PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Application”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

Application and modulation of a permanent hydrogen peroxide-induced oxidative stress to cultured astroglial cells.

Hydrogen peroxide is often applied to cultured brain cells to investigate functions of these cells under oxidative stress. However, this peroxide might be quickly detoxified by cultured neural cells. At least cultured astroglial cells dispose of exogenous H(2)O(2) with a half-time in the minute range [R. Dringen, B. Hamprecht, Involvement of glutathione peroxidase and catalase in the disposal of exogenous hydrogen peroxide by cultured astroglial cells, Brain. Res. 759 (1997) pp. 67-75]. Therefore, application of hydrogen peroxide to astroglial cells leads only to a period of transient oxidative stress which depends on the ability of the cells to detoxify the peroxide. In order to apply a permanent H(2)O(2)-induced oxidative stress to astroglial cells the generation of H(2)O(2) by the coupled reactions of xanthine oxidase (XO) and superoxide dismutase (SOD) was studied and this system was applied to cultured astroglial cells. In the presence of astroglial cells, an almost constant steady state concentration of H(2)O(2) in the range up to 100 microM was generated, which depended on the activity of the XO applied. These steady state levels of H(2)O(2) were: (i) elevated by application of additional XO, (ii) slowly reduced by application of the XO inhibitor allopurinol, and (iii) immediately reduced to zero by application of catalase or a combination of allopurinol plus catalase. In conclusion, the method presented allows the application of an almost constant exogenous H(2)O(2) stress to cultured cells.

Allopurinol↗

Postoperative intravaginal brachytherapy for endometrial cancer; dosimetric analysis of vaginal colpostats and cylinder applicators.

PURPOSE: To investigate the dosimetric differences between colpostats and cylinder applicators for intravaginal brachytherapy. METHODS AND MATERIALS: Dose distributions near vaginal colpostats and dome cylinders were computed with a commercial high-dose-rate treatment-planning system and verified by spot measurements by using LiF thermoluminescent dosimeters. Taking source anisotropy into account, dwell times were optimized by the computer by using the polynomial optimization on dose points method to give uniform doses along the lateral surfaces of the applicators. In addition, the effects of vaginal packing and the separation distance between colpostats were studied by computing the dose to the vaginal mucosa, assuming 0.5 and 1.0 cm of vaginal packing and colpostat separation, respectively. RESULTS: The computed and measured doses agreed within +/- 7%. Surface doses were similar for both types of applicators when the effect of shielding in the colpostats was neglected. However, percent depth doses in the anterior/posterior and lateral directions were higher for the cylinder, whereas the dose fall-off along the longitudinal patient axis was less pronounced for the colpostats. When vaginal packing at the anterior and posterior surface of the colpostats was increased from 0 to 5, 10, and 15 mm, the corresponding vaginal dose decreased from 97% of the prescription dose to 60%, 39%, and 26%, respectively. Separating the colpostats from 0 to 5 and 10 mm reduced the surface dose near the bladder/rectum to 80% and 67%, respectively, whereas the respective apex dose decreased from 105% of prescription to 91% and 77%. CONCLUSIONS: Colpostats and cylinder applicators for intracavitary brachytherapy have their advantages and disadvantages in depth dose distribution and clinical use. If treatment is confined to the vaginal apex, either applicator can be used. However, the colpostat separation should be kept to a minimum, and vaginal packing should be applied with great care to avoid generating cold spots along the upper vaginal surface and vaginal cuff.

Brachytherapy↗

Improvement of fracture healing by systemic administration of growth hormone and local application of insulin-like growth factor-1 and transforming growth factor-beta1.

Fracture healing is influenced by numerous hormones, growth factors, and cytokines. The systemic administration of growth hormone (GH) has shown to accelerate bone regeneration. Local application of growth factors, such as insulin-like growth factor-1 (IGF-1) and transforming growth factor-beta-1 (TGF-beta1), are known to stimulate bone metabolism. Until now, the exact local and systemic mechanisms that lead to improved bone regeneration remain unclear. In addition, the effect of systemic administration of GH as compared with locally delivered growth factors on fracture healing in rats is not known. A midshaft fracture of the right tibia of 5-month-old female Sprague-Dawley rats (n = 80) was intramedullary stabilized with IGF-1 and TGF-beta1 coated vs. uncoated titanium K-wires. The growth factors were incorporated in a poly(D,L-lactide) (PDLLA) coating and released continuously throughout the experiment. Recombinant species-specific (rat) GH was applied systemically (2 mg/kg body weight) by daily subcutaneous injection and compared with a placebo group. The healing process was radiologically monitored. Twenty-eight days after fracture biomechanical torsional testing was performed. The consolidation and callus composition, including quantification of cartilage and mineralized tissue, was traced in histomorphometrical investigations using an image analysis system. Both methods, the systemic administration of GH and the local application of growth factors, showed significant biomechanical and histological effects on fracture healing. The local growth factor application showed a stronger effect on fracture healing than the systemic GH injection. The combined application of both methods did not accelerate the effect on bone healing compared with the single application. It is therefore concluded that combining local and systemic stimulating methods does not provide further additive effects with regard to fracture healing.

Animals↗

Treatment of allergic and vasomotor rhinitis by the local application of silver nitrate.

A new, simple and effective local treatment of allergic and vasomotor rhinitis is presented. Using 15 per cent silver nitrate, bilateral chemical cautery of the anterior part of the nasal septum and inferior turbinates has been carried out at weekly intervals on 1 to 5 occasions, in 41 cases. No distinction was made between allergic rhinitis and vasomotor rhinitis. 92.6 per cent of cases belonged to the age group of 11 to 50 years. There was a slight predominance of female over male patients in this study. Only those cases were selected who had sneezing as the presenting symptom, while 17 per cent of these patients also suffered from asthma. The eosinophil count in the blood was below 5 per cent in 73.2 per cent of cases, and was above 10 per cent in 9.8 per cent of cases. Eosinophils were present in the nasal secretions of of 66.6 per cent of patients. Intestinal parasites were detected in the stools of 19.5 per cent of cases. No significant quantity of methaemoglobin was detected in the blood of any patient. Silver nitrate was applied after topical anaesthesia with 4 per cent lignocaine solution. The majority of patients had 2 to 4 applications. 68.3 per cent of patients had good relief, particularly from sneezing and watering of the nose. If patients treated with only a single application of silver nitrate are excluded from the series, 79.4 per cent patients reported relief. Significantly, out of 7 cases who were suffering from allergic rhinitis as well as asthma, 57.1 per cent of cases had freedom from the asthma. Among 3 patients who had no relief with earlier intranasal hydrocortisone injections, 66.6 per cent cases had good relief with silver nitrate. One patient who had good relief from allergic rhinitis developed anosmia after this treatment and some patients experienced transient sneezing and rhinorrhoea after the application of silver nitrate. Long-term results are awaited and it is suggested that further studies are necessary regarding the number of applications, the interval between applications, the strength of the silver nitrate solution, and the possible use of other chemical or physical agents for this mode of treatment.

Administration, Topical↗

Recommendations for the application of bone density measurement. What can you believe?

This study examined the conclusions of published reports that review the literature and make recommendations about appropriate applications of bone density measurement. It is based on a survey of 22 organizations producing such reports between 1986 and Spring 1995. Overall, the application of bone density measurement for the diagnosis of osteoporosis was supported by 65% of reports, by 44% for the monitoring and follow-up of patients with previously diagnosed disease, and by 59% for monitoring and follow-up of patients receiving treatment that may affect their bone density. A smaller proportion of reports from government and public organizations compared with other types of organizations and a smaller proportion of reports using more rigorous methods supported the applications for bone density measurement identified in the survey. A larger proportion of the reports published after 1990 compared with those published between 1986 and 1990 support the applications of bone density measurement, with the exception of population screening. The results of this survey suggest that there is considerable disagreement about the potential applications of bone density measurement. Publicly funded organisations and those using more rigorous methods tended to be more conservative in their conclusions.

Bone Density↗

Sensing cantilever beam bending by the optical lever technique and its application to surface stress.

Cantilever beams, both microscopic and macroscopic, are used as sensors in a great variety of applications. An optical lever system is commonly employed to determine the deflection and thereby the profile of the cantilever under load. The sensitivity of the optical lever must be calibrated, and this is usually achieved by application of a known load or deflection to the free end of the cantilever. When the sensing operation involves a different type of load or a combination of types of loadings, the calibration and the deflection values derived from it become invalid. Here we develop a master equation that permits the true deflection of the cantilever to be obtained simply from the measurement of the apparent deflection for uniformly distributed loadings and end-moment loadings. These loadings are relevant to the uniform adsorption or application of material to the cantilever or the application of a surface stress to the cantilever and should assist experimentalists using the optical lever, such as in the atomic force microscope, to measure cantilever deflections in a great variety of sensing applications. We then apply this treatment to the experimental evaluation of surface stress. Three forms of Stoney's equation that relate the apparent deflection to the surface stress, which is valid for both macroscopic and microscopic experiments, are derived. Analysis of the errors arising from incorrect modeling of the loading conditions of the cantilever currently applied in experiments is also presented. It is shown that the reported literature values for surface stress in microscopic experiments are typically 9% smaller than their true value. For macroscopic experiments, we demonstrate that the added mass of the film or coating generally dominates the measured deflection and must be accounted for accurately if surface stress measurements are to be made. Further, the reported measurements generally use a form of Stoney's equation that is in error, resulting in an overestimation of surface stress by a factor >5.

Journal Article↗

Calculated absorption and scattering properties of gold nanoparticles of different size, shape, and composition: applications in biological imaging and biomedicine.

The selection of nanoparticles for achieving efficient contrast for biological and cell imaging applications, as well as for photothermal therapeutic applications, is based on the optical properties of the nanoparticles. We use Mie theory and discrete dipole approximation method to calculate absorption and scattering efficiencies and optical resonance wavelengths for three commonly used classes of nanoparticles: gold nanospheres, silica-gold nanoshells, and gold nanorods. The calculated spectra clearly reflect the well-known dependence of nanoparticle optical properties viz. the resonance wavelength, the extinction cross-section, and the ratio of scattering to absorption, on the nanoparticle dimensions. A systematic quantitative study of the various trends is presented. By increasing the size of gold nanospheres from 20 to 80 nm, the magnitude of extinction as well as the relative contribution of scattering to the extinction rapidly increases. Gold nanospheres in the size range commonly employed ( approximately 40 nm) show an absorption cross-section 5 orders higher than conventional absorbing dyes, while the magnitude of light scattering by 80-nm gold nanospheres is 5 orders higher than the light emission from strongly fluorescing dyes. The variation in the plasmon wavelength maximum of nanospheres, i.e., from approximately 520 to 550 nm, is however too limited to be useful for in vivo applications. Gold nanoshells are found to have optical cross-sections comparable to and even higher than the nanospheres. Additionally, their optical resonances lie favorably in the near-infrared region. The resonance wavelength can be rapidly increased by either increasing the total nanoshell size or increasing the ratio of the core-to-shell radius. The total extinction of nanoshells shows a linear dependence on their total size, however, it is independent of the core/shell radius ratio. The relative scattering contribution to the extinction can be rapidly increased by increasing the nanoshell size or decreasing the ratio of the core/shell radius. Gold nanorods show optical cross-sections comparable to nanospheres and nanoshells, however, at much smaller effective size. Their optical resonance can be linearly tuned across the near-infrared region by changing either the effective size or the aspect ratio of the nanorods. The total extinction as well as the relative scattering contribution increases rapidly with the effective size, however, they are independent of the aspect ratio. To compare the effectiveness of nanoparticles of different sizes for real biomedical applications, size-normalized optical cross-sections or per micron coefficients are calculated. Gold nanorods show per micron absorption and scattering coefficients that are an order of magnitude higher than those for nanoshells and nanospheres. While nanorods with a higher aspect ratio along with a smaller effective radius are the best photoabsorbing nanoparticles, the highest scattering contrast for imaging applications is obtained from nanorods of high aspect ratio with a larger effective radius.

Absorption↗

Interrelation of tissue temperature versus flow velocity in two different kinds of temperature controlled catheter radiofrequency energy applications.

UNLABELLED: The influence of blood flow cooling down the energy delivering electrode during temperature controlled radiofrequency energy application is an important factor for ablation success. In this experimental in-vitro study, using tempered saline as blood equivalent, we observed a highly significant increase in tissue temperature, lesion depth and required energy amount with increasing flow velocity. Second, we found significant deeper lesions with use of pulsed radiofrequency energy application compared to continuous application. We conclude that, even with lower electrode temperatures, success can be achieved dependent on the local blood flow velocity, and deeper lesions can be created with the use of pulsed radiofrequency energy application. BACKGROUND: Success in temperature-controlled radiofrequency (RF) catheter ablation of arrhythmogenic areas in human hearts depend largely (among others) on the size of the electrode, developed pressure of electrode against tissue, as well as on the localization of the thermistor sensor within the electrode. In addition, the blood flow velocity at various sites of ablation is an important factor for the calculation of heat transport from the electrode, which obviously has not been given much consideration of in the past. The aim of the present in-vitro study, therefore, was to evaluate this important factor's influence on the temperature developed at the electrode and within the myocardial tissue. METHODS AND RESULTS: All experiments were carried out in a bath containing NaCl solution at 37 degrees C. Four different flow velocities were applied (0, 110, 180, 320 ml/cm2 *min). During and after temperature-controlled unipolar radiofrequency energy delivery (60 degrees C, 40 sec) the electrode temperature, the tissue temperature 5 mm in depth, and the total energy delivered were measured, as well as the actual depth of the lesion. The amount of energy applied to the electrode was regulated by the thermosensor in the electrode to obtain a maximum temperature of 60 degrees C. Two different kinds of radiofrequency energy delivery have been used: (1) continuous radiofrequency energy delivery as usual regarding clinical use, (2) pulsed radiofrequency energy delivery with a duty cycle length of 10 ms and a pause of at least the same duration during two consecutive duty cycles. At pulsed radiofrequency energy application, the energy for each duty cycle was held constant during delivery. The amount of pulses delivered to the electrode was regulated by the electrode's thermosensor. With both modes of radiofrequency energy delivery a uniform observation could be made. The more the flow velocity applied accelerated, the more the tissue temperature rose (R = 0.85; p < 0.00000001), and the lesion depth increased in spite of electrode temperature being held constant. The amount of the total energy delivered rose in proportion to the cooling down of the electrode dependent on the flow velocity (R = 0.69, p < 0.0000004). Steady-state temperatures had not been accomplished after 40 sec time. When energy was delivered at the pulsed mode, intramyocardial temperatures proved higher compared to the continuous mode with significant differences (p < 0.05) at comparable flow velocities applied between 180 and 320 ml/cm2*min and at same electrode temperatures. This resulted in significantly (p < 0.05) larger lesion depths in pulsed radiofrequency energy delivery. We suppose that this significant difference can be explained by a higher amount of total energy delivered at comparable electrode temperature in the pulsed mode as compared to the continuous mode.

Acceleration↗

[Application aids in pharmacotherapy].

The actual administration of pharmacotherapy is in most cases entirely up to the patient. Correct application can often be only achieved with application aids. They are already part of many preparations: printed blister packages, measures for dosing liquids, applicators for topical use, dosage sprays, and supports for eye drop containers. Special needs can be covered by additional application aids like dosage syringes for child medication, spacers for asthma sprays, devices for splitting or crunching tablets. Filling the medicines in containers better manageable by the patient, in week dispensers or week blisters, may also be crucial to guarantee correct dosing and regimen. Application aids often play a significant part in the success of a therapy. Needed are evidence based criteria for the selection of devices and instructions. Such criteria need to be developed because they are still largely lacking.

Drug Administration Schedule↗

Plasma levels of lidocaine and prilocaine after application of Oraqix, a new intrapocket anesthetic, in patients with advanced periodontitis.

BACKGROUND, AIMS: Oraqix, a new non-injection local anesthetic, lidocaine/prilocaine gel 5%, has been developed to provide pain relief in association with periodontal probing and scaling/root planing (SRP). The aim of this open study was to describe the plasma profiles of lidocaine and prilocaine following a single dose of Oraqix to patients with advanced periodontitis. METHODS: 10 patients with 18 to 28 teeth with pocket depths of at least 4 mm were included. Oraqix was applied in the pockets around all the teeth in the mouth by means of a blunt applicator. The total dose applied per patient was 0.9 to 3.5 g. Directly thereafter all the pockets were probed and 3 teeth subjected to SRP. The mouth was rinsed out with a glass of water 20-27 min after the application of the gel. Blood samples were collected before and up to 90 min after the start of application of Oraqix. RESULTS: Peak plasma concentrations of lidocaine (99-266 ng/ml) and prilocaine (46-118 ng/ml) occurred 20-40 min after the start of application. These levels were low compared to those reported to cause initial signs of CNS toxicity (5000-6000 ng/ml). Side-effects were few and mild local effects of short duration. DISCUSSION: In conclusion, there is a large safety margin with respect to systemic effects following the application of up to 3.5 g Oraqix in periodontal pockets.

Administration, Topical↗

Uniformity of sunscreen product application: a problem in testing, a problem for consumers.

BACKGROUND/AIMS: Testing of sunscreen products requires application of uniform films of product of defined thickness to test volunteers. In spite of the seeming importance of product application to defining sunscreen efficacy, there have been few studies determining how well uniformity is achieved. The purpose of this work was to evaluate the uniformity of sunscreen products of different sun protection factors (SPFs) and vehicles on a variety of substrates by in vitro testing techniques. The results of a variety of testing strategies are reported. METHODS: Five commercial sunscreen products of labelled SPF 4-50 were tested using a variety of substrates: Transpore Tape, Vitro-Skin trade mark, and lambskin condom. Two experienced sunscreen testers applied the products. In vitro SPFs were determined using an Optometric 290 analyser or an Optronic Laboratories OL754 spectroradiometer configured for this application. RESULTS: SPFs for several locations on each film applied to a substrate were determined and the mean SPF and RSD percentage of the mean calculated. For all substrates and testing techniques the average RSD percentage was 18.6, with a range of 10-40%. CONCLUSION: The expected uncertainty of SPF due to product application non-uniformity is 20% when applied under optimal test conditions. Clearly SPF tests reported by different laboratories must exhibit significant variability, because of product application non-uniformity.

Administration, Cutaneous↗

Applicant reactions to test score banding in entry-level and promotional contexts.

This series of field studies used a fairness framework to investigate applicant reactions to test score banding in 3 police selection contexts. Studies 1 (N = 85) and 2 (N = 369) involved applicants for entry-level positions, and Study 3 (N = 39) involved applicants for promotion. Across all 3 studies, race interacted with applicants' belief that banding is associated with affirmative action to affect measures of fairness and organizational outcomes such as attractiveness and perceived employee relations. Reactions were also related to applicants' perceived outcomes as a result of banding. Results are explained in terms of self-interest and suggest that reactions to banding are largely a function of the association of banding with affirmative action.

Adult↗

Job-specific applicant pools and national norms for personality scales: implications for range-restriction corrections in validation research.

This article compares variability in national norms to variability in job-specific applicant pools for personality scales. Across 23,231 job applicants for 111 jobs, we found that job-specific applicant pools were slightly less variable than broad normative data (by about 4%) based on a national norm sample of 40,474 job applicants. For some personality variables, the amount of variability reduction correlated with work characteristics as captured by the Data, People and Things scales of the Dictionary of Occupational Titles (US Department of Labor, 1977). Most correlations were small in magnitude. In general, the small reductions in job-specific applicant pool variability provide evidence that researchers' decisions to use manual norm group standard deviations in range restriction corrections has not appreciably inflated the personality-criterion relationships studied. Implications for attraction and gravitation to jobs are discussed.

Choice Behavior↗

Tissue distribution and kinetics of endogenous porphyrins synthesized after topical application of ALA in different vehicles.

The use of 5-aminolaevulinic acid (ALA) is gaining increasing attention for photosensitization in photodynamic therapy of superficially localized tumours. The aim of this work was to determine the kinetics of porphyrin generation in tissues after topical application of ALA delivered in different vehicles on the skin overlying the tumour and normal skin of mice. Maximal accumulation was found in tumour 3 h after ALA application in both cream and lotion preparations. Normal and overlying tumour skin tissues showed different kinetic patterns, reflecting histological changes when the latter is invaded by tumour cells. Liver, kidney, spleen and blood porphyrins also raised from basal levels, showing that ALA and/or ALA-induced porphyrins reach all tissues after topical application. During the first 24 h of ALA topical application, precursors and porphyrins are excreted by both urine and faeces. ALA lotion applied on the skin overlying the tumour induced higher accumulation of tumoural porphyrins than cream, and lotion applied on normal skin appeared to be the most efficient upon inducing total body porphyrins. This work has demonstrated the great influence of the formulation of ALA vehicle on penetration through the skin. Knowledge of the kinetics of porphyrin generation after different conditions of ALA application is needed for the optimization of diagnosis and phototherapy in human tumours.

Adenocarcinoma↗

Porphyrin formation in actinic keratosis and basal cell carcinoma after topical application of methyl 5-aminolevulinate.

Photodynamic therapy using topical methyl 5-aminolevulinate (MAL) is a new treatment modality for basal cell carcinoma (BCC) and actinic keratosis (AK). MAL induces endogenous porphyrins, which act as photosensitizers. Pharmacokinetic studies of the porphyrin-inducing effect of MAL creams (Metvix) applied in different concentrations (16-160 mg/g) and application times are presented. Surface fluorescence measurements were used to monitor porphyrin accumulation in 18 superficial BCCs and 32 AKs. For both lesion types, the fluorescence increased during the first 13 of 28 hours of continuous MAL application. A 20-fold site-to-site variation was observed, and there were no significant MAL concentration dependencies. The selectivity between lesions and normal skin was 10-fold during the first hours and decreased throughout the application time. Fluorescence microscopy images of tissue sections from 32 nodular BCCs were analyzed to calculate the porphyrin content in tumor tissue as a function of depth. Significant correlation to MAL concentration was seen within the tumors treated for 3 hours. Increase to 18-hour MAL application enhanced the fluorescence levels in superficial tumor layers, but not in deep layers. In conclusion, application of the 160 mg/g cream for 3 hours gave advantageous porphyrin distributions for all types of lesions.

Administration, Topical↗

Effect of harness application and postural changes on cardiovascular parameters of individuals with spinal cord injury.

STUDY DESIGN: Prospective assessment of cardiovascular parameters in individuals with spinal cord injury (SCI) in response to harness application and postural changes including orthostatic stress. OBJECTIVE: To evaluate arterial blood pressure and heart rate (HR) with and without harness application during sitting, supine, and standing positions in able-bodied and SCI individuals. METHODS: Measurements were obtained in all SCI research participants (n=11) before a locomotor training intervention and compared to data with able-bodied individuals (n=9). During standing, all research participants wore a harness and were suspended by an overhead, pneumatic body weight support system. RESULTS: Resting arterial blood pressure and HR in individuals with cervical SCI were significantly lower during sitting than in thoracic SCI and able-bodied individuals (P<0.05). Orthostatic stress significantly decreased arterial blood pressure only in individuals with cervical SCI (P<0.05). Harness application had no effect on cardiovascular parameters in able-bodied individuals, whereas diastolic blood pressure was significantly increased in those with SCI. Orthostatic changes in cervical SCI when sitting were ameliorated by harness application. However, while standing with harness, individuals with cervical SCI still developed orthostatic hypotension. CONCLUSIONS: Level of injury to the spinal cord influences baseline cardiovascular parameters. Application of harness in individuals with SCI could alter baseline cardiovascular parameters and the response to orthostatic stress. This should be carefully considered when assessing effects of therapeutic interventions using body weight support in individuals with SCI.

Adult↗

Synchrotron radiation circular dichroism spectroscopy of proteins and applications in structural and functional genomics.

The technique of Synchrotron Radiation Circular Dichroism (SRCD) spectroscopy and its advantages over conventional circular dichroism spectroscopy are described in this tutorial review, as well as recent applications of the technique in structural and functional genomics. Circular dichroism (CD) spectroscopy is a well-established method in biological chemistry and structural biology, but its utility can be limited by the low flux of the light source in the far ultraviolet and vacuum ultraviolet wavelength regions in conventional CD instruments. The development of synchrotron radiation circular dichroism (SRCD), using the intense light of a synchrotron beam, has greatly expanded the utility of the method, especially as a tool for both structural and functional genomics. These applications take advantage of the enhanced features of SRCD relative to conventional CD: the ability to measure lower wavelength data containing more electronic transitions and hence more structural information, the higher signal-to-noise hence requiring smaller samples, the higher intensity enabling measurements in absorbing buffers and in the presence of lipids and detergents, and the ability to do faster measurements enabling high throughput and time-resolved spectroscopy.This article discusses recent developments in SRCD instrumentation, software, sample preparation and methods of analyses, with particular emphasis on their applications to the study of proteins. These advances have led to new applications in structural genomics (SG), including the potential for fold recognition as a means of target selection and the examination of membrane proteins, a class of proteins usually excluded from SG programmes. Other SG uses include detection of macromolecular interactions as a screen for complex formation, and examination of glycoproteins and sugar components. In functional genomics (FG) new applications include screening for ligand binding as a means of identifying function, and examination of structural differences in mutant proteins as a means of gaining insight into function.

Circular Dichroism↗

Biotechnological applications for surface-engineered bacteria.

Display of heterologous proteins on the surface of micro-organisms, enabled by means of recombinant DNA technology, has become an increasingly popular strategy in microbiology, biotechnology and vaccinology. Both Gram-negative and Gram-positive bacteria have been investigated for potential applications. The present review will describe the most commonly used systems for bacterial display, with a focus on the biotechnology applications. Live bacterial vaccine-delivery vehicles have long been investigated through the surface display of foreign antigens and, recently, 'second-generation' vaccine-delivery vehicles have been generated by the addition of mucosal targeting signals, as a means to increase immune responses. Engineered bacteria have also the potential to act as novel microbial biocatalysts with heterologous enzymes immobilized as surface exposed on the bacterial cell surface. They provide the potential for new types of whole-cell diagnostic devices, since single-chain antibodies and other type of tailor-made binding proteins can be displayed on bacteria. Bacteria with increased binding capacity for certain metal ions can be created, and potential environmental or biosensor applications for such recombinant bacteria as biosorbents are being explored. Certain bacteria have also been employed to display various polypeptide libraries for use as devices in in vitro selection applications. Part of the present review has been devoted to a more in-depth description of a promising Gram-positive display system, i.e. Staphylococcus carnosus, and its applications. The review describes the basic principles of the different bacterial display systems and discusses current uses and possible future trends of these emerging technologies.

Bacteria↗