PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “RIGIDITY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62Linked to original sources

Radiotherapy of pelvic malignancies: impact of two types of rigid immobilisation devices on localisation errors.

BACKGROUND AND PURPOSE: To determine the distribution of set-up errors for patients treated with and without two rigid partial immobilisation devices for pelvic malignancies. MATERIALS AND METHODS: 30 patients receiving pelvic irradiation with a four field technique underwent a total of 524 portal films. The patients are divided into 3 cohorts of 10 patients. The first cohort is treated on a standard treatment couch without immobilisation device (NI); the second and third cohorts are treated with a custom-made immobilisation device used in an attempt to improve set-up accuracy: an Alpha-Cradle mattress (AM) or an Orfit cast (OC). Set-up deviations are analysed in the X, Y, Z directions of a fixed coordinate system, corresponding to the lateral, cranio-caudal and antero-posterior direction, respectively. RESULTS: Considering the percentage of discrepancies < or = 5 mm between the simulation films and the portal films as a measure of set-up accuracy, immobilisation devices seem to increase accuracy: 88.5% (X) 79% (Y) and 100% (Z) with AM; 84% (X-Y), 97.5% (Z) with OC and only 76.5% (X), 40% (Y) and 65.5% (Z) for NI. The distribution of the systematic set-up errors for the three patient cohorts, defined as the mean patient displacement for the treatment course, had a mean and a standard deviation of (0.7 +/- 2.7) mm in the X-axis, (-5.5 +/- 2.6) mm in the Y-axis and (-0.9 +/- 2.2) mm in the Z-axis when no immobilisation is added; (0.8 +/- 1.7) mm, (-2 +/- 2.7) mm and (0.3 +/- 0.4) mm for the Alpha-Cradle group; (0.3 +/- 1.4) mm, (0.5 +/- 1.1) mm and (0.5 +/- 0.6) mm for the Orfit cast group. The distribution of random errors about the mean approximated a normal distribution and the standard deviations are 4.4 mm (X), 4.2 mm (Y) and 4.8 mm (Z) for NI; 3.3, 3.5 and 2.5 mm for the AM; 3.4, 3.3 and 2.7 mm for the OC. CONCLUSIONS: The two rigid immobilisation devices improve the reproducibility of a given pelvic field but there is a small benefit comparative to the cost and the cumbersome place of the devices.

Female↗

Clinical experiences of removing foreign bodies in the airway and esophagus with a rigid endoscope: a series of 3217 cases from 1970 to 1996.

This study examined 11,333 rigid endoscopy procedures performed in the Department of Otolaryngology, National Taiwan University Hospital, during a 27-year period from 1970 to 1996. Among these cases, 3217 were performed to remove foreign bodies from the airway (459 cases, 14.3%) and esophagus (2758 cases, 85.7%). Retrospective analysis of these data revealed that peanuts (217 cases) and animal bones (1184 cases) were the most frequent foreign bodies encountered in the airway and esophagus, respectively. The successful rate of removal of these foreign bodies was 99.9% (3213/3217). The complication rate was only 0.2% (8/3217), and the mortality rate was less than 0.1% (2/3217). On the basis of these results, we conclude that foreign bodies in the airway and esophagus can be removed safely under direct visualization through rigid endoscopy with relatively few complications. A significant finding in this study is the declining trend in the number of cases in recent years. Despite the decline in the number of procedures, endoscopic removal of foreign bodies remains as a vital skill of the aerodigestive tract surgeon.

Adolescent↗

Natural bioburden levels detected on rigid lumened medical devices before and after cleaning.

Controversy exists concerning the degree of microbial contamination associated with the use of rigid lumened medical devices, the efficacy of standard cleaning techniques used to remove pathogenic microorganisms from lumen channels, and whether patients are placed at risk of cross infection because of microbial contamination. In this study the level and types of microorganisms found on rigid lumened medical devices before and after cleaning in a hospital environment were investigated. The bioburden level after clinical use was found to be relatively low, ranging from 10(1) to 10(4) colony forming units (CFU) per device. After the instruments were cleaned, none of the devices studied contained bioburden levels greater than 10(4) CFU and 83% had bioburden levels less than or equal to 10(2) CFU. The bioburden present before cleaning was comprised of organisms derived from the handling of the device, from the hospital environment, and from the patient. The bioburden present after cleaning was comprised of organisms typically derived from the handling of the device and from the hospital environment. The level of bioburden per device was also related to the anatomic site where the device was used, with lower numbers of organisms found on devices exposed to sterile body sites and the respiratory tract.

Colony Count, Microbial↗

Interactions of VIP with rigid phospholipid bilayers: implications for vasoreactivity.

The purpose of this study was to determine whether vasoactive intestinal peptide (VIP), a pleiotropic amphipathic peptide, interacts with rigid liposomes composed of gel phase phospholipids. We found that incubation of VIP with small unilamellar gel phase liposomes composed of 1,2-dipalmitoyl-sn-glycero-3-phosphatidylcholine (DPPC) and egg phosphatidylglycerol (ePG) for 2h at room temperature had no significant effects on VIP secondary structure. Moreover, suffusion of VIP (0.01, 0.1 and 1.0nmol) incubated in saline or with DPPC/ePG liposomes (size, 30 and 100nm) for 2h at room temperature or 4 degrees C onto the intact hamster cheek pouch microcirculation elicited a similar concentration-dependent vasodilation except for 0.01nmol VIP (P<0.05). By contrast, incubation of VIP with gel phase liposomes overnight at 4 degrees C significantly potentiated vasodilation evoked by all three concentrations of the peptide in comparison to aqueous VIP (P<0.05). VIP-induced vasodilation was liposome size-independent. The ratio of VIP to phospholipids in DPPC/ePG liposomes was concentration-independent. Collectively, these data indicate that short-term interactions of VIP with rigid phospholipid bilayers are limited resulting in only modest effects on VIP vasoreactivity in vivo.

1,2-Dipalmitoylphosphatidylcholine↗

Evaluation of the dynamic cutoff rigidity model using dosimetry data from the STS-28 flight.

We have a developed a dynamic cutoff rigidity model based on computed world grids of vertical cutoff rigidities derived from employing the Tsyganenko magnetospheric model. The dynamic range of this model covers all magnetic activity levels specified by integer values of the Kp magnetic index. We present comparisons of the measured dose observed on the space shuttle during the August 1989 solar proton event with the dose computed from solar particles predicted to be allowed through the magnetosphere to the space shuttle position. We find a one-to-one correspondence between the portion of the orbit predicted to be subjected to solar protons and the portion of the orbit where solar particle dose measurements were obtained.

Cosmic Radiation↗

The limitations of using vertical cutoff rigidities determined from the IGRF magnetic field models for computing aircraft radiation dose.

Vertical cutoff rigidities derived from the International Geomagnetic Reference Fields (IGRF) are normally used to compute the radiation dose at a specific location and to organize the radiation dose measurements acquired at aircraft altitudes. This paper presents some of the usually ignored limits on the accuracy of the vertical cutoff rigidity models and describes some of the computational artifacts present in these models. It is noted that recent aircraft surveys of the radiation dose experienced along specific flight paths is sufficiently precise that the secular variation of the geomagnetic field is observable.

Aircraft↗

Rigid fixation of comminuted mandibular fractures.

Treatment of comminuted mandibular fractures has traditionally involved closed reduction with external fixation in an effort to avoid stripping periosteum from the bony segments. The purpose of this study was to evaluate retrospectively the success rate of rigid fixation used to treat 16 consecutive comminuted fractures of the mandible in 15 patients. The comminuted fractures were as follows: symphysis and body, 10; angle, 3; and ramus, 3. In 13 cases, AO stainless steel reconstruction plates were applied, with a minimum of three 2.7-mm tapped bone screws in each of the two stable segments. In most cases additional screws were placed into the comminuted fragments to stabilize them. In two patients, the mandibular ramus was comminuted (one case bilaterally), which made it impossible to place a large plate. These fractures were stabilized with multiple titanium miniplates (2.0 mm, tapped). All patients' fractures healed to a bony union without bone grafting. The mean maximum incisal opening at longest follow-up was 40 mm (range, 20 to 50 mm). All patients had a satisfactory facial form and none required further surgery for facial recontouring or malocclusion. Complications were observed in three patients. Two patients (13%) developed infections. Both infections were caused by loose hardware and responded to removal of the hardware and did not require any other treatment. One mandible refractured during manipulation after coronoidectomy to treat mandibular hypomobility, a sequellae of a gunshot wound that traversed both mandibular rami. This fracture healed after plate removal and a course of maxillomandibular fixation without bone grafting. This study suggests that rigid fixation of comminuted mandibular fractures is a viable treatment that satisfies the necessity for reestablishment of form and function with minimal morbidity.

Adult↗

Complications associated with rigid internal fixation of facial bone fractures.

Rigid internal fixation is now a common method for treating fractures of the facial skeleton. However, it is a very precise technique that requires more time than intraosseous wiring. This article reports the complications associated with rigid internal fixation of facial fractures in 223 patients and compares the findings with those accompanying intraosseous wiring.

Bone Plates↗

Stability following combined maxillary and mandibular osteotomies treated with rigid internal fixation.

Skeletal stability was examined in 16 patients following combined maxillary and mandibular osteotomies using rigid internal fixation. Postoperative changes (T2 to T3) were generally less than 1.0 mm for linear measurements and less than 2.0 degrees for angular measurements. The removal of maxillomandibular fixation (MMF) splints accounted for 85% to 95% of the counterclockwise rotation in the proximal and distal mandibular segments from T2 to T3. Maxillary inferior repositioning and large mandibular advancements exhibited the greatest tendency for relapse; however, the changes were less than with comparable procedures using nonrigid methods for stabilization. Except for large mandibular advancements, relapse was essentially unrelated to the magnitude of the surgical repositioning. Although the use of skeletal, maxillomandibular, and transosseous wire fixation have traditionally provided satisfactory clinical results, the use of rigid internal fixation in combined osteotomy procedures provides better stabilization of dentosseous segments when compared with these nonrigid methods, and may be particularly indicated in complex surgical procedures.

Adolescent↗

Positional changes in the mandibular condyle and amount of mouth opening after sagittal split ramus osteotomy with rigid or nonrigid osteosynthesis.

PURPOSE: The purpose of this study was to investigate postoperative positional changes in the mandibular condyle and mouth opening in patients undergoing sagittal split ramus osteotomy with either rigid or nonrigid osteosynthesis. PATIENTS AND METHODS: The forty-six patients with mandibular prognathism underwent sagittal split ramus osteotomy for mandibular set back followed by fixation with one of four methods: circumferential wire (n = 11), lag screw technique (n = 10), positional screw technique (n = 10), or miniplates (n = 15). The changes in the condylar position were assessed by measuring the angle of the condylar long axis (the condylar angle) on submentovertex radiographs. Mouth opening was evaluated by measuring the interincisal distance immediately after the release of maxillomandibular fixation and by monitoring the duration of trismus. RESULTS: Regardless of the procedure used the condylar angle increased in most patients after surgery (80 of 92 condyles). Although the amount of increase tended to be higher with rigid osteosynthesis than with nonrigid osteosynthesis, no significant differences were observed among the groups. Mouth opening was not significantly influenced by the type of osteosynthesis, and no patient complained of limitation 1 year after surgery. CONCLUSIONS: Although inward rotation of the condyle frequently occurs after osteosynthesis regardless of the procedure used, the changes in condylar position are within the range of adaptability of the patient.

Adaptation, Physiological↗

[Evaluation of training on intubation with a rigid fiber optic laryngoscope (UpsherScope)].

OBJECTIVE: To evaluate the learning of tracheal intubation with a new rigid fibreoptic laryngoscope (UpsherScope). STUDY DESIGN: Open prospective study. PATIENTS: Five investigators used the UpsherScope to intubate the trachea in 164 patients scheduled for gynaecological surgery requiring tracheal intubation. All patients were of physical class ASA I or II and criteria for difficult intubation were negative. METHODS: After muscle relaxation, 120 seconds were allowed to intubate the trachea with the UpsherScope. If intubation had not been achieved by that time, the attempt was considered as a failure and the trachea was intubated using conventional laryngoscopy. RESULTS: The overall success rate with the UpsherScope was 73%. Forty-five tracheas could not be intubated with the device within 120 seconds. The inability to insert the tracheal tube through the vocal cords despite a good view of the larynx (23/45) or the inability to visualise the glottis because of secretions (21/45), were the two main causes of failure. CONCLUSION: The UpsherScope, a new rigid fibreoptic laryngoscope devised for routine and difficult intubation, is robust and allows the view of the tracheal tube passing between the vocal cords. However, in this study the intubation success rate remained low and was not improved by further experience. No benefit was found with the UpsherScope in patients with normal airways. Further studies are necessary to assess its efficiency in cases of difficult intubation.

Adult↗

Simple arthrolysis for flexor rigidity of the proximal interphalangeal joint.

The authors report 19 cases of simple arthrolysis of the proximal interphalangeal joint for flexion rigidity. Their cases were limited to isolated lesions of the joint without any flexor or extensor tendon involvement. The technique is described, and the importance of postoperative physical therapy is stressed. The results in these cases, in contrast with those in complicated cases of rigidity, are very satisfactory. The etiology is primarily sprains and dislocations of the proximal interphalangeal articulation, immobilized for too long a time in flexion (in the so-called "functional position").

Combined Modality Therapy↗

Preliminary report on the rigid disc lens.

Theoretically, a circular and lenticular implant is the most appropriate for implantation in the capsular bag. Various prototypes have led to a single-piece model in polymethylmethacrylate with a bioconvex 7-mm optic and a 9-mm total diameter. This so-called disc lens has been implanted in 61 eyes. The longest follow-up is 18 months. Thus far, the clinical results are excellent. It appears that this 9-mm disc lens permits centration without acting as a spring in the capsular bag. A large mydriasis and the use of viscoelastic material are mandatory for inserting the rigid disc lens. A circular implant appears to be an advance in IOL design adapted to the capsular bag configuration. A greater number of cases and longer follow-up are necessary to evaluate the rigid disc lens.

Equipment Design↗

Tracking of non-rigid articulatory organs in X-ray image sequences.

This article presents a system for the automated tracking of non-rigid anatomic structures in two-dimensional image sequences, which was primarily applied to X-ray image sequences of the vocal tract. In this particular application articulatory organs have to be measured to investigate the complex dynamic characteristics of human speech production. Of particular interest is a robust boundary detection of non-rigid organs such as lips and tongue. To solve this ill-posed detection problem under the presence of transparently superimposing structures, varying textural appearances of organs and noise, a two-level system is proposed. At the lower level, several edge-, region-, and motion-based image operators are combined to exploit their respective benefits and concomitantly compensate for their deficiencies. For the sake of precision, the result of these operators are not represented as larger tokens, such as line segments, but remain pixel-related cues or image evidences. At the higher level, an active contour-based component allows for the introduction of a priori knowledge about the object to be detected.

Algorithms↗

Rigid internal fixation of mandibular fractures. An analysis of 270 fractures treated using the AO/ASIF method.

The results are reported on 214 patients treated for 270 mandibular fractures, using rigid internal fixation. Of these, 172 fractures (63.7%) in 131 patients had been re-evaluated at final follow-up in connection with plate and screw removal, on average 15.2 months, postoperatively. Although one-third of the patients had a history of alcohol abuse, and 86% were treated with a delay of more than 24 h (mean 3.2 days), good primary bone healing was observed in 93.9% of the patients. Infections, seen in 6.1% of the patients, were related exclusively to inadequate stability of the fracture. Malocclusion, observed in 18.2% of 159 dentate patients, was caused by incorrect plate bending and insufficient fracture reduction. Immediate postoperative dysfunction of the inferior alveolar nerve in 58.1% of the cases, and of the mandibular branch of the facial nerve in 12.7%, was followed by almost total recovery 1 year after operation. It is concluded that rigid internal fixation is a reliable method of treatment, especially indicated for patients with reduced healing capacity and poor co-operation.

Adolescent↗

Histomorphometric evaluation of stress shielding in mandibular continuity defects treated with rigid fixation plates and bone grafts.

Histomorphometric techniques were used to evaluate the stress shielding effect in bilateral bone grafts in 4 Macaca fascicularis monkeys. Bilateral continuity defects were created and grafted by replacing the resected portion of the mandible and iliac crest bone into the defect area. Both sides were plated with rigid internal fixation plates. Three months after bone grafting, the plate was removed from one side while the other plate was left in place. The animals were sacrificed at 1, 4, 6, and 8 months after plate removal and the grafted areas removed for histomorphometric analysis. This study documents decreased bone volume as well as smaller interlabel width on the plated side, suggesting a stress shielding effect as a result of the rigid internal fixation plate.

Animals↗

Long-term effects of orthognathic surgery on the temporomandibular joint: comparison of rigid and nonrigid fixation methods.

Sixty-six patients were examined between 2 and 9.5 years after bilateral sagittal split mandibular ramus osteotomy. Thirty-two patients had nonrigid fixation consisting of superior border wires and intermaxillary fixation, while 34 patients had rigid plate fixation of the osteotomy sites with immediate function. There were no demonstrable long-term differences between the two groups with respect to mandibular vertical opening, crepitance, and temporomandibular joint pain. Masticatory muscle pain and temporomandibular joint clicking improved with rigid fixation and worsened with nonrigid fixation.

Adult↗

Problems with rigid seed strand lodging during prostate implantation: a proposed mechanism and solution.

Since the introduction of rigid strands of radioactive seeds embedded in absorbable suture material, many brachytherapists have experienced problems with the strands lodging inside the implant needle during the deposition process. By using a scanning electron microscope, we examined some potential factors which could lead to this problem. It seems plausible that the lodging is due to two factors: prostate tissue hindering the motion of the strand initially, and friction between the strand braids and the inner surface of the needle. Both result in an "accordion effect" as the stylet applies pressure on the strand. Based on this assumption, a solution was found. A combination of using needles with a polished inner surface, and repeated clockwise and counterclockwise 360 degrees twisting of the needle about the stylet during the deposition process allows for smooth deposition of the strand at the intended location. By using this technique, one is able to exploit the potential dosimetric advantages of rigid seed strand implants without additional problems.

Brachytherapy↗