PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “COMPRESSION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64Linked to original sources

Dynamic compression of chondrocyte-seeded fibrin gels: effects on matrix accumulation and mechanical stiffness.

OBJECTIVE: Various strategies have been tested to direct and control matrix synthesis in tissue engineered cartilage, including mechanical stimulation of the construct both before and after implantation. This study examined the effects of oscillatory compression on chondrocytes in a fibrin-based tissue engineered cartilage. DESIGN: Chondrocyte-seeded fibrin gels were cultured under unconfined mechanical compression for 10 or 20 days (free-swelling, 10% static, or 10+/-4% at 0.1 or 1Hz). During the culture period, accumulation of nitrite, sGAG, and proteolytic enzymes in the culture media were monitored. Following culture, the mechanical stiffness and biochemical content of the gels (DNA, sGAG, and hydroxyproline content and GAG Delta-disaccharide composition) were assessed. RESULTS: Compared to free-swelling conditions, static compression had little effect on the mechanical stiffness or biochemical content of the gels. Compared to static compression, oscillatory compression produced softer gels, inhibited sGAG and hydroxyproline accumulation in the gels, and stimulated accumulation of nitrite and sGAG in the culture media. Minimal differences were observed in DNA content and Delta-disaccharide composition across treatment conditions. CONCLUSIONS: In this study, oscillatory compression inhibited formation of cartilage-like tissues by chondrocytes in fibrin gels. These results suggest that the effects of mechanical stimuli on tissue engineered cartilage may vary substantially between different scaffold systems.

Animals↗

Optimal compressive force induces bone formation via increasing bone sialoprotein and prostaglandin E(2) production appropriately.

Although orthodontic tooth movement can promote bone formation, the molecular mechanism that underlies this phenomenon is not fully understood. The purposes of this study were to determine how mechanical stress affects the osteogenic response of human osteoblastic cells (Saos-2), and also examine the optimal compression for osteogenesis in vitro. Saos-2 cells cultured with or without continuously compressive force (0.5 approximately 3.0 g/cm(2)). The expression of bone sialoprotein (BSP), osteopontin, and cyclooxygenase-2 (COX-2) were measured using real-time PCR, Western blot analysis and immunoassay. The calcium content in the mineralized nodules was determined using Calcium C-Test kit. Only one loading with 1.0 g/cm(2) of compressive force significantly increased the expression of BSP mRNA and protein, COX-2 mRNA expression and PGE(2) synthesis. Indomethacin, an inhibitor of PGE(2) synthesis, inhibited the compression-induced above phenomenon. Moreover, the conditioned medium from 1.0 g/cm(2) of compressive force apparently stimulated calcium content in mineralized nodules. This study demonstrates that an optimal compressive force stimulates in vitro mineralization by BSP synthesis through the autocrin action of PGE(2) production.

Bone Remodeling↗

Static compression induces zonal-specific changes in gene expression for extracellular matrix and cytoskeletal proteins in intervertebral disc cells in vitro.

Compressive stimuli associated with weight-bearing and loading of the intervertebral disc are believed to be important regulators of disc cell metabolism. In this study, changes in gene expression levels for extracellular matrix and cytoskeletal proteins were quantified in disc cells in an alginate culture system subjected to static unconfined compression (25% compressive strain) after different time periods (2, 18 and 30 h). Differences in gene expression were observed between anulus fibrosus and nucleus pulposus cells following static compression for the matrix proteins studied here. Anulus fibrosus cells responded to mechanical deformation at the 30-h time point, with increasing gene expression for types I and II collagen, aggrecan, biglycan, decorin and lumican. In contrast, nucleus pulposus cells were not responsive to mechanical loading with changes in gene expression for these matrix proteins at any time. Our results also show that anulus fibrosus cells, but not nucleus pulposus cells, responded to static compression with increased expression of vimentin mRNA as well as increased polymerization of vimentin subunits. The results of the current study illustrate that fibrochondrocytes of the anulus fibrosus may regulate biosynthesis at the transcriptional level following mechanical deformation in an alginate construct. In contrast, the biological response of nucleus pulposus cells to these same stimuli is not detectable. These differences may be attributed to the presence of a notochordal cell population in the immature nucleus pulposus studied here, with a more diffuse and stiff cytoskeleton that may restrict deformations or shape changes upon compressive loading.

Animals↗

Direct digital lateral cephalometry: the effects of JPEG compression on image quality.

OBJECTIVES: This study used an aluminium test object to assess the effect of the Joint Photographics Expert Group (JPEG) compression algorithm, on direct digital cephalometric image quality. METHODS: The aluminium block of 15 steps, with 20 holes in each step was radiographed in a Planmeca Proline 2002 digital cephalometric machine with Dimaxis2 software. Six different JPEG compression ratios were used to capture the cephalometric images. These ratios were 60%, 70%, 80%, 90%, TOP QUALITY JPEG (TQJPEG 98%) and TIFF (uncompressed). The images were taken at 68 kV and 12 mA with a 7 s exposure. Six experienced observers viewed the monitor displayed images, which were presented randomly. This was repeated one month later. The number of holes detected by each observer was plotted against each compression ratio. Intra-observer and inter-observer reproducibility was calculated using the Mann-Whitney U-test. Differences between the compression ratios were assessed using a Kruskal-Wallis one-way analysis of variance. RESULTS: When comparing intra-observer reproducibility, it was found that there were only four of 36 comparisons that showed a statistically significant difference (Observer 1: 60% (P=0.004), TQJPEG (P=0.019); Observer 2: TIFF (P=0.005); Observer 3: 90% (P=0.007)). Statistically, there was no significant difference with inter-observer reproducibility. There was no statistically significant difference between the image quality obtained from each compression ratio. CONCLUSIONS: The results showed that JPEG compression does not have any effect on the perceptibility of landmarks in the aluminium test object used in this study.

Algorithms↗

Post-shock chest compression delays with automated external defibrillator use.

PRIMARY OBJECTIVE: In a swine model of out-of-hospital ventricular fibrillation (VF) cardiac arrest, we established that automated external defibrillator (AED) defibrillation could worsen outcome from prolonged VF compared with manual defibrillation. Worse outcomes were due to substantial interruptions and delays in chest compressions for AED rhythm analyses and shock advice. In particular, the mean interval from first AED shock to first post-shock compressions was 46+/-6s. We hypothesized that the delay from shock to provision of chest compressions is similar in the out-of-hospital setting. MATERIALS AND METHODS: We conducted a retrospective observational review of AED-treated adult VF cardiac arrest victims over a 26-month period to determine the interval from the first AED defibrillation attempt to the initial provision of post-shock chest compressions for out-of-hospital VF cardiac arrests. A two-tiered, single emergency medical service (EMS) system with AED-equipped first responders serves our area of 400 km2 with a population of 487,000 people. The defibrillators record a detailed sequence of events during the resuscitation effort that includes the electrocardiogram with real clock times and a recording of surrounding audible actions. RESULTS: A median of 38 s (IQR 15, 61 s) elapsed between the first shock and the initiation of chest compressions. Approximately half of the delay was due to mechanical/electronic factors and the remainder due to human factors. Of 64 adults in VF, 45 (70%) died before hospital admission, 19 (30%) survived to admission and 10 (16%) survived to hospital discharge. CONCLUSION: Substantial delays in the provision of post-shock chest compressions are typical in this EMS system with AED-equipped first responders.

Adult↗

Contrast dependency of sacadic compression and suppression.

In the occurrence of a saccadic eye movement vision becomes suppressed. Supra-threshold visual stimuli that are briefly presented at that time become perceptually compressed towards the saccade target (saccadic compression) and shifted in saccade direction (saccadic shift). We show that the strength of saccadic compression, like the strength of saccadic suppression, varies with stimulus contrast. Low contrast stimuli lead to stronger compression than high contrast stimuli. The similarity of contrast dependence and time course suggests that saccadic compression is related to saccadic suppression. Because the saccadic shift did not depend on contrast we suggest that shift and compression are different effects.

Adult↗

Effects of intermittent pneumatic leg compression for prevention of postoperative deep venous thrombosis with special reference to fibrinolytic activity.

The mechanism of intermittent pneumatic leg compression for prevention of postoperative deep venous thrombosis was investigated. The incidence of postoperative deep venous thrombosis was studied using iodine-125 fibrinogen in 64 patients with malignant disease who had intermittent pneumatic leg compression for 48 hours postoperatively. Changes in euglobulin lysis time and B beta 15-42 peptide were investigated before and after operation in 16 patients with benign disease, in 27 patients with malignant disease who did not have postoperative intermittent pneumatic leg compression, and in another 29 patients with malignant disease who had postoperative intermittent pneumatic leg compression. The overall incidence of deep venous thrombosis was 6.25 percent. A prolongation of euglobulin lysis time was found postoperatively in all three groups, which was significant in malignant disease groups, although less significant in the group with intermittent pneumatic leg compression when compared with the benign disease group. Preoperatively, a significant increase in B beta 15-42 peptide was found in patients with malignant disease when compared with patients with benign disease. Postoperatively, the B beta 15-42 level increased in the same pattern in all groups and no significant differences in the levels were found among them. A significant shortening of euglobulin lysis time by intermittent pneumatic leg compression, in addition to its hemodynamic effects, is considered an important factor in the prevention of postoperative deep venous thrombosis.

Female↗

Osmotic compression and stiffness changes in relaxed skinned cardiac myocytes in PVP-40 and dextran T-500.

Sarcomere lengths, cell widths, indices of stiffness, and striation pattern uniformity were determined from radially compressed isolated adult cardiac myocytes from the rat. Single cells were bathed in a series of relaxing solutions containing 0-15% concentrations of nonpenetrating long chain polymers PVP-40 and dextran T-500. There were no significant changes observed in average sarcomere lengths or in striation pattern uniformity at any concentration. But cell widths decreased and stiffness increased in both polymers in a concentration-osmotic pressure-dependent relationship. Changes in cell width and stiffness were repeatable in either polymer, but only after an initial compression with a 10 or 15% concentration solution. The observed reduction in cell width after initial compression correlates well with known myofilament lattice spacing compression in rat cardiac muscle and is qualitatively similar to compressions seen in skeletal muscle preparations. But the cardiac myofilament lattice may not be as compressible as the skeletal lattice. Like skeletal muscle, stiffness exhibits a two-phase relationship where most of the increase occurs at solution osmotic pressures greater than 20 Torr. Finally, the inherently greater passive stiffness-length relationship of cardiac muscle is maintained at higher osmotic pressures such that the passive elastic modulus is strongly length dependent.

Actin Cytoskeleton↗

Compression of lipid membranes as observed at varying membrane positions.

We have measured the microscopic isothermal compressibility of dioleoyl- and dimyristyl-phosphatidylcholine multilayers and bilayers as a function of membrane depth by the pressure dependence of the polarization of a series of anthroyloxy fatty acids. In both systems, within experimental error, the compressibility did not change with membrane depth. The magnitudes of the compressibilities matched those of organic solids and those reported for dipalmitoylphosphatidylcholine multilayers from neutron diffraction measurements (Braganza, L. F., and D. L. Worcester. 1986. Biochemistry, 25:7484-7488). The bilayer compressibility decreased with temperature and this decrease was similar with membrane depth consistent with the isotropic thermal expansion of membranes previously observed (Scarlata, S. 1989. Biophys. J. 55:1215-1223). The vertical compressibility in the z direction is much lower than the horizontal (xy planes) for probes that lie parallel to the hydrocarbon chains which is consistent with an increase in bilayer thickness. The compressibility for probes that lie perpendicular to the hydrocarbon chains is more isotropic due to their limited spatial access to the z plane.

Biophysical Phenomena↗

Compressive behavior of articular cartilage is not completely explained by proteoglycan osmotic pressure.

It has been hypothesized that applied mechanical or osmotic loads which decrease cartilage volume by 5% or more are sufficient to relieve all collagen tensile forces, and that further changes in the applied load are completely supported by changes in proteoglycan osmotic pressure. In this view, cartilage should behave mechanically like a concentrated solution of proteoglycans. We tested this hypothesis by measuring the equilibrium axial and radial stresses in bovine articular cartilage during uniaxial confined compression. If the hypothesis is correct, the observed changes in the radial and axial stresses in confined compression should be equal for compression greater than 5%. However, the observed change in axial stress was always substantially greater than the change in radial stress over the range of strains (5-26%) and saline concentrations (0.05-0.15 M) tested. This indicates that the mechanical behavior of cartilage in confined compression cannot solely be explained by changes in proteoglycan osmotic pressure even for strains as large as 26%. A linear isotropic model was found to describe the observed equilibrium behavior adequately. In addition, the inferred shear modulus was found to be independent of saline concentration and similar to measurements by others of the flow-independent shear modulus. Our results have implications regarding the relative contribution of the proteoglycans and collagen to the mechanical properties of the tissue in compression, and suggest that tensile forces in the collagen network may play an important role in determining tissue behavior in confined compression even for relatively large volume changes.

Animals↗

Degeneration affects the anisotropic and nonlinear behaviors of human anulus fibrosus in compression.

Axial and radial specimens of non-degenerate and degenerate human anulus fibrosus (AF) were tested in confined compression to test the hypothesis that degeneration significantly affects the compressive properties of AF. Due to the highly oriented structure of AF, a secondary objective was to investigate anisotropic behaviors of AF in compression. Uniaxial swelling and stress relaxation experiments were performed on site-matched samples of anulus from the anterior outer region of L2-3 intervertebral discs. The experimental stress-relaxation behavior was modeled using the finite deformation biphasic theory and a finite-difference approximation scheme. Significant effects of degeneration but not orientation were detected for the reference stress offset, sigma(offset), and parameters describing the compressive stiffness (i.e. reference aggregate modulus, H(A0), and nonlinear stiffening coefficient, beta). Average values were 0.13+/-0.06 and 0.05+/-0.05 MPa for sigma(offset), 0.56+/-0.21 and 1.10+/-0.53 MPa for H(A0) and 2.13+/-1.48 and 0.44+/-0.61 for beta for all normal and degenerate specimens, respectively. No significant effect of degeneration or orientation were detected for either of the parameters describing the strain-dependent permeability (i.e. reference permeability, k0 and strain-dependent permeability coefficient, M) with average values for all specimens of 0.20+/-0.10 x 10(-15) m4/N-s and 1.18+/-1.30 for k0 and M, respectively. The loss of sigma(offset) was compensated with an elastic stiffening and change in the shape of the equilibrium stress-strain curve with H(A0) for degenerate tissues almost twice that of normal tissues and beta less than one sixth. The increase in reference elastic modulus with degeneration is likely related to an increase in tissue density resulting from the loss of water content. The significant effects of degeneration reported in this study suggested a shift in load carriage from fluid pressurization and swelling pressure to deformation of the solid matrix of the AF. The results also suggest that the highly organized and layered network of the anulus fibrosus, which gives rise to significant anisotropic effects in tension, does not play a major role in contributing to the magnitude of compressive stiffness or the mechanisms of fluid flow of the anulus in the confined compression configuration.

Adolescent↗

Abdominal muscles contribute in a minor way to peak spinal compression in lifting.

In lifting, the abdominal muscles are thought to be activated to stabilize the spine. As a detrimental effect, they contribute to spinal compression. The existing literature is not conclusive about the biological relevance of this effect. From biological, mechanical and anatomical considerations it was hypothesised that the relative abdominal contribution to compression would be minor in the beginning of the lift, that the relative and absolute abdominal contribution to compression would rise throughout the lift, and that the obliques would contribute to a larger extent than the rectus abdominis. To investigate these hypotheses, 10 subjects lifted 0.5, 10.5 and 22.5 kg. EMG levels obtained from the rectus abdominis and the obliques were converted into force using normalized EMG, muscle potential and area values, and modulating factors for muscle length and contraction velocity. An anatomical model was applied to compute the abdominal effects on spinal compression in three consecutive phases within a lift. If expressed relative to the total spinal compression, the abdominal contribution for the three weight conditions was 7.1% (SD, 1.7), 10.4% (4.7) and 12.5% (4.4) in the begin and 21.0% (5.8), 19.0% (5.3) and 22.2% (6.6) in the end phase. Thus, the relative abdominal contribution to compression was minor in the beginning and increased towards the end. The absolute abdominal contribution was constant throughout the lift. The contributions could be retraced to the obliques rather than the rectus, while during the lift a shift in activation from the obliquus externus to internus was observed.

Abdominal Muscles↗

Diagnostic advantages of manual compression fluoroscopy in the radiologic work-up of vomiting neonates.

This paper describes a simple and effective fluoroscopic technique that remarkably improves diagnostic accuracy when evaluating vomiting newborns. The technique also minimizes the time of the examination and the radiation dose to the patient and radiology personnel. Several examples are presented illustrating the superiority of gloved hand or nonopaque compression technique to conventional contrast radiography, emphasizing babies with pyloric stenosis and midgut malrotation. The technical limitations and diagnostic pitfalls of conventional contrast modalities are compared to the highly diagnostic images obtained with manual compression fluoroscopy. All of the classic radiographic signs of pyloric stenosis can be mimicked by antral spasm or pylorospasm. Gloved hand compression overcomes antral spasm and clearly shows the true length and diameter of the pyloric canal in these two conditions. Malposition of the duodenojejunal junction is the only consistently diagnostic sign of midgut malrotation. Nonfixation of the duodenojejunal junction can be competently assessed by compression fluoroscopy, confirming malrotation and midgut volvulus simultaneously and bringing the patient to operation much sooner than with less precise conventional techniques. Gloved hand compression technique also evaluates stenotic areas in the upper gastrointestinal tract, distinguishing spasm from organic marrowing and clearly identifying those which need surgical intervention. Facilitating intubation of the duodenum is a final contribution of compression fluoroscopy.

False Negative Reactions↗

Comparison of accuracy between compression- and injection-molded complete dentures.

STATEMENT OF PROBLEM: A clinically significant incisal pin opening may occur after processing complete dentures if a compression molding technique is used. To recover the proper vertical dimension of occlusion, a time-consuming occlusal adjustment is necessary that often destroys the anatomy of the artificial teeth. A new injection molding process claims to produce dentures that require few, if any, occlusal adjustments in the laboratory after processing. PURPOSE: This laboratory study compared incisal pin opening, dimensional accuracy, and laboratory working time for dentures fabricated by this new injection system with dentures constructed by the conventional compression molding technique. MATERIAL AND METHODS: Two groups of 6 maxillary and 6 mandibular dentures were evaluated as follows: group 1 (control), Lucitone 199, compression molded with a long cure cycle; and group 2, Lucitone 199, injection molded with a long cure. Incisal pin opening was measured with a micrometer immediately after deflasking. A computerized coordinate measuring machine was used to measure dimensional accuracy of 3-dimensional variations in selected positions of artificial teeth in 4 stages of denture fabrication. Analysis of variance (ANOVA) and t tests were performed to compare the groups. RESULTS: A significant difference was found in pin opening between groups (t test). Horizontal dimensional changes evaluated with repeated measures ANOVA revealed no significant differences between groups. However, analysis of vertical dimensional changes disclosed significant differences between the groups. There was no appreciable difference in laboratory working time for flasking and molding denture bases between the injection and compression molding techniques when polymethyl methacrylate resin was used. CONCLUSION: The injection molding method produced a significantly smaller incisal pin opening over the standard compression molding technique. The injection molding technique, using polymethyl methacrylate, was a more accurate method for processing dentures. There were no appreciable differences in laboratory working time between the injection and compression molding techniques.

Analysis of Variance↗

Effect of the compression ratio on properties of lung surfactant (bovine lipid extract surfactant) films.

Using axisymmetric drop shape analysis (ADSA) and a captive bubble technique, the properties of lung surfactant (BLES) films under different compression ratios (i.e. the ratio of maximum to minimum surface area of the bubble) were investigated. In particular, the effect of the compression ratio of the films on the shape of the volume area surface tension-time (VAST) graphs and on the shape of the surface tension relative area (gamma-A ) graphs was examined at the air-liquid interface. Under relatively low compression ratios of the films, the VAST and gamma-A graphs indicate that the cycling is reversible (i.e. the gamma-A graphs are identical for expansion and compression). When the compression ratio of the films increases, failure tends to occur when the surface film can not support the increasing surface pressure, causing a hysteresis loop in the gamma-A graph. It was also found that low surface tension (i.e. below 5 mJ/m2) at the interface could be attained with a 30% compression ratio and collapse of the films always occurs near or below 1 mJ/m2.

Adsorption↗

The role of presaccadic compression of visual space in spatial remapping across saccadic eye movements.

When multiple bars are briefly flashed near the saccadic goal on a visual reference just before a saccade, the total width of the multiple bars appears to be compressed toward the saccadic goal. We show that presaccadic compression of visual space is related to the attribution of the displacement of a visual stimulus to the displacement of another stimulus appearing after the saccade. Subjects observed a bar and a ruler. The bar was displaced during a saccade and the ruler disappeared briefly at the same time, and then the ruler reappeared at the same location after the saccade. The subjects had the impression that the bar appeared to remain stationary and the ruler appeared to be displaced after the saccade. This impression occurs strongly when the amount of the compression of visual space reaches the maximum at the saccade onset. Also, it occurs only at the saccadic goal in the same way as presaccadic compression of visual space. Saccadic suppression of displacement was equivalent at the saccadic goal and in the location opposite to the saccadic goal, indicating that the attribution of the bar displacement to the displacement of the ruler appearing after the saccade is not a consequence of saccadic suppression of displacement. Furthermore, performing a direction discrimination task showed that the bar appears stationary at the saccadic goal during compression of visual space even when the bar was actually displaced. We interpret these results as showing that presaccadic compression of visual space establishes the location of the saccadic goal (the bar) as a reference and then the location of the ruler is remapped relative to the reference location after the saccade, resulting in the illusory displacement of the ruler.

Adult↗

Mechanical compression of a fibrous membrane surrounding bone causes bone resorption.

Early micromovement and migration of a prosthesis of a hip or knee predicts late clinical loosening of the prosthesis. Such migration is likely to be associated with mechanical compression of the fibrous membrane interpositioned between bone and prosthesis during movement. Compression of the fibrous membrane by loading may lead to locally high fluid pressures reaching the underlying bone tissue. It has been established that high fluid pressures can lead to bone resorption. This resorption may eventually lead to clinical loosening of the prosthesis. We developed an experimental model to study the effects of compression of a soft tissue layer located between a titanium implant and cortical bone. In twelve rabbits, this device was implanted in the proximal tibia and allowed to osseointegrate. Next, a layer of soft tissue was allowed to form between titanium and bone. Subsequently, in six rabbits a cyclic load of 60 times in 2 min per day during 2 weeks was applied, leading to compression of the interpositioned soft tissue layer only. In the other six rabbits no load was applied. In all six loaded specimens, osteocyte death and bone resorption was observed underneath the area where compression of the fibrous membrane was exerted to a depth exceeding the amplitude of the loading device. Furthermore, formation of fibrocartilage was observed in the loaded areas. Formation of fibrocartilage, osteocyte death or bone resorption did not occur in the controls. Our results indicate that compression of a fibrous membrane surrounding bone can lead to resorption of the underlying bone primarily because of osteocyte death and subsequent resorption of dead bone tissue. This may explain the observation that early migration of a hip or knee prosthesis is predictive of clinical loosening of the prosthesis.

Animals↗

Thermal compression and characterization of three-dimensional nonwoven PET matrices as tissue engineering scaffolds.

Nonwoven fibrous matrices have been widely used as scaffolds in tissue engineering, and modification of microstructure of these matrices is needed to organize cells in three-dimensional space with spatially balanced proliferation and differentiation required for functional tissue development. The method of thermal compression of nonwoven polyethylene terephthalate (PET) fabrics was developed and key parameters of temperature, pressure, and compression duration were evaluated in this study. The permanent deformation was obtained at elevated temperature under pressure and the viscoelastic compressional behaviors were observed, characterized by a distinct apparent modulus change in glass transition temperature region. A liquid extrusion method was further employed to analyze both pore size and its distribution for matrices with porosity ranging from 84 to 93%. It is also found that a more uniformly distributed pore size was resulted from thermal compression and the isotropic nature of nonwoven fabrics was preserved because of the proportional reduction of the pore by compression. The thermally compressed fabric matrices with two different pore sizes (15 and 20 microm in pore radius) were used to culture human trophoblast ED27 and NIH 3T3 cells. It was found that cells cultured in the different pore-size PET matrices had different cell spatial organization and proliferation rates. The smaller pores in the matrix allowed cells to spread better and proliferate faster, while cells in the larger pores tended to form large aggregates and had lower proliferation rate. The thermal compression technique also can be applied to other synthetic fibrous matrices including biodegradable polymers used in tissue engineering to modify the microstructure according to their viscoelastic properties.

3T3 Cells↗