An information-processing explanation of some perceptual phenomena.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
1. A study has been made of the temperature changes associated with the passage of a single impulse in rabbit desheated vagus nerves.2. The initial changes consist of an evolution of positive heat followed by a reabsorption of most of it; i.e. there is a phase of positive and a phase of negative heat production.3. The size of the positive heat, its time of onset, and the time of onset of the negative heat have been measured by an analogue method of analysis. In addition, these parameters, together with the size of the negative heat and the duration of both phases of initial heat, have been studied with the aid of a computer, and also by conventional heat block analysis.4. At about 5 degrees C the measured positive heat is 7.2 mucal/g. impulse. It starts as soon as the compound action potential reaches the thermopile and lasts for about 107 msec.5. This positive heat decreases with increasing temperature, the ratio of heat at 4 degrees C to that at 14 degrees C being 1.86.6. The measured negative heat at about 5 degrees C is 4.9 mucal/g. impulse. It starts 102 msec after the onset of positive heat, and lasts for about 240 msec.7. When the sodium of Locke solution is replaced by lithium the positive heat is reduced by 19%, but the negative heat is increased by 22%.8. In potassium-free solutions the positive heat is hardly affected (increase of 5%), but the negative heat is more than doubled. As a result the nerve may become briefly colder than its initial temperature by about 2 mu degrees C.9. The effect of sodium-deficient solutions on the positive heat is somewhat variable, but the negative heat is consistently diminished.10. Replacement of the chloride of Locke solution by sulphate or nitrate has little effect on the positive heat. The negative heat is reduced in size by 26% and in duration by 22%.11. Replacement of most of the sodium of Locke solution by barium reduces or abolishes the negative heat, and increases the measured size of the positive heat nearly threefold.12. Veratrine (10(-5) g/ml.) produces a nearly tenfold increase in the net positive heat.13. Ouabain (1 mM) and antimycin A (1 mug/ml.) applied for 30-60 min have little effect on the initial heat production.14. Over the temperature range 5-15 degrees C, and for the ionic solution changes described above, there is close agreement in timing between the positive heat and the rising phase of the action potential, and between the negative heat and the falling phase.15. Because of the inevitable temporal dispersion of the action potential over the face of the thermopile, the observed temperature changes are smaller than those which occur at a single point in the nerve close to a stimulating electrode. The corrected value of the positive heat at 5 degrees C is 24.5 mucal/g. impulse, while that of the negative heat is 22.2 mucal/g. impulse.16. The heats of mixing of the ions in solution that interchange during the action potential are much too small to account for the observed initial heats, but an exchange of ions associated with fixed charges might make a significant contribution to the heats.17. The condenser theory, according to which the positive heat represents the dissipation of electrical energy stored in the membrane capacity, while the negative heat results from the recharging of the capacity, appears unable to account for more than half of the observed temperature changes.18. It seems probable that the greater part of the initial heat results from changes in the entropy of the nerve membrane when it is depolarized and repolarized.
1. Discrete depolarizations of the photoreceptor cell membrane called discrete waves occur spontaneously and in response to illumination in the eye of the horseshoe crab, Limulus. Each light induced discrete wave is caused by the absorption of a single photon.2. The frequencies of spontaneous and light induced discrete waves were studied at different temperatures from 0 to 25 degrees C using a new method of counting them to avoid errors due to their temporal overlap.3. The frequency of spontaneous discrete waves followed the Arrhenius relationship with activation energy equal to 48.6 kcal.4. The frequency of the discrete waves caused by a fixed level of steady illumination was not significantly changed when the temperature of the cell was changed.5. The relationship of the frequency of spontaneous discrete waves to temperature was compared to a prediction based on the relationship of the quantum relative spectral sensitivity of the Limulus eye to the temperature of the eye. The prediction was in good agreement with observation and suggests that spontaneous discrete waves result from thermally induced cis to trans isomerizations of visual pigment molecules.
Benzene and several close structural analogs are inhaled drugs of abuse with general anesthetic activity. By virtue of their pi electron clouds, they may engage in attractive electrostatic interactions with cationic atomic charges on protein targets. In this study, we tested the hypothesis that inhaled drugs of abuse inhibit human N-methyl-D-aspartate (NMDA) receptors with potencies that correlate with their abilities to engage in cation-pi interactions. Electrophysiological techniques were used to define the NR1/NR2B NMDA receptor inhibitory concentrations of volatile benzene analogs, and computer modeling was used to quantify their abilities to engage in cation-pi interactions and their molecular volumes. In addition, each compound's octanol/gas partition coefficient (a measure of hydrophobicity) was quantified. All 18 compounds inhibited human NR1/NR2B NMDA receptors reversibly and in a concentration-dependent manner. NMDA receptor inhibitory potency correlated strongly with the ability to engage in cation-pi interactions, weakly with hydrophobicity, and was independent of molecular volume. This is consistent with the hypothesis that cation-pi interactions enhance the binding of inhaled drugs of abuse to the NMDA receptor and suggests that the receptor binding site(s) for these drugs possesses significant cationic character.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A method of obtaining pure sensory nerve conduction velocities in the lower extremities is described. This involves the use of electronic summation (signal averaging). Potentials were obtained and velocities calculated from all normal subjects examined. In patients with peripheral neuropathies it was often possible to obtain nerve velocities with signal amplitudes as low as 0·1 μV and these were often slower than those obtained from the normal subjects. The advantages and disadvantages of this method are discussed. It is of significant clinical value in that pure sensory nerve conduction velocities can be measured in the legs when this may be the only valuable parameter in the absence of motor involvement. In addition, investigation of neuropathies at an earlier stage of development and recovery may be facilitated. It is hoped that in the future this technique of obtaining low amplitude responses with an analogue averager can be incorporated with the more routine aspects of nerve conduction testing when clinically indicated.
In a single fibre EMG investigation on healthy subjects the relationship between the neuromuscular jitter and the safety factor of the motor end-plate relative to curare was studied. A positive correlation was found between the jitter increase after a standard dose of D-tubocurarine and the initial jitter. The conclusion was drawn that the neuromuscular jitter can be used as an indicator of the safety factor. There are a number of nerve-muscle disorders in which the jitter is increased, probably indicating a reduced safety factor which may be of clinical importance when these patients are subjected to diseases or drugs which would otherwise not produce neuromuscular symptomatology.
Explore the source record for details and available documents.
Accurate measurement of pressure differences across a diseased heart valve involves either laborious planimetry or elaborate digital computing facilities. An analogue device is described, simple and inexpensive to construct, which derives from the recorder input of two pressure signals the time (seconds/minute) of valve opening and the mean pressure difference during this time. Measurements may be repeated over long periods. The importance of using pressure differences as compared with peak or end diastolic gradients is noted; serious errors in assessment of valvular disease may otherwise occur.
Explore the source record for details and available documents.