PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “FLUORESCENCE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62Linked to original sources

Cytosine detection by a fluorescein-labeled probe containing base-discriminating fluorescent nucleobase.

We report on a new method for the detection of a base at a specific site in a DNA sequence by monitoring the fluorescence emission of fluorescein. To achieve this goal, we developed a new base-discriminating fluorescent (BDF) nucleobase, naphthodeazaadenine ((ND)A). The fluorescence spectrum of the duplex possessing a cytosine base as a complementary base of (ND)A showed a fluorescence peak at 383 nm when using an excitation wavelength of 350 nm. When the complementary base of (ND)A was one of the other bases, the fluorescence intensity was very low. The fluorescence emission spectrum of (ND)A overlapped with the fluorescence excitation spectrum of fluorescein in the wavelength range of 400-500 nm. Thus, we designed FRET-BDF probes containing (ND)A as the FRET donor and fluorescein as the acceptor. The interaction of these two fluorophores, which are separated by defined base pairs, allowed an efficient energy transfer that resulted in a dominant fluorescence emission of fluorescein at 520 nm when using an excitation wavelength of 350 nm. Fluorescence emission from FRET-BDF probes was observed only when the complementary base of (ND)A is C, thus achieving a clear distinction of a C base on the complementary DNA strand. However, the general utility of our method is limited due to the quenching of the (ND)A fluorescence by a G/C base pair flanking (ND)A.

Base Pairing↗

Sex-related differences in the handling of fluorescent ovalbumin by the proximal tubule of the rat kidney.

Sex-dependent protein handling in the rat renal tubular system was studied both qualitatively and quantitatively using the method of direct fluorescent protein tracing. The protein tracer, fluorescent ovalbumin, was synthesized by conjugating hen ovalbumin with fluorescein isothiocyanate (FITC), and the fluorescence characteristics of fluoresceinthiocarbamyl (FTC)-ovalbumin conjugates with different degrees of labelling were studied. Heavily labelled tracer was intravenously injected into male and female rats, and both kidneys were perfused; the right kidney was then homogenized and used for quantitative fluorometric measurements, while the left kidney was perfusion fixed and prepared for fluorescence microscopy. The tubular reabsorption of fluorescent ovalbumin was studied 4 min and 10 min after the injection of different doses (1.4, 7.0 and 14.0 mg/kg body weight) of the tracer, and the tubular catabolism was investigated in animals killed 60 and 120 min after the injection. Fluorescence microscopy demonstrated that, in both sexes and regardless of the dose administered and the time after injection, specifically fluorescent protein or its degradation products was only present in the epithelial cells of the proximal tubule. With regard to sex-dependent differences in protein handling, fluorometry indicated that at 4 min (7.0 mg) and at 10 min (all doses) after injection, female animals had reabsorbed more fluorescent protein than males. With regard to the catabolic phase, both the fluorescence microscopy and the fluorometric results showed that the female rats had degraded the fluorescent tracer at a significantly higher rate than males. The results are discussed in connection with sex-dependent proteinuria in rats.

Animals↗

Infrared fluorescence microscopy of stained tissues: principles and technic.

Infrared photomicrography was used extensively from 1927 to the 1940's, but received little attention during the last decades. However, studies of infrared fluorescence of stained sections could not be found in the accessible literature. Ramsley (1968) published quantitative data on infrared fluorescence of approximately 250 dyes bound to textile fibers. The intensity of infrared fluorescence of many dyes varied widely with the substrate. It was therefore deemed of interest to determine whether or not similar differences in infrared fluorescence may occur when dyes are bound to histochemically distinct tissue structures. Myofibrils and collagens stained with triarylmethane dyes were chosen as test objects. Kodak infrared cut-off filter No. 301 and Wratten filter #16 were used as exciter filters to remove infrared and UV-blue and the light of a xenon lamp. Wratten filter #70 and #89B were employed as barrier filters. Infrared radiation was recorded with Kodak Ektachrome infrared film. To facilitate correlation of infrared fluorescence patterns with visible images, tissues were photographed also with conventional color film. Stained myofibrils, e.g. in myoepithelium, smooth and striated muscle emitted strong infrared fluorescence; collagen showed little or no fluorescence. Barrier filter Wratten #70 permitted simultaneous demonstration of infrared fluorescence and of non-fluorescent structures and thus facilitated histopathological studies. Preliminary findings indicate decrease or loss of infrared fluorescence of stained muscle fibers in various lesions, e.g. myocardial infarction, Duchenne-type muscular dystrophy.

Connective Tissue↗

Evidence that a copper-metallothionein complex is responsible for fluorescence in acid-secreting cells of the Drosophila stomach.

Copper cells were originally identified in Drosophila midgut epithelium by their striking orange fluorescence in copper-fed larvae. Here, we examined copper cell fluorescence in light of the previous observations that (1) a similar fluorescent signal in yeast is produced by a complex between copper and metallothionein, and (2) metallothionein is expressed constitutively in the copper cell region and inducibly in other regions of the Drosophila midgut. Pulse-feeding experiments with 1 mM CuCl2 revealed that fluorescence appeared rapidly in copper cells (<5 min) and slowly in other cells of the midgut (days), suggesting a constitutive cofactor in the former and an inducible cofactor in the latter. Fluorescence was also detected in Drosophila S2 tissue culture cells after induction of metallothionein synthesis by addition of CuCl2 to the growth medium. Thus, fluorescence coincided spatially and temporally with the expression of metallothionein. Fluorescence was also linked to the acid-secreting activity of copper cells. Fluorescence was not observed when acid secretion was inhibited by a mutation in the alpha spectrin gene and acidification was blocked in copper-fed wild-type larvae. However, acidification was restored after a 1-day chase period in which the fluorescent signal became sequestered within a vesicular compartment. We therefore conclude that copper cell fluorescence is most probably attributable to a cytoplasmic copper-metallothionein complex, suggesting an unanticipated role for metallothionein in acid-secreting cells.

Animals↗

Effect of polystyrene microsphere surface to fluorescence lifetime under two-photon excitation.

Molecular assays such as immunoassays are often performed using solid carriers and fluorescent labels. In such an assay format a question can be raised on how much the fluorescence of the label is influenced by the bio-affinity binding events and the solid carrier surface. Since changes in fluorescence intensity as labels bind to surfaces are notoriously difficult to quantify other approaches are preferred. A good indicator, independent of the fluorescence intensity of the label, is the fluorescence lifetime of the marker fluorophore. Changes in fluorescence lifetime reliably indicate the presence of dynamic quenching, energy transfer or other de-excitation processes. A microsphere based assay system is studied under two-photon excitation. Changes in fluorescence lifetime are studied as labeled protein conjugates bind on microsphere surfaces--both direct on the surface and with a few nanometer distance from the surface. Fluorescence signal is measured from individual polystyrene microspheres and the fluorescence lifetime histogram is simultaneously recorded. The results indicate that self-quenching and quenching by the polystyrene surface are both present in such a system. However, the effect of the surface can be avoided by increasing the distance between the surface and the label. Typical distances achieved by a standard sandwich type of assay, are already sufficient to overcome the surface induced quenching in fluorescence detection.

Animals↗

Anthroyl stearate as a fluorescent probe of chloroplast membranes.

1. A reversible light-induced enhancement of the fluorescence of a "hydrophobic fluorophore", 12-(9-anthroyl)-stearic acid (anthroyl stearate), is observed with chloroplasts supporting phenazine methosulfate, cyclic or 1,1'-ethylene-2,2'-dipyridylium dibromide (Diquat) pseudo-cyclic electron flow; no fluorescence change is observed when methyl viologen or ferricyanide are used as electron acceptors. The stearic acid moiety of anthroyl stearate is important for its localization and fluorescence response in the thylakoid membrane, since structural analogs of anthroyl stearate lacking this group do not show the same response. 2. This effect is decreased under phosphorylating conditions (presence of ADP, Pi, Mg2+), and completely inhibited by the uncoupler of phosphorylation NH4Cl(5-10mM), as well as the ionophores nigericin and gramicidin-D (both at 5 - 10(-8)M). The MgCl2 concentration dependence of the anthroyl stearate enhancement effect is identical to that previously observed for cyclic photophosphorylation, as well as for the formation of a "high energy intermediate". The anthroyl stearate fluorescence enhancement is inhibited by increasing concentrations of ionophores in parallel with the decrease in ATP synthesis, but is essentially unaffected by specific inhibitors (Dio-9 and phlorizin) of photophosphorylation; thus, it appears that anthroyl stearate monitors a component of the "high energy state" of the thylakoid membrane rather than a terminal phosphorylation step. 3. The light-induced anthroyl stearate fluorescence enhancement is suggested to monitor a proton gradient in the energized chloroplast because (a) similar enhancement can be produced by sudden injection of hydrogen ions in a solution of anthroyl stearate; (b) when the proton gradient is dissipated by gramicidin or nigericin light-induced anthroyl stearate fllorescence is eliminated; (c) when the proton gradient is dissipated by tetraphenylboron, light-induced anthroyl stearate fluorescence decreases, and (d) light-induced anthroyl stearate fluorescence change as a function of pH is qualitatively similar to that observed with other probes for a proton gradient (e.g. 9-aminoacridine). Furthermore, anthroyl stearate does not monitor H+ uptake per se because (a) the pH dependence of H+ transport is different from that of the anthroyl stearate fluorescence change, and (b) tetraphenylboron, which does not inhibit H+ uptake, reduces anthroyl stearate fluorescence. Thus, anthroyl stearate appears to be a useful probe of a proton gradient supported by phenazine methosulfate of Diquat catalyzed electron flow and is the first "non-amine" fluorescence probe utilized for this purpose in chloroplasts.

Anthracenes↗

Endocytosis of liposomes by macrophages: binding, acidification and leakage of liposomes monitored by a new fluorescence assay.

The interaction of liposomes with macrophage cells was monitored by a new fluorescence method (Hong, K., Straubinger, R.M. and Papahadjopoulos, D., J. Cell Biol. 103 (1986) 56a) that allows for the simultaneous monitoring of binding, endocytosis, acidification and leakage. Profound differences in uptake, cell surface-induced leakage and leakage subsequent to endocytosis were measured in liposomes of varying composition. Pyranine (1-hydroxypyrene-3,6,8-trisulfonic acid, HPTS), a highly fluorescent, water-soluble, pH sensitive dye, was encapsulated at high concentration into the lumen of large unilamellar vesicles. HPTS exhibits two major fluorescence excitation maxima (403 and 450 nm) which have a complementary pH dependence in the range 5-9: the peak at 403 nm is maximal at low pH values while the peak at 450 nm is maximal at high pH values. The intra- and extracellular distribution of liposomes and their approximate pH was observed by fluorescence microscopy using appropriate excitation and barrier filters. The uptake of liposomal contents by cells and their subsequent exposure to acidified endosomes or secondary lysosomes was monitored by spectrofluorometry via alterations in the fluorescence excitation maxima. The concentration of dye associated with cells was determined by measuring fluorescence at a pH independent point (413 nm). The average pH of cell-associated dye was determined by normalizing peak fluorescence intensities (403 nm and 450 nm) to fluorescence at 413 nm and comparing these ratios to a standard curve. HPTS-containing liposomes bound to and were acidified by a cultured murine macrophage cell line (J774) with a t1/2 of 15-20 min. The acidification of liposomes exhibited biphasic kinetics and 50-80% of the liposomes reached an average pH lower than 6 within 2 h. A liposomal lipid marker exhibited a rate of uptake similar to HPTS, however the lipid component selectively accumulated in the cell; after an initial rapid release of liposome contents, 2.5-fold more lipid marker than liposomal contents remained associated with the cells after 5 h. Coating haptenated liposomes with antibody protected liposomes from the initial release. The leakage of liposomal contents was monitored by co-encapsulating HPTS and p-xylene-bis-pyridinium bromide, a fluorescence quencher, into liposomes. The time course of dilution of liposome contents, detected as an increase in HPTS fluorescence, was coincident with the acidification of HPTS. The rate and extent of uptake of neutral and negatively charged liposomes was similar; however, liposomes opsonized with antibody were incorporated at a higher rate (2.9-fold) and to a greater extent (3.4-fold).(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Enhanced ALA-induced fluorescence in hyperparathyroidism.

INTRODUCTION: Intraoperative localization of parathyroid glands can be challenging especially in minimally invasive surgery. Fluorescence diagnosis using the photosensitizer aminolevulinic acid (ALA) has been described to identify normal parathyroid glands during experimental bilateral neck exploration. The present study evaluated fluorescence differences between hyperplastic and normal parathyroid glands as a precondition for a clinical application of the technique. MATERIALS AND METHODS: Polycystic kidney disease (PKD) rats with hyperparathyroidism due to hyperplastic parathyroid glands and Wistar rats with normal parathyroid glands were photosensitized by peritoneal lavage with ALA solution. After surgical exposure of thyroid and parathyroid glands the operative site was observed under blue light conditions using the d-light system to assess fluorescence characteristics of each tissue. Fluorescence intensities of parathyroid glands and surrounding thyroid tissue were measured by spectrometry. Parathyroid hormone in serum of the rats was determined by enzyme-linked immunosorbent assay (ELISA). RESULTS: Observation of the exposed thyroid site showed a subjectively stronger red fluorescence of the parathyroid glands in the PKD rats in comparison to the Wistar rats, whereas thyroid tissue appeared equally fluorescent. In the PKD animals, spectrometric fluorescence intensity was 10 times higher in the parathyroid glands than in the thyroid gland, whereas in the Wistar rats the ratio was 3.2:1. Fluorescence intensity in the parathyroid glands was more than twice in the PKD rats than in the Wistar rats, however slightly lower in the thyroid tissue. ELISA confirmed the pathophysiological change of a hyperparathyroidism with significantly increased serum levels of parathyroid hormone in the PKD rats. DISCUSSION: Hyperparathyroidism enhances ALA-induced fluorescence of the parathyroid glands. A combined surgical fluorescence strategy may justify a unilateral, minimally invasive approach in selected patients and serve to improve the capability of the surgeon to safely and efficiently manage parathyroid diseases.

Aminolevulinic Acid↗

Characterisation of the fluorescence from freshwater, planktonic bacteria.

Amino acid-like fluorescence has been used as an indicator of biological activity in wastewater effluent and in natural waters, and can be detected using fluorescence spectroscopy. Little or no work has been able to state conclusively that these so called 'amino acid-like' fluorophores are associated with proteins present as a result of bacterial activity. This work aims to ascertain whether bacteria are one possible cause of these 'amino acid-like' peaks observed in natural waters. In addition, fluorescence derived solely from one bacterial source was determined as a function of the growth time and temperature. The bacterium Pseudomonas aeruginosa was isolated from the urban River Tame, Birmingham, UK, and planktonic bacteria were grown in sterile, sealed glass jars, in 100 ml growth media. Bacteria were grown at 11, 25 and 37 degrees C, over a maximum of 10 days. A 3D Excitation-Emission Matrix (EEM) plot was generated from fluorescence analysis of the samples. Both tryptophan and tyrosine-like fluorescence, resembling that observed in natural and waste waters, was observed in these samples, indicating that observed fluorescence signals from aquatic systems in the literature were of biotic origin. Significant differences in fluorescence signals were obtained from planktonic cells grown at different temperatures. At 25 and 37 degrees C, cells were found to produce predominantly tryptophan-like fluorescence, with some tyrosine-like fluorescence also detected. A further unknown fluorophore was also detected (emission wavelength of approximately 460 nm, with three excitation centres at 225, 260 and 390 nm), likely to be a bacterially produced metabolite. At 11 degrees C, a more environmentally realistic temperature in temperate environments, quantitative and qualitative differences were observed in fluorescence signals when compared with the higher temperatures, indicating that laboratory observations conducted at higher temperatures may not be easily used to interpret environmental processes.

Bacterial Proteins↗

Fluorescence and photosensitization of experimental endometriosis in the rat after systemic 5-aminolevulinic acid administration: a potential new approach to the diagnosis and treatment of endometriosis.

OBJECTIVE: Our purpose was to evaluate and compare the conversion of 5-aminolevulinic acid into the endogenous photosensitizer protoporphyrin IX in experimentally induced endometriosis and in other normal tissues in a rat model. STUDY DESIGN: Fluorescence of experimental endometriotic lesions, uterus, peritoneum, bowel mesentery, bladder, eye, skin, and skeletal muscle was assessed 3 hours after either intravenous, oral, or intrauterine administration of 5-aminolevulinic acid with use of spectrophotofluorometry. In another experiment the fluorescence of surgically induced endometriosis and adjacent normal peritoneum was evaluated every 15 minutes after 5-aminolevulinic acid administration to assess the time course of protoporphyrin IX production. RESULTS: In the rat endometriosis model intralesional and systemic 5-aminolevulinic acid produced fluorescence within implants showing viable endometrial cells. Treatment with 5-aminolevulinic acid produced low-intensity fluorescence in peritoneum, bowel mesentery, and eye. Relatively intense fluorescence was seen in skin, bladder, and uterus. No fluorescence was observed in skeletal muscle. The intensity of fluorescence varied with the dosage and route of administration of 5-aminolevulinic acid. Fluorescence intensity of protoporphyrin IX was significantly greater in implants than in adjacent normal peritoneum between 2 and 4 hours after treatment. CONCLUSIONS: Protoporphyrin IX fluorescence in experimentally induced endometriosis lesions after intravenous and oral delivery of 5-aminolevulinic acid was significantly greater than the fluorescence detected in adjacent normal peritoneum.

Aminolevulinic Acid↗

Resolution of the Photosystem I and Photosystem II contributions to chlorophyll fluorescence of intact leaves at room temperature.

Green leaves illuminated with photosynthetically active light emit red fluorescence, whose time-dependent intensity variations reflect photosynthetic electron transport (the Kautsky effect). Usually, fluorescence variations are discussed by considering only the contribution of PSII-associated chlorophyll a, although it is known that the fluorescence of PSI-associated chlorophyll a also contributes to the total fluorescence [Aust. J. Plant Physiol. 22 (1995) 131]. Because the fluorescence emitted by each photosystem cannot be measured separately by selecting the emission wavelength in in vivo conditions, the contribution of PSI to total fluorescence at room temperature is still in ambiguity. By using a diode array detector, we measured fluorescence emission spectra corresponding to the minimal (F(O)) and maximal (F(M)) fluorescence states. We showed that the different shapes of these spectra were mainly due to a higher contribution of PSI chlorophylls in the F(O) spectrum. By exciting PSI preferentially, we recorded a reference PSI emission spectrum in the near far-red region. From the F(O) and F(M) spectra and from this PSI reference spectrum, we derived specific PSI and PSII emission spectra in both the F(O) and F(M) states. This enables to estimate true value of the relative variable fluorescence of PSII, which was underestimated in previous works. Accurate separation of PSI-PSII fluorescence emission spectra will also enable further investigations of the distribution of excitation energy between PSI and PSII under in vivo conditions.

Chlorophyll↗

Fluorescence measurements of fusion between human erythrocytes induced by poly(ethylene glycol).

The kinetics of poly(ethylene glycol) (PEG)-induced fusion between intact human erythrocytes was continuously monitored by a fluorescence lipid mixing method, utilizing the dequenching of the fluorescence probe, 1-oleoyl-2-[12-[(7-nitro-2,1,3-benzoxadiazol-4-yl)amino]dodecanoyl ] phosphatidylcholine (C12-NBD-PC). The steady-state fluorescence intensity was detected from the surface of cells in a monolayer on an alcian blue-coated glass coverslip. The relief of fluorescence self-quenching after fusion between C12-NBD-PC labeled and unlabeled intact erythrocytes was measured. The extent of fluorescence dequenching was normalized based on the measured concentration of probes in membranes, the projected partial dequenching due both to dilution by intercellular fusion, and the dilution between the inner and outer leaflets of membranes (flip-flop). There was no significant increase in fluorescence intensity during PEG treatment of 5 min, at 4 degrees C. Intensity increased immediately after the dilution of PEG, and reached saturation in 30 min. The efficiency of fusion increased with the increasing of PEG concentrations. Only 4% enhancement of saturated relative fluorescence intensity was detected in 25 wt% PEG-induced cell fusion; 23% enhancement in 30 wt%; and 66% enhancement in 35 wt%. The transfer of fluorescent probes between membrane bilayer leaflets (flip-flop) was also monitored during the fusion process. Flip-flop was monitored in confluent monolayers as well as in isolated cells. There was no significant spontaneous flip-flop within 30 min of dilution. The relative fluorescence intensity enhancement contributed by the dilution of probes between fused labeled and unlabeled cells (at a 1:1 ratio) was found to account for only 39% of the observed final dequenching, whereas the contribution by flip-flop associated with cell fusion was found to account for 9%, and flip-flop without fusion contributed approximately 18%. A portion of the flip-flop is a consequence of hemolysis. Therefore, fluorescence dequenching measurements of fusion of whole cells must be interpreted with caution.

Biophysical Phenomena↗

Fluorescence cytology of the urinary bladder.

OBJECTIVES: To assess, on the basis of the tumor-associated fluorescence characteristics of 5-aminolevulinic acid-induced fluorescence endoscopy, the value of fluorescence microscopy and compare it with standard cytologic techniques. 5-Aminolevulinic acid-induced fluorescence endoscopy has proved to be a valuable detection method with a high sensitivity for the endoscopic diagnosis of bladder cancer. METHODS: We instilled 1.5 g of 5-aminolevulinic acid, dissolved in 50 mL of 5.7% sodium monohydrogen phosphate, into the urinary bladder of 162 patients with suspected transitional cell carcinoma 2 to 3 hours before endoscopy. A lavage solution was obtained for urinary cytology and for fluorescence cytology. The sediments were evaluated for tumor cells. RESULTS: Transitional cells suspicious for tumor demonstrated the red 5-aminolevulinic acid-induced protoporphyrin IX fluorescence under the microscope. Fluorescence cytology identified 50 of 58 histologically confirmed neoplastic lesions (G1, 14 of 17; G2, 12 of 14; G3, 15 of 16; and carcinoma in situ, 9 of 11). With urinary cytology, we identified 46 of 58 histologically confirmed tumor lesions (G1, 9 of 17; G2, 12 of 14; G3, 15 of 16; and carcinoma in situ, 10 of 11). The sensitivity of fluorescence cytology was 86% and that of urinary cytology 79%. The specificity of fluorescence cytology was 75% and that of urinary cytology 88%. CONCLUSIONS: Fluorescence cytology promises to be an effective procedure for the diagnosis of bladder cancer, especially in highly differentiated and flat premalignant tumor lesions. Automated analysis for an objective and a reproducible result appears possible.

Adolescent↗

Estimation of lipid peroxidation of live cells using a fluorescent probe, diphenyl-1-pyrenylphosphine.

Diphenyl-1-pyrenylphosphine (DPPP), which reacts with lipid hydroperoxides stoichiometrically to yield fluorescent product DPPP oxide, was used as a fluorescent probe for lipid peroxidation in live cells. DPPP was successfully incorporated into U937 cells. Incorporation of DPPP into the cell membrane was confirmed by fluorescence microscopy. Reaction of DPPP with hydroperoxides was examined by monitoring increase in fluorescence intensity of the cell. It was found that lipid-soluble hydroperoxides such as methyl linoleate hydroperoxide preferably react with DPPP, whereas hydrogen peroxide did not react with DPPP located in the membrane. Linear correlation between increase in fluorescence intensity and the amount of methyl linoleate hydroperoxide applied to the cell was observed. DPPP gave little effect on cell proliferation, cell viability or cell morphology for at least 3 d. DPPP oxide, fluorescent product of DPPP, was quite stable in the membrane of living cells for at least 2 d. Fluorescence of DPPP-labeled cells was measured after treating with diethylmaleate (DEM), or 2,2'-Azobis(2-amidinopropane) dihydrochloride (AAPH), or culturing with low serum content. These reagents and culture condition induced dose- and/or time-dependent increase in fluorescence. Addition of vitamin E effectively suppressed increase in fluorescence. When DPPP-labeled cells and DCFH-DA-labeled cells were treated with NO, H(2)O(2), AAPH, and DEM to compare the formation of hydoperoxides in the membrane and cytosol, distinct patterns of peroxide formation were observed. These results indicate that fluorescent probe DPPP is eligible for estimation of lipid peroxidation proceeding in the membrane of live cells, and use of this probe is especially advantageous in long-term peroxidation of the cell.

Cell Membrane↗

Basic study of an agent for reinforcement of near-infrared fluorescence on tumor tissue.

BACKGROUND AND AIMS: An indocyanine green derivative (ICG-sulfo-OSu) and agents for reinforcement of infrared fluorescence, which can be used as an infrared fluorescent labeling substance suitable for detection of microlesions by an IR fluorescence endoscope, have been developed. The study aims were to confirm the ability of a reinforcement agent, as well as imaging processing, to intensify fluorescence from the labeled antibody on immunohistochemical staining. SUBJECTS AND METHODS: ICG-sulfo-OSu-labeled MUC1 antibody and an IR fluorescence imaging system were employed in the present study. Paraffin sections of gastric cancer were stained with anti-MUC1 antibody by the avidin-biotinylated peroxidase complex method. Among the positive specimens, three cases were used for IR imaging analysis. Octylglucoside was used as a reinforcement agent. RESULTS: The incubation of paraffin sections with ICG-sulfo-OSu-labeled MUC1 antibody resulted in positive staining of the tumor sites by an IR fluorescence imaging system, and the intensity of fluorescence was increased depending on the concentration of octylglucoside and grade of imaging processing. CONCLUSION: A reinforcement agent, and image processing, intensify a labeled antibody excitable by infrared fluorescence in tumor sections and can generate a strong enough fluorescent signal to detect small cancers when examined with an infrared fluorescence endoscope.

Adenocarcinoma↗

Quantitative analysis of the effects of intrathylakoid pH and xanthophyll cycle pigments on chlorophyll a fluorescence lifetime distributions and intensity in thylakoids.

The xanthophyll cycle-dependent dissipation of excitation energy in higher plants is one of the most important regulatory and photoprotective mechanisms in photosynthesis. Using parallel time-resolved and pulse-amplitude modulation fluorometry, we studied the influence of the intrathylakoid pH and the xanthophyll cycle carotenoids on the PSII chlorophyll (Chl) a fluorescence yield in thylakoids of Arabidopsis, spinach, and barley. Increases in concentrations of dithiothreitol in thylakoids, which have a trans-thylakoid membrane pH gradient and are known to have decreased conversion of violaxanthin (V) to zeaxanthin (Z), lead to (1) decreases in the fractional intensity of the approximately 0.5 ns Chl a fluorescence lifetime (tau) distribution component and simultaneous increases in a 1.6-1.8 ns fluorescence component and (2) increases in the maximal fluorescence intensity. These effects disappear when the pH gradient is eliminated by the addition of nigericin. To quantitatively explain these results, we present a new mathematical model that describes the simultaneous effects of the chloroplast trans-thylakoid membrane pH gradient and xanthophyll cycle pigments on the PSII Chl a fluorescence tau distributions and intensity. The model assumes that (1) there exists a specific binding site for Z (or antheraxanthin, A) among or in an inner antenna complex (primarily CP29), (2) this binding site is activated by a low intrathylakoid pH (pK approximately 4.5) that increases the affinity for Z (or A), (3) about one Z or A molecule binds to the activated site, and (4) this binding effectively "switches" the fluorescence tau distribution of the PSII unit to a state with a decreased fluorescence tau and emission intensity (a "dimmer switch" concept). This binding is suggested to cause the formation of an exciton trap with a rapid intrinsic rate constant of heat dissipation. Statistical analysis of the data yields an equilibrium association constant, Ka, that ranges from 0.7 to 3.4 per PSII for the protonated/activated binding site for Z (or A). The model explains (1) the relative fraction of the approximately 0.5 ns fluorescence component as a function of both Z and A concentration and intrathylakoid pH, (2) the dependence of the ratio of F'm/Fm on the fraction of the 0.5 ns fluorescence tau component (where F'm and Fm are maximal fluorescence intensities in the presence and the absence of a pH gradient), and (3) the dependence of the ratio of F'm/Fm on the concentration of Z and A and the intrathylakoid pH.

Carotenoids↗

Differences in the binding of fluorescent concanavalin A to the surface membrane of normal and transformed cells.

The binding of fluorescein-conjugated Concanavalin A to the cell surface has been studied in normal and transformed cells in interphase and mitosis. Binding to the cell surface was in the form of an incomplete ring of fluorescence, and the binding was inhibited by alpha-methyl-D-mannopyranoside. All the cells were fluorescent when treated with 25-250 mug/ml of fluorescent Concanavalin A. With 10 mug, the cells were all fluorescent after 30 min of binding, but after 0.5-5 min with 10 mug or 30 min with 1 or 2.5 mug, transformed interphase cells showed a higher percentage of cells with surface fluorescence than did normal interphase cells. Trypsinized normal and transformed interphase cells showed the same fluorescence. Binding with 2.5 mug at 4 degrees instead of at 24 degrees , gave a higher percentage of fluorescent cells with trypsinized than with untrypsinized transformed cells. Mitotic normal cells were similar to transformed interphase cells, whereas mitotic transformed cells were intermediate between normal and transformed interphase cells. The results indicate that the use of low concentrations of fluorescent Concanavalin A can show differences in surface fluorescence between normal and transformed, interphase and mitotic, and trypsinized and untrypsinized cells. It is suggested that the observed differences in fluorescence can be explained by differences in affinity of the lectin binding sites and/or differences in the clustering of sites.

Animals↗

Overcoming compound interference in fluorescence polarization-based kinase assays using far-red tracers.

Kinase-mediated phosphorylation of proteins is critical to the regulation of many biological processes, including cell growth, apoptosis, and differentiation. Because of the central role that kinases play in processes that can lead to disease states, the targeting of kinases with small-molecule inhibitors is a validated strategy for therapeutic intervention. Classic methods for assaying kinases include nonhomogenous enzyme-linked immunosorbent assays or scintillation-based formats using [gamma-(32)P]ATP. However, homogenous fluorescence-based assays have gained in popularity in recent years due to decreased costs in reagent usage through miniaturization, increased throughput, and avoidance of regulatory costs associated with the use of radiation. Whereas the readout signal from a nonhomogenous or radioactive assay is largely impervious to interferences from matrix components (such as library compounds), all homogenous fluorescent assay formats are subject to such interferences. Interference from intrinsically fluorescent compounds or from scattered light due to precipitated compounds can interfere with assays that depend on a fluorescence intensity (or fluorescence quenching), fluorescence resonance energy transfer, or fluorescence polarization-based readout. Because these interfering factors show a greater effect at lower wavelengths, one strategy to overcome such interferences is to develop fluorescent assays using longer wavelength (red-shifted) fluorescent probes. In this article, we describe the PanVera PolarScreen far-red fluorescence polarization assay format, which mitigates assay interference from autofluorescent compounds or scattered light through the use of a far-red tracer. The tracer shows substantially less interference from light scatter or autofluorescent library compounds than do fluorescein-based tracers, and gives rise to a larger assay window than the popular far-red fluorophore Cy5.

Cyclic AMP-Dependent Protein Kinases↗