PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,117 records · Page 62Linked to original sources

Reagentless biosensors based on self-deposited redox polyelectrolyte-oxidoreductases architectures.

Reagentless fructose and alcohol biosensors have been produced with a versatile enzyme immobilisation technique which mimics natural interactions and flexibility of living systems. The electrode architecture is built up on electrostatic interactions by the sequential adsorption of redox polyelectrolytes and redox enzymes giving rise to the efficient transformation of substrate fluxes into electrocatalytic currents. All investigated multilayer structures were self-deposited on 3-mercapto-1-propanesulfonic acid monolayers self-assembled on gold electrodes. Fructose dehydrogenase, horseradish peroxidase (HRP) and the couple HRP-alcohol oxidase were electrochemically connected with a cationic poly[(vinylpyridine)Os(bpy)2Cl] redox polymer (RP) interface in a layer-by-layer self-deposited architecture. The dependence of the distance on the electrochemical response of this interface was also studied showing a clear decrease in the Faradaic current when the distance to the electrode surface was increased. The sensitivities obtained for each biosensor were 19.3, 58.1 and 10.6 mA M(-1) cm(-1) for fructose, H2O2 and methanol, respectively. The sensitivity values can be easily controlled by a rational deposition and manipulation of the charge in the catalytic layers. The electrostatic assembly of the electrochemical interface and the catalytic layers resulted in integrated biochemical systems in which mass transfer diffusion and heterogeneous catalytic and electron transfer steps are efficiently coupled and can be easily manipulated.

Alcohol Oxidoreductases↗

Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks.

Engineered variants of Drosophila melanogaster acetylcholinesterase (AChE) were used as biological receptors of AChE-multisensors for the simultaneous detection and discrimination of binary mixtures of cholinesterase-inhibiting insecticides. The system was based on a combination of amperometric multielectrode biosensors with chemometric data analysis of sensor outputs using artificial neural networks (ANN). The multisensors were fully manufactured by screen-printing, including enzyme immobilisation. Two types of multisensors were produced that consisted of four AChE variants each. The AChE mutants were selected in order to obtain high resolution, enhanced sensitivity and minimal assay time. This task was successfully achieved using multisensor I equipped with wild-type Drosophila AChE and mutants Y408F, F368L, and F368H. Each of the AChE variants was selected on the basis of displaying an individual sensitivity pattern towards the target analytes. For multisensor II, the inclusion of F368W, which had an extremely diminished paraoxon sensitivity, increased the sensor's capacity even further. Multisensors I and II were both used for inhibition analysis of binary paraoxon and carbofuran mixtures in a concentration range 0-5 microg/l, followed by data analysis using feed-forward ANN. The two analytes were determined with prediction errors of 0.4 microg/l for paraoxon and 0.5 microg/l for carbofuran. A complete biosensor assay and subsequent ANN evaluation was completed within 40 min. In addition, multisensor II was also investigated for analyte discrimination in real water samples. Finally, the properties of the multisensors were confirmed by simultaneous detection of binary organophosphate mixtures. Malaoxon and paraoxon in composite solutions of 0-5 microg/l were discriminated with predication errors of 0.9 and 1.6 microg/l, respectively.

Acetylcholinesterase↗

Ascorbate oxidase based amperometric biosensor for organophosphorous pesticide monitoring.

An amperometric principle based biosensor containing tissues of cucumber, rich in ascorbic acid oxidase, was used for the detection of organophosphorous (OP) pesticide ethyl paraoxon, which inhibits the activity of ascorbic acid oxidase. The optimal concentration of ascorbic acid used as substrate was found to be 5.67 mM. The biosensor response was found to reach steady state within 2 min. A measurable inhibition (> 10%) was obtained with 10 min incubation of the enzyme electrode with different concentrations of the pesticide. There was a linear relationship between the percentage of inhibition of the enzyme substrate reaction and the pesticide (ethyl paraoxon) concentration in the range 1-10 ppm with a regression value 0.9942.

Ascorbate Oxidase↗

Inhibitive determination of mercury and other metal ions by potentiometric urea biosensor.

The biosensor with urease entrapped in PVC layer at the surface of pH-sensitive iridium oxide electrode was applied for testing of mercury and other metal ions inhibition on enzymatic reaction. The calculation of inhibition effect was based on the measurement of initial rate of decrease of biosensor potential (proportional to the initial rate of enzymatic reaction) after addition of substrate after inhibition step. Some differences of inhibition extent were observed for various mercury forms (Hg(NO3)2, HgCl2, PhHgCl and Hg2(NO3)2) as well as for other heavy metal ions investigated as potential interferents. Because the method was not specific, it was applied for the determination of total inhibition effect caused by heavy metal ions in water samples. In the case of most cations tested the total recovery of enzyme activity was possible using Tris buffer solution with EDTA and thioacetamide after less than 10 min regeneration time.

Biosensing Techniques↗

Nanoporous anti-fouling silicon membranes for biosensor applications.

The ability to create biocompatible well-controlled membranes has been an area of great interest over the last few years, particularly for biosensor applications. The present study describes the fabrication and characterization of novel nanoporous micromachined membranes that exhibit selective permeability and low biofouling. Results indicate that such membranes can be fabricated with uniform pore sizes capable of the simultaneous exclusion of albumin and diffusion of glucose. Compared to polymeric membranes of similar pore size, micromachined silicon membranes allowed more than twice the amount of glucose diffusion after 240 min and complete albumin exclusion. Moreover, membranes exhibit no morphological change or degradability in the presence of biological proteins and fluids at 37 degrees C. The results point to the potential of using such membranes for implantable biosensor applications. With monodisperse pores sizes as small as 10 nm, these membranes offer advantages in their reproducibility, stability, and ability to be integrated in silicon-based biosensing technology.

Albumins↗

Optical fiber biosensor for the determination of low biochemical oxygen demand.

An optical fiber biosensor was developed for the evaluation of low Biochemical Oxygen Demand (BOD) values in river waters. Artificial wastewater (AWW) solution was employed as standards for the calibration of the BOD sensor. The response time of the sensor was 15 min, and the optimal BOD response was observed at 30 degrees C, pH 7.0. A linear relationship was obtained between the output voltage and BOD5 values, and the range of determination was 1-10 mg l(-1) BOD. The sensor response was almost not influenced by chloride ion up to 1000 mg l(-1), and also not affected by heavy metal ions (Fe3+, Cu2+, Mn2+, Cr3+, Zn2+). The BOD of river waters was estimated by using the optical fiber biosensor, and good correlation between the sensor and BOD5 test was obtained (r2 = 0.971).

Bacteria↗

Silica sol-gel composite film as an encapsulation matrix for the construction of an amperometric tyrosinase-based biosensor.

An amperometric tyrosinase enzyme electrode for the determination of phenols was developed by a simple and effective immobilization method using sol-gel techniques. A grafting copolymer was introduced into sol-gel solution and the composition of the resultant organic-inorganic composite material was optimized, the tyrosinase retained its activity in the sol-gel thin film and its response to several phenol compounds was determined at 0 mV vs. Ag/AgCl (sat. KCl). The dependences of the current response on pH, oxygen level and temperature were studied, and the stability of the biosensor was also evaluated. The sensitivity of the biosensor for catechol, phenol and p-cresol was 59.6, 23.1 and 39.4 microA/mM, respectively. The enzyme electrode maintained 73% of its original activity after intermittent use for three weeks when storing in a dry state at 4 degrees C.

Biosensing Techniques↗

Optical peroxide biosensor using the electrically controlled-release technique.

An optical biosensor using an electrically controlled-release system was developed for the measurement of peroxide concentration. The electrically controlled-release system consisted of a current-supplying system and a polymer complex by hydrogen bonding between the carboxylic and oxazoline group. The polymer complex was formed below pH 5.0 and was degraded above pH 5.4. The local pH change near the surface of the polymer complex could be controlled by applying the electric current to release an enzyme reaction reagent, 4-hydroxyphenylacetic acid (HPA), in the polymer complex. The releasing rate of HPA was proportional to the electric current applied to the polymer complex. The model of the controlled-release system was proposed to predict the degradation velocity of the polymer complex, which is equivalent to the releasing rate of HPA. The released HPA and analyte, peroxide, flowed into the reactor with the immobilized enzyme and then reacted with the enzyme. The peroxide concentration was measured based on the fluorescence detection of enzyme reaction product, 6,6'-dihydroxy (1,1'-biphenyl) 3,3'-diacetic acid (DBDA). The proposed biosensor had the linear analytical range of 0.025 approximately 1.0 mM with a response time of 20 min, good repeatability, and reproducibility.

Biosensing Techniques↗

Real-time detection of L-ascorbic acid and hydrogen peroxide in crude food samples employing a reversed sequential differential measuring technique of the SIRE-technology based biosensor.

Detection of the common electrochemical interferents, ascorbic acid and hydrogen peroxide, using a SIRE (Sensors based on Injection of the Recognition Element) technology based biosensor in reverse mode operation is reported. The differential measuring principle employed in the SIRE biosensor during operation in reverse mode is such that the sample is measured first in the presence of enzyme (yielding matrix signal only), and then measured again in the absence of enzyme (yielding signal from matrix+analyte). Subtraction of the signal obtained in the presence of enzyme from the signal obtained in the absence of enzyme gives a specific signal for the analyte only and correlates directly to its concentration in solution. The linear range for the determination of ascorbic acid and hydrogen peroxide was 0-3 mM and 0-2 mM, respectively, with an enzyme concentration of 25 U ascorbate oxidase/ml and 1000 U catalase/ml. The reproducibility was 5% for ascorbic acid (R.S.D. n=15) and 10% for hydrogen peroxide (R.S.D. n=18). The cost per measurement was 0.28 USD for ascorbic acid analysis and 0.0008 USD for hydrogen peroxide analysis. The degradation of ascorbic acid in cereal was followed in real-time, as was the stabilization of low pH on the degradation process.

Ascorbate Oxidase↗

Stand-off tissue-based biosensors for the detection of chemical warfare agents using photosynthetic fluorescence induction.

Tissue biosensors made from immobilized whole-cell photosynthetic microorganisms have been developed for the detection of airborne chemical warfare agents and simulants. The sensor read-out is based on well-known principles of fluorescence induction by living photosynthetic tissue. Like the cyanobacteria and algae from which they were constructed, the sensors are robust and mobile. The fluorescence signal from the sensors was stable after 40 days, storage and they can be launched or dropped into suspected danger zones. Commercially available hand-held fluorometric detector systems were used to measure Photosystem II (PSII) photochemical efficiency of green algae and cyanobacteria entrapped on filter paper disks. Toxic agents flowing in the gas stream through the sensors can alter the characteristic fluorescence induction curves with resultant changes in photochemical yields. Tabun (GA), sarin (GB), mustard agent, tributylamine (TBA) (a sarin stabilizer), and dibutyl sulfide (DBS) (a mustard agent analog) were tested. Upper threshold limits of detectability for GA, TBA, and DBS are reported. With additional research and development, these biosensors may find application in stand-off detection of chemical and perhaps biological warfare agents under real-world conditions.

Biosensing Techniques↗

A genetically engineered cell-based biosensor for functional classification of agents.

Cell-based biosensors (CBBs) utilize whole cells to detect biologically active agents. Although CBBs have shown success in detecting the presence of biological agents, efforts to classify the type of agent based on functional activity have proven difficult because multiple biochemical pathways can lead to the same cellular response. However, a new approach using a genetically-engineered cell-based biosensor (GECBB) described in this paper translates this cross-talk noise into common-mode noise that can be rejected. The GECBB operates by assaying for an agent's ability to differentially activate two populations of cells, wild-type (WT) cells and cells genetically engineered to lack a specific receptor, knockout (KO) cells. Any biological agent that targets the knocked out receptor will evoke a response in the WT but not in the KO. Thus, the GECBB is exquisitely sensitive to agents that effect the engineered pathway. This approach provides the benefits of an assay for specific functional activity while simplifying signal analysis. The GECBB implemented was designed to be sensitive to agents that activate the beta 1-adrenergic receptor (beta 1-AR). This was achieved by using mouse cardiomyocytes in which the beta 1-AR had been knocked out. The cellular signal used in the GECBB was the spontaneous beat rate of the two cardiomyocyte syncitia as measured with microelectrode arrays. The GECBB was able to detect the beta-AR agonist isoproterenol (ISO) at a concentration of 10 microM (P<0.005).

Adrenergic beta-Agonists↗

Biosensors in fish production and quality control.

Fishery products are important not only from a nutritional point of view, but also as an item of international trade and foreign exchange earner for a number of countries in the world. Fish and shellfish are highly perishable, and prone to vast variations in quality due to differences in species, environmental habitats, feeding habits, etc. In addition, they can also function as carriers of several microbial and other health hazards. Therefore, maintenance of quality is of utmost importance in production and trade of fishery products. Most of the current quality control techniques are time consuming and cumbersome. There is an excellent scope for the application of biosensors in the seafood industry including the rapidly expanding aquaculture operations for fast assessment of quality. This article discusses the scope of applications biosensors in the seafood industry.

Animals↗

Electrodes modified with nitrofluorenone derivatives as a basis for new biosensors.

We report about the electrocatalytic properties of electrodes modified by adsorption of nitro-fluorenone derivatives. The stable, adherent monolayer of these catalyst precursors can be transformed electrochemically into the corresponding hydroxylamine compounds (R-NO(2)+4e+4H(+)-->R-NHOH+H(2)O). The completely reversible two electron oxidation of the hydroxylamine leads to the nitroso compounds (R-NHOH-->R-NO+2e+2H(+)) that exhibit high catalytic activity in the electrooxidation of NADH at low overpotentials (-30 mV vs. Ag/AgCl) and therefore constitute a new family of efficient redox mediators for biosensor applications. A significant increase in catalytic activity (up to 500%) is observed after addition of calcium ions to the electrolyte. This is explained by a specific and bridging complexation between the coenzyme's phosphate groups and a carboxyl group present in the catalyst molecule. The interaction favours the contact between NADH and the surface confined catalyst, leading to a higher electron transfer efficiency. This interaction can be used in an approach of molecular level design for controlled monolayer deposition of catalyst, Ca(2+), NAD+ and enzyme. A very simple and inexpensive modification scheme, essentially based on electrostatic attraction, leads to electrodes that can be employed as reagentless biosensors for the electrochemical detection of common and commercially interesting analytes like glucose.

Biosensing Techniques↗

Photosystem II-based biosensors for the detection of pollutants.

Photosystem II (PSII) is the supramolecular pigment-protein complex in the chloroplast, which catalyses the light-induced transfer of electrons from water to plastoquinone (PQ) in a process that evolves oxygen. The PSII complex is also known to bind some groups of (photosynthetic) herbicides, heavy metals and other chemical substances that affect its activity. The objective of this study is to provide an overview of the systems available for the bioassay of pollutants using biosensors that are based on the photochemical activity of PSII. Some applications of the PSII-based biosensors including herbicide, heavy metal monitoring and the detection of radiation in space experiments are reported.

Biosensing Techniques↗

The non-specific inhibition of enzymes by environmental pollutants: a study of a model system towards the development of electrochemical biosensor arrays.

Previous research has shown that lactate dehydrogenase (LDH) was competitively inhibited by pentachlorophenol (PCP) and a modified assay produced a detection limit of 1 microM (270 microg l(-1)). This work used spectrophotometric rate-determination but in order to move towards biosensor development the selected detection method was electrochemical. The linkage of LDH to lactate oxidase (LOD) provided the electroactive species, hydrogen peroxide. This could be monitored using a screen-printed carbon electrode (SPCE) incorporating the mediator, cobalt phthalocyanine, at a potential of +300 mV (vs. Ag/AgCl). A linked LDH/LOD system was optimised with respect to inhibition by PCP. It was found that the SPCE support material, PVC, acted to reduce inhibition, possibly by combining with PCP. A cellulose acetate membrane removed this effect. Inhibition of the system was greatest at enzyme activities of 5 U ml(-1) LDH and 0.8 U ml(-1) LOD in reactions containing 246 microM pyruvate and 7.5 microM NADPH. PCP detection limits were an EC(10) of 800 nM (213 microg l(-1)) and a minimum inhibition detectable (MID) limit of 650 nM (173 microg l(-1)). The inclusion of a third enzyme, glucose dehydrogenase (GDH), provided cofactor recycling to enable low concentrations of NADPH to be incorporated within the assay. NADPH was reduced from 7.5 to 2 microM. PCP detection limits were obtained for an assay containing 5 U ml(-1) LDH, 0.8 U ml(-1) LOD and 0.1 U ml(-1) GDH with 246 microM pyruvate, 400 mM glucose and 2 microM NADPH. The EC(10) limit was 150 nM (39.9 microg l(-1)) and the MID was 100 nM (26.6 microg l(-1)). The design of the inhibition assays discussed has significance as a model for other enzymes and moves forward the possibility of an electrochemical biosensor array for pollution monitoring.

Biosensing Techniques↗

Optical organophosphorus biosensor consisting of acetylcholinesterase/viologen hetero Langmuir-Blodgett film.

The fiber-optic biosensor consisting of an acetylcholinesterase (AChE)-immobilized Langmuir-Blodgett (LB) film was developed to detect organophosphorus compounds in contaminated water. The sensing scheme was based on the decrease of yellow product, o-nitrophenol, from a colorless substrate, o-nitrophenyl acetate, due to the inhibition by organophosphorus compounds on AChE. Absorbance change of the product as the output of enzyme reaction was detected and the light was guided through the optical fibers. The enzyme portion of the sensor system was fabricated by the LB technique for formation of the enzyme film. AChE-immobilized LB film was formed by adsorbing the enzyme molecules onto a viologen monolayer using the electrostatic force. The proposed kinetics for irreversible inhibition of organophosphorus compounds on AChE agreed well with the experimental data. The surface topography of AChE-immobilized LB film was investigated by atomic force microscope (AFM). The immobilized AChE had the maximum activity at pH 7. The proposed biosensor could successfully detect the organophosphorus compounds up to 2 ppm and the response time to steady signal of the sensor was about 10 min.

Acetylcholinesterase↗

Comparison of a conventional immunoassay (ELISA) with a surface plasmon resonance-based biosensor for IGF-1 detection in cows' milk.

Recombinant bovine somatotropin (rBST) treatment is adopted in dairy cows to augment milk yield. Previous studies showed that insulin-like growth factor-1 (IGF-1) is present in milk from cows treated with rBST. Since IGF-1 is a suspected carcinogen, its presence in milk for human consumption is potentially a health hazard. Therefore rBST use, still authorized in the United States, has been revoked in Canada and is under evaluation in the EU. The rising attention on IGF-1 presence in alimentary milk focused the necessity to develop specific, sensitive and rapid IGF-1 detection systems. We have developed a solid phase enzyme-linked immunoassay (ELISA) and also an automated surface plasmon resonance-based biosensor system (BIA-technology) for evaluating IGF-1 in fresh cow's milk. Hyperimmune polyclonal anti-IGF-1 antibodies were characterized with respect to their specific binding capacity to IGF-1. The results obtained with these two methods have been compared. This study shows the potential usefulness of the biosensor technology for biomolecular interaction analysis. The features of this technology (fully automated, measures in real time, sharpened yes/no response) offer several advantages compared to ELISA in the detection of compounds in fresh cows' milk (MURST 40%; CNR P.F. MADESS 2).

Animals↗

Development of a screen-printed amperometric biosensor for the determination of L-lactate dehydrogenase level.

We attempted to develop a screen-printed biosensor for the amperometric determination of L-lactate dehydrogenase (LDH) level on the basis of NAD(+)/NADH-dependent dehydrogenase reaction. The printing ink for the working electrode consisted of L-lactate, NAD(+), composite polymer of hydroxyethyl cellulose with ethylene glycol, 3,4-dihydroxybenzaldehyde (3,4-DHB) as an electron transferring mediator, and graphite as the conducting material. The 3,4-DHB was electropolymerized on the carboneous working electrode by potential cycling between -200 and +300 mV vs. Ag/AgCl reference electrode. Through the electrocatalytic reaction with immobilized 3,4-DHB, the NADH generated by the LDH reaction could be efficiently oxidized at lower potential than the unmodified carbon electrode. The analytical performance of the electrode was characterized in terms of linear sensing range and detection limit for LDH. The response from the developed biosensor was linear up to 500 U/l of LDH, and the detection limit of 50 U/l was observed at the signal-to-noise ratio of 3.

Biosensing Techniques↗