nodule with Graves' disease (Marine-Lenhart syndrome) and that the nodule changed from hot to cool along with the anti-thyroid treatment, unlike usual cases of this syndrome showing a cold nodule on the initial imaging under the hyperthyroid state. Repeated Tc-99m pertechnatate thyroid scans were helpful in evaluating the reaction of MMI and TSH in both lesions separately in the present case.

Adenoma↗

Thyroid peroxidase immunodetection as a tool to assist diagnosis of thyroid nodules on fine-needle aspiration biopsy.

In a previous work we have reported the presence in 96.9% of malignant and 4.2% of benign thyroid tumors of an immunological abnormality of the enzyme thyroid peroxidase, impeding the fixation of the anti-thyroid peroxidase monoclonal antibody termed "MoAb47". The present study has been designed to establish the ability of thyroid peroxidase immunodetection to assist the diagnosis of malignancy in fine-needle aspiration of thyroid nodules. The fixation of anti-thyroid peroxidase monoclonal antibody was investigated by immunohistochemistry on fine-needle aspirates of 150 surgically removed thyroid nodules (20 papillary carcinomas, five follicular carcinomas, 90 colloid adenomas, nine fetal adenoma, 13 atypical adenomas, five oncocytic adenomas, six Hashimoto's thyroiditis and two Graves' disease). The percentage of positive cells has been compared to the final histological diagnosis. In samples from 113/125 benign nodules 80-100% cells presented a positive immunoreaction, whereas all samples from malignant tumors yielded less than 80% positive cells. Benign nodules exhibiting less than 80% positive cells corresponded to three degenerative colloid nodules, five atypical follicular adenomas, two oncocytomas and two thyroiditis. According to results obtained in this series, with the value of 80% as the limit for discrimination between benign and high-risk nodules, the sensitivity of thyroid peroxidase staining for diagnosis of malignancy would be 100%, its specificity 90% and its overall accuracy 92%. Thyroid peroxidase staining with monoclonal antibody MoAb47 on fine-needle aspirates is a useful adjunct to conventional cytology for the investigation of patients with thyroid nodules.

Biopsy, Needle↗

Autonomously functioning thyroid nodules in a former iodine-deficient area commonly harbor gain-of-function mutations in the thyrotropin signaling pathway.

BACKGROUND: Somatic activating mutations of the thyrotropin (thyroid-stimulating hormone (TSH)) receptor (TSHR) and G(alphas) protein have been detected in solitary toxic adenomas and toxic multinodular goiters, but their role in the pathogenesis of autonomous nodules is debated. The frequency of mutations is highly variable among populations and is inversely proportional to iodine intake. DESIGN AND PATIENTS: We screened 28 clinically and histologically heterogeneous autonomous nodules from 24 Greek patients for the presence of TSHR and G(alphas) mutations. RESULTS: By direct sequencing of genomic DNA, we detected 11 somatic heterozygous gain-of-function mutations in TSHR and one in G(alphas). Forty-three percent (12 of 28) of all nodules and 57% (four of seven) of solitary toxic adenomas harbored an activating mutation. Typical adenomas and hyperplastic nodules did not differ in mutation frequency. Substitutions I568T and T632I were detected in both histological types of nodules. CONCLUSIONS: Our findings indicate that activating somatic mutations in the TSH signaling pathway are frequent in autonomous nodules in Greece. This may be due to earlier exposure of the population to iodine deficiency, which was corrected in Greece only over the past two decades. Gain-of-function mutations are shared by nodules with varying histological and clinical presentations. Thus, they may represent a common molecular mechanism underlying the pathogenesis of non-autoimmune thyroid autonomy.

Adenoma↗

[Incidence of malignant lesions in patients with clinically benign thyroid nodules: observational and prospective study in a cohort of 50 patients followed during two years].

INTRODUCTION: To study the frequency of malignant lesions in patients with clinically benign thyroid nodules and the value of the repetition of fine needle aspiration biopsy (FNAB). METHODS: Observational and prospective 2-year study in a cohort of 50 patients with clinically benign thyroid nodules. Patients were initially submitted to clinical examination, ultrasound (US) and FNAB1 patients, followed by a second FNAB and US. RESULTS: Palpation is not a good test for diagnosis and follow-up of thyroid nodules. On the other hand, the initial consideration that these patients should harbor benign lesions is a very useful parameter, since 47/50 patients (94%) did not present malignant lesions during the follow-up. FNAB1 and FNAB2 were concordant in 33/39 patients when FNAB1 was negative (85%); 11 patients were operated, 8 by suspicious FNAB and 3 due to nodule growth. We observed 2 patients with non-invasive papillary microcarcinoma and 1 patient with papillary carcinoma outside of the main nodules. CONCLUSION: there was concordance between initial clinical benign diagnosis, FNAB and the follow-up. In one case there was a papillary carcinoma. In addition, ultrasonography should be considered for all patients with suspected thyroid nodules. Finally, we demonstrated that a second cytology usually confirms the result of the first cytology in benign thyroid nodules.

Adolescent↗

Effects of reduced exposure on computed radiography: comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom.

OBJECTIVE: Radiographic exposure has been thought to have little impact on the diagnostic quality of chest computed radiography because of automatic digital control of global optical density. The objectives of this study were to compare images obtained with two different exposures in computed radiography with conventional and asymmetric screen-film images of the chest for the detection of simulated lung nodules by use of receiver operating characteristic analysis and to relate differences in observer performance to parameters of image noise measured for each receptor condition. MATERIALS AND METHODS: At 110 kVp (fixed), exposures for the two screen-film systems were those necessary to achieve adequate optical densities over the lung and mediastinal regions of an anthropomorphic phantom. The two exposures used for the computed radiographs corresponded to the exposure used for the conventional chest screen-film system and an exposure 22% lower. An anthropomorphic phantom constructed of materials matched to the muscle, lung, and bone attenuation of a muscular adult man was used. Soft-tissue-equivalent plastic nodules of various sizes were secured at multiple sites on the phantom to simulate lung nodules. The chest phantom was imaged in 50 configurations with a total of 70 superimposed nodules. The perceptual performances of five radiologists were compared by use of receiver operating characteristic analysis. The signal-to-noise ratio in the mediastinum and the coefficient of variation of noise were measured for all four image conditions by use of a step wedge technique to provide an explanation for differences in diagnostic accuracy. RESULTS: We found no significant differences in the detection of lung nodules between the two screen-film systems or between the conventional screen-film images and the standard-exposure computed radiographs. However, there was a significant decrease in nodule detection on computed radiographs obtained at a reduced exposure; this result was associated with a 21% decrease in the signal-to-noise ratio. CONCLUSION: Our results show that underexposure of computed radiographs decreases the detection of low-contrast objects such as lung nodules. Although consistent global optical density on computed radiographs is achieved over a wide range of exposures, the alterations in signal-to-noise ratio that result from underexposure can reduce the diagnostic quality of computed radiographs.

Adult↗

Ghosting of pulmonary nodules with respiratory motion: comparison of helical and conventional CT using an in vitro pediatric model.

OBJECTIVE: The study was designed to compare helical CT with varying pitch and reconstruction intervals and conventional CT for revealing pulmonary nodules in a model that simulates respiratory motion in children. MATERIALS AND METHODS: CT scans were obtained in an experimental model with one nodule (3 or 10 mm) in each scan. One-second scans were obtained at rates of 10, 20, and 30 respirations per minute using conventional CT with 4-mm collimation and table incrementation and helical CT with 4-mm collimation and either 4-mm/sec (pitch, 1:1) or 8-mm/sec (pitch, 2:1) table speed. Reconstructions were at 1-, 2-, and 4-mm intervals for scans obtained using 4-mm/sec table speed and at 1- and 4-mm intervals for scans obtained using 8-mm/sec table speed. Images were independently reviewed by three radiologists who estimated the number of nodules on each image. RESULTS: Ghosting (depiction of more than one nodule in a study) was seen in 79%, 80%, and 75% of helical CT scans obtained with a 1:1 pitch using 1-, 2-, and 4-mm reconstruction intervals, respectively. By comparison, ghosting was seen in only 54% and 58% of helical CT scans with a 2:1 pitch using 1-mm reconstruction intervals and 4-mm reconstruction intervals, respectively, and in 56% of conventional CT scans (p < .0001). A single nodule was detected on all other scans, and at least one nodule was seen on all scans. CONCLUSION: Ghosting of nodules is common in this model. Ghosting was seen less often on conventional scans and helical scans with 2:1 pitch than it was on helical scans with 1:1 pitch. Nonetheless, ghosting was seen on more than 50% of all scans with each technique.

Artifacts↗

Compound spatial sonography of the thyroid gland: evaluation of freedom from artifacts and of nodule conspicuity.

OBJECTIVE: The purpose of this study was to compare compound spatial sonography with conventional sonography of the thyroid gland with respect to freedom from sonographic artifacts and conspicuity of thyroid nodules. SUBJECTS AND METHODS: A prospective study was performed on 50 thyroid nodules (in 43 patients). Each nodule was examined using compound spatial sonography and conventional sonography. The sonographic techniques were then compared with respect to freedom from sonographic artifacts and thyroid nodule conspicuity. RESULTS: For freedom from artifacts, compound spatial sonography was superior in 45 cases (90%), and conventional sonography was superior in five cases (10%). Statistical analysis showed that compound spatial sonography was superior to conventional sonography for freedom from artifacts (p < 0.001). For thyroid nodule conspicuity, compound spatial sonography was superior in 37 cases (74%), and conventional sonography was superior in 13 cases (26%). Statistical analysis showed that compound spatial sonography was superior to conventional sonography for thyroid nodule conspicuity (p < 0.001). CONCLUSION: Compound spatial sonography of the thyroid displays greater freedom from artifacts and better nodule conspicuity than does conventional sonography.

Adult↗

Usefulness of an artificial neural network for differentiating benign from malignant pulmonary nodules on high-resolution CT: evaluation with receiver operating characteristic analysis.

OBJECTIVE: The purpose of our study was to use an artificial neural network to differentiate benign from malignant pulmonary nodules on high-resolution CT findings and to evaluate the effect of artificial neural network output on the performance of radiologists using receiver operating characteristic analysis. MATERIALS AND METHODS: We selected 155 cases with pulmonary nodules less than 3 cm (99 malignant nodules and 56 benign nodules). An artificial neural network was used to distinguish benign from malignant nodules on the basis of seven clinical parameters and 16 radiologic findings that were extracted by attending radiologists using subjective rating scales. In the observer test, 12 radiologists (four attending radiologists, four radiology fellows, and four radiology residents) were presented with high-resolution CT images, first without and then with the artificial neural network output. Observer performance was evaluated by means of receiver operating characteristic analysis using a continuous rating scale. RESULTS: The artificial neural network showed a high performance in differentiating benign from malignant pulmonary nodules (A(z) = 0.951). The average A(z) value for all radiologists increased by a statistically significant level, from 0.831 to 0.959, with the use of the artificial neural network output. CONCLUSION: Our computerized scheme using the artificial neural network can improve the diagnostic accuracy of radiologists who are differentiating benign from malignant pulmonary nodules on high-resolution CT.

Adult↗

New classification of small pulmonary nodules by margin characteristics on high-resolution CT.

PURPOSE: To analyze margin characteristics of pulmonary nodules on high-resolution CT (HRCT) in order to improve imaging diagnoses. MATERIAL AND METHODS: HRCT images of 193 pulmonary nodules of less than 30 mm maximum diameter (113 primary cancers, 15 metastatic cancers, 55 inflammatory nodules, and 10 benign tumors) were reviewed and classified as to 6 types of margins: round, lobulated, densely spiculated, ragged, tentacle or polygonal and halo. The relationships of these imaging types to the diagnoses, the underlying pathological features, mainly those of tumor growth patterns in 93 neoplasms, and the pathological characteristics of 14 inflammatory nodules were investigated. RESULTS: Eighty-two percent of the lobulated, 97% of the densely spiculated, 93% of the ragged and 100% of the halo nodules were malignant. Eighty percent of the tentacle or polygonal nodules were inflammatory and 66% of the round ones were benign. The 6 types differed statistically as to the nature of the benignity/malignancy (p<0.001). Pathologically, in case of neoplasms, most of the 6 types had a relationship to a particular tumor growth pattern. CONCLUSION: This HRCT classification method is useful for determining the nature of small pulmonary nodules and reflects the underlying pathological characteristics.