Radiofrequency catheter ablation of atrial flutter that elicits inappropriate implantable cardioverter defibrillator discharge.

The case of a patient with recurrent VT and an ICD is reported. After appropriate device discharges, the patient experienced 40 episodes of inappropriate shock therapy due to atrial arrhythmias confirmed as type I atrial flutter. Since programmed stimulation could reliably initiate atrial flutter, catheter ablation was performed. During delivery of RF current, atrial flutter terminated and was no longer inducible. The patient had no further inappropriate device discharges during 12 months of follow-up. In patients with ICDs suffering from recurrences of atrial flutter leading to inappropriate shock therapy, RF catheter ablation is an effective and curative approach.

Atrial Flutter↗

Antitachycardia pacing in patients with implantable cardioverter defibrillators: how many attempts are useful?

The purpose of this study was to determine the termination and acceleration rates for 1 to 6 attempts of antitachycardia pacing [ATP] delivered by ICD in order to terminate spontaneously occurring VTs. Twenty-four ICD recipients with active ATP programs, including a maximum of six ATP sequences and spontaneously occurring VTs during follow-up, were investigated. During a mean follow-up of 42 +/- 15 months (range, 17-63 months) 413 spontaneous VT episodes (17 +/- 14; range, 1-49 per patient) resulting in appropriate ATP delivery by the ICD occurred. ATP successfully terminated 328 episodes (80%) with a mean number of 1.6 +/- 1.1 pacing sequences. Eighty episodes (19%) were accelerated by ATP and 5 (1%) were unresponsive to ATP. The ATP success decreased until the third ATP sequence (59%-->31%-->24%), but increased again in the fourth to sixth attempt (46%-->46%-->29%). The acceleration rate increased from sequence one to sequence three (8%-->13%-->28%), but decreased significantly in further ATP attempts (19%-->0%-->0%). The mean time delays until redetection or termination after 4, 5, and 6 attempts of ATP were 22 +/- 5 seconds, 37 +/- 2 seconds, and 41 +/- 9 seconds, respectively. Nine patients (37%) used > or = 3 ATP attempts during follow-up and all of them had a therapeutic benefit from it. Five out of 13 VTs (38%) treated with > or = 4 attempts could ultimately be terminated by ATP. The results of this study demonstrate that the first ATP sequence is the most effective and that > 4 ATP attempts may be useful in a minority of patients. There seems to be a low risk of VT acceleration by the fourth to sixth ATP sequence. Because of the associated time delay, a high number of ATP attempts should only be programmed in patients with hemodynamically well-tolerated stable VTs.

Acceleration↗

A pitfall in using far-field bipolar electrograms in arrhythmia discrimination in a patient with an implantable cardioverter defibrillator.

Analysis of stored electrograms from bipolar far-field electrodes is considered to be useful in differentiating supraventricular from ventricular arrhythmias. A case of inappropriate ICD shocks for sinus tachycardia is presented whereby successive shocks caused marked widening of the ventricular electrograms. Analysis of these stored electrograms, recorded from far-field bipolar electrodes, gave the false impression of ventricular tachycardia. The widening was due to the current of injury effects, probably a consequence of the large amount of intervening myocardium between the bipoles. While analyzing recordings from far-field bipolar electrodes is generally useful, it is not always reliable, for changes in electrogram morphology, relative to baseline rhythm, may result from other factors like current of injury.

Adult↗

Ventriculoatrial conduction capability and prevalence of 1:1 retrograde conduction during inducible sustained monomorphic ventricular tachycardia in 305 implantable cardioverter defibrillator recipients.

Despite the advent of dual chamber ICDs, differentiation of VT (SMVT) with 1:1 VA conduction will remain a challenge. In this study, VA conduction capability and prevalence of inducible sustained monomorphic (SM) VT with 1:1 VA conduction was assessed in 305 ICD recipients. SMVT with a mean cycle length (CL) of 304 +/- 61 ms was induced in 161 (53%) patients. Twenty-six percent of the patients maintained 1:1 VA conduction to CL < or = 400 ms during incremental ventricular pacing, regardless of presenting tachyarrhythmia or presence of inducible SMVT. Among ten patients who had inducible SMVT with possible 1:1 VA conduction (based on SMVT CL comparable to the shortest CL associated with 1:1 retrograde conduction during ventricular pacing), all seven with available intracardiac tracings had documented 1:1 VA conduction during the induced SMVT--representing 4.4% of the patients with inducible SMVT (95% CI 1.2%-7.6%), and 2.3% of the entire ICD cohort (95% CI 0.6%-4.0%). We conclude that about one-fifth of ICD recipients possess 1:1 VA conduction to CL < or = 400 ms and that inducible SMVT with 1:1 VA conduction can be demonstrated in a small but nonnegligible proportion of ICD recipients. These data are relevant to the design of tachyarrhythmia-discrimination algorithms for dual chamber ICDs.

Adolescent↗

Inappropriate management of self-terminating ventricular arrhythmias by implantable cardioverter defibrillators despite a specific reconfirmation algorithm: a report of two cases.

Algorithms that attempt to reconfirm the presence of an arrhythmia prior to definite treatment have been implemented in ICDs to prevent inappropriate shock therapy due to self-terminating ventricular arrhythmias. Nevertheless, in two patients, clinically inappropriate shocks were delivered after spontaneous conversion of the arrhythmia despite the use of a specific reconfirmation algorithm. Reconfirmation criteria were met due to a premature ventricular complex causing a short cycle in the first patient and a long postextrasystolic pause in the second patient. To avoid inappropriate shock therapy due to self-terminating ventricular arrhythmias, further improvement of detection algorithms is required.

Algorithms↗

Electromagnetic interference from a muscle stimulation device causing discharge of an implantable cardioverter defibrillator: epicardial bipolar and endocardial bipolar sensing circuits are compared.

This case report is about two patients with two different types of ICDs who underwent electrical muscle stimulation (EMS) therapy. In one patient with an ICD that has epicardial screw-in bipolar sensing leads, electromagnetic interference (EMI) from the EMS device caused the delivery of an inappropriate ICD discharge. In a second patient with an ICD with endocardial true bipolar sensing, there was no evidence of EMI during the EMS therapy despite all of our attempts to reproduce it. The sensing circuits in the two different ICDs are compared.

Aged↗

Use of atrial and ventricular electrograms from a dual chamber implantable cardioverter defibrillator to elucidate a complex dysrhythmia.

Stored intracardiac electrograms provided by third-generation ICDs have proved their use in the analysis of the mechanism of tachydysrhythmic events. There are cases in which the analysis of ventricular electrograms is insufficient for the elucidation of certain dysrhythmias. The availability of atrial electrograms provided by dual chamber ICDs improves the diagnostic capability of electrogram analysis and could prove most useful especially in complex dysrhythmias.

Aged↗

Radiofrequency catheter ablation of atrioventricular junctional ("AV nodal") reentrant tachycardia in patients with implantable cardioverter defibrillators.

Catheter ablation of tachycardias has been undertaken successfully in patients with ICDs without damage to the ICD or lead. Ablation of the slow AV nodal pathway, however, is technically challenging because the lead of the ICD lies close to the ablation site. We report successful ablation of AV junctional reentrant tachycardia (AVJRT) in three patients with ICDs. In all cases, the ablation site was within a few millimeters of the ICD lead. The ablation was successful in all cases and did not cause damage to the ICD or lead. The patients have remained free of recurrence of AVJRT during a mean follow-up of 12 months.

Aged↗

Noise detection during bradycardia pacing with a hybrid nonthoracotomy implantable cardioverter defibrillator system: incidence and clinical significance.

The purpose of this study was to prospectively evaluate the incidence of noise detection during bradycardia pacing by an FDA approved hybrid nonthoracotomy ICD system. An illustrative case report which prompted this investigation is provided. Backup bradycardia pacing by tiered therapy cardioverter defibrillators has been useful in preventing postshock bradycardia and occasionally for chronic rate support in bradycardic patients. Unexplained "noise" detected by real-time telemetry has been previously described during bradycardia pacing by a device utilizing automatic gain control for sensing. Eighteen patients were prospectively evaluated for noise detection during ventricular pacing by the ICD. Real-time telemetry was analyzed with each patient: (1) supine, (2) supine with deep inspiration/expiration, (3) supine during Valsalva, and (4) during a change in position from supine to sitting. Analysis of pacing threshold and lead impedance was made in each patient. Eleven of 18 patients had noise detected on real-time telemetry during bradycardia pacing. In 10 patients this was noted during deep inspiration/expiration, in 2 during Valsalva maneuver, and in 5 with position change. There was no evidence in any patient of lead malfunction nor any difference in pacing threshold or lead impedance between patients with noise detected versus those without it. Noise detection by an approved hybrid ICD system is common and may be due to the automatic gain control which maximizes sensitivity during bradycardia pacing. This may lead to clinically significant events, with both suppression of bradycardia pacing and triggering of tachycardia therapy in the absence of ventricular tachyarrhythmias in pacemaker-dependent patients.

Aged↗

Laparoscopic hernia repair of an incisional hernia secondary to placement of an implantable cardioverter defibrillator.

We present the laparoscopic repair of a large incisional hernia secondary to placement of a subcostal ICD pulse generator. Laparoscopic repair of large incisional hernias provides a unique and technically feasible form of repair in the 2%-13% of patients who will develop an incisional hernia following an abdominal surgery. This form of hernia repair is associated with minimal morbidity and prompt resumption of patient activities and work.

Aged↗

Cellular phone interference testing of implantable cardiac defibrillators in vitro.

An in vitro study was undertaken to investigate the potential for cellular telephones to interfere with representative models of presently used ICDs. Digital cellular phones (DCPs) generate strong, amplitude modulated fields with pulse repetition rates near the physiological range sensed by the ICD as an arrhythmia. DCPs with Time Division Multiple Access (TDMA) pulsed amplitude modulation caused the most pronounced effect--high voltage firing or inhibition of pacing output of the ICDs. This electromagnetic interference (EMI) occurred only when the phones were within 2.3-5.8 cm of the ICD pulse generator that was submerged 0.5 cm in 0.18% saline. ICD performance always reverted to baseline when the cellular phones were removed from the immediate proximity of the ICD. Three models of ICDs were subjected to EMI susceptibility testing using two types of digital phones and one analog cellular phone, each operating at their respective maximum output power. EMI was observed in varying degrees from all DCPs. Inhibition of pacer output occurred in one ICD, and high voltage firing occurred in the two other ICDs, when a TDMA-11 Hz DCP was placed within 2.3 cm of the ICD. For the ICD that was most sensitive to delivering unintended therapy, inhibition followed by firing occurred at distances up to 5.8 cm. When a TDMA-50 Hz phone was placed at the minimum test distance of 2.3 cm, inhibition followed by firing was observed in one of the ICDs. EMI occurred most frequently when the lower portion of the monopole antenna of the cellular phone was placed over the ICD header.

Contraindications↗