PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Gaussian process”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

CaLMPhosKAN: prediction of general phosphorylation sites in proteins via fusion of codon aware embeddings with amino acid aware embeddings and wavelet-based Kolmogorov-Arnold network.

MOTIVATION: The mapping from codon to amino acid is surjective due to codon degeneracy, suggesting that codon space might harbor higher information content. Embeddings from the codon language model have recently demonstrated success in various protein downstream tasks. However, predictive models for residue-level tasks such as phosphorylation sites, arguably the most studied Post-Translational Modification (PTM), and PTM sites prediction in general, have predominantly relied on representations in amino acid space. RESULTS: We introduce a novel approach for predicting phosphorylation sites by utilizing codon-level information through embeddings from the codon adaptation language model (CaLM), trained on protein-coding DNA sequences. Protein sequences are first reverse-translated into reliable coding sequences by mapping UniProt sequences to their corresponding NCBI reference sequences and extracting the exact coding sequences from their GenBank format using a dynamic programming-based global pairwise alignment. The resulting coding sequences are encoded using the CaLM encoder to generate codon-aware embeddings, which are subsequently integrated with amino acid-aware embeddings obtained from a protein language model, through an early fusion strategy. Next, a window-level representation of the site of interest, retaining the full sequence context, is constructed from the fused embeddings. A ConvBiGRU network extracts feature maps that capture spatiotemporal correlations between proximal residues within the window. This is followed by a prediction head based on a Kolmogorov-Arnold network (KAN) using the derivative of gaussian wavelet transform to generate the inference for the site. The overall model, dubbed CaLMPhosKAN, performs better than the existing approaches across multiple datasets. AVAILABILITY AND IMPLEMENTATION: CaLMPhosKAN is publicly available at https://github.com/KCLabMTU/CaLMPhosKAN.

Codon↗

An objective method to define outlier optical coherence tomograms and repeatability of retinal nerve fibre layer measurements.

PURPOSE: To compare the variation in thickness and reflectivity of the retinal nerve fibre layer (RNFL), circumferentially and on repeated testing. METHODS: In 24 normal eyes and 38 eyes with different optic neuropathies or retinopathies, third-party optical coherence tomography (OCT) software defined the RNFL border based on the reflectivity pattern across the retina and also provided measurements of the mean reflectivity and total retinal thickness in addition to RNFL thickness. A new Gaussian filtering method was implemented so that the weight of the applied filter was varied for each of five individually repeated scans until an optimum weight filter was determined. RESULTS: The scans requiring the highest weight filter could be identified as 'outlier' scans that contained measurement or alignment artifacts. There was no difference in the weights of filtering needed for normal and abnormal eyes. The RNFL thickness and reflectivity, and retinal thickness were highly correlated with one another in normal and abnormal eyes. CONCLUSIONS: A new Gaussian filtering routine was devised that not only defined the most reproducible substructure of the RNFL for a given patient's eye, but also provided a new method of quantifying measurement variability and identification of scans with measurement or alignment artifacts.

Adult↗

Presampling, algorithm factors, and noise: considerations for CT in particular and for medical imaging in general.

CT scanners acquire noisy data at discrete sample positions. Typically, a convention of how to continue these data from discrete integer positions to the continuous domain must be applied during processing. We study the properties of three typical one-dimensional spatial domain interpolation algorithms in terms of a cost or quality factor Q. This figure of merit Q is a function of spatial resolution, data noise, and dose and is used to optimize detector design. Spatial resolution R is defined as either mean square width delta or as the full width at half maximum W of the point spread function (PSF). Our results show that a trapezoidal interpolation algorithm is optimal for the high resolution domain (relative to the detector aperture size g) and should be replaced by a triangular or Gaussian interpolation function for spatial resolutions of about 1.3g or larger; these result in bell-shaped PSFs. Assuming such a hybrid algorithm we find a 1.5-fold increase of Q2-this is equivalent to 50% improved dose usage-when smoothing the data to a spatial resolution of 3g or more compared to a highest resolution reconstruction. Therefore it is advisable to use detectors of one-third of the size of the desired spatial resolution W and to compensate for the 1.5-fold increase in Q2 by reducing dose by 33%. Under the presence of moderately sized septa (e.g., 10% of the spatial resolution element size) the benefit of optimizing still lies in the order of 30% improved dose usage; in that case the detector size g should be on the order of W/2 and a dose reduction of 23% can be achieved. Again, bell-shaped PSFs show a better tradeoff between noise and resolution for a given dose than rectangular-shaped PSFs. The general interpretation of our results is that the degree of freedom of choosing the weighting or interpolation function for a given resolution is large for small detectors and small for large detectors. Thus systems with small g have a higher potential of optimization compared to systems with large g. Similarly, detector binning, which corresponds to replacing g by 2g, should be avoided. Note that the figures reported correspond to a one-dimensional interpolation. Two-dimensional detectors typically separate and resulting quality factors can be easily obtained by multiplication. Then, Q2 is expected to improve by a factor of 1.52 without septa and by a factor of 1.32 with septa. This indicates that dose can be reduced by about 56% and about 41%, respectively. Our findings are general and not restricted to CT. They can be readily applied to medical or nonmedical imaging devices and digital detectors and they may also turn out to be useful in other fields.

Algorithms↗

Gaseous reaction mechanism of C2F radical with water.

The kinetic properties of the carbon-fluorine radicals are little understood except those of CFn (n =1-3). In this article, a detailed mechanistic study was reported on the gas-phase reaction between the simplest pi-bonded C2F radical and water as the first attempt to understand the chemical reactivity of the C2F radical. Various reaction channels are considered. The most kinetically competitive channel is the quasi-direct hydrogen-abstraction route forming P5 HCCF + OH. At the CCSD(T)/6-311+G(2d,2p)//B3LYP/6-311G(d,p)+ZPVE, CCSD(T)/6-311+G(3df,2p)//QCISD/6-311G(d,p)+ZPVE and Gaussian-3//B3LYP/6-31G(d) levels, the overall H-abstraction barriers (4.5, 4.7, and 4.2 kcal/mol) for the C2F + H2O reaction are comparable to the corresponding values (5.5, 3.7, and 5.7 kcal/mol) for the analogous C2H + H2O reaction. This suggests that C2F is a reactive radical like the extensively studied C2H, in contrast to the situation of the CF and CF2 radicals that have much lower reactivity than the corresponding hydrocarbon species. Thus, the C2F radical is expected to play an important role in the combustion processes of the carbon-fluorine chemistry. Furthermore, addition of a second H2O can catalyze the reaction with the H-abstraction barrier significantly reduced to a marginally zero value (0.5 kcal/mol). This is also indicative of the potential relevance of the title reactions in the low-temperature atmospheric chemistry.

Journal Article↗

Performance of short-time spectral parametric methods for reducing the variance of the Doppler ultrasound mean instantaneous frequency estimation.

To achieve an accurate estimation of the instantaneous turbulent velocity fluctuations downstream of prosthetic heart valves in vivo, the variability of the spectral method used to measure the mean frequency shift of the Doppler signal (i.e. the Doppler velocity) should be minimised. This paper investigates the performance of various short-time spectral parametric methods such as the short-time Fourier transform, autoregressive modelling based on two different approaches, autoregressive moving average modelling based on the Steiglitz-McBride method, and Prony's spectral method. A simulated Doppler signal was used to evaluate the performance of the above mentioned spectral methods and Gaussian noise was added to obtain a set of signals with various signal-to-noise ratios. Two different parameters were used to evaluate the performance of each method in terms of variability and accurate matching of the theoretical Doppler mean instantaneous frequency variation within the cardiac cycle. Results show that autoregressive modelling outperforms the other investigated spectral techniques for window lengths varying between 1 and 10 ms. Among the autoregressive algorithms implemented, it is shown that the maximum entropy method based on a block data processing technique gives the best results for a signal-to-noise ratio of 20 dB. However, at 10 and 0 dB, the Levinson-Durbin algorithm surpasses the performance of the maximum entropy method. It is expected that the intrinsic variance of the spectral methods can be an important source of error for the estimation of the turbulence intensity. The range of this error varies from 0.38% to 24% depending on the parameters of the spectral method and the signal-to-noise ratio.

Blood Flow Velocity↗

Translational free random walk of spins in the presence of a parabolic magnetic field.

The free random walk approach has been used to analyze the attenuation of the NMR signal due to spin dephasing in the presence of a constant and pulsed parabolic magnetic field. The spin echo sequence was chosen to examine the attenuation of the NMR signal resulting from self-diffusion. In the framework of the gaussian approach, the long-time limit calculations predict more pronounced diffusion weighting for the parabolic field than for linear magnetic field. Analytical results were obtained and compared with those from other approaches based on a variety of different of approximations.

Electromagnetic Fields↗

The 30 minutes decision-to-delivery interval for 'urgent' caesarean sections: an elusive target.

The aim of this audit was to evaluate whether the '30 minute decision-to-delivery interval' for 'urgent' caesarean section has shown consistent improvement with repeated audit within this unit. The audit dataset comprised a random sample of all urgent caesarean sections carried out in 2004 classified as 'urgent', i.e. to be completed in 30 min. Nearly one-third of caesarean sections recorded on the delivery suite database as 'urgent' were incorrectly coded. A personal review of case notes was undertaken to ensure accurate data capture. Delivery suite data was analysed by post-hoc modelling of a 'normal' (Gaussian) distribution. The proportion of true 'urgent' caesarean sections completed in 30 min was 50% and some 90% of women were delivered within 40 min. The data were normally distributed, with non-random events, accounted for 25% of the variability. A model for 'urgent' caesarean section, accommodating random and non-random factors closely matched the audit data. We conclude that non-random, institutional, factors reflecting overall delivery suite activity adversely effect the decision-to-delivery interval regardless of the performance of personnel and processes within a delivery suite.

Anesthesia, Obstetrical↗

Temperature dependence of spatially heterogeneous dynamics in a model of viscous silica.

Molecular dynamics simulations are performed to study spatially heterogeneous dynamics in a model of viscous silica above and below the critical temperature of the mode coupling theory, T(MCT) . Specifically, we follow the evolution of the dynamic heterogeneity as the temperature dependence of the transport coefficients shows a crossover from non-Arrhenius to Arrhenius behavior when the melt is cooled. It is demonstrated that, on intermediate time scales, a small fraction of oxygen and silicon atoms are more mobile than expected from a Gaussian approximation. These highly mobile particles form transient clusters larger than that resulting from random statistics, indicating that the dynamics are spatially heterogeneous. An analysis of the clusters reveals that the mean cluster size is maximum at times intermediate between ballistic and diffusive motion, and the maximum size increases with decreasing temperature. In particular, the growth of the clusters continues into the crossover to Arrhenius behavior for the transport coefficients. These findings imply that the structural relaxation in silica cannot be understood as a statistical bond breaking process. Although the mean cluster sizes for silica are at the lower end of the spectrum of values reported in the literature for other model liquids, we find that spatially heterogeneous dynamics in models of strong and fragile glass formers are similar on a qualitative level. However, unlike the results for fragile liquids, we show that correlated particle motion along quasi-one-dimensional, stringlike paths is of little importance for the structural relaxation in this model of silica, suggesting that stringlike motion is suppressed by the presence of a network structure. To study transient clusters of localized particles, we calculate a generalized susceptibility corresponding to the self-part of a four-point time dependent density correlation function. We find that this generalized susceptibility is maximum on the time scale of the structural relaxation, where a strong increase of the peak height indicates a growing length of spatial correlations between localized particles upon cooling. Characterizing the local structural environments of the most mobile and the most immobile particles, respectively, we show that high particle mobility is facilitated by, but not limited to, the vicinity of defects in the network structure.

Journal Article↗

Analysis of hyperspectral fluorescence images for poultry skin tumor inspection.

We present a hyperspectral fluorescence imaging system with a fuzzy inference scheme for detecting skin tumors on poultry carcasses. Hyperspectral images reveal spatial and spectral information useful for finding pathological lesions or contaminants on agricultural products. Skin tumors are not obvious because the visual signature appears as a shape distortion rather than a discoloration. Fluorescence imaging allows the visualization of poultry skin tumors more easily than reflectance. The hyperspectral image samples obtained for this poultry tumor inspection contain 65 spectral bands of fluorescence in the visible region of the spectrum at wavelengths ranging from 425 to 711 nm. The large amount of hyperspectral image data is compressed by use of a discrete wavelet transform in the spatial domain. Principal-component analysis provides an effective compressed representation of the spectral signal of each pixel in the spectral domain. A small number of significant features are extracted from two major spectral peaks of relative fluorescence intensity that have been identified as meaningful spectral bands for detecting tumors. A fuzzy inference scheme that uses a small number of fuzzy rules and Gaussian membership functions successfully detects skin tumors on poultry carcasses. Spatial-filtering techniques are used to significantly reduce false positives.

Animals↗

Discriminability metric based on human contrast sensitivity.

We evaluated a metric for predicting the discriminability of different digitized versions of alphanumeric characters. The metric is based on the assumption that there exists a visual filter such that discriminability is monotonic with the contrast energy in the visually filtered difference between stimuli. To test this hypothesis, we presented two same or different digital versions of a master character and asked subjects to indicate whether the characters were the same or different in a forced-choice procedure with feedback. The filtered contrast energy difference was calculated by convolving the difference between stimulus pairs with filters derived from published human contrast sensitivity functions, following an initial nonlinear transformation of stimulus intensity, and summing the squared result. For some types of stimulus difference, such as contrast quantization errors and Gaussian blurring, performance on discrimination tasks is monotonically related to the contrast energy of the filtered difference vector. The results are consistent with the hypothesis that there exists a single psychometric function that can predict the discriminability of different digitized versions of characters when displayed on various devices.

Contrast Sensitivity↗

Discrepancy analysis, communication, and feedback for cytotechnologist quality improvement of nongynecologic cytopathology.

The Clinical Laboratory Improvement Amendments of 1988 (CLIA '88) detail the requirements for the cytotechnologist (CT) who evaluates gynecologic cytopathology specimens. However, the role of the CT in nongynecologic cytopathology is not clearly defined. Furthermore, non gynecologic cytopathology cases are diverse and the screening, interpretative, and diagnostic issues may be quite different from the gynecologic cases. At our institution, the CT and pathologist review nongynecologic cytopathology cases. Since CLIA '88 does not require the CT to screen nongynecologic cytopathology cases, there are few guidelines for quality assessment or quality improvement for the CT regarding nongynecologic cytopathology cases. To provide better understanding of the expectations of the CT and the needs of the pathologist, we developed a system comparing the CT's interpretation to the pathologist's interpretation as a means for enhanced communication and feedback. Using our Laboratory Information System (LIS), we generate a daily report that lists all cases with discrepancy in diagnoses between the CT and pathologist. The general supervisor reviews this report for diagnostic discrepancy in each case. To determine the degree of discrepancy, numerical values are assigned to each primary interpretation. Minor discrepancies are defined as differences less than +/-2.0. Major discrepancies are defined as differences greater than or equal to +/-2.0. For the entire laboratory, the overall percentage of concordant cases was consistently above 80% for each of the 6 mo analysis. Regarding the monthly discrepancies, the proportion of minor discrepancies ranged from 11.09% to 15.44% and the proportion of major discrepancies ranged from 1.40% to 3.56%. The frequency distribution of discrepancies by degree approximates a normal (Gaussian) curve and serves as baseline information that may be used for comparison when there are changes in practice or personnel. The CTs attend slide review sessions conducted by the general supervisor for discussion of cases with major discrepancies. The discrepancy data from individual CTs are useful in counseling and recommending areas for improvement. As the CT and pathologist work cooperatively and in tandem, our system allows for a mechanism by which the expectations and needs of pathologist are communicated to the CT more effectively. We believe our process is a fundamental step in improving CT performance in Nongynecologic cytopathology and keeps the CT informed of complexities of nongynecologic cytopathology.

Clinical Laboratory Information Systems↗

Pipelining of Fuzzy ARTMAP without matchtracking: correctness, performance bound, and Beowulf evaluation.

Fuzzy ARTMAP neural networks have been proven to be good classifiers on a variety of classification problems. However, the time that Fuzzy ARTMAP takes to converge to a solution increases rapidly as the number of patterns used for training is increased. In this paper we examine the time Fuzzy ARTMAP takes to converge to a solution and we propose a coarse grain parallelization technique, based on a pipeline approach, to speed-up the training process. In particular, we have parallelized Fuzzy ARTMAP without the match-tracking mechanism. We provide a series of theorems and associated proofs that show the characteristics of Fuzzy ARTMAP's, without matchtracking, parallel implementation. Results run on a BEOWULF cluster with three large databases show linear speedup as a function of the number of processors used in the pipeline. The databases used for our experiments are the Forrest CoverType database from the UCI Machine Learning repository and two artificial databases, where the data generated were 16-dimensional Gaussian distributed data belonging to two distinct classes, with different amounts of overlap (5% and 15%).

Databases as Topic↗

The influence of stimulus envelope and fine structure on the binaural masking level difference.

A masking level difference (MLD) paradigm was used to investigate the influence of stimulus envelope and stimulus fine-structure characteristics on monaural and binaural hearing. The degree of masker envelope fluctuation was manipulated by selecting narrow-band noises (50 Hz) on a continuum of values of the normalized fourth moment of the envelope. The noises were specified as low-noise noise (LNN), medium-noise noise (MNN), and high-noise noise (HNN). Fine-structure cues were studied by measuring thresholds at 500 and 4000 Hz, regions in which the availability of such cues to the auditory system differ substantially. In addition, thresholds were measured for Gaussian noise maskers (GN) and for maskers having a flat magnitude spectrum, termed equal-magnitude noise (EMN) maskers. The results indicated lower NoSo thresholds for LNN than for the other four masker types. Furthermore, there were no differences in threshold for maskers having moderate and high degrees of envelope fluctuation (MNN and HNN). The NoS pi thresholds were not significantly different across masker type and were characterized by large individual differences among the seven listeners. The results are considered in relation to models of monaural and binaural processing. Consistent with previous reports, the results indicate that binaural detection depends on interaural differences in the stimulus envelope and fine structure at low frequencies and changes in the envelope at high frequencies.

Adult↗

Using HOS for characterization of periodical and time-varying waveform.

We applied an approach based on high order statistics (HOS) to classification of time series. This is different from most of the prior analyses in which signal features have been compared. In our approach, we investigate an input signal deformed non-linearly in time and contaminated with additional different forms of noise, e.g. Gaussian, non-Gaussian and their mixed form. The bispectrum-averaging technique (third order statistics) which preserves information about both amplitude and phase of the Fourier transform is studied for the reconstruction of the predictable waveform. The technique does require neither an initial estimate nor a peak-to-peak synchronization of the realizations. Thus, the normal waveform is considered ideally to be smooth and entirely predictable. The residual is characterized by subtracting the predictable part from the original waveform. Under non-linearity assumption, we propose that the Volterra process tool is suitable for analysis and differentiation between the patterns contained in the time series residual. We present and classify some results of the output of the linear transfer function of the process. The approach is numerically tested with the use of computer-generated data. Its effectiveness in dealing with electrocardiogram (ECG)-related data is also demonstrated.

Computer Simulation↗

Room temperature microspectrofluorimetry as a useful tool for studying the assembly of the PSII chlorophyll-protein complexes in single living cells of etiolated Euglena gracilis Klebs during the greening process.

The assembly kinetics of the PSII chlorophyll-protein complexes was followed during the greening of Euglena gracilis by microspectrofluorimetry in vivo, at room temperature, on single living cells. The study was correlated to micro- and submicroscopic events accompanying the proplastid to chloroplast transformation and with the immunolocalization of the LHCPII. Etiolated cells of Euglena gracilis were grown in darkness in Mego's heterotrophic liquid medium under shaking at 25+/-1 degrees C. At the stationary phase of growth, they were exposed to continuous light (330 micromol m(-2) s(-1)) for 72 h. The analyses were carried out on samples collected at different times of illumination. Microspectrofluorimetric data were recorded in the 620-780 nm range (excitation at 436 nm) and were resolved into Gaussian components corresponding to the reaction centres (RCII) and the inner antennae (CP(43-47)) of the PSII and LHCPII. From the RCII/CP(43-47) and LHCPII/PSII ratios, it was inferred that (1) a disconnection between RCII and CP(43-47) syntheses occurs during the lag phase of chloroplast differentiation, RCII being synthesized before the inner antennae. This results in the accumulation of uncoupled PSII Chl-protein complexes; (2) after lag phase, the RCII and CP(43-47) syntheses are connected one to another; (3) the freshly synthesized LHCPII complexes are immediately assembled with the PSII, suggesting that the outer antennae always maintain the form bound to PSII. Micro- and submicroscopical observations and LHCPII immunolocalization were in agreement. These data suggest that microspectrofluorimetry may constitute a useful non-destructive tool for studying the assembly kinetics of PSII, under fully physiological life conditions.

Animals↗

Analysis of fMRI data by blind separation of data in a tiny spatial domain into independent temporal component.

Independent Component Analysis (ICA) is a promising tool for the analysis of functional magnetic resonance imaging (fMRI) time series. In these studies, mostly assumed is a spatially independent component map of fMRI data (spatial ICA). In this paper, we assume that the temporal courses of the signal and noises are independent within a Tiny spatial domain (temporal ICA). Then with fast-ICA algorithm, spatially neighboring fMRI data were blindly separated into several temporal courses and were preassumed to be formed by a signal time course and several noise time courses where the signal has the largest correlation coefficient with the reference signal. The final functional imaging was completed for the signals obtained from each voxel. Simulations showed that compared with the spatial ICA method, the new temporal ICA method is more effective than the spatial ICA in detecting weak signal in a fMRI dataset. As background noise, the simulations include simulated Gaussian noise and fMRI data without stimulation. Finally, vivo fMRI tests showed that the excited areas evoked by a visual stimuli are mainly in the region of the primary visual cortex and that evoked by auditory stimuli are mainly in the region of the primary temporal cortex.

Algorithms↗

No effect of cigarette smoking on electroencephalographic nonlinearity.

The Gaussian surrogate-date procedure was applied to the measurement of the effect of cigarette smoking on the dimensional complexity of normal, resting EEG. Evidence of significant nonlinearity in the EEG was obtained, replicating previous results. However, unlike EEG dimensional complexity, EEG nonlinearity (difference between original and surrogate data) was not affected by smoking. This indicates that, under resting conditions, smoking/nicotine may have a modulating effect on input from the reticular activating system, with such input having a global, linearizing effect on cortical dynamics. Nonlinear dynamics resulting from intracortical processes appear not to be affected.

Adult↗

Assessment of the radiological impacts of a zircon sand processing plant.

The paper presents the results of a study on radiological impacts resulting from a zircon sand processing plant located in the North-Eastern part of Italy. Activity concentrations of radionuclides found in materials associated with this industrial process are presented as well as the results of the assessment of the annual effective doses to the workers and the members of the public. Gamma-spectrometric analyses were performed on "raw" sands, end-products, and soils sampled near the plant. Thermoluminescent dosimeters, electric pumps and electret ion chambers were used to measure the external irradiation, the indoor dust concentrations and the radon concentrations, respectively. The ground-level air concentration of radioactive particulate near the plant and the deposition of particulate matter were estimated by a Gaussian model (ISCLT3). Finally, the annual effective doses, calculated as provided for by Directive 96/29/Euratom, were estimated to be 1.7 mSv y(-1) for workers and 4.4 microSv y(-1) for members of the public.

Air Pollutants, Radioactive↗