PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62Linked to original sources

Active micromixer for microfluidic systems using lead-zirconate-titanate (PZT)-generated ultrasonic vibration.

A micromixer using direct ultrasonic vibration is first reported in this paper. The ultrasonic vibration was induced by a bulk lead-zirconate-titanate (PZT; 5 x 4 x 0.2 mm), which was excited by a 48 kHz square wave at 150 V (peak-to-peak). Liquids were mixed in a chamber (6 x 6 x 0.06 mm) with an oscillating diaphragm driven by the PZT. The oscillating diaphragm was in the size of 6 x 6 x 0.15 mm. Ethanol and water were used to test the mixing effectiveness. The laminar flows of ethanol (115 microL/min) and water (100 microL/min) were mixed effectively when the PZT was excited. The entire process was recorded using a video camera.

Animals↗

An enhanced microfluidic chip coupled to an electrospray Qstar mass spectrometer for protein identification.

The combination of microfabricated fluidic systems (muFAB) and electrospray mass spectrometers (ESI-MS) will provide multiplexed and integrated analytical systems for proteins and other biomolecules. Implementation of this novel approach requires the development of robust and user-friendly muFAB devices. Here, we present new approaches that improve the robustness, user friendliness and performance of muFAB devices coupled to MS. First, we present the development of a convenient mount to connect a muFAB device to the ESI-MS and the incorporation of filters in the reservoirs and exit of the muFAB. This mount facilitates interfacing and significantly reduces the chemical noise observed by the MS. Furthermore, we demonstrate improvements in sample handling and delivery by using either a nonaqueous electrolyte or a cationic coating on the surfaces in the muFAB device and transfer capillary. These improvements are applied to protein analysis by continuous infusion of proteolytic digests.

Animals↗

Microfluidic chips for clinical and forensic analysis.

This review gives an overview of developments in the field of microchip analysis for clinical diagnostic and forensic applications. The approach chosen to review the literature is different from that in most microchip reviews to date, in that the information is presented in terms of analytes tested rather than microchip method. Analyte categories for which examples are presented include (i) drugs (quality control, seizures) and explosives residues, (ii) drugs and endogenous small molecules and ions in biofluids, (iii) proteins and peptides, and (iv) analysis of nucleic acids and oligonucleotides. Few cases of microchip analysis of physiological samples or other "real-world" matrices were found. However, many of the examples presented have potential application for these samples, especially with ongoing parallel developments involving integration of sample pretreatment onto chips and the use of fluid propulsion mechanisms other than electrokinetic pumping.

Antibodies↗

A dynamically modified microfluidic poly(dimethylsiloxane) chip with electrochemical detection for biological analysis.

Separation and direct detection of amino acids, glucose and peptide in a 3.1 cm separation channel made of poly(dimethylsiloxane) (PDMS) with end-column amperometric detection at a copper microdisk electrode was developed. This system is the integration of a normal sized working electrode with electrochemical detection on a PDMS microfabricated device. The PDMS channels dynamically modified by 2-morpholinoethanesulfonic acid (MES) show less adsorption and more enhanced efficiency than that of unmodified ones when applied to separations of these biological molecules. The migration time is less than 100 s and the reproducibility of migration time is satisfactory with relative standard deviation (RSD) of 2.8% in 19 successive injections. The limits of detection of arginine (Arg), glucose, and methionine-glycine (Met-Gly) are estimated to be 2.0, 8.5, and 64.0 microM at S/N = 3, approximately 0.5-16.0 fmol, respectively. Variances influencing the separation efficiency and amperometric response, including injection, separation voltage, detection potential, or concentration of buffer and additive, are assessed and optimized.

Alkanesulfonic Acids↗

Practical integration of polymerase chain reaction amplification and electrophoretic analysis in microfluidic devices for genetic analysis.

An integrated system of a silicon-based microfabricated polymerase chain reaction (microPCR) chamber and microfabricated electrophoretic glass chips have been developed. The PCR chamber was made of silicon and had aluminum heaters and temperature sensors integrated on the glass anodically bonded cover. Temperature uniformity in the reaction chamber was +/-0.3 degrees C using an improved novel "joint-heating" scheme. Thermal cycling was digitally controlled with a temperature accuracy of +/- 0.2 degrees C. Small operating volumes together with high thermal conductivity of silicon made the device well suited to rapid cycling; 16 s/cycle were demonstrated. For analysis of the PCR products, the chamber output was transferred to the glass microchip by pressure. Analysis time of PCR amplified genomic DNA was obtained in the microchip in less than 180 s. The analysis procedure employed was reproducible, simple and practical by using viscous sieving solutions of hydroxypropylmethylcellulose and dynamically coated microchip channels with poly(vinylpyrrolidone). DNA fragments that differ in size by 18 base pairs (bp) were resolved. Analysis of genomic male and female amplified DNA by microPCR was achieved in microchip, and application of the integrated microPCR-microchip for the identification of bird sex was tested. Genomic DNA samples from several bird species such as pigeon and chicken were analyzed. Hence, the system could be used as well to determine the sex of avian species.

Animals↗

Low-voltage electroosmosis pump for stand-alone microfluidics devices.

Two types of low-voltage electroosmosis pumps were developed using microfabrication technology for usage in handy or stand-alone applications of the micrototal analysis systems (micro-TAS) and the lab-on-a-chip. This was done by making a thin (< 1 microm) region in the flow path and by only applying voltages near this thin region using electrodes inserted into the flow path. The inserted electrodes must be free from bubble formation and be gas-tight in order to avoid pressure leakage. For these electrodes, Ag/AgCl or a gel salt bridge was used. For patterning the gel on the chip, a hydrophilic photopolymerization gel and a photolithographic technique were optimized for producing a gel with higher electric conductivity and higher mechanical strength. For high flow rate application, wide (33.2 mm) and thin (400 nm) pumping channels were compacted into a 1 mm x 6 mm area by folding. This pump achieves an 800 Pa static pressure and a flow of 415 nL/min at 10 V. For high-pressure application, a pump was designed with the thin and thick regions in series and positive and negative electrodes were inserted between them alternatively. This pump could increase the pumping pressure without increasing the supply voltage. A pump with 10-stage connections generated a pressure of 25 kPa at 10 V.

Acrylic Resins↗

Analysis of amino acids and proteins using a poly(methyl methacrylate) microfluidic system.

Plastic microchips are very promising analytical devices for the high-speed analysis of biological compounds. However, due to its hydrophobicity, their surface strongly interacts with nonpolar analytes or species containing hydrophobic domains, resulting in a significant uncontrolled adsorption on the channel walls. This paper describes the migration of fluorescence-labeled amino acids and proteins using the poly(methyl methacrylate) microchip. A cationic starch derivative significantly decreases the adsorption of analytes on the channel walls. The migration time of the analytes was related to their molecular weight and net charge or pI of the analytes. FITC-BSA migrated within 2 min, and the theoretical plate number of the peak reached 480,000 plates/m. Furthermore, proteins with a wide range of pI values and molecular weights migrated within 1 min using the microchip.

Amino Acids↗

Analysis of polymerase chain reaction amplifications through phosphate detection using an enzyme-based microbiosensor in a microfluidic device.

An electrochemical method was developed for analyzing PCR amplification through the detection of inorganic phosphates (Pi). This method coupled a microchip to a nanoparticle comprising poly-5,2'-5',2''-terthiophene-3'-carboxylic acid (poly-TTCA)/pyruvate oxidase (PyO) modified microbiosensor. It detects Pi produced from the pyrophosphate (PPi), which is released as a byproduct of PCR. After completion of PCR, PPi is hydrolyzed to Pi by inorganic pyrophosphatase. On the microbiosensor surface, pyruvate was converted to H2O2 by PyO in the presence of Pi and oxygen, and subsequently, the anodic current of enzymatically generated H2O2 was detected at +0.5 V versus Ag/AgCl. The CE-EC analysis was completed within 2 min in a coated channel with 75.0 mm separation length at the field strength of -200 V/cm. Excellent operation stability of poly-TTCA/PyO was observed for a long period of analysis. The reproducibility of the analysis yielded an RSD of 3.4% (n = 22) for the peak areas and 1.8% (n = 22) for the migration times. The sensitivity of the analysis was 0.59 +/- 0.01 nA/cycle with a regression coefficient of 0.971.

Biosensing Techniques↗

Simultaneous analysis of nitrate and nitrite in a microfluidic device with a Cu-complex-modified electrode.

A CE microsystem coupled with a microchip and a copper-(3-mercaptopropyl) trimethoxysilane (Cu-MPS) complex-modified carbon paste electrode (CPE) was developed for the simultaneous analysis of nitrite and nitrate. The method is based on the electrocatalytic reduction of both analytes with the modified electrode. The Cu-MPS complex was characterized by voltammetric, XPS, and FT-IR analyses. Experimental parameters affecting the sensitivity of the modified electrode were assessed and optimized. The best separation was achieved in a 60 mm separation channel filled with a 20 mM acetate buffer of pH 5.0 containing 3.0 mM CTAB at separation field strength of -250 V/cm within 90 s. The detection potential for the simultaneous analysis of nitrite and nitrate was found to be -225 mV versus Ag/AgCl. A reproducible response (RSD of 3.2% (nitrite) and 2.8% (nitrate), n = 8) for repetitive sample injections reflected the negligible electrode fouling at the modified CPE. The interference effect was examined for other inorganic ions and biological compounds. A wide hydrodynamic range between 0.25 and 120 microM was observed for analyzing nitrite and nitrate with the sensitivities of 0.069 +/- 0.003 and 0.065 +/- 0.002 nA/microM, and the detection limits, based on S/N = 3, were found to be 0.09 +/- 0.007 and 0.08 +/- 0.009 microM, respectively. The applicability of the method to water and urine samples analyses was demonstrated.

Copper↗