PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,135 records · Page 63Linked to original sources

[Analysis of compound-specific carbon isotopic compositions of trace-level volatile organic compounds in aqueous phases].

A method combining solid phase microextraction (SPME) with cryofocus technique was developed for the compound-specific carbon isotope analysis of volatile organic compounds in aqueous phase. The detection limit was 10 times better than the conventional SPME method. Under the optimized analytical conditions, aqueous samples of trichloroethylene/perchloroethylene (TCE/PCE) (20 microg/L) and benzene/toluene (10 microg/L) were analyzed. The delta 13C fractionation compared to pure-phase and headspace analysis was less than 0.5 per thousand. The standard deviation was 0.3 per thousand. The method was applied to the delta 13C analysis of PCE in a contaminated groundwater in Beijing. The delta 13C values of PCE on site B408 (source area) and site B230 (spilled area) were -37.8 per thousand and -34.45 per thousand, respectively. The enriched delta 13C value on site B230 may be caused by biodegradation or chemical reaction in groundwater. The tested delta 13C value of benzene, toluene, trichloroethylene and perchloroethylene from different manufacturers were different, indicating that carbon isotope analysis is a useful method to distinguish the sources of contaminants in the environment. This method is simple, easy to use and highly sensitive. It is suitable for the compound-specific carbon isotope analysis of volatile organic compounds in aqueous phase.

Benzene↗

Optimization of the SPME parameters and its online coupling with HPLC for the analysis of tricyclic antidepressants in plasma samples.

Solid-phase microextraction (SPME)-liquid chromatography (LC) is used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. Extraction conditions are optimized using a 2(3) factorial design plus a central point to evaluate the influence of the time, temperature, and matrix pH. A Polydimethylsiloxane-divinylbenzene (60-mum film thickness) fiber is selected after the assessment of different types of coating. The chromatographic separation is realized using a C(18) column (150 x 4.6 mm, 5-microm particles), ammonium acetate buffer (0.05 mol/L, pH 5.50)-acetonitrile (55:45 v/v) with 0.1% of triethylamine as mobile phase and UV-vis detection at 214 nm. Among the factorial design conditions evaluated, the best results are obtained at a pH 11.0, temperature of 30 degrees C, and extraction time of 45 min. The proposed method, using a lab-made SPME-LC interface, allowed the determination of tricyclic antidepressants in in plasma at therapeutic concentration levels.

Antidepressive Agents, Tricyclic↗

Analysis of trace levels of pesticides in rainwater by SPME and GC-tandem mass spectrometry after derivatisation with PFBBr.

Solid-phase microextraction (SPME) was used for the analysis of some pesticides (bromoxynil, chlorotoluron, diuron, isoproturon, 2,4-MCPA, MCPP and 2,4-D) in rainwater after derivatisation with PFBBr and gas chromatography-ion trap mass spectrometry. The derivatisation procedure was optimized by testing different methods: direct derivatisation in the aqueous phase followed by SPME extraction, on-fibre derivatisation and derivatisation in the injector. The best result was obtained by headspace coating the PDMS/DVB fibre with PFBBr for 10 min followed by direct SPME extraction for 60 min at 68 degrees C (pH 2 and 75% NaCl). Good detection limits were obtained for all the compounds: these ranged between 10 and 1,000 ng L-1 with a relatively high uncertainty due to the combination of derivatisation and SPME extraction steps. The optimized procedure was applied to the analysis of pesticides in rainwater and results obtained shows that this method is a fast and simple technique to assess the spatial and temporal variations of concentrations of pesticides in rainwater.

2,4-Dichlorophenoxyacetic Acid↗

Fast and sensitive environmental analysis utilizing microextraction in packed syringe online with gas chromatography-mass spectrometry: determination of polycyclic aromatic hydrocarbons in water.

A new sensitive, selective, fast and accurate technique for online sample preparation was developed. Microextraction in a packed syringe (MEPS) is a new miniaturised, solid-phase extraction (SPE) technique that can be connected online to GC or LC without any modifications. In MEPS approximately 1mg of the solid packing material is inserted into a syringe (100-250 ml) as a plug. Sample preparation takes place on the packed bed. The bed can be coated to provide selective and suitable sampling conditions. The new method is very promising. It is very easy to use, fully automated, of low cost and rapid in comparison with previously used methods. The determination of polycyclic hydrocarbons (PAHs) in water was performed using MEPS as sample preparation method online with gas chromatography and mass spectrometry (MEPS-GC-MS). The results from MEPS as sample preparation were compared with other techniques such as stir bar sorptive extraction (SBSE) and solid-phase microextraction (SPME). The method was validated and the standard curves were evaluated by the means of quadratic regression and weighted by inverse of the concentration: 1/x for the calibration range 5-1,000 ng/L. The MEPS applied polymer (silica-C8) could be used more than 400 times before the syringe was discarded. The extraction recovery was about 70%. The results showed close correlation coefficients (R>0.998) for all analytes in the calibration range studied. The accuracy of MEPS-GC-MS was between 90 and 113% and the inter-day precision (n=3 days), expressed as the relative standard deviation (RSD%), was 8-16%. MEPS reduced the handling time by 30 and 100 times compared to SPME and SBSE, respectively.

Gas Chromatography-Mass Spectrometry↗

Comparison between solid-phase extraction methods for the chromatographic determination of organophosphorus pesticides in water.

A solid-phase microextraction (SPME) procedure has been developed to extract eight organophosphorus pesticides (OPs) in water and the method was compared with a conventional solid phase extraction (SPE) technique. The extracted OPs were analyzed by gas chromatography using thermionic specific detection. Both extraction methods presented linear calibration at least over the concentration range investigated (100 to 1000 ng x mL(-1) for SPE and 1 to 100 ng x mL(-1) for SPME). SPME method presented higher sensitivity than SPE. The quantitation limits were between 0.1 to 1.0 ng x mL(-1) for SPME depending upon the analyte, and 100 ng x mL(-1) for SPE. The precision, as measured by the standard deviations (RSD), were in the range 3.6% to 5.8% for SPME and 2.4% to 9.2% for SPE. Along with the feature of being a solvent - free sampling technique, SPME offers additional benefits due to its high sensitivity, simplicity, and small size sample required (typically: SPE - 500 mL, SPME - 5 mL).

Calibration↗

New developments in SPME, Part 1: The use of vapor-phase deprotonation and on-fiber derivatization with alkylchloroformates in the analysis of preparations containing amphetamines.

Due to their high polarity and low vapor pressure, most amine salts of amphetamine-type drugs are not directly amenable to headspace recovery using solid-phase microextraction (SPME). Described in this article is a simple vapor-phase procedure for the conversion of solid drug salt samples into their free bases by the use of triethylamine. This process can be conducted simultaneously with headspace SPME, the outcome being that solid drug salts can be sampled directly for GC-MS without the need for dissolution and chemical processing. Potential applications for this methodology include the noninvasive recovery of drug traces from objects such as banknotes and garments. This new process for recovery of amphetamine-type drugs has been combined with on-fiber derivatization using alkylchloroformates. This extra step was included to improve the chromatographic performance of analytes and allow for the resolution of drug enantiomers.

Amphetamines↗

Thin-film microextraction.

The properties of a thin sheet of poly(dimethylsiloxane) (PDMS) membrane as an extraction phase were examined and compared to solid-phase microextraction (SPME) PDMS-coated fiber for application to semivolatile analytes in direct and headspace modes. This new PDMS extraction approach showed much higher extraction rates because of the larger surface area to extraction-phase volume ratio of the thin film. Unlike the coated rod formats of SPME using thick coatings, the high extraction rate of the membrane SPME technique allows larger amounts of analytes to be extracted within a short period of time. Therefore, higher extraction efficiency and sensitivity can be achieved without sacrificing analysis time. In direct membrane SPME extraction, a linear relationship was found between the initial rate of extraction and the surface area of the extraction phase. However, for headspace extraction, the rates were somewhat lower because of the resistance to analyte transport at the sample matrix/headspace barrier. It was found that the effect of this barrier could be reduced by increasing either agitation, temperature, or surface area of the sample matrix/headspace interface. A method for the determination of PAHs in spiked lake water samples was developed based on the membrane PDMS extraction coupled with GC/MS. A linearity of 0.9960 and detection limits in the low-ppt level were found. The reproducibility was found to vary from 2.8% to 10.7%.

Chromatography, Gas↗

Identification by gas chromatography-mass spectrometry of the volatile organic compounds emitted from the wood-rotting fungi Serpula lacrymans and Coniophora puteana, and from Pinus sylvestris timber.

Volatile organic compounds (VOCs) emitted by two wood-rotting basidiomycete fungi, Serpula lacrymans (dry rot fungus) and Coniophora puteana (cellar fungus), and the timber of Pinus sylvestris (Scots pine), were identified. Several volatile collection techniques were employed including dichloromethane solvent extraction, solid-phase microextraction (SPME) and thermal desorption of VOCs entrained on Tenax GR. In addition, a new method of solid sample injection (SSI) is described which utilises a low injector temperature and an all-glass deactivated injector liner designed to minimise both the formation of pyrolysis products and analyte degradation. All the volatile compounds collected were analysed using electron impact capillary gas chromatography-mass spectrometry (GC-MS) on HP-5, HP-Innowax and beta-cyclodextrin columns. SSI and Tenax thermal desorption were found to be the most effective extraction methods. A total of 19 VOCs were observed from S. lacrymans grown on glass slides and pine, 15 from C. puteana grown on glass slides and 12 from P. sylvestris timber. S. lacrymans was found to emit, in low abundance, six unique VOCs, of which 2-methylbutanal was the greatest. The major volatile compound emitted by S. lacrymans was 1-octen-3-ol, which was also found in lower abundance from C. puteana. Six VOCs, including diethylene glycol and 4-methyl methylbenzoate, were found to be unique to C. puteana, all in medium abundance: From P. sylvestris, the major volatiles identified were S-alpha-pinene and 3-carene.

Basidiomycota↗

Analysis of odorous trichlorobromophenols in water by in-sample derivatization/solid-phase microextraction GC/MS.

The simultaneous determination of several odorous trichlorobromophenols in water has been carried out by an in-sample derivatization headspace solid-phase microextraction method (HS-SPME). The analytical procedure involved their derivatization to methyl ethers with dimethyl sulfate/NaOH and further HS-SPME and gas chromatography-mass spectrometry (GC/MS) determination. Parameters affecting both the derivatization efficiency and headspace SPME procedures, such as the selection of the SPME fiber coating, derivatization-extraction time and temperature, were studied. The commercially available polydimethylsiloxane (PDMS) 100 microm and Carboxen-polydimethylsiloxane-divinylbenzene (CAR-PDMS-DVB) fibers appeared to be the most suitable for the simultaneous determination of these compounds. The precision of the HS-SPME/GC/MS method gave good relative standard deviations (RSDs) run-to-run between 9% and 19% for most of them, except for 2,5-diCl-6-Br-phenol, 2,6-diCl-3-Br-phenol and-2,3,6-triBr-phenol (22%, 25% and 23%, respectively). The method was linear over two orders of magnitude, and detection limits were compound dependent but ranged from 0.22 ng/l to 0.95 ng/l. The results obtained for water samples using the proposed SPME procedure were compared with those found with the EPA 625 method, and good agreement was achieved. Therefore, the in-sample derivatization HS-SPME/GC/MS procedure here proposed is a suitable method for the simultaneous determination of odorous trichlorobromophenols in water.

Dimethylpolysiloxanes↗

Microextraction of drugs.

This review will attempt to provide an overview as well as a theoretical and practical understanding of the use of microextraction technologies for drug analysis. The majority of the published reports to date focus on the use of fibre solid-phase microextraction and so the review is significantly focused on this technology. Other areas of microextraction such as single drop and solvent film microextraction are also described. Where there are insufficient examples in the literature to illustrate important concepts, examples of non-drug analyses are presented. The review is intended for readers new to the field of microextraction or its use in drug extraction, but also provides an overview of the most recent advances in the field which may be of interest to more experienced users. Particular emphasis is placed on the effect various sample matrices have on extraction characteristics.

Adsorption↗

Assessing the aquatic hazard of commercial hydrocarbon resins.

Hydrocarbon resins are used to modify polymer products to achieve desired functional properties for a diverse range of products. These complex hydrocarbon-based mixtures are typically poorly soluble in water. However, resins may leach lower-molecular-weight monomers or impurities upon contact with water, thus posing a potential hazard to the aquatic environment. The bioavailability and toxicity of leachable constituents of four solid and three liquid resins were evaluated by analyzing water-accommodated fractions prepared with each resin, using biomimetic solid phase microextraction (SPME) techniques. Liquid resins exhibited concentrations of bioavailable constituents that were sufficiently elevated to cause acute toxicity to the aquatic organism Daphnia magna. All solid resins exhibited lower bioavailable concentrations of leachable constituents that were unlikely to pose an aquatic toxicity concern. Since observed toxicity of both resin types was generally consistent with bioavailable concentrations determined using SPME fiber measurements, it is concluded that this approach provides a convenient in vitro screening tool that can help reduce the use of animal testing in environmental hazard assessment of complex hydrocarbon-based substances.

Animal Testing Alternatives↗

Interactions between volatile and nonvolatile coffee components. 1. Screening of nonvolatile components.

This study is the first of two publications that investigate the phenomena of coffee nonvolatiles interacting with coffee volatile compounds. The purpose was to identify which coffee nonvolatile(s) are responsible for the interactions observed between nonvolatile coffee brew constituents and thiols, sulfides, pyrroles, and diketones. The overall interaction of these compounds with coffee brews prepared with green coffee beans roasted at three different roasting levels (light, medium, and dark), purified nonvolatiles, and medium roasted coffee brew fractions (1% solids after 1 or 24 h) was measured using a headspace solid-phase microextraction technique. The dark roasted coffee brew was slightly more reactive toward the selected compounds than the light roasted coffee brew. Selected pure coffee constituents, such as caffeine, trigonelline, arabinogalactans, chlorogenic acid, and caffeic acid, showed few interactions with the coffee volatiles. Upon fractionation of medium roasted coffee brew by solid-phase extraction, dialysis, size exclusion chromatography, or anion exchange chromatography, characterization of each fraction, evaluation of the interactions with the aromas, and correlation between the chemical composition of the fractions and the magnitude of the interactions, the following general conclusions were drawn. (1) Low molecular weight and positively charged melanoidins present significant interactions. (2) Strong correlations were shown between the melanoidin and protein/peptide content, on one hand, and the extent of interactions, on the other hand (R = 0.83-0.98, depending on the volatile compound). (3) Chlorogenic acids and carbohydrates play a secondary role, because only weak correlations with the interactions were found in complex matrixes.

Carbohydrates↗

Fast in vivo microextraction: a new tool for clinical analysis.

BACKGROUND: We sought to develop a technique with the potential to partly replace current methods of analysis based on blood draws. To achieve this goal, we developed an in vivo microextraction technique that is faster than conventional methods, interferes minimally with the investigated system, minimizes errors associated with sample preparation, and limits exposure to hazardous biological samples. METHODS: Solid-phase microextraction devices based on hydrophilic polypyrrole and polyethylene glycol coatings were used for direct extraction of drugs from the flowing blood of beagle dogs, over a period of 8 h. The drugs extracted on the probes were subsequently quantified by liquid chromatography coupled to tandem mass spectrometry. Two calibration strategies--external and standard on the fiber--were used to correlate the amount extracted with the in vivo concentration. RESULTS: Diazepam and its metabolites were successfully monitored over the course of a pharmacokinetic study, repeated 3 times on 3 beagles. The fast microextraction technique was validated by comparison with conventional plasma analysis, and a correlation factor of 0.99 was obtained. In addition to total concentrations, the method was useful for determining free drug concentrations. CONCLUSIONS: The proposed technique has several advantages and is suitable for fast clinical analyses. This approach could be used not only for drugs, but for any other endogenous or exogenous compounds.

Animals↗

Phase distribution of synthetic pyrethroids in runoff and stream water.

Synthetic pyrethroids (SPs) are a group of hydrophobic compounds with significant aquatic toxicity. Their strong affinity to suspended solids and humic materials suggests that SPs in natural surface water are distributed in solid-adsorbed, dissolved organic matter (DOM)-adsorbed, and freely dissolved phases. The freely dissolved phase is of particular importance because of its mobility and bioavailability. In the present study, we used solid-phase microextraction to detect the freely dissolved phase, and we evaluated the phase distribution of bifenthrin and permethrin in stream and runoff waters. In stream water, most SPs were associated with the suspended solids and, to a lesser extent, with DOM. The freely dissolved phase contributed only 0.4% to 1.0%. In runoff effluents, the freely dissolved concentration was 10% to 27% of the overall concentration. The predominant partitioning into the adsorbed phases implies that the toxicity of SPs in surface water is reduced because of decreased bioavailability. This also suggests that monitoring protocols that do not selectively define the freely dissolved phase can lead to significant overestimation of toxicity or water-quality impacts by SPs.

Adsorption↗

Automated headspace solid-phase dynamic extraction to analyse the volatile fraction of food matrices.

High concentration capacity headspace techniques (headspace solid-phase microextraction (HS-SPME) and headspace sorptive extraction (HSSE)) are a bridge between static and dynamic headspace, since they give high concentration factors as does dynamic headspace (D-HS), and are as easy to apply and as reproducible as static headspace (S-HS). In 2000, Chromtech (Idstein, Germany) introduced an inside-needle technique for vapour and liquid sampling, solid-phase dynamic extraction (SPDE), also known as "the magic needle". In SPDE, analytes are concentrated on a 50 microm film of polydimethylsiloxane (PDMS) and activated carbon (10%) coated onto the inside wall of the stainless steel needle (5 cm) of a 2.5 ml gas tight syringe. When SPDE is used for headspace sampling (HS-SPDE), a fixed volume of the headspace of the sample under investigation is sucked up an appropriate number of times with the gas tight syringe and an analyte amount suitable for a reliable GC or GC-MS analysis accumulates in the polymer coating the needle wall. This article describes the preliminary results of both a study on the optimisation of sampling parameters conditioning HS-SPDE recovery, through the analysis of a standard mixture of highly volatile compounds (beta-pinene, isoamyl acetate and linalool) and of the HS-SPDE-GC-MS analyses of aromatic plants and food matrices. This study shows that HS-SPDE is a successful technique for HS-sampling with high concentration capability, good repeatability and intermediate precision, also when it is compared to HS-SPME.

Food Analysis↗

Identification of proteins by capillary electrophoresis-tandem mass spectrometry. Evaluation of an on-line solid-phase extraction device.

Capillary electrophoresis-tandem mass spectrometry has been used successfully for the analysis of complex peptide mixtures. The method is limited by a relatively high concentration limit of detection and by matrix effects. Here we describe on-line coupling of a solid-phase microextraction device to a capillary electrophoresis-tandem mass spectrometry system. The performance of the integrated instrument was evaluated for the identification of proteins by their amino acid sequence. We report that the concentration limit of detection was improved at least 1000 fold to the low attomole/microliter range and that matrix effects were minimized by extensive sample clean-up during solid-phase extraction. We demonstrate that the implementation of a solid-phase extraction device significantly enhances capillary electrophoresis-tandem mass spectrometry as a method for the identification of low abundance proteins isolated from high-resolution two-dimensional polyacrylamide gels.

Amino Acid Sequence↗

Solvent bar microextraction.

In this work, a new and simple microextraction method termed solvent bar microextraction (SBME) was developed. In this method, the organic extractant solvent (1-octanol) was confined within a short length of a hollow fiber membrane (sealed at both ends) that was placed in a stirred aqueous sample solution. Tumbling of the extraction device within the sample solution facilitated extraction. Pentachlorobenzene (PCB) and hexachlorobenzene (HCB) were used as model compounds to investigate the extraction performance. Analysis was carried out by gas chromatography/electron capture detection. This new method provided very high enrichment (approximately 110-fold for PCB and approximately 70-fold for HCB) in 10 min and good reproducibility (<4%, n = 6). Since the hollow fiber membrane was sealed, it could be used for extraction from "dirty" samples, such soil slurries. This novel microextraction method was compared with single-drop microextraction and static hollow fiber membrane microextraction in which the extractant solvent was also held within a hollow fiber but with the latter fixed to a syringe needle (i.e., there was no tumbling effect). Comparison between SBME and conventional solid-phase microextraction in a soil slurry sample was also investigated.

Journal Article↗

Experimental and modeling studies showing the effect of lipid type and level on flavor release from milk-based liquid emulsions.

The purpose of this work was to study two key parameters of the lipid phase that influence flavor release-lipid level and lipid type-and to relate the results to a mass balance partition coefficient-based mathematical model. Release of 10 volatile compounds from milk-based emulsions at 10, 25, and 50 degrees C was monitored by 1-min headspace sampling with a solid-phase microextraction fiber, followed by GC-MS analysis. As compared to the observations for milk fat, changing to a lipophilic lipid (medium-chain triglycerides, MCT) and adding a monoglyceride-based surfactant did not influence the volatiles release. However, increasing the solid fat content was found to increase the release. At 25 degrees C, and even more so at 10 degrees C, concurrent with an increase in their solid fat content, hydrogenated palm fat emulsions showed increased flavor release over that observed for emulsions made with coconut oil, coconut oil with surfactant, milk fat, and MCT. However, at 50 degrees C, when hydrogenated palm fat emulsions had zero solid fat content, there was no difference in flavor release from that observed for milk fat emulsions. Varying milk fat at nine levels between 0 and 4.5% showed a systematic dependence of the release on the lipid level, dependent on compound lipophilicity. Close correlations were found between the experimental and model predictions with lipid level and percent liquid lipid as variables.

Animals↗