PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Elastic Modulus”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62Linked to original sources

A comparison between the use of dynamic mechanical analysis and oscillatory shear rheometry for the characterisation of hydrogels.

In this study the use of dynamic mechanical analysis (DMA) for the mechanical characterisation of pharmaceutical hydrogels was evaluated. DMA was used in two different modes, the "controlled force" and the "multi-strain" (MS). The results obtained on dextran methacrylate hydrogels of various compositions were compared to those obtained using an oscillatory shear rheometer. The best agreement was found between the MS-DMA and the rheometer results. The moduli measured in MS-DMA were extrapolated towards zero compression to obtain the modulus of the hydrogels. This procedure resulted in good agreement with the data obtained with the rheometer. Hydrogels were analysed after swelling to equilibrium with both methods, DMA and rheology. A scaling between the elastic modulus (G') and the equilibrium swollen polymer volume fraction (v(2,s)) could be found, although the best correlation between G' and v(2,s) was obtained with the rheometer.

Hydrogels↗

The effect of bathing solution tonicity on resting tension in frog muscle fibers.

Resting tension and short-range elastic properties of isolated twitch muscle fibers of the frog have been studied while bathed by solutions of different tonicities. Resting tension in isotonic solution at 2.3-microm sarcomere spacing averaged 0.46 mN.mm(-2) and was proportional to the fiber cross-section area. Hypertonic solutions, containing 0.1-0.5 mM tetracaine to block contracture tension, caused a small sustained tension increase, which was proportional to the fiber cross-section area and which reached 0.9 mN.mm(-2) at two times normal tonicity (2T). Further increases in tonicity caused little increase in tension. Hypotonic solutions decreased tension. Thus, tension at 2.3 microm is a continuous, direct function of tonicity. The dependence of tension on tonicity lessened at greater sarcomere lengths. At 3.2 microm either a very small rise or, in some fibers, a fall in tension resulted from an increase in tonicity. Hypertonic solutions also decreased the tension of extended sarcolemma preparations. In constant-speed stretch experiments the elastic modulus, calculated from the initial part of the stretch response, rose steeply with tonicity over the whole range investigated (1-2.5T). The results show that tension and stiffness of the short-range elastic component do not increase in parallel in hypertonic solutions.

Animals↗

[Modeling of elastic deformation and vascular resistance of arterial and venous vasa vasorum].

As in most living tissues, a network of nutritional vessels, the so-called vasa vasorum, irrigates the vessel wall under physiological conditions. An alteration or obstruction of this network can induce severe lesions. Most normal arteries and veins are irrigated by a vasa vasorum network located mainly in the adventice. They essentially supply oxygen to the outer layers of the vascular wall, the inner layer being mainly oxygenated by direct diffusion from bloodstream. Vasa vasorum responds to vasomotor stimuli and can even regress, e.g., after vascularization of arterial grafts. Their pathophysiological importance for arteries is now established. Indeed, it is known that an infusion disorder or vasa vasorum alteration may induce or promote early atherosclerotic lesions, fibrodysplasia or even media necrosis. From a mechanical point of view, and considering the three layers as a unique material, the vessel shows non-isotropic linear elastic and incompressible (v = 0.5) behaviour in the case of minimal or moderate deformation. But in the case of major deformation, the vessel displays a non-linear behaviour. The interaction between vasa vasorum supply and the mechanical properties of the arterial vascular wall can promote the occurrence of aneurysms as soon as vasa vasorum irrigation decreases. Some authors have hypothesized that these microvessels could fulfil the same function in the venous wall. It appears also that microcirculation flow rates are lower in varicose veins than in healthy ones and that partial oxygen pressure, already low in a healthy vein media, is even lower in a varicose vein. All these facts underline the importance of supply by the vasa vasorum network and its determining role in maintaining vascular wall integrity. In addition, the influence of vessel non-linear properties and their pathological changes on microcirculation would partially explain media necrosis in arteries and veins. Studying vascular wall deformation under the influence of intraluminal pressure revealed that an initially circular vasa vasorum rapidly takes on an elliptical shape which results more from crosswise circumferential stretching of the wall than from radial crushing. This induces increased hydraulic resistance. Thus permanent overpressure reduces vascular wall irrigation. Once the wall has been devascularized, it will loose its elasticity, harden and retain its maximal deformation. A vicious circle is then created. This phenomenon, noticeable in arteries, could be more serious in veins because their walls are thinner and elasticity modulus is lower. For example, for an intraluminal overpressure of 100 mmHg in an artery and 10 mmHg in a vein the ellipticity of the vasa vasorum becomes 1.2 and 3 respectively. Based on the hypothesis of a linear elastic behaviour and a periodical intraluminal overpressure, the ratio of the two axis of an arterial vasa vasorum B/A varies from 1.13 to 1.28 for Pa = 100 + 30 sin (2 pi t) mmHg, and from 1.24 to 1.44 for Pa = 160 + 40 sin (2 pi t) mmHg. In this case, the ratio of hydraulic resistances R(ellipse)/R(circle) changes little (less than 1, the ratio of the axis varies from 1.1 to 2.6 for Pa = 5 + 5 sin (2 pi t) mmHg) and from 1.8 to 5.8 for Pa = 10 + 5 sin (2 pi t) mmHg). Thus the ratio of hydraulic resistance varies from 1 to 1.5 and from 1.2 to 2.8 respectively. In practice Young's modulus increases in parallel with luminal pressure by limiting vascular wall and vasa vasorum deformation. If we consider the non-linear behaviour of the vessel wall and suppose the same conditions of intraluminal pressure, the ratio of the axis of the venous vasa vasorum in a hypertensive patient varies from 1.6 to 2.6 (instead of 1.8 to 5.8 in the case of linear model). This ratio is higher than that of the healthy subject which is less than 1.7. So the vascular structure in physiological conditions itself reacts to the pressure increases which may jeopardize vasa vasorum irrigation by delaying mural transfor

Animals↗

Mechanical properties of a reversible, DNA-crosslinked polyacrylamide hydrogel.

Mechanical properties of a polyacrylamide gel with reversible DNA crosslinks are presented. In this system, three DNA strands replace traditional chemical crosslinkers. In contrast to thermoset chemically crosslinked polyacrylamide, the new hydrogel is thermoreversible; crosslink dissociation without the addition of heat is also feasible by introducing a specific removal DNA strand. This hydrogel is characterized by a critical crosslink concentration at which gelation occurs. Below the critical point, a characteristic temperature exists at which a transition in viscosity is observed. Both temperature-dependent viscosity and elastic modulus of the material are functions of crosslink density.

Acrylic Resins↗

In vivo measurements of the viscoelasticity of the human vitreous humor.

A point of source of light against a dark background is perceived by the human retina as a point image enhanced by off-axis points (rays if the source is polychromatic) of light scattered from objects along the optic axis. As a consequence of movement of the vitreous humor, scattering centers imbedded there impart of this scattering pattern a corresponding movement. A method has been devised to give the vitreous humor reproducible initial conditions and to record the observed relaxation of the scattering pattern to its new rest position. The vitreous humor is found to be overdamped, and the heretofore unreported shear elastic modulus has been determined. A striking gravitational effect is revealed by comparing observations along a horizontal optic axis with ones along a vertical optic axis. For the former, gravitational torque is found to dominate the elastic torque. The reason nature has developed a slow-responding gravitational sensor in the vitreous humor is not clear.

Elasticity↗

Anomalous elasticity of nematic and critically soft elastomers.

Uniaxial elastomers are characterized by five elastic constants. If their elastic modulus C5 describing the energy of shear strains in planes containing the anisotropy axis vanishes, they are said to be soft. In spatial dimensions d less than or equal to 3, soft elastomers exhibit anomalous elasticity with certain length-scale-dependent bending moduli that diverge and shear moduli that vanish at large length scales. Using renormalized field theory at d=3 and to first order in epsilon=3-d, we calculate critical exponents and other properties characterizing the anomalous elasticity of two soft systems: (i) nematic elastomers in which softness is a manifestation of a Goldstone mode induced by the spontaneous symmetry breaking associated with a transition from an isotropic state to a nematic state, and (ii) a particular version of what we call a critically soft elastomer in which C(5)=0 corresponds to a critical point terminating the stability regime of a uniaxial elastomer with C5>0.

Journal Article↗

The structural and cellular viability in cryopreserved rabbit carotid arteries.

OBJECTIVE: We investigated the histological and mechanical changes in addition to viable cellular recovery in cryopreserved blood vessels. MATERIALS AND METHODS: Rabbit carotids were cryopreserved in a cryoprotective medium containing 1.5 M of 1,2-propanediol (PD) and then were thawed slowly in an ice bag that had been precooled in liquid nitrogen. Fresh carotids were used as the control. The fresh and freeze-thawed arteries were cultured for the growth of vascular smooth muscle cells (VSMCs). The freeze-thawed arterial tissues were perfused in vitro for 6, 12, or 24 h, respectively, to assess the integrity of carotid walls and the mechanical properties. RESULTS: The results showed that it took almost the same time (24 approximately 36 h) for the VSMCs of the PD-cryopreserved arteries to regenerate as those from the fresh arteries. Their growing speeds also were similar. On the contrary, Me2SO-cryopreserved (1.5 M) arteries were unable to regenerate VSMCs in culture. After freeze-thawing, the mechanical properties decreased significantly (P < 0.003 for elastic modulus and P < 0.001 for fracture strength). After in vitro perfusion of the freeze-thawed carotid arteries, all of the survived endothelial cells fell off, and some of the VSMCs denaturalized or necrosed. The internal elastic fibers and collagen showed various degrees of cracking. The mechanical properties were decreased (P < 0.05). CONCLUSION: Our findings demonstrate that the PD-containing cryoprotective medium can preserve regenerative capacity of VSMCs, which makes it a useful technique for viable VSMC recovery. However, the freeze-thawing process and the in vitro perfusion caused serious disruption in the arterial mechanical properties, rendering the cryopreserved blood vessels less useful for vessel reconstruction.

Animals↗

Spatial and structural dependence of mechanical properties of porcine intervertebral disc.

Structure-function relationship of natural tissues is crucial to design a device mimicking the structures present in human body. For this purpose, to provide guidelines to design an intervertebral disc (IVD) substitute, in this study the influence of the spatial location and structural components on the mechanical properties of porcine IVD was investigated. Local compressive stiffness (LCS) was measured on the overall disc, also constrained between the two adjacent vertebrae: the dependence on the lumbar position was evaluated. The compliance values in the anterior position (A) were higher than both in the central posterior (CP) and in the lateral-posterior (RP, LP) locations. The values of Young's Modulus (74.67+/-6.03 MPa) and compression break load (1.36x10(4)+/-0.09x10(4)N) of the disc were also evaluated by distributed compression test. The NP rheological behavior was typical of weak-gels, with elastic modulus G' always higher than viscous modulus G" all over the frequency range investigated (G' and G" respectively equal to 320 and 85 Pa at 1 Hz) and with the moduli trends were almost parallel to each other.

Journal Article↗

Functional similarities in the mechanical design of the aorta in lower vertebrates and mammals.

The mechanical properties of the aorta from the toad Bufo marinus, the lizard Gekko gecko and the garter snake Thamnophis radix were compared to those of the rat, by inflation of vessel segments in vitro. The arteries of the lower vertebrates, like those of mammals, were compliant, highly resilient, and non-linearly elastic. The elastic modulus of the artery wall was similar in the lower vertebrates and mammals, at their respective mean physiological pressures. We conclude that the aorta in each of these animals is suitably designed to function effectively as an elastic pulse smoothing component in the circulation; differences in the pressure wave transmission characteristics of lower vertebrates and mammals do not result from dissimilarities in arterial elastic properties, but from substantial differences in heart rate of these two groups.

Animals↗

The effect of base materials with different elastic moduli on the fracture loads of machinable ceramic inlays.

This study investigated the effect of two base materials with different elastic moduli (F2000 and Vitrebond) on the fracture load of machinable ceramic inlays. Standardized MOD cavities were prepared in 18 human maxillary first or second premolars. The teeth were randomly assigned to three groups of six premolars each; Group 1 (control: no base); Group 2 (base with a polyacid-modified resin composite: F2000); Group 3 (base with a resin-modified glass-ionomer cement: Vitrebond). The inlays were fabricated from Vitablocs Mark II using a Cerec II machine. After the inlays were cemented with Tetric Ceram and the Syntac adhesive system, using the Ultrasonic Insertion Technique (USI), they were stored in distilled water at 37 degrees C for 24 hours prior to fracture testing in a universal testing machine using a crosshead speed of 0.5 mm/minute. The static transverse elastic moduli of base materials were measured using a three-point bending test. The mean fracture loads and standard deviations of the Cerec inlays in Groups 1, 2 and 3 were 1.15 +/- 0.39 KN, 1.13 +/- 0.36 KN and 0.58 +/- 0.11 KN, respectively. Statistical analysis showed that the mean fracture load of Group 3 was significantly lower than that of Groups 1 and 2 (p < .05). There was no significant difference in fracture load between Groups 1 and 2. The means and standard deviations of the elastic moduli of F2000 and Vitrebond were 15.63 +/- 0.32 and 2.16 +/- 0.55 GPa, respectively. The results indicated that the fracture load increased significantly as the elastic modulus of a base material increased.

Analysis of Variance↗

The effects of embedding material, loading rate and magnitude, and penetration depth in nanoindentation of trabecular bone.

Understanding the pathophysiology of metabolic bone disease requires the characterization of both the quantity as well as the quality (i.e., microarchitecture and material properties) of the bone tissue. Nanoindentation provides a powerful yet simple method to measure the nano/micro mechanical properties of bone, but no uniform testing methodology exists. This study examines the effects of embedding materials, rate and depth of indentation, and storage time on the measured modulus. Nineteen trabecular bone samples were evaluated for the study. Although there was an 8-fold increase in the stiffness of the soft to hard epoxy, bone tissue modulus was not affected by the stiffness of the embedding materials, but hardness was affected by both the embedding material modulus, for example from 0.70 +/- 0.20 GPa (ME(low)) to 0.45 +/- 0.21 GPa (ME(Med)) (p < 0.01), and viscosity (p < 0.01). No significant differences were found with regard to the tested rates and depths of indentation for either elastic modulus or hardness. The tissue modulus tested at the 6-month time point was significantly greater in comparison with that tested at 0 or 3 months (p < 0.01). The hardness, however, did not significantly change over the span of 6 months. The results show that while nanoindentation is powerful, it is particularly sensitive to certain testing variables.

Animals↗

Noninvasive assessment of mechanical properties of peripheral arteries.

An ultrasound examination was used to noninvasively determine the changes in mechanical properties associated with age for the common carotid, brachial, popliteal, femoral, and tibial arteries. Forty-two normal male subjects, ranging in age from 8 to 60 years of age, were examined. The subjects were placed in one of three age groups: less than 29 years of age, 29 to 38, and greater than 38. Mechanical properties including percentage variation in diameter, pressure-strain, and circumferential elastic modulus were determined from changes in wall thickness and pulse pressure. Percentage variation in diameter (PVD) was seen to decrease with age for all arteries except the brachial, which remained relatively constant. Pressure-strain (Ep) and circumferential elastic moduli (Eo) were seen to increase with age in all arteries except the brachial, which remained relatively constant. Values of Ep and Eo were normalized into a stiffness index by dividing by the value found for the brachial artery. Stiffness indexes for the common carotid and femoral arteries were observed to increase more rapidly with age than the indexes obtained for the popliteal and tibial arteries. It is proposed that the stiffness index and changes in this parameter that occur with age may be useful in noninvasively assessing the progression of atherosclerosis.

Adolescent↗

[Imaging of elasticity distribution in arterial wall by transcutaneous ultrasound and electronic staining].

Knowledge of the physical properties of atherosclerotic plaque is essential when evaluating its vulnerability in a clinical setting. Such knowledge, however, is still difficult to obtain with the various approaches developed to date. This paper describes a novel noninvasive method (phased tracking method) for measuring minute change in thickness of each of the multiple layers of the arterial wall during one cardiac cycle. Such minute change in thickness less than 100 microns of the arterial wall cannot be measured by conventional ultrasound B-mode or M-mode images. A method for evaluation of the regional elastic modulus in the circumference direction, E theta, from the resultant change in wall thickness is also described. This method was applied to in vivo experiments in subjects with hyperlipemia and normal subjects. The spatial distribution of the regional elastic moduli, E theta, was evaluated for the carotid atherosclerotic plaques. By comparing the pathological findings with the distribution of elasticity, average elasticity of lipid and that of a mixture of smooth muscle and collagen fiber could be determined. Based on these reference parameters, each point was statistically categorized as lipid, mixture, or other. Thus, the plaque was electronically stained using transcutaneous ultrasound. By applying this method to the common carotid arteries, the presence of thin collagen fiber was clarified along the arterial axis for normal subjects, while soft inclusion of lipid was found for every plaque in subjects with hyperlipidemia. This novel method offers potential as a diagnostic technique for detection of plaque vulnerability with high spatial resolution.

Arteriosclerosis↗

Comparison of dosage-dependent effects of beta-aminopropionitrile, sodium fluoride, and hydrocortisone on selected physical properties of cortical bone.

BAPN, sodium fluoride, and hydrocortisone are reported to induce altered mineralization states. Three separate sets of experiments, one set for each agent, were performed using male New Zealand white rabbits. In each experiment the rabbits were segregated into groups, each fed a specified weight-determined dose for 13 weeks and then sacrificed. Compact bone from the left femur and tibia were tested for density, composition, sonic velocity, longitudinal elastic modulus, equatorial diffraction spacing of mineralized collagen, diaphyseal cross-sectional area, and relative load stress. beta-Aminopropionitrile (BAPN) induced monotonic degradation of all properties at all dose levels, corresponding to the decreasing density with dosage level. The elastic moduli show a decrease; the equatorial diffraction spacing of the collagen increases. The cross-sectioned diaphysis resembled woven bone. The variability in properties increased with dosage. The total cross-sectional area for a given weight increased, implying that the decreased elastic properties were compensated for by a larger area to support the weight. There was a slight increase in average density and other properties for fluoride-treated rabbits, peaking at 20 mg/kg BW/day. For higher dosages the properties are degraded and the values were much lower at high fluoride dosages than for BAPN. There was no peak for the equatorial diffraction spacing, which increased with dosage. It is inferred that the fluorosed apatite is denser than normal apatitic mineral and therefore has a smaller specific volume. A greater weight fraction of fluorosed mineral has a smaller volume fraction than the equivalent normal apatitic mineral. The bone sections look more normal, except for the porosis. The total cross-sectional area decreases when the bone density increases and then increases as the density falls, again implying that the area required to support body weight depends on the magnitude of the elastic moduli. There was a small change in some of the properties of the bones of the hydrocortisone-treated rabbits, but the effects on others were undetectable within the uncertainty of the procedures. There was no change in the cross-sectional areas of the diaphyses.

Aminopropionitrile↗

Compliance calibration for fracture testing of equine cortical bone.

An experimental compliance calibration method for measuring crack length in fracture toughness tests of cortical bone was developed. Calibration tests were conducted on twenty compact type fracture specimens machined from the mid-diaphysis of five pairs of equine third metacarpal bones. Specimens were oriented for crack propagation in a direction transverse to the longitudinal axis of the bone. Specimen compliance was determined from the load vs. crack opening displacement record over a range of crack lengths from 0.48 to 0.75 times the specimen width. The results demonstrate that the compliance calibration method developed for isotropic materials can be used to determine crack length in bone, which is transversely isotropic. However, specimens from lateral and dorsal regions exhibited significantly different compliance calibrations even after differences in elastic modulus were taken into account in the normalized compliance.

Animals↗

The effects of cyclic stress on dental polymethylmethacrylate. II. Flexural fatigue.

Mechanisms of fatigue failure in polymers and the aims of fatigue testing have been examined, and factors affecting testing summarized. In the light of available work in several fields, parameters have been suggested for realistic flexural fatigue testing of denture base resins. A testing machine has been developed, with which the changes in properties of acrylic resin after fatigue in different environments can be studied. These changes developed gradually after 10(4) cycles and were related to the development of bulk crazing rather than to thermal effects. The amount of decay in the elastic modulus was not such that the material could have been said to have "failed".

Chemical Phenomena↗

[Fundamental studies of elastic impression materials (part III). Viscoelastic properties from start of mix for alginate impression materials (author's transl)].

The viscoelastic properties during setting of commercial alginate impression materials vary considerably from one product to another. In order to obtain an acculate impression, it is important to understand these differences in viscoelastic properties. The purpose of this investigation is to develop the method of measuring viscoelastic properties during setting and to determine precise setting characteristic of commercial alginate impression materials. The materials used in this investigation were mixed according to the manufacturer's recommendation at a temperature of 23 +/- 0.5 degrees C and transferred after 60 sec from start of mixing to the testing instrument in an air cabinet at 32 +/- 0.5 degrees C and allowed to set. The mixing time for materials was 30 seconds. The apparatus used in this investigation is the oscillating rheometer modifiied by Inoue and Wilson (1977). The working times of impression materials procured at retail in alginate paste were shorter than those of alginate Impression materials in powder. Alginate, Jeltrate (regular), Xantalgin (normal) and Zelgan had long working time. In case of these materials, the variation of elastic modulus during the time of working was small markedly. All other materials used in this investigation, with the exception of Alginate, indicated a considerable increase torsional shear modulus after the setting time determined by the method of British standard.

Alginates↗

New surface-hardened, low-modulus, corrosion-resistant Ti-13Nb-13Zr alloy for total hip arthroplasty.

To optimize the performance of total hip replacement, scientists and clinicians are seeking new materials and noncemented, press-fit designs that can improve load transfer to the bone and reduce the incidence of loosening and thigh pain. Currently used Co-Cr-Mo alloy has a relatively high elastic modulus (E = 227 GPa), which limits its ability to transfer load to the surrounding bone in the proximal calcar region. Thus to improve load transfer, designs are considered with less cross-sectional area to increase flexibility, but at the expense of fit and fill, and thus stability of the implant within the bone. Should stem loosening occur, the stem stresses may exceed the relatively low fatigue strength of the Co-Cr-Mo alloy and lead to stem breakage. To improve these conditions, lower modulus Ti-6Al-4V alloy (E = 115 GPa) is being used. More recently, a new lower-modulus (E = 79 GPa) Ti-13Nb-13Zr alloy has been developed which does not contain any elemental constituents associated with adverse cell response (i.e., Co, Cr, Mo, Ni, Fe, Al, V), and which possesses comparable or superior strength and toughness to existing Ti-6Al-4V alloy. The carefully selected Nb and Zr constituents improve bone biocompatibility and corrosion resistance compared to that of currently used implant metals. Additionally, a unique diffusion hardening (DH) treatment can be conducted during the age-hardening process of this near-beta alloy to produce a hardened surface with abrasion resistance superior to that of Co-Cr-Mo alloy. This also provides an improvement in the micro-fretting tendencies that may occur within femoral head-neck taper regions and modular interfaces of other implant designs. The present study describes the metallurgy and mechanical properties of this unique low modulus Ti-13Nb-13Zr alloy, and the heat treatments used to obtain the high strength, corrosion resistance, and surface hardening that renders this biocompatible alloy well-suited for press fit hip replacement applications. Because of the relatively lower beta transus (735 degrees C), this alloy is also much easier to net shape forge into more complex stem designs.

Alloys↗